Search NASASearch

SEARCH · Search NASA

Results for “case study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Long-Range Transport of Biomass Burning Aerosols from Southern Africa: A Case Study Using Layered Atlantic Smoke Interactions with Clouds Observations

A case study of an incoming biomass burning aerosol plume at Ascension Island is analyzed for the peak of the 2017 fire season using satellites, reanalysis and in situ observations. Measurements from the Atmospheric Radiation Measurement Mobile Facility 1 reveal an abrupt change from relatively clean conditions (~70 parts per billion by volume of carbon monoxide) to a more polluted state (~150 parts per billion by volume of carbon monoxide). Corresponding changes in aerosol size reveal a broadening of size distributions toward larger optical diameters, consistent with the arrival of aged aerosols. Within a 24 h period, black carbon fraction increases ~500% from ~300 ng m e to ~1500 ng m 3 , while light absorption coefficients increase ~300%. Long-range transport of these aerosols is primarily confined between 2 and 5 km above sea level along the northwesterly trade winds. Our results show that the primary driver of increases in aerosol loading over Ascension Island is an intensification of the St. Helena high-pressure system (anticyclone) that leads to a weakening of trade winds and increases westward transport on its northern flank. A better understanding of the complex interactions between air quality, meteorology and long-range aerosol transport is important for future modeling studies focused on aerosol–cloud–radiation interactions over the open ocean and reducing its associated uncertainties.

aerosol size distribution

Training Evaluation: A Case Study of Measuring Impact and ROI

The purpose of this case study was to evaluate the Compliance Officer/Coordinator (CO/CC) training program using Phillips’ approach to training evaluation. INL Learning Performance Consultants (LPCs) applied the ROI Methodology to measure the effectiveness of the CO/CC training program. INL CO/CCs participated in focus groups to provide feedback on their learning, enablers and barriers to applying what they learned, and opportunities to improve the CO/CC learning experience. With collaboration from the CO/CC training program owner, the LPCs demonstrated the business impact and return on investment (ROI) of the CO/CC training program. Included are training program recommendations and lessons learned using the ROI Methodology.

99 GENERAL AND MISCELLANEOUS

A digital twin platform for building performance monitoring and optimization: Performance simulation and case studies

Advancements in sensor technology, data analytics, affordable compute, and communication infrastructure have paved the way for Digital Twin technology in optimizing building operations and controls. This study presents the development of an open and interoperable web-based Digital Twin platform for integrating diverse data streams and facilitating effective user interactions. The platform utilizes modern technologies for the web framework and time-series data management, ensuring scalability and responsiveness. The backend supports seamless integration of diverse data sources and emulators, incorporating data from building sensors and meters, external weather Application Programming Interfaces, and advanced EnergyPlus simulation models of the building and its energy systems including the Distributed Energy Resources that are formulated in Functional Mockup Units. A simulation case study was conducted with FlexLab, a test facility on Lawrence Berkeley National Laboratory campus. The case study includes normal operations, Distributed Energy Resource integration, and power outage scenarios, to illustrate the Digital Twin’s ability to provide critical insights into energy performance and thermal resilience. The results demonstrated the platform’s potential as a decision-support tool for optimizing building energy performance and enhancing resilience against extreme weather events. Future work will focus on deploying the Digital Twin platform to a real building for field validation, extending its capabilities to cover more scenarios such as bidirectional Electric Vehicle interactions, and enhancing user engagement.

EnergyPlus

Added value of site load measurements in probabilistic lifetime extension: a Lillgrund case study

Site-specific fatigue estimation is an essential part of wind turbine lifetime extension, with various methods depending on data availability. The present study compares probabilistic lifetime extension assessment results for rotor blades with and without load measurements. It also addresses two key questions in such assessments: the applicability of the Frandsen model for estimating waked turbulence under complex and mixed wake conditions and the extrapolation of mid-term data over longer time periods. The case study wind turbine is SWT-2.3-93, located at the edge of the Lillgrund wind farm, situated in the Øresund Strait between Denmark and Sweden. The turbine is extensively instrumented, with 5 years of data available from its supervisory control and data acquisition (SCADA) system. Although the Frandsen turbulence estimates deviate in a different manner from measurements at below- and above-rated mean wind speeds, the model remains a conservative approach for fatigue load prediction and reliability. In the current case study, the site-specific assessment using strain gauge measurements yields a 33 % higher annual fatigue reliability index after 35 years compared to a scenario based on the Frandsen estimation combined with ambient environmental data and a generic aeroelastic model. The results also demonstrate that the sensitivity of fatigue reliability to load uncertainty is negligible when load measurements are used directly but relatively high when relying on the Frandsen model in combination with a generic aeroelastic model. Overall, the high variability of the lifetime extension in different scenarios of data availability and accuracy shows the importance and added value of high-quality measurements combined with wind-farm-level SCADA and a model updated in real time (digital twins).

17 WIND ENERGY

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)

Geothermal Heat Pump Case Study: Delta Electronics

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Delta Electronics and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

case study

Multistage economic MPC for systems with a cyclic steady state: A gas network case study

Multistage model predictive control (MPC) provides a robust control strategy for dynamic systems with uncertainties and a setpoint tracking objective. Moreover, extending MPC to minimize an economic cost instead of tracking a pre-calculated optimal setpoint improves controller performance. This paper presents a novel multistage economic nonlinear model predictive control (E-NMPC) framework for dynamic systems operating under uncertainty, with specific application to natural gas transmission networks. A key innovation lies in the integration of cyclic steady-state (CSS) constraints within the multistage MPC formulation, enabling the controller to manage periodic operating conditions commonly observed in energy systems. A Lyapunov-based descent condition is enforced to ensure robust stability of the controller. The multistage economic MPC framework is validated on two gas pipeline case studies, where it successfully minimizes net energy consumption, respects operational constraints under uncertain demand profiles, and guides the network to optimal cyclic operation. The Lyapunov function remains bounded in both case studies, validating the robust stability of multistage E-NMPC.

03 NATURAL GAS

Interdisciplinary Approaches Improve Understanding of Cryptogenic Species: A Historical Case Study of Crayfish in Montana, USA

ABSTRACT Cryptogenic species are those that are not yet “demonstrably native or introduced” in a given area, such as crayfish in western Montana, USA. Delving into evidence from diverse fields can help clarify the status of cryptogenic species. Primary historical sources and indigenous knowledge have informed various ecological questions but are seldom used to clarify the status of cryptogenic species, especially aquatic taxa. We summarize types of evidence used to illuminate species status and offer a case study applying historical sources to cryptogenic crayfish in Montana. We searched for crayfish mentions in dictionaries of indigenous languages and primary historical documents (e.g., travel journals, newspaper accounts, early biological surveys). Early explorer accounts we examined did not mention crayfish in Montana, though they noted them in the nearby Snake River drainage of Idaho and Wyoming. The first mention of crayfish in Montana that we found was from an 1868 newspaper account, probably referencing the upper Missouri River. The species was not noted, but an 1887 article suggested signal crayfish Pacifastacus leniusculus introductions near Bozeman, where non‐native signal crayfish still persist. The earliest crayfish mention we found west of the Great Divide in Montana was from 1934 in Ninepipes and probably referred to non‐native virile crayfish ( Faxonius virilis ). Signal crayfish were not mentioned west of the Divide until a 1944 newspaper account noted their 1937 introduction to the Bitterroot River drainage. The case study demonstrates the value of historical sources in identifying the absence of species and documenting their presence or introduction during periods predating scientific data.

Kennedy, Hampton L. [USDA Forest Service, Southern

Geothermal Heat Pump Case Study: Colorado Mesa University

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Colorado Mesa University and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

case study

Geothermal Heat Pump Case Study: The Century Center

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on The Century Center and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

case study

Geothermal Heat Pump Case Study: Coveyou Scenic Farm

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Coveyou Scenic Farm and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

case study

Geothermal Heat Pump Case Study: Epic Systems Corporation

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Epic Systems Corporation and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

case study

Geothermal Heat Pump Case Study: Montana State University

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Montana State University and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

case study

Geothermal Heat Pump Case Study: Norton Commons, Kentucky

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Norton Commons, Kentucky and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

case study

Geothermal Heat Pump Case Study: Autumn Gardens Apartment Complex

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Autumn Gardens Apartment Complex and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

case study

Geothermal Heat Pump Case Study: College of Southern Idaho

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on College of Southern Idaho and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

case study

Geothermal Heat Pump Case Study: Greensburg, Kansas, City Hall

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Greensburg, Kansas, City Hall and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

case study