Investigating the performance of an ion luminescence probe as a multichannel fast-ion energy spectrometer using pulse height analysis

We investigate the capability of a fast-ion luminescent probe to operate as a pulse height ion energy analyzer. An existing high sensitivity system has been reconfigured as a single channel ion detector with an amplifier to give a bandwidth comparable to the phosphor response time. A digital pulse processing method has been developed to determine pulse heights from the detector signal so as to obtain time-resolved information on the ion energy distribution of the plasma ions lost to the wall of the TJ-II stellarator. Finally, the potential of this approach for magnetic confined fusion plasmas is evaluated by studying representative TJ-II discharges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Photoneutrons from Depleted Uranium and Comparison Study Using MCNPX-PoliMi

High-energy photon interrogation is a nondestructive technique that is used to detect special nuclear materials and characterize nuclear waste. The development of such systems is complex and requires Monte Carlo simulations to optimize system performance. Monte Carlo simulations rely on various scattering, absorption, and photonuclear cross-section data. While the scattering and absorption cross-section data have been extensively studied and validated with experiments, the results obtained from photonuclear simulations are often found to underpredict measured results, indicating uncertainties in the photonuclear cross sections themselves. Thus, there is a need for new measured results that can be used to quantify underpredictions in simulations using photonuclear cross-section data. In the present work, we interrogated depleted uranium with a 9-MV electron linac and detected photoneutrons with trans-stilbene organic scintillators. The measurement of photoneutrons with organic scintillators is challenging due to the presence of the intense photon flux, which causes issues such as pulse pile-up, detector saturation, and poor signal-to-background ratio. To mitigate these challenges, we used iron and polyethylene shielding of varying thicknesses around the depleted uranium target and a neural network–based digital pulse processing algorithm to recover neutron and photon information from piled-up events. Our goal was to compare the measured photoneutron count rate with the simulated rate obtained using the MCNPX-PoliMi transport code. For a light output window of 0.28 to 2.67 MeVee (1.66- to 6.85-MeV proton recoil energy), we found that the simulated count rate obtained using the ENDF/B-VII photonuclear cross-section library underpredicts the measured rate by 32.8% 3.2%. Additionally, we compared the simulated and measured photoneutron light output distributions. For the least thicknesses of shielding, the simulation was found to underpredict measurements in the 0.70- to 2.67-MeVee light output window. For the greatest thicknesses of shielding, the simulation was found to underpredict the measurement across the entire light output window of 0.28 to 2.67 MeVee.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Shape coexistence in Ni 68

The internal-conversion and internal-pair-production decays of the first excited 0 + state in 68 Ni are studied following the β decay of 68 Co. A novel experimental technique, in which the ions of 68 Co were implanted into a planar germanium double-sided strip detector and which required digital pulse processing, is developed. The values for the energy of the first excited 0 + state and the electric monopole transition strength from the first excited 0 + state to the ground state in 68 Ni are determined to be 1605(3) keV and 7.6 (4) × 10 -3 , respectively. Comparisons of the experimental results to Monte Carlo shell-model calculations suggest the coexistence between a spherical ground state and an oblate first excited 0 + state in 68 Ni.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision Measurements with Low Energy Neutrons (Final Report)

This project encompassed fives years of effort in three areas of precision measurements with low energy neutrons: a) hadronic weak interactions, b) decay correlations, and c) electric dipole moment. These experiments encompass the scientific program of the Fundamental Neutron Physics Beamline (FnPB) at the SNS, ORNL. This grant supported our responsibilities in each of the approved experiments at the FnPB (in order of schedule): NPDGamma (post run), n- 3 He (taking data), Nab (Jan 2016), and nEDM, in addition to the BL3 beamline lifetime experiment at NIST. We focused on three principal activities: a) development of techniques for the design a fabrication of low-field precision surface current electromagnetic coils, b) development of high-speed digital acquisition systems involving real-time digital pulse processing, and high-volume offline waveform processing, and c) experimental data analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Digital Signal Processing of Radar Pulse Echoes

Modern high-performance radar systems are employing ever-more Digital Signal Processing (DSP), replacing ever-more formerly analog components. Precisely predicting the performance of digital filters and correlators requires an awareness of some of the finer points and characteristics of digital filters. We examine a representative radar receiver DSP chain that is processing a Linear Frequency Modulated (LFM) chirp.

47 OTHER INSTRUMENTATION↗

A Multi-Layer Phoswich Radioxenon Detection System, Reporting Period 07/01/07 - 09/30/07

During this quarter, the detector manufacturer (Saint-Gobain) delivered one side of the prototype two-channel phoswich detector (XEPHWICH). Once received, our Digital Pulse Processor (DPP1, 12-bit/100 MHz) was employed to capture and digitally process phoswich pulses from laboratory radioactive sources. Our previous pulse shape discrimination algorithm was modified by utilizing three trapezoidal digital filters. This algorithm provides a two-dimensional plot in which the pulse shapes of interest are classified and then can be well identified. The preliminary experimental results will be presented at the 2007 Informal Xenon Monitoring Workshop. The DPP2 (two-channel, 12-bit/ 250 MHz Digital Pulse Processor) is at the prototyping stage. The analog sections have been designed, prototyped and tested. A 6-layer Printed Circuit Board (PCB) was designed, ordered and delivered. The board components were ordered and are now being assembled and examined for proper functionality. In addition, the related FPGA hardware description code (using VHDL) is under development and simulation. Additionally, our researchers have been studying materials regarding wavelet transforms for incorporation into the project. Wavelet transform is an interesting tool for signal processing; one use for our purpose would be to de-noise the detector signal and to express the signal in a few coefficients for signal compression and increased speed. Light capture efficiency modeling and analysis was performed on the XEPHWICH design. Increased understanding of the modeling software was obtained by the discovery of a bug and successful workaround techniques with the DETECT2000 software. Further modeling and plot generation experience was had by the continued use of CERN's ROOT and GEANT4 software packages. Simulations have been performed to compare the output of points versus planes in light capture efficiency. An additional simulation was made with a runtime that was an order-of-magnitude greater than previous simulations, to confirm convergence of the solutions provided by our software methods. We have initiated our investigation into the radon signature expected in our XEPHWICH system. We intend to utilize this signature to confirm earth movement, in the event of an underground nuclear explosion, by continuously monitoring radon levels and noting increases in radon concentration in conjunction with increased levels of radioxenons. The research group is also designing and constructing a fission chamber to be used for the collection of radioxenon gases following neutron bombardment of HEU in the Oregon State University TRIGA reactor. To this point, we have completed milling the aluminum housing and have modeled fission product nuclide production associated with the fissioning of HEU. Additionally, the students have been busy compiling the appropriate information in preparation for irradiation approvals. Using beta spectra of three initial nuclides collected on the prototype phoswich detector, spectral identification by a preliminary neural network was compared to that of solvers of a linear system of equations. Pre-processing in areas such as smoothing and endpoint identification is also being investigated as a means of improving spectral identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of neutron diagnostics on the experimental advanced superconducting tokamak

Neutron diagnostics have become a significant means to study energetic particles in high power auxiliary heating plasmas on the Experimental Advanced Superconducting Tokamak (EAST). Several kinds of neutron diagnostic systems have been implemented for time-resolved measurements of D-D neutron flux, fluctuation, emission profile, and spectrum. All detectors have been calibrated in laboratory, and in situ calibration using {sup 252}Cf neutron source in EAST is in preparation. A new technology of digitized pulse signal processing is adopted in a wide dynamic range neutron flux monitor, compact recoil proton spectrometer, and time of flight spectrometer. Improvements will be made continuously to the system to achieve better adaptation to the EAST’s harsh γ-ray and electro-magnetic radiation environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Holistic digital gamma-ray spectroscopy methods and instrumentation for high-throughput high-resolution applications

Method of real-time adaptive digital pulse signal processing for high count rate gamma-ray spectroscopy applications includes receiving a preamplifier signal at a pulse deconvolver, the preamplifier signal including resolution deterioration resulting from pulse pile-up. The method further includes generating a deconvoluted signal, by the pulse deconvolver, from the preamplifier signal, the deconvoluted signal having less resolution deterioration as compared to the received preamplifier signal. The method furthermore includes shaping of the deconvoluted signal by a trapezoid filter, the shaping comprising adjusting a shaping parameter of the trapezoid filter for an incoming signal based on a time separation from a subsequent incoming signal.

Hawari, Ayman I.↗

Digitized two-parameter spectrometer for neutron-gamma mixed field

This paper shows the results of digital processing of output pulses from combined photon-neutron detector using a commercially available digitizer ACQUIRIS DP 210. The advantage of digital processing is reduction of the apparatus in weight and size, acceleration of measurement, and increased resistance to pile-up of pulses. The neutron and photon spectrum of radionuclide source {sup 252}Cf is presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real Time Pulse Pile-up Recovery in a High Throughput Digital Pulse Processor

Detection and measurement of radiation is used extensively for non-invasive material characterization in a range of industries. However, many practical applications are frustrated by pulse pile-up within the detector. Pulse pile-up, which occurs when multiple radiation events arrive within the temporal resolving time of the detector, degrades the fidelity of subsequent material analysis. Traditional pulse processing techniques use fast digital filters and logic circuits to detect piled-up events and discard the corrupted data, however, this leads to substantial detector dead time. Consequently, there is considerable interest in more complex signal-processing algorithms to extend the performance of pulse processors and improve material characterization techniques. We present a technology for real-time decoding of pulse pile-up events. It is a model-based signal-processing algorithm able to accurately characterize the number, time-of-arrival and energy of all events in the detector output. Even in the presence of severe multi-pulse pile-up, the composite events are decoded and the energy and time-of-arrival recovered. The technology has been evaluated using a range of detectors, sources and count rates. An exceptional improvement over traditional pulse processing techniques is demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Channel Data Acquisition System for Nuclear Pulse Processing

We have developed a compact, inexpensive electronics package that can digitize pulse-mode or current-mode data from 32 detector outputs in parallel. The electronics package consists of two circuit boards: a custom acquisition board and an off-the-shelf processing board. The acquisition board features a custom-designed integrated circuit that contains an array of charge-to-pulse-width converters. The processing board contains a field programmable gate array that digitizes the pulse widths, performs event discrimination, constructs energy histograms, and executes any user-defined software. Together, the two boards cost around $1000. The module can transfer data to a computer or operate entirely as a standalone system. The design achieves 0.20% nonlinearity and 0.18% FWHM precision at full scale. However, the overall performance could be improved with some modifications to the integrated circuit.

application specific integrated circuit↗

Positron annihilation lifetime spectroscopy using fast scintillators and digital electronics

Positron Annihilation Lifetime Spectroscopy (PALS) is a non-destructive radiological technique widely used in material science studies. PALS typically relies on an analog coincidence measurement setup and allows the estimate of the positron lifetime in a material sample under investigation. The positron trapping at vacancies in the material results in an increased positron lifetime. In this work, we have developed and optimized a PALS experimental setup using organic scintillators, fast digitizers, and advanced pulse processing algorithms. We tested three pairs of different organic scintillators: EJ-309 liquid, EJ-276 newly developed plastic, and BC- 418 plastic, and optimized the data processing parameters for each pair separately. Our high-throughput data analysis method is based on single-pulse interpolation and a constant fraction discrimination (CFD) algorithm. The setup based on the BC-418 detector achieved the best time resolution of 198.3 ± 0.8 ps. We used such optimized setup to analyze two single-crystal quartz samples and found lifetimes of 161 ± 4 ps, 343 ± 12 ps and 1.34 ± 0.05 ns, in good agreement with the characteristic time constants of this material. The proposed experimental set up achieves a time resolution comparable to the minimum positron lifetime in quartz, which makes it possible to accurately characterize material vacancies by discriminating between the lifetimes of either the spin singlet or triplet states of positronium. The optimized data processing algorithms are relevant to all the applications where fast timing is important, such as nuclear medicine and radiation imaging

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the neutron response anisotropy in crystalline organic scintillators.

An anisotropy in the response of crystalline organic scintillators such as anthracene to neutron elastic scattering interactions has been known for some time. Both the amplitude and the time structure of the scintillation light pulse vary with the direction of the proton recoil with respect to the crystalline axes. In principle, this effect could be exploited to develop compact, high-efficiency fast neutron detectors that have directional sensitivity via a precise measurement of the pulse shape. We are investigating the feasibility and sensitivity of such a detector, particularly for neutrons in the fission energy spectrum. Here we will report new measurements of the pulse shape dependence on proton recoil angle in anthracene and stilbene single crystals, for proton energies in the few MeV range. Digital pulse acquisition and processing are used to allow an exploration of different pulse shape analysis techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gamma ray spectroscopy employing divalent europium-doped alkaline earth halides and digital readout for accurate histogramming

A scintillator radiation detector system according to one embodiment includes a scintillator; and a processing device for processing pulse traces corresponding to light pulses from the scintillator, wherein pulse digitization is used to improve energy resolution of the system. A scintillator radiation detector system according to another embodiment includes a processing device for fitting digitized scintillation waveforms to an algorithm based on identifying rise and decay times and performing a direct integration of fit parameters. A method according to yet another embodiment includes processing pulse traces corresponding to light pulses from a scintillator, wherein pulse digitization is used to improve energy resolution of the system. A method in a further embodiment includes fitting digitized scintillation waveforms to an algorithm based on identifying rise and decay times; and performing a direct integration of fit parameters. Additional systems and methods are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

White Rabbit Time Synchronization for Radiation Detector Readout Electronics

As radiation detector arrays in nuclear physics applications become larger and physically more separated, the time synchronization and trigger distribution between many channels of detector readout electronics become more challenging. Clocks and triggers are traditionally distributed through dedicated cabling, but newer methods such as the IEEE 1588 Precision Time Protocol and White Rabbit allow clock synchronization through the exchange of timing messages over Ethernet. Consequently, we report here the use of White Rabbit in a new detector readout module, the Pixie-Net XL. Herein, the White Rabbit core, data capture from multiple digitizing channels, and subsequent pulse processing for pulse height and constant fraction timing are implemented in a Kintex 7 FPGA. The detector data records include White Rabbit time stamps and are transmitted to storage through the White Rabbit core's gigabit Ethernet data path or a slower diagnostic/control link using an embedded Zynq processor. The performance is characterized by time-of-flight style measurements and by time correlation of high energy background events from cosmic showers in detectors separated by longer distances. Software for the Zynq processor can implement "software triggering", for example to limit recording of data to events where a minimum number of channels from multiple modules detect radiation at the same time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Applying the new gamma ray imager diagnostic to measurements of runaway electron Bremsstrahlung radiation in the DIII-D Tokamak (invited)

A new gamma ray imager (GRI) is developed to probe the electron distribution function with 2D spatial resolution during runaway electron (RE) experiments at the DIII-D tokamak. The diagnostic is sensitive to 0.5–100 MeV gamma rays, allowing characterization of the RE distribution function evolution during RE growth and dissipation. The GRI consists of a lead “pinhole camera” mounted on the DIII-D midplane with 123 honeycombed tangential chords 20 cm wide that span the vessel interior. Up to 30 bismuth germanate (BGO) scintillation detectors capture RE bremsstrahlung radiation for Pulse Height Analysis (PHA) capable of discriminating up to 20 000 pulses per second. Digital signal processing routines combining shaping filters are performed during PHA to reject noise and record gamma ray energy. The GRI setup and PHA algorithms will be described and initial data from experiments will be presented. A synthetic diagnostic is developed to generate the gamma ray spectrum of a GRI channel given the plasma information and a prescribed distribution function. Magnetic reconstructions of the plasma are used to calculate the angle between every GRI sightline and orient and discriminate gamma rays emitted by a field-aligned RE distribution function.