Search NASA⌕ Search

SEARCH · Search NASA

Results for “cascade control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A cascaded coding scheme for error control

A cascaded coding scheme for error control was investigated. The scheme employs a combination of hard and soft decisions in decoding. Error performance is analyzed. If the inner and outer codes are chosen properly, extremely high reliability can be attained even for a high channel bit-error-rate. Some example schemes are studied which seem to be quite suitable for satellite down-link error control.

Kasami, T.↗

A cascaded coding scheme for error control

A cascade coding scheme for error control is investigated. The scheme employs a combination of hard and soft decisions in decoding. Error performance is analyzed. If the inner and outer codes are chosen properly, extremely high reliability can be attained even for a high channel bit-error-rate. Some example schemes are evaluated. They seem to be quite suitable for satellite down-link error control.

Shu, L.↗

Large-signal Stability Analysis of Grid-forming Inverters with Equivalent-circuit Models

Here, this paper proposes an energy function-based direct method for large-signal stability assessment of grid-forming (GFM) inverters leveraging an equivalent-circuit representation of all involved control- and physical-layer dynamics. Three different primary controls, a standard inner-current outer-voltage cascaded-control architecture, output LCL filter, and reference-current saturation limiting are featured in the modeling and analysis framework. A composite energy function for the GFM inverter is obtained by summing up individual energy contributions gleaned from the circuit representation. The approach can readily be generalized to different primary controls, output-filter arrangements, and current limiters since it is based on a circuit-theoretic foundation. Numerical simulations validate the efficacy of the approach in estimating the critical clearing time following a large-signal disturbance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Leveraging Disturbance Observer Based Torque Control for Improved Impedance Rendering with Series Elastic Actuators

The fidelity with which series elastic actuators (SEAs) render desired impedances is important. Numerous approaches to SEA impedance control have been developed under the premise that high-precision actuator torque control is a prerequisite. Indeed, the design of an inner torque compensator has a significant impact on actuator impedance rendering. The disturbance observer (DOB) based torque control implemented in NASA's Valkyrie robot is considered here and a mathematical model of this torque control, cascaded with an outer impedance compensator, is constructed. While previous work has examined the impact a disturbance observer has on torque control performance, little has been done regarding DOBs and impedance rendering accuracy. Both simulation and a series of experiments are used to demonstrate the significant improvements possible in an SEA's ability to render desired dynamic behaviors when utilizing a DOB. Actuator transparency at low impedances is improved, closed loop hysteresis is reduced, and the actuator's dynamic response to both commands and interaction torques more faithfully matches that of the desired model. All of this is achieved by leveraging DOB based control rather than increasing compensator gains, thus making improved SEA impedance control easier to achieve in practice.

Mehling, Joshua S.↗

Cascaded systems and methods for controlling energy use during a demand limiting period

A cascaded control system is configured to control power consumption of a building during a demand limiting period. The cascaded control system includes an energy use setpoint generator and a feedback controller. The energy use setpoint generator is configured to use energy pricing data and measurements of a variable condition within the building to generate an energy use setpoint during the demand limiting period. The feedback controller is configured to use a difference between the energy use setpoint and a measured energy use to generate a control signal for building equipment that operate to affect the variable condition within the building during the demand limiting period.

Wenzel, Michael J.↗

Cascaded systems and methods for controlling energy use during a demand limiting period

A cascaded control system is configured to control power consumption of a building during a demand limiting period. The cascaded control system includes an energy use setpoint generator and a feedback controller. The energy use setpoint generator is configured to use energy pricing data and measurements of a variable condition within the building to generate an energy use setpoint during the demand limiting period. The feedback controller is configured to use a difference between the energy use setpoint and a measured energy use to generate a control signal for building equipment that operate to affect the variable condition within the building during the demand limiting period.

Wenzel, Michael J.↗

Modified Cascading Generalized Inverse Control Allocation

The current aviation revolution towards electric propulsion aircraft (e.g., electric vertical takeoff-and-landing) brings unique control challenges. These vehicles are typically over-actuated (more effectors than desired control outcomes), may require control strategies for the three phases of flight (hover, transition and cruise), and currently have limited electric power availability. These vehicle challenges bring the need for optimal control allocation to the forefront of research. A leading control allocation algorithm, used in current flight vehicles, is the Cascading Generalized Inverse (CGI). Unfortunately, the Cascading Generalized Inverse algorithm is unable to achieve some desired outcomes, it intermittently provides non-optimal allocations, and it may fail to preserve moment direction near maximal achievable outcomes. In this research, the shortcomings of the Cascading Generalized Inverse algorithm are addressed by augmenting the algorithm with Scalar Difference Quadratic unsaturation identification and location at each iteration. Rigorous theory is shown that the Modified Cascading Generalized Inverse performs better at obtaining optimal allocations for all attainable outcomes. Numerical case studies for over-actuated vehicles demonstrate resolution to the aforementioned deficiencies.

Control Allocation↗

Modified Cascading Generalized Inverse Control Allocation

The current aviation revolution towards electric propulsion aircraft (e.g., electric vertical takeoff-and-landing) brings unique control challenges. These vehicles are typically over-actuated (more effectors than desired control outcomes), may require control strategies for the three phases of flight (hover, transition and cruise), and currently have limited electric power availability. These vehicle challenges bring the need for optimal control allocation to the forefront of research. A leading control allocation algorithm, used in current flight vehicles, is the Cascading Generalized Inverse (CGI). Unfortunately, the Cascading Generalized Inverse algorithm is unable to achieve some desired outcomes, it intermittently provides non-optimal allocations, and it may fail to preserve moment direction near maximal achievable outcomes. In this research, the shortcomings of the Cascading Generalized Inverse algorithm are addressed by augmenting the algorithm with Scalar Difference Quadratic unsaturation identification and location at each iteration. Rigorous theory is shown that the Modified Cascading Generalized Inverse performs better at obtaining optimal allocations for all attainable outcomes. Numerical case studies for over-actuated vehicles demonstrate resolution to the aforementioned deficiencies.

Control Allocation↗

Lenalidomide regulates osteocytes fate and related osteoclastogenesis via IL-1β/NF-κB/RANKL signaling

Highlights: • Lenalidomide regulated IL-1β induced osteocyte fate with decreased expressions of RANKL and Sclerostin. • Lenalidomide inhibited subsequent osteoclastogenesis via osteocytes. • Lenalidomide inactivated NF-κB signaling in osteocytes to reduce osteoclast formation. • Lenalidomide attenuated in vivo osteocyte apoptosis and following osteoclastogenesis in osteoarthritis mice. Osteolytic diseases are closely associated with osteocyte fate, indicating a more efficient and crucial role of osteocyte-targeting strategy in inhibiting osteoclastogenesis. Here, we investigated the effects of lenalidomide (Lena) on osteocyte fate in order to regulate osteoclastogenesis via effective cascade-controlling response. Our data revealed that lenalidomide treatment notably rescued IL-1β induced loss of osteocyte viability by inhibiting osteocyte apoptosis with decreased osteoclast-related factors, RANKL and Sclerostin, as demonstrated by the restricted osteoclast formation and reduced bone resorption. Additionally, iTRAQ assay revealed that IL-1β induced activation of NF-κB inhibitor α/β were remarkably downregulated by lenalidomide, showing that lenalidomide impaired NF-κB signaling in osteocytes for inhibiting the expression of osteoclast specific genes in osteoclasts, which was further confirmed by KEGG pathway analysis and Western blot. More interestingly, the in vivo analysis of osteocyte apoptosis and osteoclastogenesis in osteoarthritis mice model indicated a role of lenalidomide in the regulation of osteocyte fate and the consequent inhibition of RANKL-induced osteoclastogenesis. Together, these results suggest that lenalidomide regulates osteocyte fate by attenuating IL-1β/NF-κB signaling, thereby inhibiting RANKL expression for the attenuated osteoclastogenesis both in vitro and vivo, indicating a more efficient remedy among future anti-osteoclastogenesis approaches.

60 APPLIED LIFE SCIENCES↗

Evaluation of supply air temperature control performance with different control strategies at air handling units

Due to its nonlinear feature, supply air temperature control systems at air handling units using single-loop fixed gain control frequently suffer unstable response under dynamic conditions. This paper is aimed at identifying a more effective control strategy to stabilize the valve control and achieve desirable supply air temperature response under various operation conditions by evaluating three control strategies, cascade, gain scheduling and cascade plus gain scheduling controls. Firstly, a control-oriented model is developed and calibrated through open-loop tests. Then, the control issues with single-loop fixed gain control are evaluated through simulations and field tests, which indicates that the system has more aggressive response or becomes unstable under lower load conditions when the chilled-water flow rate is less than 0.1 L/s. Finally, three control strategies are proposed and evaluated. Further, the results reveal that all three proposed controls can achieve better robustness with the integral square error of supply air temperature decreased to 16%, 47% and 5%, respectively, under lower load condition. However, since high-frequency oscillation of the control valve occurs with cascade and cascade plus gain scheduling control, the gain scheduling control is recommended considering a trade-off among the supply air temperature response, valve lifetime and implementation complexity.

42 ENGINEERING↗

Low-Noise High-Performance Current Controllers for Quantum Cascade Lasers

Quantum cascade lasers have ushered in a new era of enhanced capability for chemical sensing. The higher current and voltage demands of these devices over their laser diode counterparts has also ushered in the demand for more capable drive electronics. The current-sensitivity and high frequency response of these devices has continued the desire for low noise, stability and agility enjoyed by the laser diode community for many years. This article addresses the issue of maintaining these characteristics at the currents and voltages required, and presents example performance of current controllers developed by the author at Pacific Northwest National Laboratory, achieving output currents up to two amperes and compliance voltages of 15 volts, with noise levels close to the Johnson noise of the internal resistors, typically a few nA/rt-Hz. Full current depth rapid modulation up to 100 kHz is also demonstrated.

47 OTHER INSTRUMENTATION↗

Note. Switch-Mode Hybrid Current Controllers for Quantum Cascade Lasers

Chemical sensing in the mid-infrared has been revolutionized by the advent of quantum cascade lasers. Their higher current and voltage demands compared to laser diodes however, negatively impact size, weight and power footprint for fieldable systems, particularly in hot environments. This letter presents a switch-mode/linear hybrid controller design, furnishing low-noise drive current up to 2 amperes at compliance voltages up to 15 volts, with noise levels close to the Johnson noise of the internal resistors. Current modulation from near zero to 1.8 Amps is also demonstrated at frequencies up to a kilohertz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Distributed Control Architecture for Cascaded H-Bridge Converter with Integrated Battery Energy Storage

Cascaded H-bridge topology has been used in grid-tied converters for battery energy storage system due to its modular structure. To fully utilize the converter’s modularity, this paper proposes a hierarchical distributed control architecture that consists of primary control, secondary control and battery state of charge (SOC) balancing control. Primary control ensures accurate current tracking while a distributed secondary control based on consensus algorithm is presented to regulate power sharing among modules and is proved to be stable theoretically. Here, a distributed SOC balancing control is further introduced to improve energy efficiency of battery energy storage system. Finally, the hierarchical distributed control strategy is implemented using hardware controllers and a software platform. Besides, a carrier phase shift control is also implemented to achieve multilevel output voltage and harmonic reduction. The experimental results demonstrate the performance of the proposed control scheme effectively.

25 ENERGY STORAGE↗

A Decoupled Droop Control Strategy for Cascaded Multicell Inverter with Low-Frequency Modulation

Cascaded multicell inverter (CMI), featured by its merits of modularity and fault-tolerance, is suitable for medium-voltage applications without using bulky step-up transformers. However, little research has reported grid-forming control of the CMI for the application in the power grid with high penetrations of inverter-interfaced generation. To bridge this research gap, this paper proposes a novel droop control strategy for the CMI with a low-frequency modulation to offer inertia and reactive power support to the power grid. A decoupled Q/V droop control strategy is proposed to eliminate the coupling effect from the P/ω control loop caused by the phase-angle difference between the voltages of the CMI and the grid. The output of the Q/V control loop is set as the reference voltage for each cell of the CMI, which makes the CMI naturally a voltage source to provide a grid-forming capability. Finally, the proposed control strategy shows great active and reactive power regulation and sharing capability, which is validated by simulation on two 100 kW, 2.4 kV CMIs connected in parallel to a power grid.

14 SOLAR ENERGY↗

A new approach to the digital redesign of continuous-time controllers

This paper presents a new method for digital redesign of both a continuous-time state-feedback control law and a cascaded analog controller. The concept of the Law of Mean from the integral calculus is utilized for the development of the equivalent digital controllers from the available analog controllers. A tuning parameter has been introduced into the digitally redesigned control gains so that the digitally controlled states will closely match the original continuous-time states. The proposed digital controllers give excellent performance.

Shieh, Leang-San↗