Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Detection of random noise and anatomy of continuous seismic waveforms in dense array data near Anza California

We develop a methodology to separate continuous seismic waveforms into random noise (RN), not random noise (NRN) produced by earthquakes, wind, traffic and other sources of ground motions, and an undetermined mixture of signals. The analysis is applied to continuous records from a dense seismic array on the San Jacinto fault zone. To detect RN signals, we cut hourly waveforms into non-overlapping 1 s time windows and apply cross-correlations to separate RN candidates from outliers. The cross-correlation coefficients between different RN candidates fall into a tight range (i.e. 0.09–0.35), while cross-correlation coefficients of RN candidates with NRN signals (e.g. seismic or air-traffic events) are lower. The amplitude spectra of RN candidates have a well-defined level, while the amplitude spectra of other signals deviate from that level. Using these properties, we examine the amplitude spectra of moving time windows and cross-correlation coefficients with RN templates in each hour. The hourly RN is quasi-stationary and the results cluster tightly in the parameter space of cross-correlation coefficients and L2 norm deviations from the mean spectra of RN candidates. Time windows with parameters in this tight cluster are identified as RN, windows that deviate significantly from the RN cluster are identified as NRN and windows with values in between are identified as mixed signals. Several iterations on each hourly data are used to update and stabilize the selection of RN templates and mean noise spectra. For the days examined, the relative fractions of RN, NRN and mixed signals in local day (night) times are about 26 (42 percent), 40 (33 percent) and 34 percent (25 percent), respectively.

Geochemistry & Geophysics↗

Investigating the ecological fallacy through sampling distributions constructed from finite populations

Correlation coefficients and linear regression values computed from group averages can differ from correlation coefficients and linear regression values computed using individual scores. This observation known as the ecological fallacy often assumes that all the individual scores are available from a population. In many situations, one must use a sample from the larger population. In such cases, the computed correlation coefficient and linear regression values will depend on the sample that is chosen and the underlying sampling distribution. The sampling distribution of correlation coefficients and linear regression values for group averages will be identical to the sampling distribution for individuals for normally distributed variables for random samples drawn from infinitely large continuous distributions. However, data that is acquired in practice is often acquired when sampling without replacement from a finite population. Our objective is to demonstrate through Monte Carlo simulations that the sampling distributions for correlation and linear regression will also be similar for individuals and group averages when sampling without replacement from normally distributed variables. These simulations suggest that when a random sample from a population is selected, the correlation coefficients and linear regression values computed from individual scores will not be more accurate in estimating the entire population values compared to samples when group averages are used as long as the sample size is the same.

97 MATHEMATICS AND COMPUTING↗

The pNab experiment and the quest for ever better neutron beam polarization

The Nab and pNAB collaborations are conducting a program of studies of free neutron beta decay, with the primary goal of testing the unitarity of the Cabbibo-Kobayashi-Maskawa matrix that describes quark mixing due to the weak interaction. For this purpose, a large, novel electromagnetic spectrometer, the Nab spectrometer, has been designed, built, and placed in use to determine the correlation coefficients in unpolarized neutron beta decay: "a", the neutrino-electron correlation coefficient; and "b", the Fierz term. The subject of this paper is pNAB, the second phase of the program, that will deploy the same spectrometer with a polarized neutron beam to determine "A", the beta asymmetry; and "B", the neutrino asymmetry coefficients. A focus of this paper will be on the strategies to provide a high and precisely known neutron beam polarization.

Baessler, Stefan↗

Advanced Fuel Cycle Cost Basis Report: Supporting Documents 3 Cost Correlations

This chapter provides an overview of the drivers for developing correlation coefficients, status on efforts to develop partial correlation coefficients, and recommended next steps. Mathematical methods for developing and using correlation coefficients were previously documented by the FCO EWG in Chapters 6 and 7 of [Ganda 2014].

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computerized scheme for evaluating mammographic phantom images

Purpose: The authors developed a computer algorithm to automatically evaluate images of the American College of Radiology (ACR) mammography accreditation phantom. Methods: The developed algorithm consist of the edge detection of wax insert, nonuniformity correction of background, and correction for magnification and also calculate the cross-correlation coefficient by image matching technique. The algorithm additionally evaluates target shape for fibers, target contrast for speck groups, and target circularity for masses. To obtain an ideal template image without noise and spatial resolution loss, the wax insert containing the embedded test pattern was extracted from the phantom and radiographed. Two template images and ten test phantom images were prepared for this study. The results of evaluation using the algorithm outputs were compared with the averaged results of observer studies by six skilled observers. Results: In comparing the results from the algorithm outputs with the results of observers, the authors found that the computer outputs were well correlated with the evaluations by observers, and they indicate the quality of the phantom image. The correlation coefficients between results of observer studies and two outputs of computer algorithm, i.e., the cross-correlation coefficient by template matching and indices of target shape for fibers, were 0.89 (95% confidence interval, 0.82-0.93; hereinafter the same) and 0.85 (0.76-0.91). The correlation coefficients between observer's results and two outputs: the cross-correlation coefficient and indices of target contrast for speck groups, were 0.83 (0.79-0.86) and 0.85 (0.81-0.88) and between observer's results and two outputs: the cross-correlation coefficient and indices of target circularity for masses, were 0.90 (0.84-0.94) and 0.87 (0.77-0.92). Conclusions: Image evaluation using the ACR phantom is indispensable in quality control of a mammography system. The proposed algorithm is useful for quality control and image evaluation of mammography units.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Noise correlation in CBCT projection data and its application for noise reduction in low-dose CBCT

Purpose: To study the noise correlation properties of cone-beam CT (CBCT) projection data and to incorporate the noise correlation information to a statistics-based projection restoration algorithm for noise reduction in low-dose CBCT. Methods: In this study, the authors systematically investigated the noise correlation properties among detector bins of CBCT projection data by analyzing repeated projection measurements. The measurements were performed on a TrueBeam onboard CBCT imaging system with a 4030CB flat panel detector. An anthropomorphic male pelvis phantom was used to acquire 500 repeated projection data at six different dose levels from 0.1 to 1.6 mAs per projection at three fixed angles. To minimize the influence of the lag effect, lag correction was performed on the consecutively acquired projection data. The noise correlation coefficient between detector bin pairs was calculated from the corrected projection data. The noise correlation among CBCT projection data was then incorporated into the covariance matrix of the penalized weighted least-squares (PWLS) criterion for noise reduction of low-dose CBCT. Results: The analyses of the repeated measurements show that noise correlation coefficients are nonzero between the nearest neighboring bins of CBCT projection data. The average noise correlation coefficients for the first- and second-order neighbors are 0.20 and 0.06, respectively. The noise correlation coefficients are independent of the dose level. Reconstruction of the pelvis phantom shows that the PWLS criterion with consideration of noise correlation (PWLS-Cor) results in a lower noise level as compared to the PWLS criterion without considering the noise correlation (PWLS-Dia) at the matched resolution. At the 2.0 mm resolution level in the axial-plane noise resolution tradeoff analysis, the noise level of the PWLS-Cor reconstruction is 6.3% lower than that of the PWLS-Dia reconstruction. Conclusions: Noise is correlated among nearest neighboring detector bins of CBCT projection data. An accurate noise model of CBCT projection data can improve the performance of the statistics-based projection restoration algorithm for low-dose CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-A-18C-03: Noise Correlation in CBCT Projection Data and Its Application for Noise Reduction in Low-Dose CBCT

Purpose: To study the noise correlation properties of cone-beam CT (CBCT) projection data and to incorporate the noise correlation information to a statistics-based projection restoration algorithm for noise reduction in low-dose CBCT. Methods: In this study, we systematically investigated the noise correlation properties among detector bins of CBCT projection data by analyzing repeated projection measurements. The measurements were performed on a TrueBeam on-board CBCT imaging system with a 4030CB flat panel detector. An anthropomorphic male pelvis phantom was used to acquire 500 repeated projection data at six different dose levels from 0.1 mAs to 1.6 mAs per projection at three fixed angles. To minimize the influence of the lag effect, lag correction was performed on the consecutively acquired projection data. The noise correlation coefficient between detector bin pairs was calculated from the corrected projection data. The noise correlation among CBCT projection data was then incorporated into the covariance matrix of the penalized weighted least-squares (PWLS) criterion for noise reduction of low-dose CBCT. Results: The analyses of the repeated measurements show that noise correlation coefficients are non-zero between the nearest neighboring bins of CBCT projection data. The average noise correlation coefficients for the first- and second- order neighbors are about 0.20 and 0.06, respectively. The noise correlation coefficients are independent of the dose level. Reconstruction of the pelvis phantom shows that the PWLS criterion with consideration of noise correlation (PWLS-Cor) results in a lower noise level as compared to the PWLS criterion without considering the noise correlation (PWLS-Dia) at the matched resolution. Conclusion: Noise is correlated among nearest neighboring detector bins of CBCT projection data. An accurate noise model of CBCT projection data can improve the performance of the statistics-based projection restoration algorithm for low-dose CBCT.

60 APPLIED LIFE SCIENCES↗

Spatiotemporal Stability of Cu-ATSM and FLT Positron Emission Tomography Distributions During Radiation Therapy

Purpose: In dose painting, in which functional imaging is used to define biological targets for radiation therapy dose escalation, changes in spatial distributions of biological properties during treatment can compromise the quality of therapy. The goal of this study was to assess the spatiotemporal stability of 2 potential dose painting targets—hypoxia and proliferation—in canine tumors during radiation therapy. Methods and Materials: Twenty-two canine patients with sinonasal tumors (14 carcinoma and 8 sarcoma) were imaged before hypofractionated radiation therapy with copper(II)-diacetyl-bis(N4-methylthiosemicarbazone) (Cu-ATSM) positron emission tomography/computed tomography (PET/CT) for hypoxia and 3′-deoxy-3′-{sup 18}F-fluorothymidine (FLT) PET/CT for proliferation. The FLT scans were repeated after 2 fractions and the Cu-ATSM scans after 3 fractions. Midtreatment PET/CT images were deformably registered to pretreatment PET/CT images. Voxel-based Spearman correlation coefficients quantified the spatial stability of Cu-ATSM and FLT uptake distributions between pretreatment and midtreatment scans. Paired t tests determined significant differences between the patients' respective Cu-ATSM and FLT correlations coefficients. Standardized uptake value measures were also compared between pretreatment and midtreatment scans by use of paired t tests. Results: Spatial distributions of Cu-ATSM and FLT uptake were stable through midtreatment for both sarcomas and carcinomas: the population mean ± standard deviation in Spearman correlation coefficient was 0.88 ± 0.07 for Cu-ATSM and 0.79 ± 0.13 for FLT. The patients' Cu-ATSM correlation coefficients were significantly higher than their respective FLT correlation coefficients (P=.001). Changes in Cu-ATSM SUV measures from pretreatment to midtreatment were histology dependent: carcinomas experienced significant decreases in Cu-ATSM uptake (P<.05), whereas sarcomas did not (P>.20). Both histologies experienced significant decreases in FLT uptake (P<.05). Conclusions: Spatial distributions of Cu-ATSM were very stable after a few fractions of radiation therapy. FLT spatial distributions were generally stable early in therapy, although they were significantly less stable than Cu-ATSM distributions. Canine tumors had significantly lower proliferative activity at midtreatment than at pretreatment, and they experienced histology-dependent changes in Cu-ATSM uptake.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study Of The Solar Wind Parameters During The 23rd Solar Cycle

In this paper we study the solar wind parameters during the 23rd solar cycle and the possible correlation between them. Those parameters' data, which are Alfven Mach number, plasma beta, flow speed, proton density and temperature, dynamic pressure, average magnetic field, Bx and By, has been taken from OMNI 2. The first part of this project is about analysis and correlation of the data, using Pearson's product moment correlation coefficient and Spearman Rank Correlation Coefficient, during the 11 years of the 23rd cycle. The second part is about Wavelet analysis on those parameters during the 21st, 22nd, 23rd solar cycles in comparison with them. We found that each parameter has different behavior in every cycle and certain periodicities that appear constantly.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-662: Feasibility Study of Fe3O4/TaOx Nano Particles as a Radiosensitizer for Radiation Therapy

Purpose: To investigate the feasibility of using multifunctional Fe{sub 3}O{sub 4}/TaOx(core / shell) nano particles developed for CT and MRI contrast agent as dose enhancing radiosensitizers. Methods: Firstly, to verify the imaging detectability of Fe{sub 3}O{sub 4}/TaOx nano particles, in-vivo tests were conducted. Approximately 600 mg/kg of 19 nm diameter Fe{sub 3}O{sub 4}/TaOx nano particles dispersed in phosphate buffered saline(PBS) were injected to ten nude Balb/c mice through the tail vein. Difference between pre- and post-injection images was analyzed by computing the pixel histogram and correlation coefficient factor using MATLAB in the user defined ROI. Secondly, to quantify the potential therapeutic enhancement with nano materials, DER (Dose Enhancement Ratio) and number of SER (Secondary Electron Ratio) were computed using TOPAS(ver.2.0 P-03) MC simulation. Results: In CT, MRI imaging, the aorta, the blood vessel, and the liver were clearly visualized after intravenous injection of Fe{sub 3}O{sub 4}/TaOx nano particles. There was large different between pre and post-injection images of Histogram data and Coefficients of correlation factor in CT and MR are 0.006, 0.060, respectively. When 70 MeV protons were irradiated for a Gold, Tantalum, TaOx, Fe{sub 3}O{sub 4}/TaOx, Fe{sub 3}O{sub 4} nano particle, DER was 2.59, 2.41, 1.68, 1.54 and 1.36 respectively. Similarly, SER increment was 2.31, 2.15, 1.56, 1.46, and 1.27 for Gold, Tantalum, TaOx, Fe{sub 3}O{sub 4}/TaOx, Fe{sub 3}O{sub 4} nano particle, respectively. Conclusion: Fe{sub 3}O{sub 4}/TaOx nano particles have potential as a multifunctional agent which enhances the accuracy in cancer detection through visualization of developed tumor lesion and increases the therapeutic effect in proton therapy. The dose enhancement with Fe{sub 3}O{sub 4}/TaOx was estimated as half of the Gold. However, tumor targeting such as combined with magnetic field may overcome the low DER. This research was supported by the NRF funded by the Ministry of Science, ICT & Future Planning (2012M3A9B6055201 and 2012R1A1A2042414), Samsung Medical Center grant[GFO1130081].

60 APPLIED LIFE SCIENCES↗

PanFP: Pangenome-based functional profiles for microbial communities

For decades there has been increasing interest in understanding the relationships between microbial communities and ecosystem functions. Current DNA sequencing technologies allows for the exploration of microbial communities in two principle ways: targeted rRNA gene surveys and shotgun metagenomics. For large study designs, it is often still prohibitively expensive to sequence metagenomes at both the breadth and depth necessary to statistically capture the true functional diversity of a community. Although rRNA gene surveys provide no direct evidence of function, they do provide a reasonable estimation of microbial diversity, while being a very cost effective way to screen samples of interest for later shotgun metagenomic analyses. However, there is a great deal of 16S rRNA gene survey data currently available from diverse environments, and thus a need for tools to infer functional composition of environmental samples based on 16S rRNA gene survey data. As a result, we present a computational method called pangenome based functional profiles (PanFP), which infers functional profiles of microbial communities from 16S rRNA gene survey data for Bacteria and Archaea. PanFP is based on pangenome reconstruction of a 16S rRNA gene operational taxonomic unit (OTU) from known genes and genomes pooled from the OTU s taxonomic lineage. From this lineage, we derive an OTU functional profile by weighting a pangenome s functional profile with the OTUs abundance observed in a given sample. We validated our method by comparing PanFP to the functional profiles obtained from the direct shotgun metagenomic measurement of 65 diverse communities via Spearman correlation coefficients. These correlations improved with increasing sequencing depth, within the range of 0.8 0.9 for the most deeply sequenced Human Microbiome Project mock community samples. PanFP is very similar in performance to another recently released tool, PICRUSt, for almost all of survey data analysed here. But, our method is unique in that any OTU building method can be used, as opposed to being limited to closed reference OTU picking strategies against specific reference sequence databases. In conclusion, we developed an automated computational method, which derives an inferred functional profile based on the 16S rRNA gene surveys of microbial communities. The inferred functional profile provides a cost effective way to study complex ecosystems through predicted comparative functional metagenomes and metadata analysis. All PanFP source code and additional documentation are freely available online at GitHub.

16S rRNA survey↗

PET CT Thresholds for Radiotherapy Target Definition in Non-Small-Cell Lung Cancer: How Close are we to the Pathologic Findings?

Purpose: Optimal target delineation threshold values for positron emission tomography (PET) and computed tomography (CT) radiotherapy planning is controversial. In this present study, different PET CT threshold values were used for target delineation and then compared pathologically. Methods and Materials: A total of 31 non-small-cell lung cancer patients underwent PET CT before surgery. The maximal diameter (MD) of the pathologic primary tumor was obtained. The CT-based gross tumor volumes (GTV{sub CT}) were delineated for CT window-level thresholds at 1,600 and -300 Hounsfield units (HU) (GTV{sub CT1}); 1,600 and -400 (GTV{sub CT2}); 1,600 and -450 HU (GTV{sub CT3}); 1,600 and -600 HU (GTV{sub CT4}); 1,200 and -700 HU (GTV{sub CT5}); 900 and -450 HU (GTV{sub CT6}); and 700 and -450 HU (GTV{sub CT7}). The PET-based GTVs (GTV{sub PET}) were autocontoured at 20% (GTV{sub 20}), 30% (GTV{sub 30}), 40% (GTV{sub 40}), 45% (GTV{sub 45}), 50% (GTV{sub 50}), and 55% (GTV{sub 55}) of the maximal intensity level. The MD of each image-based GTV in three-dimensional orientation was determined. The MD of the GTV{sub PET} and GTV{sub CT} were compared with the pathologically determined MD. Results: The median MD of the GTV{sub CT} changed from 2.89 (GTV{sub CT2}) to 4.46 (GTV{sub CT7}) as the CT thresholds were varied. The correlation coefficient of the GTV{sub CT} compared with the pathologically determined MD ranged from 0.76 to 0.87. The correlation coefficient of the GTV{sub CT1} was the best (r = 0.87). The median MD of GTV{sub PET} changed from 5.72cm to 2.67cm as the PET thresholds increased. The correlation coefficient of the GTV{sub PET} compared with the pathologic finding ranged from 0.51 to 0.77. The correlation coefficient of GTV{sub 50} was the best (r = 0.77). Conclusion: Compared with the MD of GTV{sub PET}, the MD of GTV{sub CT} had better correlation with the pathologic MD. The GTV{sub CT1} and GTV{sub 50} had the best correlation with the pathologic results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Discrete game-theoretic analysis of defense in correlated cyber-physical systems

A cyber-physical system (CPS) is composed of a discrete number of cyber and physical components and subject to internal failures and external disruptions. The functionality of CPS therefore is determined not only by cyber and physical components but the adversary’s attacker strategy. We characterize the effect of cyber-physical interdependency on the CPS survival probability using a product-form function with cyber and physical exponential correlation coefficients. We model simultaneous and sequential discrete games between the provider and attacker on a CPS infrastructure to analyze its survivability and reinforcement strategy at Nash equilibrium. Our results show that the cyber and physical correlation coefficients can significantly affect CPS survival probability. In general, the provider’s cyber- (or physical-) reinforcement level increases as the cyber- (or physical-) attack level increases. In each of cyber and physical domains, the reinforcement level first increases then decreases in its own correlation coefficient, probability of successful component attacks, and maximum level of available resources, but decreases in the correlation coefficient of the other domain. We apply this game-theoretic analysis to a cloud computing infrastructure, and show that its residual capacity is relatively high when the attacker has no information about the distribution of servers. Finally, a high level of survival probability does not necessarily lead to high utility.

97 MATHEMATICS AND COMPUTING↗

INTERPRETING THE DISTANCE CORRELATION RESULTS FOR THE COMBO-17 SURVEY

The accurate classification of galaxies in large-sample astrophysical databases of galaxy clusters depends sensitively on the ability to distinguish between morphological types, especially at higher redshifts. This capability can be enhanced through a new statistical measure of association and correlation, called the distance correlation coefficient, which has more statistical power to detect associations than does the classical Pearson measure of linear relationships between two variables. The distance correlation measure offers a more precise alternative to the classical measure since it is capable of detecting nonlinear relationships that may appear in astrophysical applications. We showed recently that the comparison between the distance and Pearson correlation coefficients can be used effectively to isolate potential outliers in various galaxy data sets, and this comparison has the ability to confirm the level of accuracy associated with the data. In this work, we elucidate the advantages of distance correlation when applied to large databases. We illustrate how the distance correlation measure can be used effectively as a tool to confirm nonlinear relationships between various variables in the COMBO-17 database, including the lengths of the major and minor axes, and the alternative redshift distribution. For these outlier pairs, the distance correlation coefficient is routinely higher than the Pearson coefficient since it is easier to detect nonlinear relationships with distance correlation. The V-shaped scatter plots of Pearson versus distance correlation coefficients also reveal the patterns with increasing redshift and the contributions of different galaxy types within each redshift range.

79 ASTRONOMY AND ASTROPHYSICS↗

A correlation based fault detection method for short circuits in battery packs

Here this paper presents a fault detection method for short circuits based on the correlation coefficient of voltage curves. The proposed method utilizes the direct voltage measurements from the battery cells, and does not require any additional hardware or effort in modeling during fault detection. Moreover, the inherent mathematical properties of the correlation coefficient ensure the robustness of this method as the battery pack ages or is imbalanced in real applications. In order to apply this method online, the recursive moving window correlation coefficient calculation is adopted to maintain the detection sensitivity to faults during operation. An additive square wave is designed to prevent false positive detections when the batteries are at rest. The fault isolation can be achieved by identifying the overlapped cell in the correlation coefficients with fault flags. Simulation and experimental results validated the feasibility and demonstrated the advantages of this method.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prospective Study Validating Inter- and Intraobserver Variability of Tissue Compliance Meter in Breast Tissue of Healthy Volunteers: Potential Implications for Patients With Radiation-Induced Fibrosis of the Breast

Purpose: Accurate detection of radiation-induced fibrosis (RIF) is crucial in management of breast cancer survivors. Tissue compliance meter (TCM) has been validated in musculature. We validate TCM in healthy breast tissue with respect to interobserver and intraobserver variability before applying it in RIF. Methods and Materials: Three medical professionals obtained three consecutive TCM measurements in each of the four quadrants of the right and left breasts of 40 women with no breast disease or surgical intervention. The intraclass correlation coefficient (ICC) assessed interobserver variability. The paired t test and Pearson correlation coefficient (r) were used to assess intraobserver variability within each rater. Results: The median age was 45 years (range, 24-68 years). The median bra size was 35C (range, 32A-40DD). Of the participants, 27 were white (67%), 4 black (10%), 5 Asian (13%), and 4 Hispanic (10%). ICCs indicated excellent interrater reliability (low interobserver variability) among the three raters, by breast and quadrant (all ICC {>=}0.99). The paired t test and Pearson correlation coefficient both indicated low intraobserver variability within each rater (right vs. left breast), stratified by quadrant (all r{>=} 0.94, p < 0.0001). Conclusions: The interobserver and intraobserver variability is small using TCM in healthy mammary tissue. We are now embarking on a prospective study using TCM in women with breast cancer at risk of developing RIF that may guide early detection, timely therapeutic intervention, and assessment of success of therapy for RIF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Weak data do not make a free lunch, only a cheap meal

Refinement and analysis of four structures with various data resolution cutoffs suggests that at present there are no reliable criteria for judging the diffraction data resolution limit and the condition I/σ(I) = 2.0 is reasonable. However, extending the limit by about 0.2 Å beyond the resolution defined by this threshold does not deteriorate the quality of refined structures and in some cases may be beneficial. Four data sets were processed at resolutions significantly exceeding the criteria traditionally used for estimating the diffraction data resolution limit. The analysis of these data and the corresponding model-quality indicators suggests that the criteria of resolution limits widely adopted in the past may be somewhat conservative. Various parameters, such as R{sub merge} and I/σ(I), optical resolution and the correlation coefficients CC{sub 1/2} and CC*, can be used for judging the internal data quality, whereas the reliability factors R and R{sub free} as well as the maximum-likelihood target values and real-space map correlation coefficients can be used to estimate the agreement between the data and the refined model. However, none of these criteria provide a reliable estimate of the data resolution cutoff limit. The analysis suggests that extension of the maximum resolution by about 0.2 Å beyond the currently adopted limit where the I/σ(I) value drops to 2.0 does not degrade the quality of the refined structural models, but may sometimes be advantageous. Such an extension may be particularly beneficial for significantly anisotropic diffraction. Extension of the maximum resolution at the stage of data collection and structure refinement is cheap in terms of the required effort and is definitely more advisable than accepting a too conservative resolution cutoff, which is unfortunately quite frequent among the crystal structures deposited in the Protein Data Bank.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Incorporating microbial dormancy dynamics into soil decomposition models to improve quantification of soil carbon dynamics of northern temperate forests

Abstract Soil carbon dynamics of terrestrial ecosystems play a significant role in the global carbon cycle. Microbial‐based decomposition models have seen much growth recently for quantifying this role, yet dormancy as a common strategy used by microorganisms has not usually been represented and tested in these models against field observations. Here we developed an explicit microbial‐enzyme decomposition model and examined model performance with and without representation of microbial dormancy at six temperate forest sites of different forest types. We then extrapolated the model to global temperate forest ecosystems to investigate biogeochemical controls on soil heterotrophic respiration and microbial dormancy dynamics at different temporal‐spatial scales. The dormancy model consistently produced better match with field‐observed heterotrophic soil CO 2 efflux ( R H ) than the no dormancy model. Our regional modeling results further indicated that models with dormancy were able to produce more realistic magnitude of microbial biomass (<2% of soil organic carbon) and soil R H (7.5 ± 2.4 Pg C yr −1 ). Spatial correlation analysis showed that soil organic carbon content was the dominating factor (correlation coefficient = 0.4–0.6) in the simulated spatial pattern of soil R H with both models. In contrast to strong temporal and local controls of soil temperature and moisture on microbial dormancy, our modeling results showed that soil carbon‐to‐nitrogen ratio (C:N) was a major regulating factor at regional scales (correlation coefficient = −0.43 to −0.58), indicating scale‐dependent biogeochemical controls on microbial dynamics. Our findings suggest that incorporating microbial dormancy could improve the realism of microbial‐based decomposition models and enhance the integration of soil experiments and mechanistically based modeling.

He, Yujie↗