Search NASA⌕ Search

SEARCH · Search NASA

Results for “demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Design Considerations of a Coordinative Demand Charge Mitigation Strategy

This paper presents a coordinative demand charge mitigation (DCM) strategy for reducing electricity consumption during system peak periods. Available DCM resources include batteries, diesel generators, controllable loads, and conservation voltage reduction. All resources are directly controlled by load serving entities. A mixed integer linear programming based energy management algorithm is developed to optimally coordinate of DCM resources considering the load payback effect. To better capture system peak periods, two different kinds of load forecast are used: the day-ahead load forecast and the peak-hour probability forecast. Five DCM strategies are compared for reconciling the discrepancy between the two forecasting results. The DCM strategies are tested using actual utility data. Simulation results show that the proposed algorithm can effectively mitigate the demand charge while preventing the system peak from being shifted to the payback hours. We also identify the diminishing return effect, which can help load serving entities optimize the size of their DCM resources.

Hu, Rongxing↗

Demand Response in Industrial Facilities: Peak Electric Demand

The US Department of Energy’s (DOE’s) Better Buildings, Better Plants Program (Better Plants) is a voluntary energy efficiency leadership initiative for US manufacturers and water/wastewater entities. The program encourages organizations to commit to reducing the energy intensity of their US operations over a 10-year period, typically by 25%. Companies joining Better Plants are recognized by DOE for their leadership in implementing energy efficiency practices and for reducing their energy intensity. Better Plants Partners are assigned to a Technical Account Manager, who can help companies establish energy intensity baselines, develop energy management plans, and identify key resources and incentives from DOE, other federal agencies, states, utilities, and other organizations that can enable them to reach their goals. Better Plants Partners are expected to report their progress to DOE once a year. This involves establishing an energy intensity baseline upon joining the program and then tracking their progress over time. Demand Response in Industrial Facilities: Peak Electrical Demand is intended to help companies understand peak demand response programs offering by their local utility. Manufacturing industries can learn about time-varying rates and smart technologies they can use to help them reduce their energy bills. This guidance document is applicable to companies participating at either the program or challenge level. Although this guide is intended primarily to assist companies participating in Better Plants, the methodologies and guidance within the document are applicable to any organization interested in understanding peak demand response programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demand Response in Industrial Facilities: Peak Electric Demand

The US Department of Energy’s (DOE’s) Better Buildings, Better Plants Program (Better Plants) is a voluntary energy efficiency leadership initiative for US manufacturers and water/wastewater entities. The program encourages organizations to commit to reducing the energy intensity of their US operations over a 10-year period, typically by 25%. Companies joining Better Plants are recognized by DOE for their leadership in implementing energy efficiency practices and for reducing their energy intensity. Better Plants Partners are assigned to a Technical Account Manager, who can help companies establish energy intensity baselines, develop energy management plans, and identify key resources and incentives from DOE, other federal agencies, states, utilities, and other organizations that can enable them to reach their goals. Better Plants Partners are expected to report their progress to DOE once a year. This involves establishing an energy intensity baseline upon joining the program and then tracking their progress over time. Demand Response in Industrial Facilities: Peak Electrical Demand is intended to help companies understand peak demand response programs offering by their local utility. Manufacturing industries can learn about time-varying rates and smart technologies they can use to help them reduce their energy bills. This guidance document is applicable to companies participating at either the program or challenge level. Although this guide is intended primarily to assist companies participating in Better Plants, the methodologies and guidance within the document are applicable to any organization interested in understanding peak demand response programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using Demanded Power and RDE Aggressiveness Metrics to Analyze the Impact of CACC Aggressiveness on Heavy Duty Platooning Power Consumption

Presently, a main mobility sector objective is to reduce its impact on the global greenhouse gas emissions. While there are many techniques being explored, a promising approach to improve fuel economy is to reduce the required energy by using slipstream effects. This study analyzes the demanded engine power and mechanical energy used by heavy-duty trucks during platooning and non-platooning operation to determine the aerodynamic benefits of the slipstream. A series of platooning tests utilizing class 8 semi-trucks platooning via Cooperative Adaptive Cruise Control (CACC) are performed. Comparing the demanded engine power and mechanical energy used reveals the benefits of platooning on the aerodynamic drag while disregarding any potential negative side effects on the engine. However, energy savings were lower than expected in some cases. It was hypothesized that the CACC may have amplified transient platooning events relative to the individual truck baseline results, hampering the potential energy savings. Therefore, the impact of the controller on the observed driving style was analyzed in detail. In order to quantify the transient operational characteristics of the experimental trials, metrics from the European Real Driving Emissions (RDE) legislation were modified to serve as metrics of aggressiveness during platooning. The metrics (v · apos)95 and Relative Positive Acceleration (RPA) were calculated for platooning and non-platooning runs. These results indicate that the CACC induces small acceleration events during platooning to retain the commanded longitudinal separation between vehicles. These small acceleration events increase following vehicle aggressiveness during platooning and prevent the following vehicles from obtaining maximum energy savings. Moreover, a correlation between the RDE metric (v · apos)95 and energy savings is developed. Hence, this work establishes the ability of RDE metrics to assess CACC impacts on platoon energy savings.

European Real Driving Emissions, RDE, greenhouse g↗

Determining and Unlocking Untapped Demand-Side Management Potential in South Africa: Demand Response at the Grid Edge

The National Renewable Energy Laboratory (NREL), funded through the Climate Technology and Change Network (CTCN), has provided technical assistance to key energy sector entities in South Africa to examine untapped demand-side management potential. NREL partnered with the Council for Scientific and Industrial Research (CSIR) and included key South Africa stakeholders: Eskom, the South African National Energy Development Institute (SANEDI), and the Department of Mineral and Resources and Energy (DMRE), including the CTCN National Designated Entity (NDE), the Department of Science and Innovation (DSI). South Africa is currently experiencing an energy crisis with extensive load shedding. While the load shedding crisis in South Africa is a supply side problem, demand-side management provides opportunities to achieve energy efficiency and to reduce peak demand. DSM also has huge potential to help alleviate load shedding, which is a last resort form of DSM.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Potential Solutions to Demand Growth in Virginia: Options for Demand Flexibility [Slides]

This slide deck report presents a literature review on virtual power plants (VPPs) and a demand flexibility analysis for the state of Virginia as part of DOE's State Energy Program (SEP) technical assistance work. The literature review describes key concepts, examples, participation models, and other issues for VPPs, and the analysis section presents a state-specific demand flexibility analysis estimating the technical potential for demand response from various sectors and end-uses. These materials are meant to inform and support VA's ability to shepherd ongoing dialogue and meet energy needs in the midst of strong load growth.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Demand reduction and energy saving potential of thermal energy storage integrated heat pumps [Réduction de la demande et potentiel d'économie d'énergie des pompes à chaleur avec stockage d'énergie thermique intégré]

A heat pump (HP) moves heat from a low-temperature source to a high-temperature sink with an input of energy. Often, one temperature body fluctuates with time (e.g., diurnal ambient temperature), causing the HP efficiency to vary. Integrating thermal energy storage (TES) into a HP system adds a third temperature body, enabling the HP to be advantageously coupled to any two: the application, the ambient, or the TES at strategic times. Although TES integration with HPs is an important emerging technology to lower energy consumption and decrease energy demand during critical times, the favorable circumstances for TES integration are poorly understood. Here, this paper establishes the energy reduction and demand reduction potential of TES-integrated HPs with both analytical and numerical HP models. All possible temperature arrangements are considered for HP-TES systems with two fixed temperature bodies (application and TES) and one variable temperature (ambient). Results show that overall energy savings are most attainable when the TES temperature is near the application temperature, whereas a large temperature difference between the TES and the application leads to the most peak demand reduction. The potential for overall energy savings increases as the magnitude of ambient temperature fluctuations increases.

25 ENERGY STORAGE↗

Distribution Transformer Demand: Understanding Demand Segmentation, Drivers, and Management Through 2050

The National Renewable Energy Laboratory (NREL) has been working closely with the U.S. Department of Energy's Office of Electricity (OE) to understand the critical drivers and potential means of managing distribution transformer demand through 2050. This effort has consulted with utility representative organizations and transformer manufacturers to understand the problem, characterized the in-service assets, and modeled future demand. Distribution transformers, or service transformers, range from 10 to 5,000 kilovolt-amperes (kVA), have a high-side voltage of less than 34.5 kilovolts, and have step-down power delivery for customer end use. This research will help the manufacturing sector understand production requirements and better inform utility strategies for managing their demand.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evolving Electricity Supply and Demand to Achieve Net-Zero Emissions: Insights from the EMF-37 Study

This paper explores the role of electricity in achieving economy-wide net-zero CO2 emissions by 2050 in the United States based on results from 17 models as part of the 37th Stanford Energy Modeling Forum (EMF-37). In the study's Net-Zero scenario, the models use diverse pathways to achieve net-zero emissions by 2050, with gross energy-related residual emissions ranging from 17.2 to 66.6 % of 2020 levels. Electricity consistently emerges as central to achieving net-zero, with models projecting rapid electrification of end-uses and rapidly declining CO2 intensity of electricity. However, the extent of electrification and the technology mix to decarbonize the power sector vary considerably across models. In the Net-Zero scenario, electricity is projected to evolve from ~20 % of final energy in 2020 to 17-63 % in 2050 across the models driven by electrification in all sectors-buildings, industry, and transportation-and, to a lesser extent by direct air capture. By 2050, total electricity consumption increases by 24-176 % (relative to 2020), accompanied by significant expansion in renewable electricity production. Together, solar and wind generation grows by 175-834 %, supplying 45-90 % of total electricity in 2050, with wind achieving slightly higher shares than solar. Electricity storage technologies are deployed at scale to support wind and solar generation. The electricity generation mix varies across models: some project almost complete reliance on renewables, while others see a substantial role for natural gas, often with carbon capture and storage. This paper synthesizes the rich diversity of modeling approaches and results, highlighting differing views on how key drivers of electricity demand and supply might evolve.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

3D-Printed Repeating Re-Entrant Topography to Achieve On-Demand Wettability and Separation

While it is difficult and expensive to fabricate a complicated surface structure via conventional techniques, three-dimensional (3D) printing serves as a time-efficient and cost-efficient alternative. In the current study, a novel repeating re-entrant topography is fabricated by two-photon polymerization 3D printing. The experimental results show that the repeating re-entrant surface enhances the desired on-demand surface wettability. Furthermore, the 3D-printed membranes with the repeating re-entrant structures enable the efficient on-demand separation of liquid mixtures with high flux, which is critical for the wastewater treatment in the chemical industry.

36 MATERIALS SCIENCE↗

Respiratory energy demands and scope for demand expansion and destruction

Photosynthesis is the primary energy input to plants, but most plant metabolic processes are powered much or all of the time by ATP and NAD(P)H that come from respiratory oxidation of photosynthetically produced carbohydrates, that is, “dark respiration” (Amthor, 1994). The processes of growth, nutrient uptake and assimilation, active transport, and maintenance are thus all clients of respiration and compete for their share of a respiratory energy budget that is capped by photosynthate income. The economic principle of opportunity cost applies to these clients’ competing demands: spending respiratory energy on process A means missing the benefit of investing that energy in process B (Mahmoudabadi et al., 2019). This principle is key to assessing prospects for crop improvement by metabolic engineering. As de Lorenzo (2015) put it: “metabolism…frames and ultimately resolves whether a given genetic program (existing…or engineered) can be deployed or not.” Foreign or reconfigured native processes bolted on to a crop-plant’s metabolic chassis must compete for respiratory energy with native ones without crashing the energy economy. A proviso on plant carbon budgets is that photosynthetic carbon fixation (“source activity”) can in certain cases increase to meet increased carbon demand (“sink activity”), that is, budget envelopes are not always fixed (Smith et al., 2018). However, as there is some consensus that productivity is most often limited or co-limited by carbon supply (Ainsworth and Long, 2005; Körner, 2015; Sonnewald and Fernie, 2018), we make this our basal assumption in the analyses below.

59 BASIC BIOLOGICAL SCIENCES↗

Multiscale Effects Masked the Impact of the COVID-19 Pandemic on Electricity Demand in the United States

Shelter-in-place orders and business closures related to COVID-19 changed the hourly profile of electricity demand and created an unprecedented source of uncertainty for the grid. The potential for continued shifts in electricity profiles has implications for electricity sector investment and operating decisions that maintain reserve margins and provide grid reliability. This study reveals that understanding this uncertainty requires an understanding of the underlying drivers at the customer-class scale. This paper utilizes three datasets to compare the impacts of COVID-19 on electricity consumption across a range of spatiotemporal and customer scales. At the utility/customer-class scale, COVID-19-induced shutdowns in the spring of 2020 shifted weekday residential load profiles to resemble weekend profiles from previous years. Total commercial loads declined, but the commercial diurnal load profile was unchanged. With only total loads available at the balancing authority scale, the apparent impact of COVID-19 was smaller during the summer due in part to phased re-opening and spatial variability in re-opening, but there were still clear variations once total loads were broken down zonally. Monthly data at the state scale showed an increase in state-level residential electricity sales, a decrease in commercial sales, and a small net decrease in total sales in most states from April-August 2020. Analyses that focus on total load or a single scale may miss important changes that become apparent when the load is broken down regionally or by customer class.

COVID-19, electricity demand, multiscale, Commonwe↗

The Coupling of Solution Chemistry to Plant Nutrient Demand in an on Demand Nutrient Delivery System

The goal of the proposal will be to determine the suitability of the DASI instrument in providing a signal that can be recognized and be utilized as an indicator of plant stress. The method to be utilized for evaluating stress is the presentation of an every increasing level of nutrient deficiency and salinity stress (addition of salt (NACl) or increasing concentration of balanced nutrient) while simultaneously recording spectral reflectance using the DASI instrument and monitoring the traditional processes of gas exchange and nutrient uptake parameters. In this manner, we will be able to directly compare the DASI measurements with known stresses as determined by the traditional gas exchange and nutrient uptake measures of stress. We anticipate that the DASI will provide a sensitive identifier of plant stress; recording signals of the resulting changes in plant metabolism in real time, far before any visible effects of stress could be observed. Thus, there is a potential for very early management intervention to correct a stress condition before damage could develop. The present response time for the observation of visual symptoms of plant stress is considerable and only provides an indication that a stress is present after it has been present for an extended period of time. Thus, the impact of a plant-based life support function will have already been significant. An additional benefit of this research to regenerative life support will be the characterization of a potential recovery scenario from various degrees of stress. The experimental approach to be employed includes the removal of the stress at various points in the stress gradient and the characterization of plant performance and reflectance spectra during recovery from various degrees of stress. Spectral reflectance imaging techniques have been developed and used to measure the biochemical composition of plants and relate these characteristics to the fluxes of biochemical elements within the ecosystem.

Savage, Wayne↗