Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct counts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Dark energy survey year 3 results: likelihood-free, simulation-based w CDM inference with neural compression of weak-lensing map statistics

We present simulation-based cosmological wcold dark matter (wCDM) inference using dark energy survey year 3 weak-lensing maps, via neural data compression of weak-lensing map summary statistics: power spectra, peak counts, and direct map-level compression/inference with convolutional neural networks (CNN). Using simulation-based inference, also known as likelihood-free or implicit inference, we use forward-modelled mock data to estimate posterior probability distributions of unknown parameters. This approach allows all statistical assumptions and uncertainties to be propagated through the forward-modelled mock data; these include sky masks, non-Gaussian shape noise, shape measurement bias, source galaxy clustering, photometric redshift uncertainty, intrinsic galaxy alignments, non-Gaussian density fields, neutrinos, and non-linear summary statistics. We include a series of tests to validate our inference results. This paper also describes the Gower Street simulation suite: 791 full-sky pkdgrav3 dark matter simulations, with cosmological model parameters sampled with a mixed active-learning strategy, from which we construct over 3000 mock dark energy survey lensing data sets. For wCDM inference, for which we allow –1 < w < –$\frac{1}{3}$⁠, our most constraining result uses power spectra combined with map-level (CNN) inference. Using gravitational lensing data only, this map-level combination gives Ω m = 0.283$^{+0.020}_{–0.027}$⁠, S 8 = 0.804$^{+0.025}_{–0.017⁠}$, and w < –0.80 (with a 68 per cent credible interval); compared to the power spectrum inference, this is more than a factor of two improvement in dark energy parameter (Ω⁠ DE , w⁠) precision.

79 ASTRONOMY AND ASTROPHYSICS↗

Accelerating fissile material detection with a neutron source

A system discriminating fissile material from nonfissile material wherein a digital data acquisition unit collects data at high rate, and processes large volumes of data directly to count neutrons from the unknown source and detect excess grouped neutrons to identify fission. The system includes a Poisson neutron generator for in-beam interrogation of a possible fissile neutron source and inducing neutron emission therefrom, and a DC power supply that exhibits electrical ripple of less than one part per million. A neutron count histogram and Poisson count distribution are overlaid to provide a visual indication of the difference in correlation of natural and induced emitted neutrons from the radiation source to characterize the neutron source as fissile material or non-fissile material.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Accelerating fissile material detection with a neutron source

A method of discriminating fissile material from non-fissile material with a digital data acquisition system that collects data at high rate, and processes large volumes of data directly to count neutrons from the unknown source and detect excess grouped neutrons to identify fission. The system includes a Poisson neutron generator for in-beam interrogation of a possible fissile neutron source and inducing neutron emission therefrom, and a DC power supply that exhibits electrical ripple of less than one part per million. A neutron count histogram and Poisson count distribution are overlaid to provide a visual indication of the difference in correlation of natural and induced emitted neutrons from the radiation source to characterize the neutron source as fissile material or non-fissile material.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Review of Direct Neutron Conversion and Detection Processes

Commercial and laboratory neutron detection systems use indirect neutron response of materials like pressurized helium-3 (via nuclear reaction 3He(n, p)3H) to measure and count neutrons emanating from a source. Recently a host of semiconductors, especially a ternary semiconductor of lithium indium diselenide (6LiInSe2) and a quaternary alloy of enriched lithium-6, indium, phosphorous, and selenium (6LiInP2Se6), have shown promising neutron counting possibilities by directly converting neutrons into charge-carrying elements within the body of the semiconductor. These semiconductors have high thermal neutron capture cross sections, suitable energy bandgaps (~2.0 electron volts) for room-temperature operations, and a favorable electronic band structure for efficient electron charge transport. The article examines the semiconductor properties of these compounds in terms of their neutron counting capabilities and possible ways to extract neutron energy information from them. Lithium-6 and boron-10 (with thermal neutron absorption cross sections of 938 ± 6 and 3855 ± 26 barns, respectively) produce charged particles to be measured via indirect neutron interactions. The efficiency of indirect conversion neutron detectors is limited because of the inefficiencies in conversion mechanism. In case of direct conversion, the neutrons create charged particles in a single material for neutron capture and charge collection, increasing detection efficiency. Unlike 3He proportional counters, which provide no neutron energy information, the semiconductors can be used as neutron energy spectrometer. Fully resolved neutron energy by 6LiInP2Se6 from a plutonium-beryllium source has been reported in the literature. We will discuss the influence of these multilayered semiconductors’ crystallographic structures and growth techniques on neutron energy determination.

61 RADIATION PROTECTION AND DOSIMETRY↗

Powers of magnetic graph matrix: Fourier spectrum, walk compression, and applications

Magnetic graphs, originally developed to model quantum systems under magnetic fields, have recently emerged as a powerful framework for analyzing complex directed networks. Existing research has primarily used the spectral properties of the magnetic graph matrix to study global and stationary network features. However, their capacity to model local, nonequilibrium behaviors, often described by matrix powers, remains largely unexplored. We present a combinatorial interpretation of the magnetic graph matrix powers through directed walk profiles—counts of graph walks indexed by the number of edge reversals. Crucially, we establish that walk profiles correspond to a Fourier transform of magnetic matrix powers. The connection allows exact reconstruction of walk profiles from magnetic matrix powers at multiple discrete potentials, and more importantly, an even smaller number of potentials often suffices for accurate approximate reconstruction in real networks. This shows the empirical compressibility of the information captured by the magnetic matrix. This fresh perspective suggests further applications; for example, we illustrate how powers of the magnetic matrix can identify frustrated directed cycles (e.g., feedforward loops) and can be effectively employed for link prediction by encoding local structural details in directed graphs.

complex networks↗

Visualization of Tunable Weyl Line in A–A Stacking Kagome Magnets

Abstract Kagome magnets provide a fascinating platform for a plethora of topological quantum phenomena, in which the delicate interplay between frustrated crystal structure, magnetization, and spin–orbit coupling (SOC) can engender highly tunable topological states. Here, utilizing angle‐resolved photoemission spectroscopy, the Weyl lines are directly visualized with strong out‐of‐plane dispersion in the A–A stacked kagome magnet GdMn 6 Sn 6 . Remarkably, the Weyl lines exhibit a strong magnetization‐direction‐tunable SOC gap and binding energy tunability after substituting Gd with Tb and Li, respectively. These results not only illustrate the magnetization direction and valence counting as efficient tuning knobs for realizing and controlling distinct 3D topological phases, but also demonstrate AMn 6 Sn 6 (A = rare earth, or Li, Mg, or Ca) as a versatile material family for exploring diverse emergent topological quantum responses.

Cheng, Zi‐Jia↗

Atomic‐Resolution Imaging of Halide Perovskites Using Electron Microscopy

Abstract Atomic‐resolution imaging of halide perovskites (HPs) using transmission electron microscopy (TEM) is challenging because of the sensitivity of their structures to the electron beam. In this article, recent achievements in this area are reviewed, covering both all‐inorganic and organic–inorganic hybrid HPs, with an emphasis on the specific imaging conditions that have proven to be effective in avoiding electron beam‐induced structural damage. The discussion focusses on the total electron dose that HPs can bear before being damaged and the effects of different imaging modes, accelerating voltages, and temperatures. The crucial role of a direct‐detection electron‐counting camera in reducing the required electron dose is outlined, which is indispensable for imaging extremely sensitive organic–inorganic hybrid perovskites. In addition to reviewing published works, the results of initial attempts to perform atomic‐resolution elemental mapping for an all‐inorganic HP and image a hybrid HP using scanning TEM are introduced. The preparation of a TEM specimen from macroscopic crystals or devices of HPs, which is very important for practical applications but has not yet received attention, is also discussed. This article aims to provide guidance on the acquisition of atomic‐resolution TEM images of HPs and inspire the development of more imaging technologies for sensitive materials.

Song, Kepeng↗

An Analysis of Input Parameters for Film-Based Flash X-Ray Radiography

Flash X-ray radiography (flash) is a commonly used diagnostic technique in dynamic experiments. An analysis of the effects of input parameters on resulting metrics of image quality can aid the experimentalist in configuring the X-ray input parameters to produce the highest quality radiograph for a given experiment. Here, a flash X-ray test bed with HS800 film and a LANEX Medium F intensifier screen was used with an L3 450 kVp pulser and Scandiflash X-ray tube for this study. Input parameters including charge voltage, source filtering, and film-pack assembly were investigated for their impact on contrast-to-noise ratio (CNR), contrast, and contrast transfer function (CTF). Using VIDAR’s NDT Pro industrial film digitizer, scanner parameters such as optical density range, pixel spacing, scan mode, and digital bit-depth were also examined for their impact on image quality metrics. The highest CNR values were found with two LANEX intensifiers and no filtering. Charge voltage had no direct impact on CNR values. LANEX screen count and filtering resulted both in direct effects on CNR and interaction effects with each other and CNR value. Uncertainty bounds for CNR comparisons and repeatability of CTF evaluations are also discussed. Finally, the film results are compared with a previous study using other detector types, specifically Carestream INDUSTREX Flex GP, Flex HR, Flex XL Blue, and HPX-DR 3543.

dynamic radiography↗

The influence of environmental microseismicity on detection and interpretation of small-magnitude events in a polar glacier setting

Glacial environments exhibit temporally variable microseismicity. To investigate how microseismicity influences event detection, we implement two noise-adaptive digital power detectors to process seismic data from Taylor Glacier, Antarctica. We add scaled icequake waveforms to the original data stream, run detectors on the hybrid data stream to estimate reliable detection magnitudes and compare analytical magnitudes predicted from an ice crack source model. We find that detection capability is influenced by environmental microseismicity for seismic events with source size comparable to thermal penetration depths. When event counts and minimum detectable event sizes change in the same direction (i.e. increase in event counts and minimum detectable event size), we interpret measured seismicity changes as ‘true’ seismicity changes rather than as changes in detection. Generally, one detector (two degree of freedom (2dof)) outperforms the other: it identifies more events, a more prominent summertime diurnal signal and maintains a higher detection capability. We conclude that real physical processes are responsible for the summertime diurnal inter-detector difference. One detector (3dof) identifies this process as environmental microseismicity; the other detector (2dof) identifies it as elevated waveform activity. Our analysis provides an example for minimizing detection biases and estimating source sizes when interpreting temporal seismicity patterns to better infer glacial seismogenic processes.

54 ENVIRONMENTAL SCIENCES↗

Continuum radiated power density $(P^{\textrm{C}}_{\textrm{rad}})$ and effective charge $(Z_{\textrm{eff}})$ estimates from multi-energy photon-counting measurements

Multi-energy soft x-ray pinhole cameras have been designed, built, calibrated, and operated at Madison symmetric Torus, Alcator C-Mod, and more recently at Tokamak a configuration variable and Tungsten Environment in Steady-State Tokamak (WEST), to measure plasma emission across multiple energy ranges. Here we describe a new methodology to estimate the local continuum radiated power density and the plasma effective charge (Z eff ) directly from photon-counting measurements of the line-free continuum emission (Bremsstrahlung and Radiative Recombination) in several energy bands between 11 and 18 keV. This capability is particularly valuable for confinement systems using metal plasma-facing components, where x-ray losses from interactions with the sputtered wall can represent a significant fraction of the total radiated power (P rad ). The approach leverages a well-characterized detector responsivity, modeled by a complementary error function, and interprets the differential multi-energy measurements between adjacent energy levels through the probability density function of a Gaussian distribution. The implementation of this diagnostic technique is currently under development on the WEST tokamak, aiming at the goal of providing real-time P rad and Z eff measurements during long-pulse operation (up to 1000 s) in the 2026 campaign.

WEST↗

Electron image contrast analysis of mosaicity in rutile nanocrystals using direct electron detection

Direct electron detection provides high detective quantum efficiency, significantly improved point spread function and fast read-out which have revolutionized the field of cryogenic electron microscopy. However, these benefits for high-resolution electron microscopy (HREM) are much less exploited, especially for in situ study where major impacts on crystallographic structural studies could be made. By using direct detection in electron counting mode, rutile nanocrystals have been imaged at high temperature inside an environmental transmission electron microscope. The improvements in image contrast are quantified by comparison with a charge-coupled device (CCD) camera and by image matching with simulations using an automated approach based on template matching. Together, these approaches enable a direct measurement of 3D shape and mosaicity (~1°) of a vacuum-reduced TiO 2 nanocrystal about 50 nm in size. Thus, this work demonstrates the possibility of quantitative HREM image analysis based on direct electron detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection and quantification of γ-H2AX using a dissociation enhanced lanthanide fluorescence immunoassay

Phosphorylation of the histone protein H2AX to form γ-H2AX foci directly represents DNA double-strand break formation. Traditional γ-H2AX detection involves counting individual foci within individual nuclei. The novelty of this work is the application of a time-resolved fluorescence assay using dissociation-enhanced lanthanide fluorescence immunoassay for quantitative measurements of γ-H2AX. For comparison, standard fluorescence detection was employed and analyzed either by bulk fluorescent measurements or by direct foci counting using BioTek Spot Count algorithm and Gen 5 software. Etoposide induced DNA damage in A549 carcinoma cells was compared across all test platforms. Time resolved fluorescence detection of europium as a chelated complex enabled quantitative measurement of γ-H2AX foci with nanomolar resolution. Comparative bulk fluorescent signals achieved only micromolar sensitivity. Lanthanide based immunodetection of γ-H2AX offers superior detection and a user-friendly workflow. These approaches have the potential to improve screening of compounds that either enhance DNA damage or protect against its deleterious effects.

59 BASIC BIOLOGICAL SCIENCES↗

Attributes of Bi-Directional Turbomachinery for Pumped Thermal Energy Storage

Abstract In this paper, we (i) present a methodology for determining the aerodynamic performance of bi-directional turbomachines for pumped thermal energy storage, i.e., turbomachines designed to operate as a compressor in one direction, and then as a turbine in the opposite direction, (ii) carry out performance computations for such turbomachines, and (iii) propose principles for conceptual design of these devices. Focus is placed on using the energy storage cycle not only to identify the novel requirements placed on bi-directional turbomachines but also to estimate the effect of these requirements on the efficiency of the energy storage process. In particular, the difference between aerodynamic loading in forward and in backward operation causes the blading to work at incidences leading to the performance below maximum efficiency, resulting in a lower round-trip efficiency. The description of the design principles includes determination of the number of stages, definition of nondimensional parameters for blading selection, and optimization of two-dimensional blading for bi-directional operation. The assessment of stage count shows the relationship between relative Mach number, pressure ratio, and round-trip efficiency. The nondimensional parameters are assessed through a bi-directional analogue to existing “Smith charts,” for the efficiency of single-direction turbomachines, as a function of camber and stagger. The blade shape evaluation and optimization show how the blade profile can be modified to address the requirements of a bi-directional turbomachine, enabling an increase in round-trip efficiency of two percentage points compared to a baseline double circular arc configuration.

Engineering↗

Experimental demonstration and modeling of a robotic neutron detector with spectral and directional sensitivity for treaty verification

International safeguards and arms control agreements often require labor-intensive, intrusive onsite inspections to perform verification tasks. The ability to localize a neutron source and/or characterize a neutron field may be imperative for identifying anomalies. We are interested in the role of autonomous mobile robots, which, if designed properly, may be more effective and efficient and less intrusive than their human counterparts. Toward developing such a capability, we, for this study, have constructed the N-SpecDir Bot, comprised of three boron-coated straw detectors azimuthally-distributed within a cylinder of high-density polyethylene, which is mounted on an omni-directional robotic platform. Our N-SpecDir Bot is specifically designed to provide spectral and directional sensitivity, in addition to gross counts, by utilizing the signals from the three detectors. The detection system has been extensively characterized by MCNP modeling, which has been benchmarked to experiments conducted at the Princeton Plasma Physics Laboratory. We demonstrate the spectral and directional sensitivity experimentally and in simulation, and provide a simple yet robust method for directional measurements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Autonomous Polycrystalline Material Decomposition For Hyperspectral Neutron Tomography

Hyperspectral neutron tomography is an effective method for analyzing crystalline material samples with complex compositions in a non-destructive manner. Since the counts in the hyperspectral neutron radiographs directly depend on the neutron cross-sections, materials may exhibit contrasting neutron responses across wavelengths. Therefore, it is possible to extract the unique signatures associated with each material and use them to separate the crystalline phases simultaneously.We introduce an autonomous material decomposition (AMD) algorithm to automatically characterize and localize polycrystalline structures using Bragg edges with contrasting neutron responses from hyperspectral data. The algorithm estimates the linear attenuation coefficient spectra from the measured radiographs and then uses these spectra to perform polycrystalline material decomposition and reconstructs 3D material volumes to localize materials in the spatial domain. Our results demonstrate that the method can accurately estimate both the linear attenuation coefficient spectra and associated reconstructions on both simulated and experimental neutron data.

Samin nur chowdhury, Mohammad↗

Filtration Performance Results: Sierra Peaks Material No. 4

Sandia National Laboratories (SNL) assessed the filtration performance of materials from Sierra Peaks to identify alternatives which may perform similarly to materials used in FDA-approved N95 respirators. This work is meant to characterize the aerosol performance of materials to give Sierra Peaks information for them to determine if they elect to submit masks made using these materials for follow-on N95 certification testing at an accredited facility. The R&D testbed used is a large-scale filtration system designed to test commercial filter boxes. System modifications were performed to simulate, where possible, parameters defined by the National Institute for Occupational Safety and Health (NIOSH) for certification of filter materials for N95 respirators (NIOSH 2019). The system is a pull-through design. Air enters through a Laminar Flow Element (LFE) and the volumetric flow is measured based on the pressure drop across the LFE. Pressure is measured via a Pressure Transducer (PT). The air then passes through a High Efficiency Particulate Air (HEPA) filter to purge the air of ambient airborne particulates. Test aerosol is injected into the flow shortly after and mixing is induced via a coarse mesh. The airflow is allowed to fully develop prior to arriving at the test section. The aerosol then passes through the test material mounted in a box in the test section. Pressure drop across the test article is measured and aerosol sampling probes measure the aerosol concentrations upstream and downstream of the sample. The air passes through a second HEPA filter prior to being exhausted to ambient by a blower. A Topas aerosol generator is used to produce the test aerosol from Sodium Chloride (NaC1) dissolved in deionized (DI) water. Generated aerosol passes through a heated mixing chamber and a desiccant dryer to produce nanosized solid-state particulates. A dilution loop allows for the aerosol concentration to be regulated. The aerosol sampling probes upstream and downstream of the test section are aligned with the flow path. These are ducted directly to the aerosol sizing and counting instruments. A Laser Aerosol Spectrometer (LAS) was used for data collection in the original configuration of the system and was also used for initial testing in this project. Because the lower measurement range for the LAS is 90 nanometers (nm), the LAS was switched out for a more complicated Scanning Mobility Particle Sizer (SMPS) spectrometer system. The SMPS is comprised of an Electrostatic Classifier (EC), Differential Mobility Analyzer (DMA), and a Condensation Particle Counter (CPC). This enabled data collection at 75 nm, the particle size called out in the NIOSH guidelines.

36 MATERIALS SCIENCE↗

Fast event-based electron counting for small-molecule structure determination by MicroED

Electron counting helped realize the resolution revolution in single-particle cryoEM and is now accelerating the determination of MicroED structures. Its advantages are best demonstrated by new direct electron detectors capable of fast (kilohertz) event-based electron counting (EBEC). This strategy minimizes the inaccuracies introduced by coincidence loss (CL) and promises rapid determination of accurate structures. We used the Direct Electron Apollo camera to leverage EBEC technology for MicroED data collection. Given its ability to count single electrons, the Apollo collects high-quality MicroED data from organic small-molecule crystals illuminated with incident electron beam flux densities as low as 0.01–0.045 e − /Å 2 /s. Under even the lowest flux density (0.01 e − /Å 2 /s) condition, fast EBEC data produced ab initio structures of a salen ligand (268 Da) and biotin (244 Da). Each structure was determined from a 100° wedge of data collected from a single crystal in as few as 50 s, with a delivered fluence of only ∼0.5 e − /Å 2 . Fast EBEC data collected with a fluence of 2.25 or 3.33 e − /Å 2 also facilitated a 1.5 Å structure of thiostrepton (1665 Da). While refinement of these structures appeared unaffected by CL, a CL adjustment applied to EBEC data further improved the distribution of intensities measured from the salen ligand and biotin crystals. However, CL adjustment only marginally improved the refinement of their corresponding structures, signaling the already high counting accuracy of detectors with counting rates in the kilohertz range. Overall, by delivering low-dose structure-worthy data, fast EBEC collection strategies open new possibilities for high-throughput MicroED.

EBEC↗

Machine learning pipeline for denoising low signal-to-noise ratio and out-of-distribution transmission electron microscopy datasets

High-resolution transmission electron microscopy (HRTEM) is crucial for observing material’s structural and morphological evolution at Angstrom scales, but the electron beam can alter these processes. Devices such as CMOS-based direct-electron detectors operating in electron-counting mode can be utilized to substantially reduce the electron dosage. However, the resulting images often lead to a low signal-to-noise ratio, which requires frame integration that sacrifices temporal resolution. Several machine learning (ML) models have been recently developed to successfully denoise HRTEM images. Yet, these models are often computationally expensive, and their inference speeds on GPUs are outpaced by the imaging speed of advanced detectors, precluding in situ analysis. Furthermore, the performance of these denoising models on datasets with imaging conditions that deviate from the training datasets has not been evaluated. To mitigate these gaps, we propose a new self-supervised ML denoising pipeline specifically designed for time-series HRTEM images. This pipeline integrates a blind-spot convolution neural network with pre-processing and post-processing steps, including drift correction and low-pass filtering. Results demonstrate that our model outperforms various other ML and non-ML denoising methods in noise reduction and contrast enhancement, leading to improved visual clarity of atomic features. Additionally, the model is drastically faster than U-Net-based ML models and demonstrates excellent out-of-distribution generalization. The model’s computational inference speed is in the order of milliseconds per image, rendering it suitable for application in in-situ HRTEM experiments.

36 MATERIALS SCIENCE↗