Results for “cascade control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Output control using feedforward and cascade controllers

An open-loop solution to the output control problem in SISO (single-input, single-output) systems by means of feedforward and cascade controllers is investigated. A simple characterization of feedforward controllers, which achieve steady-state disturbance rejection, is given in a transfer-function setting. Cascade controllers which cause steady-state command tracking are characterized. Disturbance decoupling and command matching controllers are identified. Conditions for existence of feedforward and cascade controllers are given. For unstable systems, it is shown that a stabilizing feedback controller can be used without affecting the feedforward and cascade controllers used for output control; hence, the three controllers can be designed independently. Output control by a combination of feedforward and feedback is discussed.

Seraji, H.↗

Output Control Using Feedforward And Cascade Controllers

Report presents theoretical study of open-loop control elements in single-input, single-output linear system. Focus on output-control (servomechanism) problem, in which objective is to find control scheme that causes output to track certain command inputs and to reject certain disturbance inputs in steady state. Report closes with brief discussion of characteristics and relative merits of feedforward, cascade, and feedback controllers and combinations thereof.

Seraji, Homayoun↗

Cascaded Control for Building HVAC Systems in Practice

Actuator hunting is a widespread and often neglected problem in the HVAC field. Hunting is typically characterized by sustained or intermittent oscillations, and can result in decreased efficiency, increased actuator wear, and poor setpoint tracking. Cascaded control loops have been shown to effectively linearize system dynamics and reduce the prevalence of hunting. This paper details the implementation of cascaded control architectures for Air Handling Unit chilled water valves at three university campus buildings. A framework for implementation the control in existing Building Automation software is developed that requires only a single line of additional code. Results gathered for more than a year show that cascaded control not only eliminates hunting in control loops with documented hunting issues, but provides better tracking and more consistent performance during all seasons. A discussion of efficiency losses due to hunting behavior is presented and illustrated with comparative data. Furthermore, an analysis of cost savings from implementing cascaded chilled water valve control is presented. Field tests show 2.2–4.4% energy savings, with additional potential savings from reduced operational costs (i.e., maintenance and controller retuning).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of feedforward-cascade controllers for multivariable systems

The problems of disturbance decoupling and command matching in linear multivariable systems by means of feedforward and cascade controllers are formulated and solved in a transfer-function setting. It is shown that a necessary and sufficient condition for existence of the required controllers is that the plant zero polynomial is not identically zero and is stable. The required controllers are realized by parallel combination of a proportional-multiple-derivative term and a dynamic term, where the order of the dynamic term does not exceed the number of plant transmission zeros. The control scheme proposed in the paper is composed of a stabilizing feedback controller to enhance system stability, a feedforward controller to achieve disturbance decoupling and a cascade controller to ensure command matching. The three controllers have no effect on each other and can therefore be designed independently. A numerical example is given for illustration.

Seraji, H.↗

Experimental investigation of inlet flow-control cascades for the NFAC 80- by 120-foot Indraft Wind Tunnel

The present investigation of aerodynamic performance for various inlet cascade configurations of an indraft wind tunnel with a short inlet and a low contraction ratio has given attention to the effects of inlet wall shape, antiturbulence screens, and horizontal flow straighteners on test-section flow quality. It is found that an inlet cascade with a tailored vane-splay distribution, antiturbulence screen, and horizontal splitters, will both yield good test section flow quality and furnish isolation from atmospheric winds and turbulence.

Van Aken, Johannes M.↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal digital redesign of cascaded analogue controllers

This paper presents a new, optimal digital redesign technique for finding an optimal cascaded digital controller from the given continuous-time counterpart by minimizing a quadratic performance index. The control gains can be obtained by solving a set of Liapunov equations. The developed optimal cascaded digital controller enables the state and/or outputs of the digitally controlled closed-loop sampled-data system to optimally match those of the original continuous-time closed-loop system at any instant between sampling periods. The developed control law can be implemented using inexpensive and reliable digital electronics with a relatively long sampling period.

Shieh, L. S.↗

Dynamic Load Inrush Current Mitigation in Islanded Microgrids Powered by Grid-Forming Inverters

Grid-forming inverters in a microgrid may trip due to high inrush current caused by a switched connection of an inductive load, e.g., a relatively large induction motor. The control scheme presented in this article includes virtual inertia control method superimposed on the cascaded controller. This article studies the impact of cascaded control scheme used for grid-forming inverter to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. Experimental tests are performed using the virtual inertia method for generating the reference angle for synchronous frame conversion. The experimental performance and sensitivity of the controller to different controller gain settings for a switched connection of an induction motor are discussed. The cascaded operation significantly mitigates the inrush currents while the inverters can perform a normal operation. The performance of the control method is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented.

Gursoy, Mehmetcan↗

Control Effector Unsaturation Modification to the Cascading Generalized Inverse Control Allocation Algorithm

Control allocation has sufficiently progressed such that it is used in front-line fighter aircraft such as the F-18Superhornet and the F-35 Joint Strike Fighter. Published literature shows the F-35 utilizes Nonlinear Dynamic Inversion in conjunction with an Effector Blender that incorporates the Cascading Generalized Inverse control allocation algorithm. While the Cascading Generalized Inverse algorithm is one of the premier generalized inverse methods, it does suffer from three deficiencies. In particular, it suffers from an inability to achieve some desired outcomes, it intermittently provides non-optimal solutions and generally fails to preserve moment direction near maximal achievable moments. An effector unsaturation method based on a Scalar Difference Quadratic was first introduced and implemented on the iterative Prediction Method control allocation algorithm which was shown to consistently achieve optimal (weighted) control allocation solutions throughout the entire Attainable Moment Set while preserving desired moment direction. In this paper, the shortcomings of the Cascading Generalized Inverse algorithm are addressed by augmenting the baseline algorithm with Scalar Difference Quadratic unsaturation identification and location at each iteration. Numerical case studies demonstrate that the Modified Cascading Generalized Inverse algorithm resolves the aforementioned deficiencies.

Michael J Acheson↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A cascaded error control coding scheme for space and satellite communication

An error control coding scheme for space and satellite communications is presented. The scheme is attained by cascading two codes, the inner and outer codes. Error performance of the scheme is analyzed. It is shown that, if the inner and outer codes are chosen properly, extremely high reliability can be achieved even for a high channel bit-error-rate. Several exmple schemes are studied. One of the example schemes is proposed to NASA for satellite or spacecraft downlink error control.

Lin, Shu↗

A cascaded coding scheme for error control

A cascaded coding scheme for error control was investigated. The scheme employs a combination of hard and soft decisions in decoding. Error performance is analyzed. If the inner and outer codes are chosen properly, extremely high reliability can be attained even for a high channel bit-error-rate. Some example schemes are studied which seem to be quite suitable for satellite down-link error control.

Kasami, T.↗

A cascaded coding scheme for error control

A cascade coding scheme for error control is investigated. The scheme employs a combination of hard and soft decisions in decoding. Error performance is analyzed. If the inner and outer codes are chosen properly, extremely high reliability can be attained even for a high channel bit-error-rate. Some example schemes are evaluated. They seem to be quite suitable for satellite down-link error control.

Shu, L.↗

Large-signal Stability Analysis of Grid-forming Inverters with Equivalent-circuit Models

Here, this paper proposes an energy function-based direct method for large-signal stability assessment of grid-forming (GFM) inverters leveraging an equivalent-circuit representation of all involved control- and physical-layer dynamics. Three different primary controls, a standard inner-current outer-voltage cascaded-control architecture, output LCL filter, and reference-current saturation limiting are featured in the modeling and analysis framework. A composite energy function for the GFM inverter is obtained by summing up individual energy contributions gleaned from the circuit representation. The approach can readily be generalized to different primary controls, output-filter arrangements, and current limiters since it is based on a circuit-theoretic foundation. Numerical simulations validate the efficacy of the approach in estimating the critical clearing time following a large-signal disturbance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Leveraging Disturbance Observer Based Torque Control for Improved Impedance Rendering with Series Elastic Actuators

The fidelity with which series elastic actuators (SEAs) render desired impedances is important. Numerous approaches to SEA impedance control have been developed under the premise that high-precision actuator torque control is a prerequisite. Indeed, the design of an inner torque compensator has a significant impact on actuator impedance rendering. The disturbance observer (DOB) based torque control implemented in NASA's Valkyrie robot is considered here and a mathematical model of this torque control, cascaded with an outer impedance compensator, is constructed. While previous work has examined the impact a disturbance observer has on torque control performance, little has been done regarding DOBs and impedance rendering accuracy. Both simulation and a series of experiments are used to demonstrate the significant improvements possible in an SEA's ability to render desired dynamic behaviors when utilizing a DOB. Actuator transparency at low impedances is improved, closed loop hysteresis is reduced, and the actuator's dynamic response to both commands and interaction torques more faithfully matches that of the desired model. All of this is achieved by leveraging DOB based control rather than increasing compensator gains, thus making improved SEA impedance control easier to achieve in practice.

Mehling, Joshua S.↗

Modified Cascading Generalized Inverse Control Allocation

The current aviation revolution towards electric propulsion aircraft (e.g., electric vertical takeoff-and-landing) brings unique control challenges. These vehicles are typically over-actuated (more effectors than desired control outcomes), may require control strategies for the three phases of flight (hover, transition and cruise), and currently have limited electric power availability. These vehicle challenges bring the need for optimal control allocation to the forefront of research. A leading control allocation algorithm, used in current flight vehicles, is the Cascading Generalized Inverse (CGI). Unfortunately, the Cascading Generalized Inverse algorithm is unable to achieve some desired outcomes, it intermittently provides non-optimal allocations, and it may fail to preserve moment direction near maximal achievable outcomes. In this research, the shortcomings of the Cascading Generalized Inverse algorithm are addressed by augmenting the algorithm with Scalar Difference Quadratic unsaturation identification and location at each iteration. Rigorous theory is shown that the Modified Cascading Generalized Inverse performs better at obtaining optimal allocations for all attainable outcomes. Numerical case studies for over-actuated vehicles demonstrate resolution to the aforementioned deficiencies.

Control Allocation↗

Modified Cascading Generalized Inverse Control Allocation

The current aviation revolution towards electric propulsion aircraft (e.g., electric vertical takeoff-and-landing) brings unique control challenges. These vehicles are typically over-actuated (more effectors than desired control outcomes), may require control strategies for the three phases of flight (hover, transition and cruise), and currently have limited electric power availability. These vehicle challenges bring the need for optimal control allocation to the forefront of research. A leading control allocation algorithm, used in current flight vehicles, is the Cascading Generalized Inverse (CGI). Unfortunately, the Cascading Generalized Inverse algorithm is unable to achieve some desired outcomes, it intermittently provides non-optimal allocations, and it may fail to preserve moment direction near maximal achievable outcomes. In this research, the shortcomings of the Cascading Generalized Inverse algorithm are addressed by augmenting the algorithm with Scalar Difference Quadratic unsaturation identification and location at each iteration. Rigorous theory is shown that the Modified Cascading Generalized Inverse performs better at obtaining optimal allocations for all attainable outcomes. Numerical case studies for over-actuated vehicles demonstrate resolution to the aforementioned deficiencies.

Control Allocation↗