Search NASA⌕ Search

SEARCH · Search NASA

Results for “continuous beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

High precision 5 MeV Mott polarimeter

We report on the design and performance of a Mott polarimeter optimized for a nominal 5-MeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) injector. The rf time structure of this beam allows the use of time of flight in the scattered electron detection, making it possible to cleanly isolate those detected electrons that originate from the scattering foil, and resulting in measured scattering asymmetries which are exceptionally stable over a broad range of beam conditions, beam currents, and foil thicknesses. In two separate series of measurements from two different photocathode electron sources, we have measured the Mott scattering asymmetries produced by an approximately 86% transversely polarized electron beam incident on ten gold foils with nominal thicknesses between 50 and 1000 nm. The statistical uncertainty of the measured asymmetry from each foil is below 0.25%. Within this statistical precision, the measured asymmetry was unaffected by ±1-mm shifts in the beam position on the target foil, and by beam current changes and dead-time effects over a wide range of beam currents. The overall uncertainty of our beam polarization measurement, arising from the uncertainty in the value of the scattering asymmetry at zero foil thickness as determined from our fits to the measured asymmetries versus scattering foil thicknesses, the estimated systematic effects, and the (dominant) uncertainty from the calculation of the theoretical Sherman function, is 0.61%. A simulation of the polarimeter using geant4 has confirmed that double scattering in the target foil is the sole source of the dependence of the measured asymmetry on foil thickness, and gives a result for the asymmetry versus foil thickness in good agreement with both our measurements and a simple calculation. Future measurements at different beam energies and with target foils of different atomic numbers will seek to bound uncertainties from small effects such as radiative corrections to the calculation of the polarimeter analyzing power. A simultaneous high-precision measurement of the beam polarization with a different polarimeter, AESOP (Accurate Electron Spin Optical Polarimeter), under development at the University of Nebraska, clearly possible at the CEBAF accelerator, will allow a high-precision comparison of our measured asymmetries with theoretical calculations of the Mott analyzing power. Finally, the improved precision of the current Mott polarimeter along with similar improvements to other Jefferson Lab polarimeters warrants another precision comparison of all of these polarimeters when measuring a beam of the same polarization.

Grames, J. M. (ORCID:0000000193908752)↗

Probing charged lepton flavor violation with a positron beam at CEBAF (JLAB)

The addition of a high intensity 11 GeV polarized positron beam at the Continuous Electron Beam Accelerator Facility (CEBAF) at JLAB would allow for a search of Charged Lepton Flavor Violation (CLFV) via the process $e^+N \rightarrow \mu^+ X$. The proposed Solenoidal Large Intensity Detector (SoLID) spectrometer, in the configuration with muon chambers, would be ideal for such CLFV searches. Various new physics scenarios, including the phenomenologically convenient Leptoquark (LQ) framework, predict CLFV rates that are within reach of current or planned experiments. A positron beam with instantaneous luminosity, ${\cal L}\sim 10^{38}$ cm$^{-2}$s$^{-1}$, could improve on existing HERA limits by two or three orders of magnitude. The availability of positron beam polarization would also allow for distentangling CLFV effects mediated by left-handed vs. right-handed LQs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the EMC Effect of the Helium-3 Nucleus at Jefferson Lab

The MARATHON (MeAsurement of the Fn 2 /Fp 2 , d/u RAtios and A=3 EMC Effect in Deep Inelastic Scattering Off the Tritium and Helium MirrOr Nuclei) experiment ran in the Hall A Facility of the Thomas Jefferson National Accelerator Facility (JLab). The experiment used a 10.59 GeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) of JLab to measure the ratio of the F2 structure functions of Helium-3 and Deuterium. Data were taken in the kinematic range of 0.195 lte x lte 0.825, 2.5 (GeV/c)2 lte Q2 lte 13 (GeV/c)2, and 3.5 (GeV/c2)^2 lte W^2 lte 13 (GeV/c2)^2. This is the first measurement of the 3He EMC effect that is purely in the Deep Inelastic Scattering region. The results of this experiment constitute an important, complimentary addition, to the limited data presently available for the EMC effect of light nuclei. The MARATHON results are compared to the world data for light, medium, and heavy nuclei. This measurement is considered an essential component to uncovering the nature of the EMC effect.

Hague, Tyler↗

Measurement of the Deeply Virtual Compton Scattering Cross Section from the Proton at 10.6 GeV using the CLAS12 Detector

Deeply Virtual Compton Scattering (DVCS) is an exclusive process that produces a real photon when a lepton scatters from a quark inside a nucleon or a nucleus. Measurement of the DVCS cross section enables the study of the Generalized Parton Distributions (GPD), which plays a central role in understanding the QCD dynamics inside a hadron. Thus, the quark and gluon origin of the nucleon spin and mass can be probed and three-dimensional images of the target nucleon or nucleus can be realized. This thesis presents a cross section analysis of DVCS from the proton in the presence of its background, Bethe-Heitler (BH) process. The CEBAF Large Acceptance Spectrometer for operation at 12 GeV beam energy (CLAS12) collaboration has taken electron-proton scattering data in fall 2018 using a liquid hydrogen target and the 10.6 GeV polarized electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF). The CLAS12 detector is a nearly hermetic fixed-target detector, located in Hall B, Jefferson Lab at Newport News, Virginia. The experimentally determined BH-DVCS cross section is in good agreement with a phenomenological-model based theoretical prediction. The kinematic dependence of the cross section is reported over a wide range. The short-term plan to utilize the results presented here for a thorough tomography study and the long-term plan for GPD studies at future facilities such as the Electron-Ion Collider (EIC) are discussed.

Lee, Sangbaek↗

DESIGNING THE SPREADERS AND SPLITTERS FOR THE FFA@CEBAF ENERGY UPGRADE

The FFA@CEBAF energy upgrade study aims to approximately double the final energy of the electron beam at the Continuous Electron Beam Accelerator Facility (CEBAF). It will do this by replacing the highest-energy recirculating arcs with fixed-field alternating gradient (FFA) arcs, allowing for several more passes to circulate through the machine. This upgrade necessitates the re-design of the vertical spreader sections, which separates each pass into different recirculation arcs. Additionally, the FFA arcs will need horizontal splitter lines to correct for time of flight and R56. This work will present the current state of the spreader re-design and splitter design.

Benesch, J.↗

Status of the Ce+BAF project

Jefferson Lab is proposing to add positron beams to the 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF). A team of accelerator and nuclear scientists was formed in 2018 to develop the physics case as well as a concept for the generation, production and delivery of Continuous (CW) polarized positron beams to the experimental halls, up to the full 12 GeV. A layout of the proposed concept will be shown. We will report on the ongoing efforts in the positron generation and capture, target design, beam transport and expected properties of the e+ beam on the experimental targets at 12GeV. This project is supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177

Roblin, Yves↗

Status of the Ce+BAF project

Jefferson Lab is proposing to add positron beams to the 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF). A team of accelerator and nuclear scientists was formed in 2018 to develop the physics case as well as a concept for the generation, production and delivery of Continuous (CW) polarized positron beams to the experimental halls, up to the full 12 GeV. A layout of the proposed concept will be shown. We will report on the ongoing efforts in the positron generation and capture, target design, beam transport and expected properties of the e+ beam on the experimental targets at 12GeV. This project is supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177

Roblin, Yves↗

Transport of 12 GeV positron beams at Ce+BAF

Jefferson Lab (JLab) is developing a concept to upgrade the Continuous Electron Beam Accelerator Facility (CEBAF) to additionally deliver spin-polarized continuous-wave positron beams for its nuclear physics program users (Ce+BAF 12 GeV). The concept involves repurposing the Low Energy Recirculator Facility (LERF) at JLab as a dual injector, first producing 100-300 MeV spin-polarized electron beams which are subsequently used for the generation and formation of 123 MeV continuous-wave positron beams. The positron beams are transported to CEBAF and injected for acceleration up to 12 GeV, tailored to the requirements of its four experimental halls. Given the higher emittance of the secondary positron beams, the CEBAF optics are optimized for low dispersion and low beta functions to enhance transmission within the Ce+BAF acceptance limits and with an R56 to manage the positron beams bunch length and energy spread. Potential bottlenecks are being investigated through both optical modeling and measurements using an electron beam, as well as degraded electron beams, to map the 6d acceptance of CEBAF as it is today. This presentation shares preliminary results from multi-particle tracking simulations of the positron beam up to 12 GeV, including spatial, momentum, and spin characteristics, and explores the feasibility of delivering beams simultaneously to multiple experimental halls via extraction optics.

Accelerator Physics↗

Multiple Synchrotron Light Monitors for Transverse Matching and Monitoring at CEBAF

Beam setup at the Continuous Electron Beam Accelerator Facility (CEBAF) involves threading beam through the machine and monitoring global transfer functions to identify and address cumulative lattice errors. Transverse beam emittance may grow by as much as two orders of magnitude, mediated by synchrotron radiation. Re-matching the enlarged beam phase space into successive re-circulation arcs minimizes this emittance growth but requires knowledge of the actual beam distribution. This is now accomplished through quadrupole scans using wire profile monitors, the most time-consuming activity in our setup process. We propose to use Synchrotron Light Monitors (SLMs) to image the beam at homologous points in the four super-period recirculation arc lattices. Benefits include real-time monitoring of beam parameters and reduced elapsed time for initial setup.These SLMs will be installed in Arc 7 of the CEBAF machine, where Synchrotron Radiation contributes moderately to emittance growth. One of four required SLMs will be installed and commissioned this year, with the rest being installed next year.

Freeman, B.↗

First degraded beams in the CEBAF injector

The electron beam degrader in the Continuous Electron Beam Accelerator Facility (CEBAF) injector at Jefferson Lab serves to generate electron beams with transverse emittance over 10x the nominal values, with the ultimate goal of using degraded electron beams to measure machine acceptance. Electron beams are degraded through multiple scattering in thin carbon foils, and maximum transverse emittance is defined through two collimating apertures. The degrader device was installed in late 2024, with commissioning and first beams on degrader targets during the 2025 physics run. We report on first operation of the degrader device. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177.

Sy, A. [Thomas Jefferson National Accelerator Faci↗

Secondary Beams at Jefferson Laboratory

This thesis explores the possibility of producing secondary beams at the Thomas Jefferson National Accelerator Facility (TJNAF). Their possible applications in future experiments are studied using advanced Monte Carlo simulations with state-of-the-art software. In Jefferson Lab’s Hall-A, the interaction of the high-current O(100) µA, medium-energy O(11) GeV electron beam produced by the Continuous Electron Beams Accelerator Facility (CEBAF) with the Beam-Dump (BD) generates a substantial shower of standard model particles. This interaction creates a high-intensity secondary muon and neutrino beam and hypothetical Light Dark Matter (LDM) particles. Additionally, with the proposed Compact Photon Source (CPS), Hall-D could offer the possibility of producing an intense muon beam alongside a photon beam.

Fulci, Antonino↗

SRF cavity instability detection with machine learning at CEBAF

During the operation of the Continuous Electron Beam Accelerator Facility (CEBAF), one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detectfast transient instabilities during these trip events. These challenges make the identification of an unstable cavity out of the hundreds installed at CEBAF a difficult and time-consuming task. To tackle these issues, a fast data acquisition system (DAQ) for the legacy SRF cavities has been developed, which records the sample at 5 kHz. An unsupervised learning framework has been developed to identify anomalous SRF cavity behavior. We will discuss the present status of the DAQ system and our framework, along with recent successes in detecting anomalous cavity behavior. Overall, our method offers a practical solution for identifying unstable SRF cavities, contributing to increased beam availability and machine reliability.

Accelerator Physics↗

CONCEPT OF A POLARIZED POSITRON SOURCE FOR CEBAF

Positron beams would provide new and meaningful probes for the experimental program at the Thomas Jefferson National Accelerator Facility (JLab), including but not limited to future hadronic physics and dark matter experiments. Critical requirements involve generating positron beams with a high degree of spin polarization, sufficient intensity and a continuous-wave (CW) bunch train compatible with acceleration to 12 GeV at the Continuous Electron Beam Accelerator Facility (CEBAF). To address these requirements, a polarized positron injector based upon the bremsstrahlung of an intense CW spin polarized electron beam is considered*. First a polarized electron beam line provides >1 mA of polarized electrons at ~120 MeV to a high-power target for positron production. Next, a second beam line collects, shapes and aligns the spin of positrons for users. Finally, the positron beam is matched into the CEBAF acceptance for acceleration and transport to the end stations with energies up to 12 GeV. An optimized layout to provide positrons beams with intensity >100 nA (polarized) or intensity >3 µA (unpolarized) will be discussed in this poster.

Habet, S. H.↗

Photoproduction of the Λ(1520) hyperon with a 9 GeV photon beam at GlueX

The GlueX experiment is located at the Thomas Jefferson National Accelerator Facility (JLab) in Newport News, VA, USA. It features a hermetic 4π detector with excellent tracking and calorimetry capabilities. Its 9 GeV linearly polarized photon beam is produced from the 12 GeV electron beam, delivered by JLab’s Continuous Electron Beam Accelerator Facility (CEBAF), via bremsstrahlung on a thin diamond and is incident on a LH2 target. GlueX recently finished its first data taking period and published first results. The main goal of GlueX is to measure gluonic excitations of mesons. These so-called hybrid or exotic mesons are predicted by Quantum Chromodynamics (QCD) but haven’t been experimentally confirmed yet. They can have quantum numbers not accessible by ordinary quark-antiquark pairs which helps in identifying them using partial wave analysis techniques. The search for exotic mesons requires a very good understanding of photoproduction processes in a wide range of final states, one of them being pK + K - which contains many meson and baryon reactions. The Λ(1520) is a prominent hyperon resonance in this final state and is the subject of this presentation. This talk will give an introduction to the GlueX experiment and show preliminary results for the photoproduction of the Λ(1520) hyperon. The measurement of important observables like the photon beam asymmetry and spin-density matrix elements will be discussed and an outlook to possible measurements of further hyperon states in the pK + K - final state will be given.

Pauli, Peter↗

Measuring the Beam-Spin Asymmetry of Hard Exclusive ¿0 Production off the Neutron with CLAS12

Over the course of the last couple of decades, Generalised Parton Distributions (GPDs) have become a compelling area of focus in both theoretical and experimental research in the ?eld of hadronic structure. GPDs can be indirectly accessed via observables in hard exclusive reactions such as Deeply Virtual Compton Scattering (DVCS) and Deeply Virtual Meson Production (DVMP). In these reactions, an incident lepton scatters o? an individual quark within the target nucleon via the exchange of a virtual photon, and a real photon (DVCS) or a meson (DVMP) are emitted as a result. This thesis presents an analysis of Deeply Virtual ?0 Meson Production o? the neutron in the deuteron (nDV?0P). The data were taken with the CLAS12 detector, which is housed in the experimental Hall B at the Je?erson National Laboratory (JLab) in Virginia, USA. A longitudinally polarised electron beam delivered by JLab?s Continuous Electron Beam accelerator Facility (CEBAF), at an energy of 10.2 and 10.6 GeV, was incident on a liquid deuterium target housed within the CLAS12 detector assembly. The nDV?0P channel is sensitive to the lesser-studied chiral-odd transversity GPDs. GPDs are accessed indirectly via observables related to the cross-sections of hard exclusive processes. One such example is the beam-spin asymmetry (?LU) as a function of Trento-?, the angle between the leptonic plane and the hadronic plane which are de?ned with the beam and scattered electron, and with the recoiling neutron and reconstructed ?0, respectively. Despite the limited statistics, the observable ?LU was successfully extracted for eight kinematic bins (four in Mandelstam ?, and two in ??). This is a ?rst measurement for nDV?0P in the phase-space which is now available with CLAS12 in the 12 GeV era of JLab.

Naidoo, Paul↗

Concept of a polarized positron source for CEBAF

This thesis focuses on the development of polarized and unpolarized positron beams for the future experimental pro- gram of hadronic physics at the Thomas Jefferson National Accelerator Facility (JLab). The primary challenge is to produce high-duty-cycle and high-intensity polarized positron beams. The JLab positron source, which is based on the PEPPo (Polarized Electrons for Polarized Positrons) technique, aims to use a high intensity (1 mA) and highly polarized (90%) continuous electron beam of moderate energy (120 MeV) to produce either a low intensity (>50 nA), highly polarized (60%) positron beam or a high intensity (>1 ?A), unpolarized positron beam. The optimization of the layout and performance of the positron source is examined in this thesis. The source is designed with a specialized second injector to generate, transport, accelerate, and shape positron beams. It is compatible with acceleration at the Continuous Electron Beam Accelerator Facility (CEBAF), and the investigation results are presented in this document.

Habet, Sami↗

Redesigning the Jefferson Lab Hall A beam line for high precision parity experiments

The Continuous Electron Beam Accelerator Facility (CEBAF) was built with a thermionic electron source and the three original experimental hall lines reflected this. A few years after beam delivery began a parity violation experiment was approved and two polarimeters were installed in the Hall A beam line. The beam raster system was placed after the new Compton polarimeter, before one accelerator quadrupole and four quadrupoles in the new Moller polarimeter. It was very difficult to meet experimental requirements on envelope functions and raster shape with this arrangement so a sixth quadrupole was installed downstream of the Moller polarimeter to provide an additional degree of freedome. All of the parity experiments in Hall A have been run with this still-unsatisfactory configuration. The MOLLER experiment is predicated on achieving a 2% error on a 32 ppb asymmetry. Beam line changes are required to meet the systematic error budget. This work documents the existing beam line, an interim change which can be accomplished during a annual maintenance down, and the final configuration for MOLLER and subsequent experiments.

47 OTHER INSTRUMENTATION↗

Beam study on low dispersion CEBAF arcs

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab employs recirculating linac SRF technology to generate a high polarization 12 GeV electron beam for nuclear physics users. New opportunities to study multipass energy recovery have also emerged with the proposal of a 5-pass energy recovery demonstration, ER@CEBAF. New beam optics with minimized beta functions have been developed and tested to avoid collective beam instabilities for multi-pass beams and meet the beam requirements of the nuclear physics community. To enable energy recovery for a common arc beam transport of five passes, achromatic and isochronous arc optics conditions were satisfied by re-designing the transverse optics of CEBAF. This paper focuses on beam studies conducted to study the newly-designed, low-dispersion, lowest energy arcs for CEBAF operations and ER@CEBAF.

Neththikumara, I.↗