BBN-simple: How to bake a universe-sized cake

Big Bang Nucleosynthesis (BBN), the process of creation of lightest elements in the early universe, is a highly robust, precise, and ultimately successful theory that forms one of the three pillars of the standard hot-Big-Bang cosmological model. Existing theoretical treatments of BBN and the associated computer codes are accurate and flexible, but are typically highly technical and opaque, and not suitable for pedagogical understanding of the BBN. Here we present BBN-simple - a from-scratch numerical calculation of the lightest element abundances pitched at an advanced undergraduate or beginning graduate level. We review the physics of the early universe relevant for BBN, provide information about the reaction rates, and discuss computational-mathematics background that is essential in setting up a BBN calculation. Here, we calculate the abundances of the principal nuclear species in a standard cosmological model, and find a reasonably good agreement with public precision-level BBN codes.

Big bang nucleosynthesis↗

Spacecraft thermal blanket cleaning: Vacuum bake of gaseous flow purging

The mass losses and the outgassing rates per unit area of three thermal blankets consisting of various combinations of Mylar and Kapton, with interposed Dacron nets, were measured with a microbalance using two methods. The blankets at 25 deg C were either outgassed in vacuum for 20 hours, or were purged with a dry nitrogen flow of 3 cu. ft. per hour at 25 deg C for 20 hours. The two methods were compared for their effectiveness in cleaning the blankets for their use in space applications. The measurements were carried out using blanket strips and rolled-up blanket samples fitting the microbalance cylindrical plenum. Also, temperature scanning tests were carried out to indicate the optimum temperature for purging and vacuum cleaning. The data indicate that the purging for 20 hours with the above N2 flow can accomplish the same level of cleaning provided by the vacuum with the blankets at 25 deg C for 20 hours, In both cases, the rate of outgassing after 20 hours is reduced by 3 orders of magnitude, and the weight losses are in the range of 10E-4 gr/sq cm. Equivalent mass loss time constants, regained mass in air as a function of time, and other parameters were obtained for those blankets.

Scialdone, John J.↗

Spacecraft thermal blanket cleaning - Vacuum baking or gaseous flow purging

The mass losses and the outgassing rates per unit area of three thermal blankets consisting of various combinations of Mylar and Kapton, with interposed Dacron nets, were measured with a microbalance using two methods. The blankets at 25 deg C were either outgassed in vacuum for 20 hours, or were purged with a dry nitrogen flow of 3 cu. ft. per hour at 25 deg C for 20 hours. The two methods were compared for their effectiveness in cleaning the blankets for their use in space applications. The measurements were carried out using blanket strips and rolled-up blanket samples fitting the microbalance cylindrical plenum. Also, temperature scanning tests were carried out to indicate the optimum temperature for purging and vacuum cleaning. The data indicate that the purging for 20 hours with the above N2 flow can accomplish the same level of cleaning provided by the vacuum with the blankets at 25 deg C for 20 hours. In both cases, the rate of outgassing after 20 hours is reduced by 3 orders of magnitude, and the weight losses are in the range of 10E-4 gr/sq cm. Equivalent mass loss time constants, regained mass in air as a function of time, and other parameters were obtained for those blankets.

Scialdone, John J.↗

IOTA Pre-Bake Test Development

The IOTA (Integrable Optics Test Accelerator) Bakeout project is intended to improve the quality of the vacuum within the IOTA ring. Impurities consisting of hydrogen and oxygen that build within the beampipe are reduced through applying heat to the beampipe’s exterior. Two versions of the Bakeout project exist, one as a smaller scale test setup, and one five times larger located within the IOTA ring. During my internship, I worked together with a team to bring this project from an effectively dormant state to ready for testing, working together to create full documentation of the PLC (Programmable Logic Controller) programs, making multiple new hardware configurations of this test possible, as well as an additional safety system.

Seagrave, Kayla [DuPage Coll.; Fermilab]↗

Enhancing the performance of solvent-borne poly(ethyl methacrylate) coatings for high-power laser applications via low-temperature drying

Organic polymers are a versatile class of materials employed in a broad range of optical coating applications. However, their use as coatings in high-power laser applications, particularly in the UV spectral region, has been limited in scope due to their relatively low laser-induced damage thresholds (LIDTs), which decrease further with exposure to multiple pulses. This study explores the effect of post-deposition drying temperature and residual solvent on the LIDT of solvent-borne polymer coatings. In this work, poly(ethyl methacrylate) (PEMA) coatings were deposited by first spin coating solutions of PEMA (dissolved in 2,2,2-trichloroethanol (TCE)) onto fused silica substrates, then baking at temperatures of either 130°C (soft-bake) or 180°C (hard-bake). Analysis of the two coatings revealed that the soft-bake coating retained a significant amount of TCE within the polymer matrix, which functioned to plasticize the coating and reduce internal stress. The laser-induced damage resistance of the two coatings was evaluated using 351-nm, 1-ns laser pulses. The testing protocols included single-pulse (1-on-1), 1-pulse ramp (R-on-1), and a 1000-pulse ramp (1000R-on-1) test. The results showed that the plasticized, soft-bake coating exhibits a significantly increased LIDT, especially for multipulse irradiation conditions.

36 MATERIALS SCIENCE↗

The Kinetics of the Coherent Stage of Hydroxide Corrosion on Li 2 O-Covered LiH

The capability to model LiOH growth on vacuum-baked LiH is a necessary precursor to making kinetic predictions of undesirable hydrogen outgassing from corroded LiH materials when placed in sealed-system applications. Here, in this work, LiH samples with initial LiOH surface corrosion layers less than 1.1 μm were outgassed by vacuum baking at high temperature to convert LiOH to Li 2 O. Diffuse-reflectance infrared Fourier transform (DRIFT) spectroscopy was used to measure the subsequent LiOH regrowth during exposure to 25–375 ppm of H 2 O vapor at room temperature. Logarithmic kinetics best model the growth of this coherent hydroxide corrosion layer (up to 1.5 μm) on previously vacuum-baked LiH samples. The logarithmic kinetics are attributed to the dissociation of H 2 O on the corrosion layer and the establishment of a H + /OH – electric field across the thickening LiOH corrosion layer. A time-dependent model of LiOH corrosion growth as a function of both initial LiOH thickness before vacuum baking and moisture partial pressures during re-exposure was developed to help researchers better assess the unwanted hydrogen outgassing potential from LiH/LiD materials.

Matt, Sarah M. [Lawrence Livermore National Labora↗

Outgassing measurements of bare and magnetite-coated low-carbon steel vacuum chambers

The outgassing properties of bare and magnetite-coated AISI 1020 low-carbon steel vacuum chambers were evaluated to establish material selection criteria for extreme high vacuum applications, namely, to explore the possibility of using these materials to build next-generation spin-polarized photoelectron guns. Water outgassing measurements using the throughput method revealed that the magnetite-coated chamber exhibited five times lower outgassing at room temperature prior to baking, but this advantage disappears after 80 °C baking. Hydrogen outgassing measurements demonstrated significant differences after intensive heat treatment: the bare low-carbon steel vacuum chamber achieved a specific outgassing rate of 9.6 × 10 −16 Torr L s −1 cm −2 after 400 °C/50 h bake plus additional heat treatment at lower temperatures, 25 times lower than the magnetite-coated low-carbon steel chamber. Residual gas analysis showed >99% hydrogen composition after heat treatment for both materials, with carbon species below detection limits for bare low-carbon steel versus 0.8% for magnetite-coated surfaces. These measurements indicate that properly conditioned bare low-carbon steel can achieve the <10 −12 Torr pressures required for next-generation spin-polarized photogun applications. In conclusion, the paper includes various analysis techniques intended to explain observed behaviors: isotherm analysis of pump-down plots, Arrhenius analysis of hydrogen outgassing rate data, and residual gas composition tracking.

Adsorption isotherm↗

Hybrid chemical characterization of latent images in EUV resist with 12 nm half-pitch features

With the advancement of high numerical aperture extreme ultraviolet (EUV) lithography, the new platform will enable chipmakers to achieve critical dimensions of 8 nm. However, resist materials face significant challenges in delivering increased sensitivity while managing rising stochastic variations. We aim to develop comprehensive techniques to characterize the chemical profile of latent images, stored in EUV resists after exposure and postexposure baking, which is essential for understanding the origin of stochastic effects. Infrared photo-induced force microscopy (IR PiFM) is a bimodal atomic force microscopy technique combined with an infrared light source, allowing for simultaneous sub-5 nm topographic and chemical characterization within a localized environment. Critical-dimension resonant soft X-ray scatterometry (CD-RSoXS) provides statistical data that reveal structural and chemical information for comparative analysis. For the first time, IR PiFM has been used to chemically map the latent images of EUV resists (after exposure and postexposure baking) at a record high resolution of 12 nm half-pitch, enabling nondestructive analysis of patterns prior to development. Furthermore, CD-RSoXS offers direct experimental observation and comparison of exposed, postexposure baked, and developed patterns, which align with the IR PiFM results. We demonstrate that the IR PiFM technique offers valuable insights into both high spatial resolution and local chemical information simultaneously. In addition, CD-RSoXS provides statistical results that support our main findings. This hybrid metrology approach leverages a multifaceted dataset by combining the most reliable information from each source, which is essential for a comprehensive understanding of the stochastic effects in EUV lithography processes.

O’Reilly, Padraic↗

Decoupling of Nitrogen and Oxygen Impurities in Nitrogen Doped SRF Cavities

The performance of superconducting radiofrequency (SRF) cavities is critical to enabling the next generation of efficient high-energy particle accelerators. Recent developments have focused on altering the surface impurity profile through \textit{in-situ} baking, furnace baking, and doping to introduce and diffuse beneficial impurities such as nitrogen, oxygen, and carbon. However, the precise role and properties of each impurity are not well understood. In this work, we attempt to disentangle the role of nitrogen and oxygen impurities through time-of-flight secondary ion mass spectrometry of niobium samples baked at temperatures varying from 75-800 $^\circ$C with and without nitrogen injection. From these results, we developed treatments recipe that decouple the effects of oxygen and nitrogen in doping treatments. Understanding how these impurities and their underlying mechanisms drive further optimization in the tailoring of impurity profiles for high-performance SRF cavities.

43 PARTICLE ACCELERATORS↗

Oxide dissolution and oxygen diffusion scenarios in niobium and implications on the Bean–Livingston barrier in superconducting cavities

We generalize a native Nb2O5 dissolution model [G. Ciovati, Appl. Phys. Lett. 89, 022507 (2006)] to sequential overlayer dissolutions, multilayer dissolution, and realistic temperature profiles, which may be applicable to other materials. The model is applied to secondary ion mass spectrometry depth profile measurements for varying temperature profiles and two-step oxide dissolution in Nb and found to agree well. In the context of the Meissner screening response due to impurity profiles on the length scale of the London penetration depth, the shallow diffusion of O impurities results in a substantial decrease in the peak supercurrent density near the surface. In this framework, oxide dissolution and oxygen diffusion can account for a rise in peak supportable magnetic field in SRF cavities with baking time and a suppression after the optimal baking time is reached, in good agreement with peak-field baking temperatures and times as well as recent quench field measurements.

Lechner, Eric↗

Ultra-High Vacuum Outgassing Characterization of Thermally Processed Low-Carbon Steel for Advanced Particle Accelerator and Gravitational Wave Detector Applications

This dissertation investigated AISI 1020 low-carbon steel as an alternative vacuum chamber material to conventional stainless steel for ultra-high vacuum (UHV) and extreme-high vacuum (XHV) applications. After a 400 °C/48 h bake, AISI 1020 tube chambers achieved a hydrogen outgassing rate of 2.4 × 10¿¹6 Torr·L·s¿¹·cm¿², approximately 2,300 times lower than the prebaked 316L stainless-steel comparator, among the lowest hydrogen outgassing rates ever reported for an uncoated metallic vacuum chamber. Bare and magnetite-coated AISI 1020 chambers were then compared using throughput and rate-of-rise methods. The magnetite coating yielded 5× lower water outgassing at room temperature, but this advantage disappeared after 80 °C baking. After full thermal conditioning (400 °C/48 h prebake followed by 150 °C/96 h and 200 °C/110 h), bare steel achieved 25× lower hydrogen outgassing than the magnetite-coated chamber (9.6 × 10¿¹6 Torr·L·s¿¹·cm¿²) and >99% H2 purity with carbon species below RGA detection. Monte Carlo molecular flow simulations of a CEBAF photogun beamline (96 scenarios) showed that replacing 304L stainless steel with AISI 1020 reduces equilibrium H2 pressure by a factor of 833; a single 304L electrode contributes 98.8% of the gas load despite occupying only 9.1% of the internal surface area. A 500-m Einstein Telescope beampipe screening showed that corrugated bellows contribute 18% of the gas load from only 0.7% of the surface area. A five-model adsorption isotherm framework applied to 22 pumpdown datasets (164 fits with AR(1)-GLS correction) established that the experimental protocol, not the material, controls isotherm identifiability: Dubinin–Radushkevich wins isothermal pipe pumpdowns; Langmuir wins thermally dominated chamber bakes. Cross-dataset joint fitting of the AISI 1020 pipe pumpdowns yielded an H2 diffusion activation energy Ed = 7.24 ± 1.28 kcal·mol¿¹, consistent with trap dominated diffusion in commercial low-carbon steels. Two companion innovations were developed: a Variable Conductance Device (VCD, patent pending IDF-00723) for XHV outgassing measurement, and VacuumDesignerPro (VDP), a MATLAB-based design tool validated against LIGO benchmarks.

Al-Allaq, Aiman H [Old Dominion University]↗

Improved Bakeout Chambers Within Vacuum Chambers

Improved bakeout chamber incorporates hardware features that, in conjunction with improved bakeout procedure, reduce spurious contamination and increase accuracy of contamination measurements. When operated according to revised bakeout procedure, they yield measurements of contamination on vacuum-bake test articles more accurate than available previously, and potential for post-bake recontamination of vacuum-baked articles reduced. These chambers improved versions of one described in "Bakeout Chamber Within Vacuum Chamber" (NPO-18959). By enclosing test article in enclave and keeping walls of enclave hotter than test article during bakeout, one prevents condensation of contaminants on inner walls of enclave.

Johnson, Kenneth R.↗

Carbon XANES Data from Six Aerogel Picokeystones Cut from the Top and Bottom Sides of the Stardust Comet Sample Tray

Great care and a large effort was made to minimize the amount of organic matter contained within the flight aerogel used to collect Comet 81P/Wild 2 samples. Even so, by the very nature of the production process and silica aerogel s affinity for volatile organics keeping silica aerogel free from organics is a monumental task. Silica aerogel from three production batches was flown on the Stardust sample return mission. All 3 types had layered densities varying from 5mg/ml to 50 mg/ml where the densest aerogel was farthest away from the collection area. A 2 step gelation process was used to make the flight aerogel and organics used in this process were tetraethylorthosilicate, ethanol and acetonitrile. Both ammonium hydroxide and nitric acid were also used in the aerogel production process. The flight aerogel was baked at JPL at 300 C for 72 hours, most of the baking was done at atmosphere but twice a day the oven was pumped to 10 torr for hour [1]. After the aerogel was baked it was stored in a nitrogen purged cabinet until flight time. One aerogel cell was located in the SRC away from any sample collection area as a witness to possible contamination from out gassing of the space craft, re-entry gases and any other organic encounter. This aerogel was aerogel used in the interstellar collection sample tray and is the least dense of the 3 batches of aerogel flown. Organics found in the witness tile include organics containing Si-CH3 bonds, amines and PAHS. Besides organic contamination, hot spots of calcium were reported in the flight aerogel. Carbonates have been detected in comet 81P/Wild2 samples . During preflight analyses, no technique was used to analyze for carbonates in aerogel. To determine if the carbonates found in 81P/Wild2 samples were from the comet, it is necessary to analyze the flight aerogel for carbonate as well as for organics.

Wirick, S.↗

Effect of Preconditioning and Soldering on Failures of Chip Tantalum Capacitors

Soldering of molded case tantalum capacitors can result in damage to Ta205 dielectric and first turn-on failures due to thermo-mechanical stresses caused by CTE mismatch between materials used in the capacitors. It is also known that presence of moisture might cause damage to plastic cases due to the pop-corning effect. However, there are only scarce literature data on the effect of moisture content on the probability of post-soldering electrical failures. In this work, that is based on a case history, different groups of similar types of CWR tantalum capacitors from two lots were prepared for soldering by bake, moisture saturation, and longterm storage at room conditions. Results of the testing showed that both factors: initial quality of the lot, and preconditioning affect the probability of failures. Baking before soldering was shown to be effective to prevent failures even in lots susceptible to pop-corning damage. Mechanism of failures is discussed and recommendations for pre-soldering bake are suggested based on analysis of moisture characteristics of materials used in the capacitors' design.

multilayer ceramic capacitor (MLCC)↗

CONTAMINATION CONTROL FOR ULTRA-SENSITIVE LIFE DETECTION SCIENCE MISSIONS

"This study report summarizes technological developments in science-required contamination control for cost-capped, life-detection missions in the Solar System. Technology advances focus on developing implementable strategies to restrict contamination of the spacecraft and instruments by the launch vehicle hardware. Secondary bake out operations during cruise further reduce molecular contaminants down to femtomolar levels in the sample path. The study validated a full-spacecraft, deployable barrier design as an effective strategy to isolate the spacecraft from the pre-launch processing and launch environment (e.g., fairing acoustic materials). It accommodates late mounting of RTGs and other required prelaunch activities. A new, high-fidelity physics, contamination-transport model for particles (including cells and their parts) and science-relevant molecules (e.g., possible biomolecules) was developed to validate the barrier concept. Importantly, this model takes into account the physics of extremely clean surfaces achieved by the best traditional contamination engineering. The ability to deal with very low levels of particulate and molecular contamination makes this model unique among standard contamination modeling approaches. Modeling also demonstrated that a high-temperature bake out during interplanetary cruise of the sample collector that comprises the largest surface area in the sample path for an Enceladus orbiter reference mission, was extremely effective. This study included the evaluation of other details necessary for an effective contamination control strategy for life detection missions including feasibility of achieving parts per trillion level cleanliness for semi-volatile hydrocarbons in nitrogen purge gas, identification of launch vehicle services required for the baseline contamination control, and defining additional contamination control measures to be taken during launch operations. Key results of the study are: • New spacecraft barrier design that accommodates RTGs is readily cleanable and repairable. Deployment of a 1/3 scale model was successfully demonstrated. • The barrier reduces particle contamination (likely biological) from fairing to spacecraft by 1e-2 to 1e-3. • On-cruise bake-out of critical surfaces significantly reduced molecular contamination (by as much as 1e-12). Subsequently, the probability of a surface contamination particle being transported to an instrument by an ice particle is less than 5.1e-5 (for microbes specifically, 4.39e-10). The report concludes that a full-spacecraft barrier designed specifically for life-detection missions that require stringent control of particulate and molecular contaminates is an effective means of mitigating risks of false positive and negative results for life signature investigations. Further, secondary cleaning steps for critical sections of the sample path can be highly effective at reducing molecular contaminants to low femtomolar levels."

Contamination↗

Contamination Control for Ultra-Sensitive Life-Detection Missions

"This study report summarizes technological developments in science-required contamination control for cost-capped, life-detection missions in the Solar System. Technology advances focus on developing implementable strategies to restrict contamination of the spacecraft and instruments by the launch vehicle hardware. Secondary bake out operations during cruise further reduce molecular contaminants down to femtomolar levels in the sample path. The study validated a full-spacecraft, deployable barrier design as an effective strategy to isolate the spacecraft from the pre-launch processing and launch environment (e.g., fairing acoustic materials). It accommodates late mounting of RTGs and other required prelaunch activities. A new, high-fidelity physics, contamination-transport model for particles (including cells and their parts) and science-relevant molecules (e.g., possible biomolecules) was developed to validate the barrier concept. Importantly, this model takes into account the physics of extremely clean surfaces achieved by the best traditional contamination engineering. The ability to deal with very low levels of particulate and molecular contamination makes this model unique among standard contamination modeling approaches. Modeling also demonstrated that a high-temperature bake out during interplanetary cruise of the sample collector that comprises the largest surface area in the sample path for an Enceladus orbiter reference mission, was extremely effective. This study included the evaluation of other details necessary for an effective contamination control strategy for life detection missions including feasibility of achieving parts per trillion level cleanliness for semi-volatile hydrocarbons in nitrogen purge gas, identification of launch vehicle services required for the baseline contamination control, and defining additional contamination control measures to be taken during launch operations. Key results of the study are: • New spacecraft barrier design that accommodates RTGs is readily cleanable and repairable. Deployment of a 1/3 scale model was successfully demonstrated. • The barrier reduces particle contamination (likely biological) from fairing to spacecraft by 1e-2 to 1e-3. • On-cruise bake-out of critical surfaces significantly reduced molecular contamination (by as much as 1e-12). Subsequently, the probability of a surface contamination particle being transported to an instrument by an ice particle is less than 5.1e-5 (for microbes specifically, 4.39e-10). The report concludes that a full-spacecraft barrier designed specifically for life-detection missions that require stringent control of particulate and molecular contaminates is an effective means of mitigating risks of false positive and negative results for life signature investigations. Further, secondary cleaning steps for critical sections of the sample path can be highly effective at reducing molecular contaminants to low femtomolar levels."

contamination, life detection, barrier, modeling↗