Search NASA⌕ Search

SEARCH · Search NASA

Results for “charge detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Writing and Detecting Topological Charges in Exfoliated Fe 5– x GeTe 2

Fe 5–x GeTe 2 is a promising two-dimensional (2D) van der Waals (vdW) magnet for practical applications, given its magnetic properties. These include Curie temperatures above room temperature, and topological spin textures–TST (both merons and skyrmions), responsible for a pronounced anomalous Hall effect (AHE) and its topological counterpart (THE), which can be harvested for spintronics. Here, we show that both the AHE and THE can be amplified considerably by just adjusting the thickness of exfoliated Fe 5–x GeTe 2 , with THE becoming observable even in zero magnetic field due to a field-induced unbalance in topological charges. Using a complementary suite of techniques, including electronic transport, Lorentz transmission electron microscopy, and micromagnetic simulations, we reveal the emergence of substantial coercive fields upon exfoliation, which are absent in the bulk, implying thickness-dependent magnetic interactions that affect the TST. We detected a “magic” thickness t ≈ 30 nm where the formation of TST is maximized, inducing large magnitudes for the topological charge density (~6.45 × 10 20 cm –2 ), and the concomitant anomalous (ρ xy A,max ≃22.6 μΩ cm) and topological (ρ xy u,T 1≃5 μΩ cm) Hall resistivities at T ≈ 120 K. These values for ρ xy A,max and ρ xy u,T are higher than those found in magnetic topological insulators and, so far, the largest reported for 2D magnets. Furthermore, the hitherto unobserved THE under zero magnetic field could provide a platform for the writing and electrical detection of TST aiming at energy-efficient devices based on vdW ferromagnets.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Autonomous Tuning and Charge-State Detection of Gate-Defined Quantum Dots

Defining quantum dots in semiconductor-based heterostructures is an essential step in initializing solid-state qubits. With growing device complexity and increasing number of functional devices required for measurements, a manual approach to finding suitable gate voltages to confine electrons electrostatically is impractical. Here, we implement a two-stage device characterization and dot-tuning process, which first determines whether devices are functional and then attempts to tune the functional devices to the single or double quantum-dot regime. We show that automating well-established manual-tuning procedures and replacing the experimenter’s decisions by supervised machine learning is sufficient to tune double quantum dots in multiple devices without premeasured input or manual intervention. The quality of measurement results and charge states are assessed by four binary classifiers trained with experimental data, reflecting real device behavior. We compare and optimize eight models and different data preprocessing techniques for each of the classifiers to achieve reliable autonomous tuning, an essential step towards scalable quantum systems in quantum-dot-based qubit architectures.

Darulova, J↗

Optical activation and detection of charge transport between individual colour centres in diamond

Understanding the capture of charge carriers by colour centres in semiconductors is important for the development of novel forms of sensing and quantum information processing, but experiments typically involve ensemble measurements, often impacted by defect proximity. In this study, we show that confocal fluorescence microscopy and magnetic resonance can be used to induce and probe charge transport between individual nitrogen-vacancy centres in diamond at room temperature. In our experiments, a ‘source’ nitrogen vacancy undergoes optically driven cycles of ionization and recombination to produce a stream of photogenerated carriers, one of which is subsequently captured by a ‘target’ nitrogen vacancy several micrometres away. We use a spin-to-charge conversion scheme to encode the spin state of the source colour centre into the charge state of the target, which allows us to set an upper bound to carrier injection from other background defects. We attribute our observations to the action of unscreened Coulomb potentials producing giant carrier capture cross-sections, orders of magnitude greater than those measured in ensembles.

36 MATERIALS SCIENCE↗

Impact of front-end parameters of the ARCADIA MD3 on charged particle detection

The ARCADIA INFN R&D project developed a Fully Depleted Monolithic Active Pixel Sensor (FD-MAPS) using a customized LFoundry 110 nm CIS process. The first in-beam characterization of the ARCADIA Main Demonstrator 3 (MD3) sensor with 200 $μ$m active thickness has been performed at the Fermilab Test Beam Facility with a 120 GeV proton beam. The Device Under Test (DUT) is tested with a trigger-less telescope composed of two ARCADIA MD3 tracking planes. This early study investigates the effect of the front-end parameters on the tracking performance.

Pantouvakis, C. [Padua U.; INFN, Padua]↗

Particle charge spectrometer

An airflow through a tube is used to guide a charged particle through the tube. A detector may be used to detect charge passing through the tube on the particle. The movement of the particle through the tube may be used to both detect its charge and size.

Fuerstenau, Stephen D.↗

Induction Charge Detector with Multiple Sensing Stages

An induction charge detector with multiple sensing stages has been conceived for use in characterizing sprayed droplets, dust particles, large ionized molecules, and the like. Like related prior single-stage devices, each stage yields a measurement of the electric charge and the time of flight of the particle. In effect, an n-stage sensor yields n independent sets of such measurements from the same particle. The benefit of doing this is to increase the effective signal-to-noise ratio and thereby lower the charge-detection limit and the standard error of the charge measurement.

Gamero-Castano, Manuel↗

Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

Instruments & Instrumentation↗

Large Individual Ion FTICR Measurements from the Mid-1990s Using Reactions for Charge Determination Mass Spectrometry

This article discusses from a personal and present-day perspective the first studies of large highly charged individual molecular ions that were conducted using electrospray ionization (ESI) with Fourier transform ion cyclotron resonance (FTICR) MS in the mid-1990s. These studies are distinguished from current Charge Detection Mass Spectrometry (CDMS) research primarily by their use of individual ion charge state changes due to reactions. Here this work describes the key differences in technologies and methods with present CDMS, and the likely implications of these differences. I also comment on surprising individual ion behavior observed in some measurements involving increases in charge state, as well as their possible basis, and also briefly discuss the potential utility of the reaction-based mass measurement approach used in the context of what might more globally be referred to as ‘Charge Determination Mass Spectrometry’.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct momentum imaging of charge transfer following site-selective ionization

We study ultrafast charge rearrangement in dissociating 2-iodopropane (2-C 3 H 7 I) using site-selective core-ionization at the iodine atom. Clear signatures of electron transfer between the neutral propyl fragment and multiply charged iodine ions are observed in the recorded delay-dependent ion momentum distributions. The detected charge transfer pathway is only favorable within a small (few angstrom), charge-state-dependent spatial window located at C-I distances longer than that of the neutral ground-state molecule. Lastly, these results offer new insights into the physics underpinning charge transfer in isolated molecules and pave the way for a new class of time-resolved studies.

74 ATOMIC AND MOLECULAR PHYSICS↗

A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector

The dual-axis duo-lateral position-sensitive silicon detector was developed to detect charged particles with high quality position and energy resolution. When these detectors were used with conventional signal processing electronics, an empirically determined correction was used to improve energy resolution. In this work, the waveforms from the detector after preamplification are studied in detail to investigate position information contained in the waveforms. A 7.22 MeV/nucleon alpha particle beam was impinged directly on a masked dual-axis duo-lateral detector. Data obtained using a 228 Th alpha particle source was also used. Here, by studying the waveform characteristics that give rise to the position-dependent distortions, a new summed trigger analysis method has been developed to significantly improve linearity in position reconstruction without sacrificing energy resolution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Testing, Operation, and Analysis of a Photosensitive LArTPC

LArTPCs detect charge and light from particle interactions to study neutrinos indirectly. TinyTPC, a compact LArTPC with a pixelated readout system (LArPix), aims to improve energy measurements for low-energy events by enhancing ionization charge collection. It will explore the effects of photosensitive dopants and xenon in liquid argon. Isobutylene, with ionization energy near argon's scintillation energy, efficiently converts scintillation light into a detectable ionization signal.

McCright, Hannah↗

Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles

To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Searching for metastable particles using graph computing

The reconstruction of charged particle trajectories at the Large Hadron Collider and future colliders relies on energy depositions in sensors placed at distances ranging from a centimeter to a meter from the colliding beams. We propose a method of detecting charged particles that decay invisibly after traversing a short distance of about 25 cm inside the experimental apparatus. One of the decay products may constitute the dark matter known to be 84% of all matter at galactic and cosmological distance scales. Our method uses graph computing to cluster spacepoints recorded by two-dimensional silicon pixel sensors into mathematically-defined patterns. The algorithm may be implemented on silicon-based integrated circuits using field-programmable gate array technology to augment or replace traditional computing platforms.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A spacecraft charging study on the SCEX 3 rocket

Instruments on the SCEX 3 rocket payload were used to study charging during electron beam emissions. The data show that electrostatic analyzers can be used to measure vehicle charging and direct beam return currents in dense plasma conditions. The data also show return current dependencies on pitch angle, beam current and beam energy. It is found that if the proper care is taken, ESAs can be used to detect charging on vehicles in low altitude orbits which are contaminated with high levels of outgassing and in dense plasma regimes. These results are particularly important for the TSS-1 electrodynamic tether program where ESAs are being used to determine Shuttle charging levels during tether employment and to look for high fluxes of directly returning electrons during electron generator operations to balance the Shuttle charging.

Mullen, E. G.↗