Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffraction contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Identification of mechanisms driving heterogeneous void growth in ductile aluminum

Void growth plays a central role in ductile fracture, yet the specific mechanisms that control this remain obscure. Classical models, such as those proposed by Rice and Tracey in 1969, are able to capture average rates of void growth, but cannot capture the heterogeneity of individual void growth. Building on recent work, the present study employs laboratory-based diffraction contrast tomography and in-situ x-ray computed tomography to investigate the effect of grain structure and other microstructural factors on void growth in an Al-2219 alloy. Crystal plasticity finite element (CP-FE) modeling is used alongside experimental data to evaluate the contributions of local mechanical states, grain orientation, grain size, and neighboring microstructural features. No strong linear relationships are found with any of the considered descriptors and void growth rate. Potential complex nonlinear relationships are explored with the use of a random forest regression model, which identifies initial void volume, void aspect ratio, local normal stress state, local shear stress state, and local equivalent plastic strain (EQPS) as features that most improve void growth rate predictions. The combination of these analyses suggests that these features should be prioritized to improve models of void growth.

Diffraction contrast tomography (DCT)↗

4D Observations of the initiation of abnormal grain growth in commercially pure Ni

Abnormal grain growth (AGG), where a small fraction of grains grow faster than others, is critical to predict because it can significantly impact material properties. However, the mechanism behind AGG remains unclear. In this study, laboratory-based x-ray diffraction contrast tomography (LabDCT) is employed to non-destructively track the 3D microstructural evolution of high-purity nickel during the onset of AGG at 800 °C. The initial microstructure state is used to test hypothesized microstructure predictors of the initiation of AGG. The change in grain size was not related to the initial grain size or normalized integral mean curvature. Additionally, the grain boundary energy distributions of abnormal grains were indistinguishable from those of control groups exhibiting normal grain growth. However, the grains that later became abnormal exhibit large areas of asymmetric tilt boundaries that were previously found to be fast. This 3D microstructure dataset is useful to investigate new hypotheses for the initiation of AGG.

36 MATERIALS SCIENCE↗

3d Crystallographic Orientation of Olivine in Bjurböle Chondrules

The crystallographic orientations of chondrule minerals can provide important insights into their formation and deformational history. For example, the orientations of the olivine bars and surrounding rim in barred olivine chondrules provide information and on the conditions of crystallization and the orientations and shapes of olivines within porphritic chondrules can record the reactions with the surrounding nebular gas during chondrule formation. Later deformation on the parent body can cause crystal-plastic deformation of chondrule minerals that is evident through their intracrystalline lattice misorientations. Typically these crystal orientations and lattice misorientations are determined using electron backscatter diffraction (EBSD) on thin sections but this gives only a 2D picture for what is actually a 3D texture. While it is possible to combine EBSD with serial sectioning to build a 3D dataset of texture, this is a destructive, time-intensive process. A recent technological development that enables non-destructive, 3D crystallographic orientation measurement is X-ray diffraction contrast tomography (DCT), which uses the X-ray diffraction of the crystal lattice to determine orientation. Originally only possible using monochromatic X-ray beams at 3rd generation synchrotron light sources, DCT has been recently adapted to polychromatic sources of laboratory X-ray microscopes (referred to as Lab-DCT). Up to this point LabDCT has only been applied to large, well-formed crystals of high symmetry (i.e., metals), but we recently acquired DCT datasets for a pair Bjurböle chondrules to determine the applicability of the technique to natural, mutlimineralic samples composed predominately of olivine (i.e., chondrules).

Hanna, R. D.↗

Full-field X-ray reflection microscopy of epitaxial thin-films

Novel X-ray imaging of structural domains in a ferroelectric epitaxial thin film using diffraction contrast is presented. The full-field hard X-ray microscope uses the surface scattering signal, in a reflectivity or diffraction experiment, to spatially resolve the local structure with 70 nm lateral spatial resolution and sub-nanometer height sensitivity. Sub-second X-ray exposures can be used to acquire a 14 µm × 14 µm image with an effective pixel size of 20 nm on the sample. The optical configuration and various engineering considerations that are necessary to achieve optimal imaging resolution and contrast in this type of microscopy are discussed.

interfaces and thin films↗

Toward high-throughput defect density quantification: A comparison of techniques for irradiated samples

Transmission electron microscopy (TEM) is an established tool used for the investigation of defects in materials. Traditionally, diffraction contrast techniques—two-beam bright-field and weak-beam dark-field—have been used to image defects due to contrast sensitivity from weak lattice strains. Use of these methods entail an intricate tilt series of imaging using different diffracting vectors, g, to verify the g•b invisibility criterion relative to the different defect types and habit planes inherent to the material. Recently, the addition of down-zone imaging and STEM imaging has also proven to be effective imaging techniques for defect density analysis. Interest in nanocrystalline (NC) materials, spurred by their conjectured superior properties compared to their coarse-grain counterparts, has been thriving and the investigation of their defect morphologies is essential. Maneuvering within NC samples in the TEM adds another layer of difficulty making the aforementioned techniques not practical for application to specimens with complex microstructures. For this reason, we have devised a protocol for identifying NC grains optimally oriented for quantitative analysis using NanoMegas ASTAR automated crystal orientation mapping (ACOM) in the TEM. In this work, we conduct a series of experiments assessing the effectiveness of conventional two-beam bright-field, weak-beam dark-field, and down-zone STEM imaging. Here, we also evaluate an ACOM-assisted multibeam imaging method and compare defect density results obtained using each technique in an irradiated nanocrystalline Au sample.

36 MATERIALS SCIENCE↗

A large field-of-view high-resolution hard x-ray microscope using polymer optics

Here, we present an effective approach using a matched pair of polymer-based condenser-objective lenses to build a compact full-field X-ray microscope with a high spatial resolution. A unique condenser comprising arrays of high-aspect-ratio prisms with equilateral cross-section is used for uniformly illuminating samples over a large field of view (FoV) from all angles, which match the acceptance of an objective made of interdigitated orthogonal rows of one-dimensional lenses. State-of-the-art Talbot grating interferometry used to characterize these lenses for the first time revealed excellent focusing properties and minimal wave-front distortions. Using a specific lens-pair designed for 20 keV X-rays, short-exposure times, and image registration with a cross-correlation technique, we circumvent vibrational instabilities to obtain distortion-free images with a uniform resolution of 240 nm (smallest resolvable line pair) over a large FoV, 80 × 80 µm 2 in extent. The results were contrasted with those collected under illumination using commercial two-dimensional parabolic lenses with a smaller FoV. This approach implemented on a diffractometer would enable diffraction-contrast or dark-field microscopy for fast observations of ‘mesoscopic’ phenomena in real space complementing reciprocal-space studies using diffraction on the same instrument.

47 OTHER INSTRUMENTATION↗

Application of Electron Backscatter Diffraction to Phase Identification

The identification of crystalline phases in solids requires knowledge of two microstructural properties: crystallographic structure and chemical composition. Traditionally, this has been accomplished using X-ray diffraction techniques where the measured crystallographic information, in combination with separate chemical composition measurements for specimens of unknown pedigrees, is used to deduce the unknown phases. With the latest microstructural analysis tools for scanning electron microscopes, both the crystallography and composition can be determined in a single analysis utilizing electron backscatter diffraction and energy dispersive spectroscopy, respectively. In this chapter, we discuss the approach required to perform these experiments, elucidate the benefits and limitations of this technique, and detail via case studies how composition, crystallography, and diffraction contrast can be used as phase discriminators.

36 MATERIALS SCIENCE↗

Imposing equilibrium on experimental 3-D stress fields using Hodge decomposition and FFT-based optimization

Here, we present a methodology to impose micromechanical constraints, i.e. stress equilibrium at grain and sub-grain scale, to an arbitrary (non-equilibrated) voxelized stress field obtained, for example, by means of synchrotron X-ray diffraction techniques. The method consists in finding the equilibrated stress field closest (in L 2 -norm sense) to the measured non-equilibrated stress field, via the solution of an optimization problem. The extraction of the divergence-free (equilibrated) part of a general (non-equilibrated) field is performed using the Hodge decomposition of a symmetric matrix field, which is the generalization of the Helmholtz decomposition of a vector field into the sum of an irrotational field and a solenoidal field. The combination of: a) the Euler–Lagrange equations that solve the optimization problem, and b) the Hodge decomposition, gives a differential expression that contains the bi-harmonic operator and two times the curl operator acting on the experimental stress field. These high-order derivatives can be efficiently performed in Fourier space. The method is applied to filter the non-equilibrated parts of a synthetic piecewise constant stress fields with a known ground truth, and stress fields in Gum Metal, a beta-Ti-based alloy measured in-situ using Diffraction Contrast Tomography (DCT). In both cases, the largest corrections were obtained near grain boundaries.

36 MATERIALS SCIENCE↗

Basal slip and texture development in calcite: new results from torsion experiments

The deformation behavior of calcite has been of longstanding interest. Through experiments on single crystals, deformation mechanisms were established such as mechanical twinning on e = {l_brace}{bar 1}018{r_brace} <40{bar 4}1> in the positive sense and slip on r = {l_brace}10{bar 1}4{r_brace} <20{bar 2}{bar 1}> and f = {l_brace}{bar 1}012{r_brace} <0{bar 2}2{bar 1}> both in the negative sense. More recently it was observed that at higher temperatures f{l_brace}{bar 1}012{r_brace} <10{bar 1}1> slip in both senses becomes active and, based on slip line analysis, it was suggested that e(0001) <11{bar 2}0> slip may occur. So far there had been no direct evidence for basal slip, which is the dominant system in dolomite. With new torsion experiments on calcite single crystals at 900 K and transmission electron microscopy, this study identifies (0001) <11{bar 2}0> slip unambiguously by direct imaging of dislocations and diffraction contrast analysis. Including this slip system in polycrystal plasticity simulations, enigmatic texture patterns observed in compression and torsion of calcite rocks at high temperature can now be explained, resolving a long-standing puzzle.

58 GEOSCIENCES↗

Electron tomography of dislocation structures

Recent developments in the application of electron tomography for characterizing microstructures in crystalline solids are described. The underlying principles for electron tomography are presented in the context of typical challenges in adapting the technique to crystalline systems and in using diffraction contrast imaging conditions. Methods for overcoming the limitations associated with the angular range, the number of acquired images, and uniformity of image contrast are introduced. In addition, a method for incorporating the real space coordinate system into the tomogram is presented. As the approach emphasizes development of experimental solutions to the challenges, the solutions developed and implemented are presented in the form of examples.

36 MATERIALS SCIENCE↗

Deep learning of structural morphology imaged by scanning X-ray diffraction microscopy

Scanning X-ray nanodiffraction microscopy is a powerful technique for spatially resolving nanoscale structural morphologies by diffraction contrast. One of the critical challenges in experimental nanodiffraction data analysis is posed by the convergence angle of nanoscale focusing optics which creates simultaneous dependency of the far-field scattering data on three independent components of the local strain tensor-corresponding to dilation and two potential rigid body rotations of the unit cell. All three components are in principle resolvable through a spatially mapped sample tilt series; however, traditional data analysis is computationally expensive and prone to artifacts. In this study, we implement NanobeamNN, a convolutional neural network specifically tailored to the analysis of scanning probe X-ray microscopy data. NanobeamNN learns lattice strain and rotation angles from simulated diffraction of a focused X-ray nanobeam by an epitaxial thin film and can directly make reasonable predictions on experimental data without the need for additional fine-tuning. We demonstrate that this approach represents a significant advancement in computational speed over conventional methods, as well as a potential improvement in accuracy over the current standard.

Luo, Aileen [Cornell Univ., Ithaca, NY (United Sta↗

Three-dimensional imaging of dislocations by X-ray diffraction laminography

Synchrotron radiation laminography with X-ray diffraction contrast enables three-dimensional imaging of dislocations in monocrystalline wafers. We outline the principle of the technique, the required experimental conditions, and the reconstruction procedure. The feasibility and the potential of the method are demonstrated by three-dimensional imaging of dislocation loops in an indent-damaged and annealed silicon wafer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of high Curie temperature (1-x)BiSc{sub 1-y}Fe{sub y}O{sub 3}-xPbTiO{sub 3} piezoelectric ceramics

Ceramics around the morphotropic phase boundary (MPB) in the (1-x)BiSc{sub 1-y}Fe{sub y}O{sub 3}-xPbTiO{sub 3} solid solution were fabricated. For y=0.5, ceramics were single phase, and piezoelectric coefficients (d{sub 33}) and electromechanical coupling coefficients (k{sub p}) for MPB compositions were 300 pC/N and 0.49, respectively; a level of piezoelectric activity similar to that of hard, lead zirconate titanate compositions but with T{sub C}approx60 deg. C higher at approx440 deg. C. For ceramics with y>=0.7, dielectric measurements in combination with diffraction contrast transmission electron microscopy revealed the existence of two ferroelectric phases for most PbTiO{sub 3} contents studied. The presence of two ferroelectric phases was associated with a decrease in piezoelectric activity and although raw materials costs for y=0.7 and 0.8 with respect to y=0 were significantly lower (less Sc{sub 2}O{sub 3}) and T{sub C} greater (approx500 deg. C), d{sub 33} (approx100 pC/N) and k{sub p} (0.18) were too low to be commercially useful for actuator applications.

36 MATERIALS SCIENCE↗

A TEM Study of Creep Deformation Mechanisms in Allvac 718Plus

A preliminary study on the evolution of creep deformation substructure in Ni-base superalloy Allvac 718Plus has been performed. Specimens crept at 620 MPa and at temperatures ranging from 690-732 C were examined utilizing diffraction contrast TEM characterization techniques. Creep was interrupted at 1-2.5% strain in order to study the deformation substructure following a limited amount of deformation. The dominant deformation modes at each of the test temperatures were highly planar in nature and involved shearing of the matrix and precipitates on {111} glide planes. In addition, paired a/2<110> dislocations were evident which suggest an antiphase boundary shearing mechanism. Creep induced microtwinning was also observed at the highest creep temperature which was created by identical a/6<112> Shockley partial dislocations that shear the matrix and precipitates on consecutive close packed {111} glide planes.

36 MATERIALS SCIENCE↗

Imaging a solvent-swollen polymer gel network by open liquid transmission electron microscopy

Visualizing the network of a solvent-swollen polymer gel remains problematic. To address this challenge, open transmission electron microscopy (TEM) was applied to thin gel films permeated by a nonvolatile ionic liquid. The targeted physical gels were prepared by cooling concentrated solutions of poly(ethylene glycol) in 1-ethyl-3-methyl imidazolium ethyl sulfate [EMIM][EtSO 4 ]. During the cooling, gelation occurred by a frustrated crystallization of the dissolved polymer, leading to a percolated, solvent-permeated semicrystalline network in which nanoscale polymer crystals acted as crosslinks. Crystalline features ranging from ~5 to ~200 nm were observed, with the visible network strands dominantly consisting of long curvilinear crystallites of ~15–20 nm diameter. Nascent spherulites irregularly decorated the network, creating a complex structural hierarchy that complicated analyses. Lacking diffraction contrast, TEM did not visualize the many disordered, fully solvated PEG chains present in the voids between crystals. Finally, recognizing that a network's three dimensionality is ambiguous when assessed through two-dimensional microscopy projections, a small gel region was studied by TEM tomography, revealing a nearly isotropic three-dimensional arrangement of the curvilinear crystallites, which displayed remarkably uniform cylindrical cross sections.

36 MATERIALS SCIENCE↗

Laboratory-Based Micro-X-ray Computed Tomography of Energy Materials at Idaho National Laboratory

Abstract The Idaho National Laboratory (INL) has implemented laboratory-based micro-X-ray computed tomography in a laboratory equipped for the examination of highly radioactive samples. This capability provides nondestructive three-dimensional volumetric information on samples to inform subsequent traditional destructive examinations as well as real-world inputs for high-fidelity scientific modeling. Samples can be imaged with spatial resolutions ranging from several hundred nm/voxel up to ~ 100 µm/voxel. The best usable spatial resolution achieved to date is 384 nm/voxel with this instrument, while the highest radiological dose rate of a sample imaged is ~ 60 R/h β/γ on contact. Advanced data analysis, including custom tomographic reconstruction and segmentation methods, have also been developed to support this capability. In addition to traditional digital X-ray radiography and tomography, this instrument is also able to visualize in situ tensile and compression testing as well as perform diffraction contrast tomography. This work describes the X-ray computed tomography post-irradiation examination capabilities at INL, as well as detailing a variety of applications this instrument has examined.