Application of a Multi-Channel Flash X-ray System for Dynamic Computed Tomography and Time-Resolved Observation of Detonation Failure
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Engineering unit submodule batteries (EUSB) the 360V, 28kWh EAPU battery were designed and assembled by COM DEV. These submodules consist of Sony Li-Ion 18650HC cells in a 5P-41S array yielding 180V, 1.4 kWh. Tests of these and of substrings and single cells at COM DEV and at JSC under various performance and abuse conditions demonstrated that performance requirements can be met. The thermal vacuum tests demonstrated that the worst case hot condition is the design driver. Deficiencies in the initial diode protection scheme of the battery were identified as a result of test failures. Potential solutions to the scheme are under development and will be presented.
Solid polymer electrolytes based on plastic crystals are promising for solid-state sodium metal (Na 0 ) batteries, yet their practicality has been hindered by the notorious Na 0 -electrolyte interface instability issue, the underlying cause of which remains poorly understood. Here, in this study, by leveraging a model plasticized polymer electrolyte based on conventional succinonitrile plastic crystals, we uncover its failure origin in Na 0 batteries is associated with the formation of a thick and non-uniform solid electrolyte interphase (SEI) and whiskery Na 0 nucleation/growth. Furthermore, we design a new additive-embedded plasticized polymer electrolyte to manipulate the Na 0 deposition and SEI formulation. For the first time, we demonstrate that introducing fluoroethylene carbonate (FEC) additive into the succinonitrile-plasticized polymer electrolyte can effectively protect Na 0 against interfacial corrosion by facilitating the growth of dome-like Na 0 with thin, amorphous, and fluorine-rich SEIs, thus enabling significantly improved performances of Na//Na symmetric cells (1,800 h at 0.5 mA cm −2 ) and Na//Na 3 V 2 (PO 4 ) 3 full cells (93.0 % capacity retention after 1,200 cycles at 1 C rate in coin cells and 93.1 % capacity retention after 250 cycles at C/3 in pouch cells at room temperature). Our work provides valuable insights into the interfacial failure of plasticized polymer electrolytes and offers a promising solution to resolving the interfacial instability issue.
Battery cell voltage scanners have been previously used in low voltage spacecraft applications. In connection with future missions involving an employment of high-power high voltage power subsystems and/or autonomous power subsystem management for unattended operation, it will be necessary to utilize battery cell voltage scanners to provide battery cell voltage information for early detection of impending battery cell degradation/failures. In preparation for such missions, a novel battery cell voltage scanner design has been developed. The novel design makes use of low voltage circuit modules which can be applied to high voltage batteries in a building block fashion. A description is presented of the design concept and test results of the high voltage battery cell scanner, and its operation with an autonomously managed power subsystem is discussed.
Ways in which failure can occur in reduced-order, orbit determination filter, error covariance calculations are discussed. In the context of this article, reduced-order filters denote nonoptimal filters which include fixed levels of uncertainty in some parameters of the measurement models or in the spacecraft dynamical model which are not explicitly estimated in the filter equations. Failure is defined as an increase in the orbit determination covariance with the addition of data or as an unreasonable growth in the covariance with time, i.e., nonasymptotic behavior of the covariance. Some simple, known cases of failure are discussed along with their traditional remedies. In addition, more modern remedies are discussed which are currently under development at the Jet Propulsion Laboratory. The article first describes the known problems of reduced-order filters when they are employed for orbit determination, and their traditional remedies. Then, having defined these, the relevancy and desirability of the more modern remedies are made apparent.
Performance degradation of ternary layered oxide cathodes largely originates from their loss of structural integrity in cyclic usage. Mechanical damage, such as intergranular fracture of the active particles, is not only a mechanical cleavage process but also interferes with electrochemical kinetics such as infiltration of liquid electrolyte, surface corrosion of the constituent primary particles, and may eventually isolate the primary grains from the electron conducting network. Here, in this work, we develop a computational framework that integrates electrochemistry of a LiNi x Mn y Co 1−x−y O 2 (NMC) composite cathode with mechanical damage of the active particles. To fully examine the intricate chemomechanical behavior of the electrode, we evaluate the effects of the anisotropic material properties, the influence of mechanical potential on Li transport, and the concurrent intergranular fracture and electrolyte penetration along the grain boundaries upon multiple cycles. Electrolyte infiltration benefits capacity retention but aggravates further mechanical damage by corrosion. Structural failure mostly occurs in the first charging due to the anisotropic mechanical strain between the primary grains, while the resulting damage remains stable in the later few cycles. The results are consistent with experimental observations and the integration of electrochemistry and mechanical failure enables a step further understanding of the complex mechanism of battery degradation.
Extensive research has been reported in the literature to characterize the failure mode of dry sand using various experimental techniques such as surface optical imaging, photo-elastic materials, three-dimensional (3D) computed tomography (CT), and 3D synchrotron micro-computed tomography (SMT). However, there is a limited literature about the behavior of saturated sand. This paper presents the results of axisymmetric triaxial compression (ATC) experiments that were conducted on saturated sand specimens. The behavior of specimens composed of a uniform sand with grain size between US sieves #40 and #50 is compared to specimens conducted on the same sand that has a wider gradation. 3D SMT technique was used to acquire 3D scans while shearing the specimens to probe localized events that are completely missed or misinterpreted when analyzing ATC measurements based on global standard measurements. The results show a higher effective principal stress ratio (EPSR) for the non-uniform specimen and a thicker shear band when compared to uniform specimen.
Electric aviation faces a major challenge of avoiding potentially catastrophic consequences of the battery’s thermal runaway while keeping the weight of the battery low. Detection of early warning signals of battery failures requires accurate monitoring of the battery’s health throughout its lifespan. However, identifying the parameters of the battery from field data is notoriously difficult. We investigate this problem within the framework of modeling the temperature dynamics of a Li-ion cell during tests simulating loading in electric aircraft flights. It is found that the parameters of a higher-fidelity physics-based thermal model cannot be identified from the simulated flight data. To resolve this issue, we reduce the higher-fidelity thermal model to a model with fewer parameters. The resulting reduced-order model can predict temperature dynamics accurately and is identifiable throughout the cell’s lifespan which allows using the model’s parameters to monitor the state-of-health of the aging cell and detect anomalies in thermal behavior.
The Soyuz‑1 accident remains one of the most consequential parachute related failures in human spaceflight history and provides enduring lessons for modern Entry, Descent, and Landing (EDL) system design. Occurring during the height of the Cold War and the Space Race, the mission unfolded under extraordinary political and schedule pressure as the Soviet Union sought to maintain its early leadership in space achievements following the death of chief designer Sergei Korolev. Despite unresolved propulsion, electrical, and parachute system deficiencies, Soyuz‑1 proceeded to launch and immediately encountered critical inflight anomalies, including a failed solar panel deployment, attitude control issues, and communication dropouts. Upon reentry, a malfunction in the parachute system, driven by a primary main canopy that failed to deploy, and subsequent entanglement of the reserve main canopy with the primary drogue parachute, resulted in insufficient deceleration and the fatal crash of cosmonaut Vladimir Komarov. Subsequent investigations revealed deep rooted cultural and organizational issues within the Soviet space program, including inadequate testing, suppression of dissent, undocumented last minute design changes, and the absence of integrated parachute system verification. More than 200 design flaws were identified after the accident, and firsthand accounts, including those from Yuri Gagarin, highlighted widespread concern prior to launch. Over time, the Soviet program implemented substantial reforms: systematic design corrections, rigorous process documentation, and an extensive series of drop tests that ultimately transformed the Soyuz system into one of the world’s most reliable human-rated return vehicles. This paper examines the technical architecture of the Soyuz‑1 parachute system, reconstructs the likely deployment sequence and failure mechanism, and analyzes the cultural contributors that shaped the accident. The study draws parallels to modern spacecraft parachute development, emphasizing the critical importance of integrated system testing, transparent engineering culture, and continuous hardware surveillance. These lessons remain directly relevant to today’s NASA and Commercial Crew Programs (CCP), where the Government continues to refine its understanding of aggregate risk and strengthen overall astronaut safety in the face of increasingly complex parachute systems.
Solid-state batteries (SSBs) promise a decisive advance beyond conventional Li-ion systems, yet their development remains constrained by persistent solid–solid interfacial instabilities that degrade performance and durability. Interfaces between solid electrolytes and both cathodes and Li metal often exhibit poor wettability, limited physical contact, and high charge–transfer resistance, leading to chemical decomposition, mechanical failure, and impedance growth. Overcoming these limitations requires interphase engineering with atomic-scale precision—capabilities that conventional coating methods cannot reliably deliver. Atomic layer deposition (ALD) and molecular layer deposition (MLD) uniquely meet this need by enabling ultrathin, conformal, and composition-tunable films that stabilize reactive surfaces, suppress parasitic reactions, and regulate Li-metal morphology. Importantly, this Perspective highlights ALD/MLD systems that have already demonstrated effectiveness in liquid-electrolyte cells and discusses how these validated strategies can be deliberately translated to solid-state architectures. By grounding future directions in experimentally proven concepts rather than speculative hypotheses, we outline how atomic- and molecular-scale design principles can accelerate the development of robust, high-performance SSB technologies.
Over a period of some 5 years Canadian Astronautics Limited (CAL) has developed a system to autonomously manage, and thus prolong the life of, secondary storage batteries. During the development, the system was aimed at the space vehicle application using nickel cadmium batteries, but is expected to be able to enhance the life and performance of any rechargeable electrochemical couple. The system handles the cells of a battery individually and thus avoids the problems of over, and under, drive that inevitably occur in a battery of cells managed by an averaging system. This individual handling also allow cells to be totally bypassed in the event of failure, thus avoiding the losses associated with low capacity, partial short circuit, and the catastrophe of open circuit. The system has an optional capability of managing redundant batteries simultaneously, adding the advantage of on line reconditioning of one battery, while the other maintains the energy storage capability of the overall system. As developed, the system contains a dedicated, redundant, microprocessor, but the capability exists to have this computing capability time shared, or remote, and operating through a data link. As adjuncts to the basic management system CAL has developed high efficiency, polyphase, power regulators for charge and discharge power conditioning.
Anode-free lithium batteries offer promising advantages, including increased energy density and the ability to address common mechanistic failures within the cell, thus increasing safety. One way that can make this possible is to control lithium nucleation. This could be achieved by reducing the overpotential required and implanting lithophilic nucleation sites in an anodic interlayer to aid in lithium ion transport and plating. The concept has been utilized in solid-state battery systems where electrolytes are solids with further improved safety and structural longevity. In this presentation, we discuss the use of a silver-holey graphene-based anodic interlayer that can be fabricated via direct dry compression without the use of solvent or binder. The addition of silver to the holey graphene matrix creates a route to lithium plating via a lower-energy intermediate. This idea is supported by the presence of a lithium-silver alloy that forms during the activation step. It is understood that the embedded silver acts as a nucleation site for lithium ions, thereby assisting in even plating. This control, combined with the added cushion of the holey graphene itself, can help reduce dendrite formation, ultimately increasing the safety and lifetime of the solid-state batteries.
Lithium-ion (Li-ion) batteries can deliver electrical power across a large range of applications, and large format versions of these batteries are common in aerospace for their low mass and energy dense properties. Li-ion cells usage has increased as they are more power dense than fuel cells and have overall higher performance over lead-acid/NiCd batteries. However, Li-ion cells can experience Thermal Runaway (TR) via electro-chemical, mechanical, or thermal abuse. TR is a phenomenon where the stored energy in a cell is rapidly released along with vented gases and other effluents. A cell is generally determined to be in TR if its internal heat generation has surpassed its ability to dissipate that heat. If a Li-ion cell enters TR, propagation within the battery may occur. Propagation is the chain reaction that can occur to nearby cells due to a cell that has entered TR initially. Understanding a battery’s susceptiveness to propagation is necessary to evaluate risks associated with TR phenomenon. To determine if a battery is designed in a sufficient manner to prevent battery propagation if single cell TR occurs, testing and thermal analysis of the battery must be conducted. The presentation for TFAWS 2026 will cover considerations for battery TR thermal analysis, such as: testing methods, influences on the cells, failure mechanisms, and TR parameters. This presentation will include a walkthrough of an example battery TR thermal analysis, and the results thereof.
Abstract Gas evolution from high‐nickel layered oxide cathodes (>90% Ni) remains a major issue for their practical application. Gaseous species, such as CO 2 , O 2 , and CO, that are evolved at high states of charge (SOC) worsen the overall safety of batteries, as pressure build‐up within the cell may lead to cell rupture. Since these gasses are produced during cathode degradation, tracking the formation of gasses is also important in diagnosing cathode failure. Online electrochemical mass spectrometry (OEMS) is a powerful in situ technique to study gas evolution from the cathode during high‐voltage charge. However, the differences in the OEMS experimental setups between different groups make it challenging to compare results between groups. In this perspective, the various factors that influence gas evolution based on the OEMS results collected in this group are presented. The focus is on the conditions that lead to gas release, with a particular emphasis on reactive oxygen formation and subsequent chemical reactions with the electrolyte. Promising strategies, such as electrolytes, compositional tuning, and surface coatings that are effective at suppressing gas evolution from the cathode are highlighted. Critical insights into mitigating cathode degradation and gas evolution are provided to guide the development of safer, high‐energy batteries.
In November 1990, an inspection visit was made to the residential lighting photovoltaic systems that had been installed approximately one year before in the rural communities of the Municipality of Pinotepa de Don Luis, in the State of Oaxaca. The main purpose of the visit was to evaluate the physical and operational status of these systems. The systems typically consist of a photovoltaic module with a capacity of 30 or 35 Watts, an automotive type battery, an indicator of the status of charge of the battery, 3 fluorescent lamps and the corresponding installation, including cables, connection or outlet box and switches. It can be seen that the systems are in good physical condition and do not show any signs of intentionally caused damage. However, the incidence of failures is higher than what had been expected; therefore the operational status of these systems is considered to be below a level that could be accepted, with a tendency to getting worse. The main problem that has been detected is the lack of automatic charge controllers. This problem has caused other important failures. Serious deficiencies were appreciated in the installations, which show evidence of the poor workmanship of the installers. The lack of system standardization is evident, both regarding the components and the installation. As a consequence, there are technical factors which indicate that the installed systems will keep deteriorating at a rate faster than normal, and will stop operating in a short time unless urgent preventive and corrective measures are taken. The attitude of the users with respect to the systems is generally positive. However, there are elements that make the correct operation and maintenance of these systems a very difficult task. The users did not receive any training regarding the best way to operate and take care of their systems, nor any other information in relation to their technical limitations.
After the rollout of Space Shuttle Discovery in April 2005 in preparation for return-to-flight, there was a failure of the Orbiter (OV-103) helium signature leak test in the gaseous hydrogen (GH2) system. Leakage was attributed to the Flow Control Valve (FCV) in Main Engine 3. The FCV determined to be the source of the leak for OV-103 is designated as LV-58. The nitrile/Buna N rubber O-ring seal was removed from LV-58, and failure analysis indicated radial cracks providing leak paths in one quadrant. Cracks were eventually found in 6 of 9 FCV O-rings among the three Shuttle Orbiters, though none were as severe as those for LV-58, OV-103. Testing by EM10 at MSFC on all 9 FCV O- rings included: laser dimensional, Shore A hardness and properties from a dynamic mechanical analyzer (DMA) and an Instron tensile machine. The following test data was obtained on the cracked quadrant of the LV-58, OV-103 O-ring: (1) the estimated compression set was only 9.5%, compared to none for the rest of the O-ring; (2) Shore A hardness for the O.D. was higher by almost 4 durometer points than for the rest of the O-ring; and (3) DMA data showed that the storage/elastic modulus E was almost 25% lower than for the rest of the O-ring. Of the 8 FCV O-rings tested on an Instron, 4 yielded tensile strengths that were below the MIL spec requirement of 1350 psi-a likely influence of rubber cracking. Comparisons were made between values of modulus determined by DNA (elastic) and Instron (Young s). Each nitrile/Buna N O-ring used in the FCV conforms to the MIL-P-25732C specification. A number of such O-rings taken from shelf storage at MSFC and Kennedy Space Center (KSC) were used to generate a reference curve of DMA glass transition temperature (Tg) vs. shelf storage time ranging from 8 to 26 years. A similar reference curve of TGA onset temperature (of rubber weight loss) vs. shelf storage time was also generated. The DMA and TGA data for the used FCV O-rings were compared to the reference curves. Correlations were also made between the DMA modulus (at 22 C) and Shore A hardness for all 9 of the FCV O-rings used among the three Shuttle Orbiters. The radial cracking in the FCV O-rings was determined to be due to ozone attack, as nitrile/Buna N rubber is susceptible to such attack. Nitrile/Buna N material under MIL-P25732C should be used in a hydraulic fluid environment to help protect it from cracking. However, the FCV O-rings were used in an air only environment. The FCV design has as much as a 9-mil gap that allows the O.D. of the O-ring to be directly exposed to ozone, pressurized air and some elevated temperatures, accelerating the weathering process that leads to O-ring cracking. Space Shuttle flights will likely not continue past 2010. Therefore, Shuttle management decided to continue using the nitrile/Buna N material for the FCVs, but have each O-ring replaced after 3 years to minimize any chances for crack initiation.
A project is underway to develop a consistent set of material properties, impact test data, and failure analysis for a variety of metallic aircraft materials that can be used to develop improved impact failure and deformation models. This project is jointly funded by the NASA Glenn Research Center and the Federal Aviation Administration William J. Hughes Technical Center. Particular features of this set of data are that all material property and impact test data are obtained using traceable material, the test methods and procedures are extensively documented, and all the raw data are available. Four parallel efforts are currently underway: measurement of material deformation and failure response over a wide range of strain rates and temperatures, failure analysis of material property specimens and impact test articles, development of improved numerical modeling techniques for deformation and failure, and impact testing of flat panels and substructures for model validation. This report describes impact testing performed on 410 stainless steel sheet and plate samples of different thicknesses with two different types of projectiles, one a regular cylinder and one with a more complex geometry incorporating features representative of a jet engine fan blade. Data from this testing will be used in validating material models developed under this program. The material tests and the material models developed in this program will be published in separate reports.
Characterizing the morphology of lithium (Li) is crucial for developing long-lasting lithium metal batteries. It is well established that more uniform Li deposition correlates with better cell performance. Li morphology is often characterized through qualitative analysis of scanning electron microscopy (SEM) images; however, there are no widely accepted metrics to quantitatively describe deposition uniformity. Here, we propose a framework to quantify uniformity through SEM image analysis via the index of dispersion (ID) metric, which is defined and presented in the context of Li metal batteries. We also explore experimental impacts of sampling protocols onIDmeasurements. Our results demonstrate that theIDmetric is highly sensitive to variations in deposition uniformity, including the coexistence and uniformity of multiple morphologies, uniformity within a single morphology, and particle size distribution uniformity. Furthermore, it is demonstrated that uniformity, as measured by theID, can be related to the average potential of Li||Li symmetric cells over cycling. Higher capacity cycling leads to more pronounced changes in bothIDand average cell potential. Local minima/maxima are found consistently in bothIDand average cell potential immediately before cells short-circuit, which we suggest may indicate a collapse of the microstructure prior to failure. We put forward this framework as a more robust approach to quantify Li deposition uniformity, advancing the development of Li metal batteries that are safer and longer lasting.