Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnosability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Method and system for the diagnosis of disease using retinal image content and an archive of diagnosed human patient data

A method for diagnosing diseases having retinal manifestations including retinal pathologies includes the steps of providing a CBIR system including an archive of stored digital retinal photography images and diagnosed patient data corresponding to the retinal photography images, the stored images each indexed in a CBIR database using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the stored images. A query image of the retina of a patient is obtained. Using image processing, regions or structures in the query image are identified. The regions or structures are then described using the plurality of feature vectors. At least one relevant stored image from the archive based on similarity to the regions or structures is retrieved, and an eye disease or a disease having retinal manifestations in the patient is diagnosed based on the diagnosed patient data associated with the relevant stored image(s).

59 BASIC BIOLOGICAL SCIENCES↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Multiple Fault Diagnosability using Possible Conflicts

Multiple fault diagnosis is a difficult problem for dynamic systems. Due to fault masking, compensation, and relative time of fault occurrence, multiple faults can manifest in many different ways as observable fault signature sequences. This decreases diagnosability of multiple faults, and therefore leads to a loss in effectiveness of the fault isolation step. We develop a qualitative, event-based, multiple fault isolation framework, and derive several notions of multiple fault diagnosability. We show that using Possible Conflicts, a model decomposition technique that decouples faults from residuals, we can significantly improve the diagnosability of multiple faults compared to an approach using a single global model. We demonstrate these concepts and provide results using a multi-tank system as a case study.

multiple faults↗

{sup 68}Ga-PSMA-11 PET/CT in newly diagnosed prostate cancer: diagnostic sensitivity and interobserver agreement

Purpose: To determine the diagnostic sensitivity and interobserver agreement of Gallium 68-prostate-specific membrane antigen positron emission tomography/computed tomography ({sup 68}Ga-PSMA-11 PET/CT) imaging for diagnosis and staging of patients with newly diagnosed prostate cancer (PC). Materials and methods: One hundred and seventy-three men (mean age, 68 ± 7.7 years; range 46–84 years) with newly diagnosed, untreated PC were enrolled in this prospective study between January 2017 and August 2018. All patients underwent a {sup 68}Ga-PSMA-11 PET/CT examination. For each patient, we determined the disease stage, the Gleason score, and the maximum standardized uptake value (SUVmax) for primary prostatic tumor and extraprostatic metastases. The diagnostic sensitivity and interobserver agreement of {sup 68}Ga-PSMA-11 PET/CT for diagnosis and staging of PC were established by histopathology as the reference standard. Results: {sup 68}Ga-PSMA-11 PET/CT examinations were interpreted as positive for PC in 166 of 173 patients (101 patients had primary prostatic tumor only, two patients had extraprostatic metastases only and 63 patients had combined lesions). The sensitivity of {sup 68}Ga-PSMA-11 PET/CT examination in the diagnosis of PC was 96%. {sup 68}Ga-PSMA-11 PET/CT produced a significant change of stage in 28.6% patients with an upstage in 17.9% patients and a downstage in 10.7% patients. The interobserver agreements were almost good to perfect (k = 0.63–0.89) for visual image interpretation, SUVmax measurement, and tumor staging. Conclusion: {sup 68}Ga-PSMA-11 PET/CT is a valuable tool with high diagnostic sensitivity (96%) and high reproducibility for diagnosis and staging of patients with newly diagnosed PC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Medical diagnoses using three-way fuzzy concept lattice and their Euclidean distance

Searching the closest symptoms of a particular disease in the given patient is a major concern for medical diagnoses expert. In most cases, this problem arises due to large number of incomplete, uncertain, or inconsistent information generated in medical diagnoses data set. Recently, some of the researchers tried to pay attention towards precise measurement of uncertainty and vagueness in medical data set using the properties of applied abstract algebra. In this process, researchers noticed that calculus of three-way decision space is more useful to characterize the uncertainty and vagueness in medical data set based on truth, indeterminacy, and falsity membership-values. However, searching some relevant query based on user requirement to diagnoses the disease is a major issue in three-way decision space. To encounter this problem, current paper tried to analyze the medical data set using the properties of single-valued neutrosophic graph-based concept lattice. In addition, another method is proposed to select some of the interesting three-way fuzzy concepts at user-defined granulation for their computed Euclidean distance with an illustrative example.

97 MATHEMATICS AND COMPUTING↗

Perturbations in the Lipid Profile of Individuals with Newly Diagnosed Type 1 Diabetes Mellitus: Lipidomics Analysis of a Diabetes Antibody Standardization Program Sample Subset

Objectives: To characterize the lipid profile of individuals with newly diagnosed type 1 diabetes mellitus using LC-MS-based lipidomics and the accurate mass and time (AMT) tag approach. Design and methods: Lipids were extracted from plasma and sera of 10 subjects from the Diabetes Antibody Standardization Program (years 2000-2005) and 10 non-diabetic subjects and analyzed by capillary liquid chromatography coupled with a hybrid ion-trap-Fourier transform ion cyclotron resonance mass spectrometer. Lipids were identified and quantified using the AMT tag approach. Results: Five hundred sixty lipid features differentiated (q < 0.05) diabetic from healthy individuals in a partial least-squares analysis, characterizing of individuals with recently diagnosed type 1 diabetes mellitus. Conclusions: A lipid profile associated with newly diagnosed type 1 diabetes may aid in further characterization of biochemical pathways involved in lipid regulation or mobilization and lipotoxicity of pancreatic beta-cells.

59 BASIC BIOLOGICAL SCIENCES↗

Addition of Bevacizumab to Standard Radiation Therapy and Daily Temozolomide Is Associated With Minimal Toxicity in Newly Diagnosed Glioblastoma Multiforme

Purpose: To determine the safety of the addition of bevacizumab to standard radiation therapy and daily temozolomide for newly diagnosed glioblastoma multiforme (GBM). Methods and Materials: A total of 125 patients with newly diagnosed GBM were enrolled in the study, and received standard radiation therapy and daily temozolomide. All patients underwent a craniotomy and were at least 2 weeks postoperative. Radiation therapy was administered in 1.8-Gy fractions, with the clinical target volume for the primary course treated to a dose of 45 to 50.4 Gy, followed by a boost of 9 to 14.4 Gy, to a total dose of 59.4 Gy. Patients received temozolomide at 75 mg/m{sup 2} daily throughout the course of radiation therapy. Bevacizumab was given at 10 mg/kg intravenously every 14 days, beginning a minimum of 4 weeks postoperatively. Results: Of the 125 patients, 120 (96%) completed the protocol-specified radiation therapy. Five patients had to stop the protocol therapy, 2 patients with pulmonary emboli, and 1 patient each with a Grade 2 central nervous system hemorrhage, Grade 4 pancytopenia, and wound dehiscence requiring surgical intervention. All 5 patients ultimately finished the radiation therapy. After radiation therapy, 3 patients had progressive disease, 2 had severe fatigue and decreased performance status, 1 patient had a colonic perforation, and 1 had a rectal fissure; these 7 patients therefore did not proceed with the protocol-specified adjuvant temozolomide, bevacizumab, and irinotecan. However, 113 patients (90%) were able to continue on study. Conclusions: The addition of bevacizumab to standard radiation therapy and daily temozolomide was found to be associated with minimal toxicity in patients newly diagnosed with GBM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnosing x-ray power and energy of tungsten wire array z-pinch with a flat spectral response x-ray diode

Fast z-pinch is a very efficient way of converting electromagnetic energy to radiation. With an 8-10 MA current on primary test stand facility, about 1 MJ electromagnetic energy is delivered to vacuum chamber, which heats z-pinch plasma to radiate soft x-ray. To develop a pulsed high power x-ray source, we studied the applicability of diagnosing x-ray power from tungsten wire array z-pinch with a flat spectral response x-ray diode (FSR-XRD). The detector was originally developed to diagnose radiation of a hohlraum in SG-III prototype laser facility. It utilized a gold cathode XRD and a specially configured compound gold filter to yield a nearly flat spectral response in photon energy range of 0.1-4 keV. In practice, it was critical to avoid surface contamination of gold cathode. It is illustrated that an exposure of an XRD to multiple shots caused a significant change of response. Thus, in diagnosing x-ray power and energy, we used each XRD in only one shot after calibration. In a shot serial, output of FSR-XRD was compared with output of a nickel bolometer. In these shots, the outputs agreed with each other within their uncertainties which were about 12% for FSR-XRD and about 15% for bolometer. Moreover, the ratios between the FSR-XRD and the bolometer among different shots were explored. In 8 shots, the standard deviation of the ratio was 6%. It is comparable to XRD response change of 7%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tick bite frequency, prevention practices and Lyme disease diagnoses among U.S. Hispanic survey respondents

Abstract Tick bite prevention practices, knowledge of Lyme disease (LD) symptoms and transmission, and patterns of LD diagnoses among Hispanic persons have been reported but not comprehensively evaluated. In 2014, CDC examined questions from a prospective nationwide survey of U.S. Hispanic adults conducted via the Offerwise QueOpinas panel regarding ticks and LD. From October to November, a total of 2,649 surveys were released and 1,006 completed surveys returned. Overall, 44% of respondents reported routinely practising at least one form of personal protection against tick bites, and wearing repellent was the most commonly reported method (29%). Approximately 6% of respondents reported a tick bite for either themselves or someone in their household during the previous 12 months. An individual or household diagnosis of LD in the previous year was reported by 2% of respondents, with the highest proportion of diagnoses reported by respondents from high LD incidence states. The annual incidence of healthcare provider‐diagnosed LD in the survey population was higher than national surveillance estimates for reported LD among U.S. Hispanic persons during 2000–2013. As annual incidence of LD continues to increase, it is important to ensure equitable access to information about LD, including disease transmission, manifestations, and prevention recommendations. Results from this survey can help inform public health outreach focused on effective tick bite prevention methods and early recognition of LD.

Beck, Alyssa↗

Development of Spectral and Atomic Models for Diagnosing Energetic Particle Characteristics in Fast Ignition Experiments

This Final Report summarizes work performed under DOE STTR Phase II Grant No. DE-FG02-05ER86258 during the project period from August 2006 to August 2009. The project, “Development of Spectral and Atomic Models for Diagnosing Energetic Particle Characteristics in Fast Ignition Experiments,” was led by Prism Computational Sciences (Madison, WI), and involved collaboration with subcontractors University of Nevada-Reno and Voss Scientific (Albuquerque, NM). In this project, we have: Developed and implemented a multi-dimensional, multi-frequency radiation transport model in the LSP hybrid fluid-PIC (particle-in-cell) code [1,2]. Updated the LSP code to support the use of accurate equation-of-state (EOS) tables generated by Prism’s PROPACEOS [3] code to compute more accurate temperatures in high energy density physics (HEDP) plasmas. Updated LSP to support the use of Prism’s multi-frequency opacity tables. Generated equation of state and opacity data for LSP simulations for several materials being used in plasma jet experimental studies. Developed and implemented parallel processing techniques for the radiation physics algorithms in LSP. Benchmarked the new radiation transport and radiation physics algorithms in LSP and compared simulation results with analytic solutions and results from numerical radiation-hydrodynamics calculations. Performed simulations using Prism radiation physics codes to address issues related to radiative cooling and ionization dynamics in plasma jet experiments. Performed simulations to study the effects of radiation transport and radiation losses due to electrode contaminants in plasma jet experiments. Updated the LSP code to generate output using NetCDF to provide a better, more flexible interface to SPECT3D [4] in order to post-process LSP output. Updated the SPECT3D code to better support the post-processing of large-scale 2-D and 3-D datasets generated by simulation codes such as LSP. Updated atomic physics modeling to provide for more comprehensive and accurate atomic databases that feed into the radiation physics modeling (spectral simulations and opacity tables). Developed polarization spectroscopy modeling techniques suitable for diagnosing energetic particle characteristics in HEDP experiments. A description of these items is provided in this report. The above efforts lay the groundwork for utilizing the LSP and SPECT3D codes in providing simulation support for DOE-sponsored HEDP experiments, such as plasma jet and fast ignition physics experiments. We believe that taken together, the LSP and SPECT3D codes have unique capabilities for advancing our understanding of the physics of these HEDP plasmas. Based on conversations early in this project with our DOE program manager, Dr. Francis Thio, our efforts emphasized developing radiation physics and atomic modeling capabilities that can be utilized in the LSP PIC code, and performing radiation physics studies for plasma jets. A relatively minor component focused on the development of methods to diagnose energetic particle characteristics in short-pulse laser experiments related to fast ignition physics. The period of performance for the grant was extended by one year to August 2009 with a one-year no-cost extension, at the request of subcontractor University of Nevada-Reno.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Practical Formal Verification of Diagnosability of Large Models via Symbolic Model Checking

This document reports on the activities carried out during a four-week visit of Roberto Cavada at the NASA Ames Research Center. The main goal was to test the practical applicability of the framework proposed, where a diagnosability problem is reduced to a Symbolic Model Checking problem. Section 2 contains a brief explanation of major techniques currently used in Symbolic Model Checking, and how these techniques can be tuned in order to obtain good performances when using Model Checking tools. Diagnosability is performed on large and structured models of real plants. Section 3 describes how these plants are modeled, and how models can be simplified to improve the performance of Symbolic Model Checkers. Section 4 reports scalability results. Three test cases are briefly presented, and several parameters and techniques have been applied on those test cases in order to produce comparison tables. Furthermore, comparison between several Model Checkers is reported. Section 5 summarizes the application of diagnosability verification to a real application. Several properties have been tested, and results have been highlighted. Finally, section 6 draws some conclusions, and outlines future lines of research.

Cavada, Roberto↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutrondiagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sequential Window Diagnoser for Discrete-Event Systems Under Unreliable Observations

This paper addresses the issue of counting the occurrence of special events in the framework of partiallyobserved discrete-event dynamical systems (DEDS). Developed diagnosers referred to as sequential window diagnosers (SWDs) utilize the stochastic diagnoser probability transition matrices developed in [9] along with a resetting mechanism that allows on-line monitoring of special event occurrences. To illustrate their performance, the SWDs are applied to detect and count the occurrence of special events in a particular DEDS. Results show that SWDs are able to accurately track the number of times special events occur.

97 MATHEMATICS AND COMPUTING↗

Diagnosing phosphorus limitations in natural terrestrial ecosystems in carbon cycle models

Abstract Most of the Earth System Models ( ESMs ) project increases in net primary productivity ( NPP ) and terrestrial carbon (C) storage during the 21st century. Despite empirical evidence that limited availability of phosphorus (P) may limit the response of NPP to increasing atmospheric CO 2 , none of the ESMs used in the previous Intergovernmental Panel on Climate Change assessment accounted for P limitation. We diagnosed from ESM simulations the amount of P need to support increases in carbon uptake by natural ecosystems using two approaches: the demand derived from (1) changes in C stocks and (2) changes in NPP . The C stock‐based additional P demand was estimated to range between −31 and 193 Tg P and between −89 and 262 Tg P for Representative Concentration Pathway ( RCP ) 2.6 and RCP8.5 , respectively, with negative values indicating a P surplus. The NPP ‐based demand, which takes ecosystem P recycling into account, results in a significantly higher P demand of 648–1606 Tg P for RCP2 .6 and 924–2110 Tg P for RCP8 .5. We found that the P demand is sensitive to the turnover of P in decomposing plant material, explaining the large differences between the NPP ‐based demand and C stock‐based demand. The discrepancy between diagnosed P demand and actual P availability (potential P deficit) depends mainly on the assumptions about availability of the different soil P forms. Overall, future P limitation strongly depends on both soil P availability and P recycling on ecosystem scale.

54 ENVIRONMENTAL SCIENCES↗

Recommendations for diagnosing effective radiative forcing from climate models for CMIP6

The usefulness of previous Coupled Model Intercomparison Project (CMIP) exercises has been hampered by a lack of radiative forcing information. This has made it difficult to understand reasons for differences between model responses. Effective radiative forcing (ERF) is easier to diagnose than traditional radiative forcing in global climate models (GCMs) and is more representative of the eventual temperature response. Here we examine the different methods of computing ERF in two GCMs. We find that ERF computed from a fixed sea surface temperature (SST) method (ERF_fSST) has much more certainty than regression based methods. Thirty year integrations are sufficient to reduce the 5–95% confidence interval in global ERF_fSST to 0.1Wm ~2 . For 2xCO2 ERF, 30 year integrations are needed to ensure that the signal is larger than the local confidence interval over more than 90% of the globe. Within the ERF_fSST method there are various options for prescribing SSTs and sea ice. We explore these and find that ERF is only weakly dependent on the methodological choices. Prescribing the monthly averaged seasonally varying model’s preindustrial climatology is recommended for its smaller random error and easier implementation. As part of CMIP6, the Radiative Forcing Model Intercomparison Project (RFMIP) asks models to conduct 30 year ERF_fSST experiments using the model’s own preindustrial climatology of SST and sea ice. The Aerosol and Chemistry Model Intercomparison Project (AerChemMIP) will also mainly use this approach. Lastly, we propose this as a standard method for diagnosing ERF and recommend that it be used across the climate modeling community to aid future comparisons.

54 ENVIRONMENTAL SCIENCES↗

Using discrete Bayesian networks for diagnosing and isolating cross-level faults in HVAC systems

Fault detection and diagnosis (FDD) technologies are critical to ensure satisfactory building performance, such as reducing energy wastes and negative impacts on occupant comfort and productivity. Existing FDD technologies mainly focus on component-level FDD solutions, which could lead to mis-diagnosis of cross-level faults in heating, ventilating, and air-conditioning (HVAC) systems. Cross-level faults are those faults that occur in one component or subsystem, but cause operational abnormalities in other components or subsystems, and result in a building level performance degradation. How to effectively diagnose the root cause of a cross-level fault is the focus of this study. Here, this paper presents a novel discrete Bayesian Network (DisBN)-based method for diagnosing cross-level faults in an HVAC system commonly used in commercial buildings. A two-level DisBN structure model is developed in this study. The parameters used in the DisBN model are obtained either from expert knowledge or through machine-learning strategies from normal system operation data. Meanwhile, the probability parameters are discretized to incorporate the uncertainties associated with typical expert knowledge. Thus, the developed DisBN method addresses the challenges many other BN based FDD methods face, i.e., the lack of fault data for BN parameter training. The developed DisBN represents causal relationships between a fault and its cross-level system impacts (i.e., fault symptoms or fault indicators) by considering how fault impacts propagate across different levels in an HVAC system. A weather and schedule information-based Pattern Matching (WPM) method is employed to automatically create WPM baseline data sets for each incoming real time snapshot data from the building systems. Consequently, BN inference and real-time diagnostics are achieved by comparing incoming snapshot data and the WPM baseline data set. The proposed method is evaluated using experimental fault data collected in a campus building. Fault diagnosis results demonstrate that the WPM-DisBN method is effective at locating the root causes of cross-level faults in an HVAC system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clinical Outcomes of Stereotactic Body Radiotherapy for Small Lung Lesions Clinically Diagnosed as Primary Lung Cancer on Radiologic Examination

Purpose: Image-guided biopsy occasionally fails to diagnose small lung lesions, which are highly suggestive of primary lung cancer. The aim of the present study was to evaluate the outcome of stereotactic body radiotherapy (SBRT) for small lung lesions that were clinically diagnosed as primary lung cancer without pathologic confirmation. Methods and Materials: A total of 115 patients were treated with SBRT in 12 institutions. Tumor size ranged from 5 to 45 mm in diameter, with a median of 20 mm. Results: The 3-year and 5-year overall survival rates for patients with a tumor size <=20 mm in diameter (n = 58) were both 89.8%, compared with 60.7% and 53.1% for patients with tumors >20 mm (n = 57) (p <0.0005), respectively. Local progression occurred in 2 patients (3.4%) with a tumor size <=20 mm and in 3 patients (5.3%) with tumors >20 mm. Among the patients with a tumor size <=20 mm, Grade 2 pulmonary complications were observed in 2 (3.4%), but no Grade 3 to 5 toxicity was observed. In patients with a tumor size >20 mm, Grades 2, 3, and 5 toxicity were observed in 5 patients (8.8%), 3 patients (5.3%), and 1 patient (1.8%), respectively. Conclusion: In patients with a tumor <=20 mm in diameter, SBRT was reasonably safe in this retrospective study. The clinical implications of the high local control rate depend on the accuracy of clinical/radiologic diagnosis for small lung lesions and are to be carefully evaluated in a prospective study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase I Study of Vandetanib With Radiotherapy and Temozolomide for Newly Diagnosed Glioblastoma

Purpose: Increasing evidence has suggested that angiogenesis inhibition might potentiate the effects of radiotherapy and chemotherapy in patients with glioblastoma (GBM). In addition, epidermal growth factor receptor inhibition might be of therapeutic benefit, because the epidermal growth factor receptor is upregulated in GBM and contributes to radiation resistance. We conducted a Phase I study of vandetanib, an inhibitor of vascular endothelial growth factor receptor 2 and epidermal growth factor receptor, in patients with newly diagnosed GBM combined with RT and temozolomide (TMZ). Methods and Materials: A total of 13 GBM patients were treated with vandetanib, radiotherapy, and concurrent and adjuvant TMZ, using a standard '3 + 3' dose escalation. The maximal tolerated dose was defined as the dose with <1 of 6 dose-limiting toxicities during the first 12 weeks of therapy. The eligible patients were adults with newly diagnosed GBM, Karnofsky performance status of {>=}60, normal organ function, who were not taking enzyme-inducing antiepileptic drugs. Results: Of the 13 patients, 6 were treated with vandetanib at a dose of 200mg daily. Of the 6 patients, 3 developed dose-limiting toxicities within the first 12 weeks, including gastrointestinal hemorrhage and thrombocytopenia in 1 patient, neutropenia in 1 patient, and diverticulitis with gastrointestinal perforation in 1 patient. The other 7 patients were treated with 100 mg daily, with no dose-limiting toxicities observed, establishing this dose as the maximal tolerated dose combined with TMZ and RT. Conclusion: Vandetanib can be safely combined with RT and TMZ in GBM patients. A Phase II study in which patients are randomized to vandetanib 100 mg daily with RT and TMZ or RT and TMZ alone is underway.

62 RADIOLOGY AND NUCLEAR MEDICINE↗