Search NASA⌕ Search

SEARCH · Search NASA

Results for “compare server power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Performance Evaluation for Modular, Scalable Liquid-Rack Cooling Systems in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 3. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable liquid-rack cooling system in this study. The scope is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Cooling Systems with Hot Aisle Containment in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 2. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable pair of chilled water cooling modules that were tested in a hot/cold aisle environment with hot aisle containment. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy savings and usability of zero-client computing in office settings

This study provides a detailed comparison of the power consumption, usability, and applicability of virtual machines (VMs) - accessed through zero-client devices - and traditional laptop computers in office settings. The study analyzed high-level plug loads across two office spaces, one using traditional laptops, the other using zero clients. In addition, the individual power consumption of four workstations was monitored and compared. Each workstation user switched between using a laptop or zero client for one week and then using the alternate system the second week. Results of the high-level and workstation analysis show that average workstation plug loads are lower for occupants using zero clients. However, this does not include power consumed by the data center managing VMs. This study calculates the affiliated data center power draw of VMs and shows that server-related loads push total zero-client computing energy higher than that of traditional laptops. Finally, a questionnaire was administered to building occupants to determine the appropriateness of zero-client computing for various user groups, with the results indicating that VMs are most appropriate for more basic software functions. The findings of this study suggest that advances in server technology can help improve both the overall efficiency and the usability of zero-client computing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cache Energy Optimization Techniques For Modern Processors

Modern multicore processors are employing large last-level caches, for example Intel's E7-8800 processor uses 24MB L3 cache. Further, with each CMOS technology generation, leakage energy has been dramatically increasing and hence, leakage energy is expected to become a major source of energy dissipation, especially in last-level caches (LLCs). The conventional schemes of cache energy saving either aim at saving dynamic energy or are based on properties specific to first-level caches, and thus these schemes have limited utility for last-level caches. Further, several other techniques require offline profiling or per-application tuning and hence are not suitable for product systems. In this book, we present novel cache leakage energy saving schemes for single-core and multicore systems; desktop, QoS, real-time and server systems. Also, we present cache energy saving techniques for caches designed with both conventional SRAM devices and emerging non-volatile devices such as STT-RAM (spin-torque transfer RAM). We present software-controlled, hardware-assisted techniques which use dynamic cache reconfiguration to configure the cache to the most energy efficient configuration while keeping the performance loss bounded. To profile and test a large number of potential configurations, we utilize low-overhead, micro-architecture components, which can be easily integrated into modern processor chips. We adopt a system-wide approach to save energy to ensure that cache reconfiguration does not increase energy consumption of other components of the processor. We have compared our techniques with state-of-the-art techniques and have found that our techniques outperform them in terms of energy efficiency and other relevant metrics. The techniques presented in this book have important applications in improving energy-efficiency of higher-end embedded, desktop, QoS, real-time, server processors and multitasking systems. This book is intended to be a valuable guide for both newcomers and veterans in the field of cache power management. It will help graduate students, CAD tool developers and designers in understanding the need of energy efficiency in modern computing systems. Further, it will be useful for researchers in gaining insights into algorithms and techniques for micro-architectural and system-level energy optimization using dynamic cache reconfiguration. We sincerely believe that the ``food for thought'' presented in this book will inspire the readers to develop even better ideas for designing ``green'' processors of tomorrow.

Cache energy saving↗

New approach based on group technology for the consolidation problem in cloud computing-mathematical model and genetic algorithm

Resource management is a hotspot issue in distributed systems like cloud computing (CC). It means how to prepare the computational resources, i.e., servers and virtual machines (VMS), to execute the tasks. This paper offers a new approach based on Group Technology (GT)—known as a powerful philosophy for the resource management in cellular manufacturing systems—to deal with the resource management problem in CC. We develop a mathematical model to optimally consolidate the VMs, servers and tasks simultaneously to control several important factors such as task migrations and server load variation, as well as the number of VMs. To test the validity of our proposed model, several small problems are generated randomly and solved by LINGO 9 software. Furthermore, to cope with larger problems, which cannot be solved optimally, a genetic algorithm is proposed. We, finally, compare our methods with the most well-known algorithms in this context, round robin (RR) and first-come, first-served (FCFS) algorithms.

97 MATHEMATICS AND COMPUTING↗

Tropical Cyclone Information System

The JPL Tropical Cyclone Infor ma tion System (TCIS) is a Web portal (http://tropicalcyclone.jpl.nasa.gov) that provides researchers with an extensive set of observed hurricane parameters together with large-scale and convection resolving model outputs. It provides a comprehensive set of high-resolution satellite (see figure), airborne, and in-situ observations in both image and data formats. Large-scale datasets depict the surrounding environmental parameters such as SST (Sea Surface Temperature) and aerosol loading. Model outputs and analysis tools are provided to evaluate model performance and compare observations from different platforms. The system pertains to the thermodynamic and microphysical structure of the storm, the air-sea interaction processes, and the larger-scale environment as depicted by ocean heat content and the aerosol loading of the environment. Currently, the TCIS is populated with satellite observations of all tropical cyclones observed globally during 2005. There is a plan to extend the database both forward in time till present as well as backward to 1998. The portal is powered by a MySQL database and an Apache/Tomcat Web server on a Linux system. The interactive graphic user interface is provided by Google Map.

Li, P. Peggy↗

Application configuration selection for energy-efficient execution on multicore systems

Balanced performance and energy consumption are incorporated in the design of modern computer systems. Several runtime factors, such as concurrency levels, thread mapping strategies, and dynamic voltage and frequency scaling (DVFS) should be considered in order to achieve optimal energy efficiency fora workload. Selecting appropriate run-time factors, however, is one of the most challenging tasks because the run-time factors are architecture-specific and workload-specific. And while most existing works concentrate on either static analysis of the workload or run-time prediction results, we present a hybrid two-step method that utilizes concurrency levels and DVFS settings to achieve the energy efficiency configuration for a worldoad. The experimental results based on a Xeon E5620 server with NPB and PARSEC benchmark suites show that the model is able to predict the energy efficient configuration accurately. On average, an additional 10% EDP (Energy Delay Product) saving is obtained by using run-time DVFS for the entire system. An off-line optimal solution is used to compare with the proposed scheme. Finally, the experimental results show that the average extra EDP saved by the optimal solution is within 5% on selective parallel benchmarks.

97 MATHEMATICS AND COMPUTING↗

Retrofit Energy Analysis and Central Thermal modeling (REACT) v1.0

REACT is a website designed to simplify the analysis and decision-making process for retrofitting existing central plant heating and cooling systems with advanced heat pump technologies. The tool evaluates the technical and economic viability of replacing traditional boilers with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. Retrofitting traditional boiler and chiller systems with water-to-water or air-to-water heat pumps can significantly reduce energy consumption and lower lifecycle costs. The REACT provides: User-Friendly Tools: A user friendly web interface for quick, intuitive analysis accessible to non-experts. Advanced Modeling: A Python-powered engine for detailed parametric studies, optimization, and research applications. Comprehensive Analysis: Lifecycle cost evaluation, energy consumption modeling, and environmental impact assessment. Visual Insights: A variety of plots to visualize system performance and design trade-offs. The engine for the website (REACT) bases on several Python libraries, and the website will be hosted on an ETA server.

Kim, Donghun [Lawrence Berkeley National Laborator↗

Blockchain-Enabled Cyber-Secure Microgrid Control Using Consensus Algorithm: Preprint

This paper proposes a distributed control method based on a consensus algorithm for distributed energy resources (DERs) using blockchain as a secure communication medium for cyber resilience. Each DER communicates with a local blockchain server that is maintained by the distributed ledger technology to allow for securely sharing local measurements among neighboring assets to achieve the global control objectives, i.e., voltage and frequency regulation as well as accurate power sharing among the DERs, including collective grid-forming capability. To prove that the distributed control can retain system stability under a blockchain-induced variable communication delay, Lyapunov function-based stability analysis is carried out. This paper demonstrates the concept on an 11-bus test case developed in MATLAB Simulink, which has been modified from the IEEE 9-bus test case, to study dynamic operations of the five inverter-based DERs working with a blockchain-induced variable delay. The results validate the superior performance of the proposed control method, compared to heavily compromised operations of the other test cases without the security measure, affected by heavy communication delays and communication interruptions.

blockchain↗

Advancing Sustainability in Data Centers: Evaluation of Hybrid Air/Liquid Cooling Schemes for IT Payload Using Sea Water

Abstract-The growth in cloud computing, Big Data, AI and high-performance computing (HPC) necessitate the deployment of additional data centers (DC's) with high energy demands. The unprecedented increase in the Thermal Design Power (TDP) of the computing chips will require innovative cooling techniques. Furthermore, DC's are increasingly limited in their ability to add powerful GPU servers by power capacity constraints. As cooling energy use accounts for up to 40% of DC energy consumption, creative cooling solutions are urgently needed to allow deployment of additional servers, enhance sustainability and increase energy efficiency of DC's. The information in this study is provided from Start Campus' Sines facility supported by Alfa Laval for the heat exchanger and CO 2 emission calculations. The study evaluates the performance and sustainability impact of various data center cooling strategies including an air-only deployment and a subsequent hybrid air/water cooling solution all utilizing sea water as the cooling source. Here we evaluate scenarios from 3 MW to 15+1 MW of IT load in 3 MW increments which correspond to the size of heat exchangers used in the Start Campus' modular system design. This study also evaluates the CO 2 emissions compared to a conventional chiller system for all the presented scenarios. Results indicate that the effective use of the sea water cooled system combined with liquid cooled systems improve the efficiency of the DC, plays a role in decreasing the CO 2 emissions and supports in achieving sustainability goals.

97 MATHEMATICS AND COMPUTING↗

An enhanced partial order curve comparison algorithm and its application to analyzing protein folding trajectories

Background: Understanding how proteins fold is essential to our quest in discovering how life works at the molecular level. Current computation power enables researchers to produce a huge amount of folding simulation data. Hence there is a pressing need to be able to interpret and identify novel folding features from them. Results: In this paper, we model each folding trajectory as a multi-dimensional curve. We then develop an effective multiple curve comparison (MCC) algorithm, called the enhanced partial order (EPO) algorithm, to extract features from a set of diverse folding trajectories, including both successful and unsuccessful simulation runs. The EPO algorithm addresses several new challenges presented by comparing high dimensional curves coming from folding trajectories. A detailed case study on miniprotein Trp-cage [1] demonstrates that our algorithm can detect similarities at rather low level, and extract biologically meaningful folding events. Conclusion: The EPO algorithm is general and applicable to a wide range of applications. We demonstrate its generality and effectiveness by applying it to aligning multiple protein structures with low similarities. For user's convenience, we provide a web server for the algorithm at http:// db.cse.ohio-state.edu/EPO.

59 BASIC BIOLOGICAL SCIENCES↗

I/O Performance Characterization of Lustre and NASA Applications on Pleiades

In this paper we study the performance of the Lustre file system using five scientific and engineering applications representative of NASA workload on large-scale supercomputing systems such as NASA s Pleiades. In order to facilitate the collection of Lustre performance metrics, we have developed a software tool that exports a wide variety of client and server-side metrics using SGI's Performance Co-Pilot (PCP), and generates a human readable report on key metrics at the end of a batch job. These performance metrics are (a) amount of data read and written, (b) number of files opened and closed, and (c) remote procedure call (RPC) size distribution (4 KB to 1024 KB, in powers of 2) for I/O operations. RPC size distribution measures the efficiency of the Lustre client and can pinpoint problems such as small write sizes, disk fragmentation, etc. These extracted statistics are useful in determining the I/O pattern of the application and can assist in identifying possible improvements for users applications. Information on the number of file operations enables a scientist to optimize the I/O performance of their applications. Amount of I/O data helps users choose the optimal stripe size and stripe count to enhance I/O performance. In this paper, we demonstrate the usefulness of this tool on Pleiades for five production quality NASA scientific and engineering applications. We compare the latency of read and write operations under Lustre to that with NFS by tracing system calls and signals. We also investigate the read and write policies and study the effect of page cache size on I/O operations. We examine the performance impact of Lustre stripe size and stripe count along with performance evaluation of file per process and single shared file accessed by all the processes for NASA workload using parameterized IOR benchmark.

Saini, Subhash↗

GPU-accelerated 3D neutron diffusion code based on finite difference method

Finite difference method, as a traditional numerical solution to neutron diffusion equation, although considered simpler and more precise than the coarse mesh nodal methods, has a bottle neck to be widely applied caused by the huge memory and unendurable computation time it requires. In recent years, the concept of General-Purpose computation on GPUs has provided us with a powerful computational engine for scientific research. In this study, a GPU-Accelerated multi-group 3D neutron diffusion code based on finite difference method was developed. First, a clean-sheet neutron diffusion code (3DFD-CPU) was written in C++ on the CPU architecture, and later ported to GPUs under NVIDIA's CUDA platform (3DFD-GPU). The IAEA 3D PWR benchmark problem was calculated in the numerical test, where three different codes, including the original CPU-based sequential code, the HYPRE (High Performance Pre-conditioners)-based diffusion code and CITATION, were used as counterpoints to test the efficiency and accuracy of the GPU-based program. The results demonstrate both high efficiency and adequate accuracy of the GPU implementation for neutron diffusion equation. A speedup factor of about 46 times was obtained, using NVIDIA's Geforce GTX470 GPU card against a 2.50 GHz Intel Quad Q9300 CPU processor. Compared with the HYPRE-based code performing in parallel on an 8-core tower server, the speedup of about 2 still could be observed. More encouragingly, without any mathematical acceleration technology, the GPU implementation ran about 5 times faster than CITATION which was speeded up by using the SOR method and Chebyshev extrapolation technique. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Increasing accessibility to deep learning-based analytics for space biology: pretrained models, transfer learning, and analytics platform development

Biological systems react in complex ways to the stressors of spaceflight, and the data capturing these relationships is concomitantly high-dimensional and complex. Deep learning and machine learning approaches are increasingly popular as an analytical approach for space biosciences, due to their ability to model complex relationships in complex data. However, such approaches often require large datasets and extensive computational resources. New approaches that minimize data sizes and computational power needed to leverage machine learning, and resources that make these approaches accessible, are needed to increase accessibility and adoption of machine learning in the space biosciences. Transfer learning, in which a pretrained model of broad utility is trained on a large dataset, and subsequently reused on downstream applications for which data is more limited, is one approach to minimizing data and computational intensity of deep learning applications. This transfer learning approach results in more performant models in high-dimensional, low-sample-size settings such as space biology, as compared to training models on limited data from scratch. This presentation will outline efforts to generate pretrained models for the space biology community, and highlight transfer learning applications modeling microbial antibiotic resistance during spaceflight. Finally, in order to increase accessibility of these models and tools, as well as others, for the broader space biology community, we present a modeling and analysis platform facilitating machine learning applications in space biology. This platform streamlines machine learning training and analysis in a notebook format, facilitates download and use of space biology data from the NASA GeneLab database, and can be utilized on NASA-hosted servers or downloaded and hosted locally. This effort, as part of the AI4LS (Artificial Intelligence for Life in Space) working group, will increase accessibility, feasibility, and performance of machine learning approaches for the space biology community.

Adrienne Hoarfrost↗

What Can We Learn from One Billion Ground System Log Messages?

Shortage of log-based data in a ground system they have traditionally been the under achievers in a satellite ground system. This is due to several factors: Once log messages scroll out of view on the TTC event console window they are soon forgotten. Application and system log files are scattered across directories within a system, across a multitude of servers, and across one or more databases making access cumbersome. Typical tools to perform log file content searching are generally crude and typically only employed as part of trouble-shooting exercises.As we move towards satellite constellations and fleets and add even more status information, the number of messages keeps growing. One mission now estimates that they could generate 3,000,000 messages per day 1 billion per year - for the life of their mission. What to do with those 1 billion messages? That is the challenge. With the recent technological advances in the management of large data sets, text-based processing, and data analytics, there are now capabilities that we can provide to the ground system engineers and satellite operators to address what we postulate are missed opportunities. Advanced real-time log analysis can allow us to be less reactionary in favor of being more proactive. Analytics goals include the ability to: Identify root cause of unexpected events, failures or error conditions enabled by correlating disparate data. Detect security breaches attempts before they are successful. Help admins ensure IT resources continue running optimally. Identify trends and patterns that may indicate impending failures or error conditions for valuable assets before they happen. Compare satellites in a fleet or constellation in terms of number of alarms, number of command sent to them, etc.. Answer questions like "Are the operations support needs increasing over the past year?" or "Have we seen this combination of alarm conditions before?" But really, once the tools are readily available the users will start realizing what can be done with their new powers. In this presentation we will show the results of analyzing millions of actual mission operations log messages, how the results can be displayed to the user, and how new products now available as open source can be applied to the challenges of large scale time-tagged text-based mission operations messages. Flight operations team members believe that this is a powerful new option for how they assess overall system and space asset health. Technical descriptions of the design, tools, and storage will be provided. One billion messages? Bring'em on!

Orsborne, Sharon↗

On High-Fluence Irradiation Hardening of Nine RPV Surveillance Steels in the UCSB ATR-2 Experiment: Implications for Extended-Life Embrittlement Predictions

Nine archival reactor pressure vessel (RPV) surveillance steels from commercial nuclear power plants were irradiated in the University of California, Santa Barbara Advanced Test Reactor 2 (ATR-2) experiment to evaluate irradiation embrittlement under low-flux surveillance capsule versus higher flux test reactor (ATR-2) conditions. The postirradiation measurements of irradiation hardening, measured as increases in yield stress (Δσy), and corresponding conversions of Δσy to Charpy V-notch 41-J transition temperature shifts (ΔTc) are compared with various embrittlement trend curve (ETC) model predictions for the nine steels. Tensile and converted shear punch and microhardness measurements of Δσy generally show a continuing increase between intermediate and high ATR-2 fluences. The Eason-Odette-Nanstad-Yamamoto and ASTM E900 ETC models underpredict embrittlement at the ATR-2 irradiation condition: irradiation temperature (Ti) of 292°C, neutron fluence (ϕt) of 1.4 × 1020 n/cm2 (E > 1 MeV), and neutron flux (ϕ) of 3.68 × 1012 n/cm2-s. On average, the French FIS and Japanese JAEC ETCs slightly overpredict the ATR-2 data. The increase in Δσy with higher fluence is primarily due to Ni-Mn-Si precipitates, which slowly evolve in both nearly copper-free and copper-bearing steels. Finally, a new Odette-Wells-Almirall-Yamamoto embrittlement model is shown that yields good predictions for the nine steels at high fluences (ϕt > 5.5 × 1019 n/cm2).

Nanstad, Randy↗