Search NASA⌕ Search

SEARCH · Search NASA

Results for “drum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Materials Identification System for 200 liter/55 gallon Waste Drums using Computer Tomographic Techniques - 17162

In 2014 a thermal runaway event within a drum in-situ at the Waste Isolation Pilot Plant (WIPP) facility near Carlsbad, NM, resulted in the drum being breached and activity released. This emphasized the need for a better determination of drum contents and identification of material combinations and in-drum conditions. Enhanced characterization is required to identify and quantify the presence of absorbent materials, determine whether they are organic or inorganic, locate their position in the drum with respect to other materials, and quantify how much liquid is being held in the absorbent material. As part of the waste characterization process to ensure compliance with the WIPP waste acceptance criteria, drums are currently inspected by Real Time Radioscopic (RTR) x-ray to identify prohibited items such as free liquids and un-punctured aerosol cans, but that technique cannot satisfy these newly identified requirements, and a new approach to non-destructive examination was required. This approach complements the current RTR inspection with Cone-Beam Area Detector Computed Tomography (CT) scanning of the whole drum, followed by more-quantitative CT scanning of specific areas of concern, using a highly collimated Linear Detector Array. The density of representative waste drums required x-ray energies of up to 9 MeV, which meant that sorting of materials by their photo-electric absorption is not viable as this occurs in the 80 - 180 keV range. However, a notable characteristic of higher energy imaging in this context is the general correspondence between material density and total attenuation in the 1.5-4.0 MeV range due to Compton Scatter. Development of the imaging chain, comprising the x-ray source and the detectors was critical to achieving the required system performance. Theoretical analysis of the energy spectra of the 9 MeV beam, and filtration of the beam to remove the lower energies which cause beam hardening artifacts in the image was required. Theoretical evaluation of the required efficiency and image acquisition performance of area detectors and linear array detectors, was carried out to complete the selection of equipment. A system of density calibration rods was designed and, together with the selected equipment, was configured and used to acquire cone-beam CT data and line-scan CT data by scanning a 55 gallon drum containing surrogate waste. From the acquired data, CT reconstruction was performed and the basis of algorithms to identify materials were developed. Following this, a series of blind tests were done using a range of surrogate materials the contents of which were unknown to the system operators. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Viability of In-Drum Treatment for Transuranic Wastes Containing Nitrates and Organics - 20406

In February of 2014, a breach in a waste drum stored at the Waste Isolation Pilot Plant resulted in the release of radioactive material into the immediate surroundings and outside of the plant. The waste drum contained a mixture of an organic absorbent and nitrate salts that pressurized the drum, eventually causing the drum lid to fail, leading to the adverse event. Other waste drums with similar contents exist posing both storage and treatment risks. These drums may successfully be treated by an in-drum treatment system. This paper considers the design and operation of an in-drum treatment system and the characteristics of waste containing organics and nitrates to evaluate the viability of treatment. A description of the system, how it is operated, and a summary of previous testing performed is provided. Treatment of both liquids and absorbed liquids comprised of organics and nitrates is addressed. Viability of treatment is demonstrated by presenting operational methods and design strategies to ensure successful treatment of the waste drums. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FAILURE ANALYSIS: WASTEWATER DRUM BULGING

A 55 gallon wastewater drum lid was found to be bulged during storage in a remote area. Drum samples were obtained for analysis. The interior surface of these samples revealed blistering and holes in the epoxy phenolic drum liner and corrosion of the carbon steel drum. It is suspected that osmotic pressure drove permeation of the water through the epoxy phenolic coating which was weakened from exposure to low pH water. The coating failed at locations throughout the drum interior. Subsequent corrosion of the carbon steel released hydrogen which pressurized the drum causing deformation of the drum lid. Additional samples from other wastewater drums on the same pallet were also evaluated and limited corrosion was visible on the interior surfaces. It is suspected that, with time, the corrosion would have advanced to cause pressurization of these sealed drums.

08 HYDROGEN↗

Recommendations for DOT 7A Type A Drum Closure and Drop Testing with Additional 49 CFR 173.465(c)(2) Testing and Analysis

The Savannah River National Laboratory (SRNL) is in the process of developing recommendation for the U S. Department of Energy contractors and vendors who want to qualify drums as U S. Department of Transportation (DOT) 7A Type A to meet 49 CFR 173.465 drop testing requirements for fissile and non-ftssile material to maintain containment. Based on the finite element analysis (FEA) models, the safety features suffering the maximum damage that result in loss of containment are identified as the closure ring mechanism (in entirety), the top (mouth area) of the drum, and the lid (including the gasket). The maximum damage is measured in terms of the collective ability of these combined three safety features to maintain containment. As such, both drop testing and FEA were performed to determine the sensitivities of these safety features to drop variations. As part of this effort, a series of physical drop tests and FEAs were conducted at SRNL. These tests used Skolnik drums, CQ5508L (see Attachment 1), which are open DOT 7A Type A open- head carbon steel 208-liter (55-gallon) drums with 12-gauge bolted closure rings. Variables studied were (1) stress relief methods during closure ring installation, (2) content configurations, and (3) drum orientations during a 4-foot free fall. It should be noted that the Skolnik CQ5508L drums have a closure ring with a "V shaped" cross section. (1) The closure testing with analysis confirmed that closure stress relief by rapping is necessary to distribute the closure ring tension around the perimeter and to maintain sufficient closure pre-load for lid retention during 4-foot drops of the heavier packages (500 to 1,000 lbs). It was concluded that no specific style of stress relief is preferred (e g., multi-step rapping/torqueing process, heavy hits vs. light hits, hitting near closure vs. away), as long as no additional change in bolt torque occurs with additional rapping. (2) (3) Modeling indicated that maximum damage is a result of both: (2) content configuration and (3) drop orientation. The worst-case content configuration is one with an eccentrically loaded concentrated content mass. FEA modeling showed that the center- of-gravity over top (CGoT) with the eccentric content on the high side was the orientation of maximum damage relative to drum lid retention. In this content configuration (i.e., CGoT), FEA modeling showed payloads over 500 lbs were required to contain a load distribution plate between content and lid. Both analysis and testing showed the drum with distribution plate can pass the 4-foot CGoT drop.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Image data rate converter having a drum with a fixed head and a rotatable head

A data-rate converter is disclosed comprising a rotatable data-storing drum with at least one fixed read/record head and a rotatable read/record head. The latter is rotatable in a circular path about the drum axis of rotation. The drum is positionable in any one of a plurality of axial positions with respect to the heads, so that at least one drum track is aligned with the fixed head in one drum position and with the rotatable head in another drum position. When a track is aligned with the fixed head, data may be recorded therin or read out therefrom at a rate which is a function of drum rotation, while when aligned with the rotatable head, data may be recorded or read out at a rate which is a function of the rates and directions of rotation of both the drum and the head.

Billingsley, F. C.↗

Thermal sensing for characterizing the contents of waste storage drums

The present investigation is concerned with the feasibility to employ remote sensing for the characterization of the contents of liquid chemical waste storage drums. Philipson et al. (1981) had found that, when the air temperature is changing rapidly, differences in the thermal inertia of the drum contents can lead to detectable differences in the skin temperature of the drums. Thus, postsunset, airborne thermal remote sensing could potentially provide some level of discrimination among chemical storage drums. Discrimination should be possible among steel drums filled largely with: (1) aqueous solvents, (2) organic solvents, or (3) clay packing materials. The response of a drum filled with clay packing materials should be similar to that of an empty drum. The reported study had the objective to verify the theoretical findings, taking into account the use of a hand-held infrared radiometer. It was found that under the proper conditions the temperature differences among drums with the three different types of contents will be significant and consistent.

Philpot, W. D.↗

Drum plug piercing and sampling device and method

An apparatus and method for piercing a drum plug of a drum in order to sample and/or vent gases that may accumulate in a space of the drum is provided. The drum is not damaged and can be reused since the pierced drum plug can be subsequently replaced. The apparatus includes a frame that is configured for engagement with the drum. A cylinder actuated by a fluid is mounted to the frame. A piercer is placed into communication with the cylinder so that actuation of the cylinder causes the piercer to move in a linear direction so that the piercer may puncture the drum plug of the drum.

47 OTHER INSTRUMENTATION↗

Impact of Different Standard Type A7A Drum Closure-Ring Practices on Gasket Contraction and Bolt Closure Distance– 15621

The Department of Energy, the Savannah River National Laboratory, several manufacturers of specification drums, and the United States Department of Transportation (DOT) are collaborating in the development of a guidance document for DOE contractors and vendors who wish to qualify containers to DOT 7A Type A requirements. Currently, the effort is focused on DOT 7A Type A 208-liter (55-gallons) drums with a standard 12-gauge bolted closure ring. The U.S. requirements, contained in Title 49, Part 178.350 “Specification 7A; general packaging, Type A specifies a competent authority review of the packaging is not required for the transport of (Class 7) radioactive material containing less than Type A quantities of radioactive material. For Type AF drums, a 4 ft. regulatory free drop must be performed, such that the drum “suffers maximum damage.” Although the actual orientation is not defined by the specification, recent studies suggest that maximum damage would result from a shallow angle top impact, where kinetic energy is transferred to the lid, ultimately causing heavy damage to the lid, or even worse, causing the lid to come off. Since each vendor develops closure recommendations/procedures for the drums they manufacture, key parameters applied to drums during closing vary based on vendor. As part of the initial phase of the collaboration, the impact of the closure variants on the ability of the drum to suffer maximum damage is investigated. Specifically, closure testing is performed varying: 1) the amount of torque applied to the closure ring bolt; and, 2) stress relief protocol, including: a) weight of hammer; and, b) orientation that the hammer hits the closure ring. After closure, the amount of drum lid gasket contraction and the distance that the closure bolt moves through the closure ring is measured.

42 ENGINEERING↗

Impact of different standard type A7A drum closure-ring practices on gasket contraction and bolt closure distance - 15621

The Department of Energy, the Savannah River National Laboratory, several manufacturers of specification drums, and the United States Department of Transportation (DOT) are collaborating in the development of a guidance document for DOE contractors and vendors who wish to qualify containers to DOT 7A Type A requirements. Currently, the effort is focused on DOT 7A Type A 208-liter (55-gallons) drums with a standard 12-gauge bolted closure ring. The U.S. requirements, contained in Title 49, Part 178.350 'Specification 7A; general packaging, Type A specifies a competent authority review of the packaging is not required for the transport of (Class 7) radioactive material containing less than Type A quantities of radioactive material. For Type AF drums, a 4 ft. regulatory free drop must be performed, such that the drum 'suffers maximum damage.' Although the actual orientation is not defined by the specification, recent studies suggest that maximum damage would result from a shallow angle top impact, where kinetic energy is transferred to the lid, ultimately causing heavy damage to the lid, or even worse, causing the lid to come off. Since each vendor develops closure recommendations/procedures for the drums they manufacture, key parameters applied to drums during closing vary based on vendor. As part of the initial phase of the collaboration, the impact of the closure variants on the ability of the drum to suffer maximum damage is investigated. Specifically, closure testing is performed varying: 1) the amount of torque applied to the closure ring bolt; and, 2) stress relief protocol, including: a) weight of hammer; and, b) orientation that the hammer hits the closure ring. After closure, the amount of drum lid gasket contraction and the distance that the closure bolt moves through the closure ring is measured. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Keep It Smart and Simple - Henriette - The Advanced Designed Drum Gripper for Remote Handling Tasks - 19327

A power manipulator has many applications in the handling, treatment and packaging of radioactive waste. In high radiation environments, where humans cannot work safely, a power manipulator is essential to perform difficult and heavy tasks. For more than 40 years, Waelischmiller has provided power manipulators to the nuclear market. Specifically in a high radiation nuclear environment, electrical driven manipulators are preferred. The basic design of a power manipulator is divided into the following parts: Bridge, carriage, telescopic mast and manipulator arm. All parts are customizable in length, width and capacity. The standard power manipulator version is equipped with a manipulator arm. For the nuclear waste disposal industry, there is a special need for a drum gripper. Drums are used for packing low, medium or high activated material and for storage. After packing, the drums must be handled remotely. For both tasks, a power manipulator with a drum gripper is needed. For this project KTE (Kerntechnische Entsorgung Karlsruhe GmbH) required a total refurbishment of equipment in a cell used for handling, sorting and packaging radioactive waste drums. The power manipulator was obsolete and provided low availability and through put. This cell was an essential asset in their decommissioning process and was impacting KTE's ability to meet their volume objectives. Our challenge was to develop a new system with few details from the original cell construction. The new manipulator must meet all capabilities of the old system and in addition have the ability to achieve 180 degree tilting of the drums. An additional challenge was the requirement to use the existing rails in the cell which were very close to the roof structure which required a special design. Our project, named internally Henriette, is the first of its kind. The drum gripper is based on the power manipulator A1000 series. The biggest challenges in this project were to adapt the standard components of the power manipulator to the non-standard type of gripper to have 180 deg. tilting of the drum and a handling capacity of 1200 kg in the whole working range. The new manipulator fits to the old rails and is mountable in a hot cell with restricted access and can operate with the other A1000 manipulator which is located in the cell. The result is a system with no external wiring, maintenance-free and easy to decontaminate. Other features include a 5 t auxiliary hoist on additional and parallel carriages, emergency drives for bridge and carriage, emergency drive for telescope turn movement and emergency lifting unit for telescope. A tilt and pan holder for camera on the telescope and external mechanical emergency drives on the gripper were also essential. This paper will address the complexity, challenges and engineering ingenuity required to replace very old and obsolete equipment with a state-of-the-art system within very limited physical space and within a high radiation environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Investigation of Plume Response to Soil Vapor Extraction and Hypothetical Drum Failure

Core Ideas Soil vapor extraction (SVE) wells are an effective interim remediation technique. Flow and transport modeling assists in evaluation of vapor plume behavior. Plume simulations assuming drum failure and SVE provide a framework for remediation planning. A small borehole subset could be monitored for detection of VOC releases due to drum failure. Soil vapor extraction (SVE) has been used at sites across the Department of Energy complex, including sites where legacy subsurface wastes represent a potential source of groundwater contamination. At Los Alamos National Laboratory (LANL), leakage from waste drums buried at an inactive chemical waste site has created a subsurface vapor plume of volatile organic compounds (VOCs). Soil vapor extraction operation in 2015 and rebound testing through 2017 were successful in reducing the plume's mass and mitigating VOC migration toward the water table. However, the possibility that waste drums could fail and release VOCs could pose a challenge in the future. To explore the impacts of drum failure, as well as the capabilities of SVE remediation, we simulated hypothetical contaminant release scenarios and subsequent SVE remediation. Three‐dimensional subsurface VOC behavior, including advection, diffusion, and plume interactions with topography, were simulated using the porous flow simulator Finite Element Heat and Mass Transfer. Simulations of future site conditions have allowed identification of “sentry” boreholes that can be monitored for early detection in case of drum failure. Sentry boreholes can also be used to set concentration thresholds above which SVE should be initiated. For the LANL site, simulations show that SVE can be started 3 yr following drum failure and remain a viable remediation tool. More broadly, the principles outlined in this work can be used to support remediation planning at other subsurface waste sites. Predictive models of future releases can be analyzed to set concentration threshold values, guide selection of sentry boreholes, and increase operational efficiency.

54 ENVIRONMENTAL SCIENCES↗

Results for the Independent Sampling and Analysis of Used Oil Drums at the Impact Services Facility in Oak Ridge, Tennessee

The U.S. Department of Energy (DOE) requested that Oak Ridge Associated Universities (ORAU), via the Oak Ridge Institute for Science and Education (ORISE) contract, perform independent sampling and analysis of used oils contained within eight 55 gallon drums stored at the former IMPACT Services facility, located at the East Tennessee Technology Park in Oak Ridge, Tennessee. These drums were originally delivered by LATA Sharp Remediation Services (LSRS) to IMPACT Services on January 11, 2011 as part of the Bldg. K-33 demolition project, and the drums plus contents should have been processed as non-hazardous non-radiological waste by IMPACT Services. LSRS received a certificate of destruction on August 29, 2012 (LSRS 2012a). However, IMPACT Services declared bankruptcy and abandoned the site later in 2012, and eight of the original eleven K-33 drums are currently stored at the facility. The content of these drums is the subject of this investigation. The original drum contents were sampled by LSRS in 2010 and analyzed for gross alpha, gross beta, and polychlorinated biphenyls (PCBs), using both compositing and grab sampling techniques. The objective of this 2013 sample and analysis effort was to duplicate, to the extent possible, the 2010 sampling and analysis event to support final disposition decisions. Part of that decision process includes either verifying or refuting the assertion that oils that are currently stored in drums at the IMPACT Services facility originated from Bldg. K-33 equipment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal evaluations for mixed organic and nitrate salt drums in interim storage at the WCS Federal Waste Facility

Waste Control Specialists LLC (WCS) operates the Federal Waste Facility (FWF) in Texas that is licensed to process and store certain types of mixed low-level radioactive waste packages. The specific waste currently housed at WCS includes some of the transuranic (TRU) waste that originated at the DOE Los Alamos National Laboratory (LANL) and are destined for disposal at the DOE Waste Isolation Pilot Plant (WIPP) facility. The TRU waste within each Standard Waste Box (SWB) was packaged in 55-gallon drums at LANL. Some of the drums contain mixed organic and nitrate salt contents suspected of experiencing a chemical reaction. The drums (up to four drums in a SWB) were then overpacked in a SWB prior to shipment to WCS. In the most common configuration, WCS placed the SWB containing the drums on metal pallets and stored two SWBs into Modular Concrete Canisters (MCCs) in a double stacked array. The MCCs were placed in a staggered array at a segregated area of the FWF and covered with sand to mitigate the heating that occurred when stored above ground on waste pads. The temporary interment is also intended to provide additional containment of the suspect reactive waste to mitigate release of radioactivity in an incident such as that which occurred at WIPP for one such drum. Void space of each MCC was filled with 1-inch pea gravel to facilitate retrievability. Thermocouple probes were placed within each MCC to monitor heat generation from the SWBs and the MCC lids were closed. The primary objective of this analysis was to estimate the heat generation of the SWB drum contents when the SWB package temperature inside the MCC and the FWF ambient temperature were monitored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Miniature rotating transmissive optical drum scanner

A miniature rotating transmissive optical scanner system employs a drum of small size having an interior defined by a circumferential wall rotatable on a drum axis, an optical element positioned within the interior of the drum, and a light-transmissive lens aperture provided at an angular position in the circumferential wall of the drum for scanning a light beam to or from the optical element in the drum along a beam azimuth angle as the drum is rotated. The miniature optical drum scanner configuration obtains a wide scanning field-of-view (FOV) and large effective aperture is achieved within a physically small size.

Lewis, Robert↗

Experimental Measurements of Clothes Dryer Drum Heat and Mass Transfer Effectiveness

Accurate system modeling of a clothes dryer requires a drum component model that displays correct trends with respect to changing conditions. In this work, a model of drum heat and mass transfer effectiveness is adopted. Within this framework, experimental measurements of drum effectiveness are investigated with respect to several variables: drum volume, load mass, cloth type, drum volumetric air flow rate, and drum entering air temperature. These data can inform the modeling and simulation of any clothes dryer with horizontal-axis, axial-flow tumble-type clothes dryer drum.

Gluesenkamp, Kyle R.↗

Fifty-Five Gallon Drum Standard Study

Fifty-five gallon drums are routinely used within the U.S. for the storage and eventual disposal of fissionable materials as Transuranic or low-level waste. To support these operations, criticality safety evaluations are required. A questionnaire was developed and sent to selected Endusers at Hanford, Idaho National Laboratory, Lawrence Livermore National Laboratory, Oak Ridge and the Savannah River Site to solicit current practices. This questionnaire was used to gather information on the kinds of fissionable materials packaged into drums, the models used in performing criticality safety evaluations in support of operations involving these drums, and the limits and controls established for the handling and storage of these drums. The completed questionnaires were reviewed and clarifications solicited through individual communications with each Enduser to obtain more complete and consistent responses. All five sites have similar drum operations involving thousands to tens of thousands of fissionable material waste drums. The primary sources for these drums are legacy (prior operations) and decontamination and decommissioning wastes at all sites except Lawrence Livermore National Laboratory. The results from this survey and our review are discussed in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quality quandaries: Statistical detective work to understand the isotopic ratios in Drum 68660 and the radioactive release at WIPP

An incident at the Department of Energy's Waste Isolation Pilot Plant (WIPP) in 2014 resulted in the release of radioactive material into the environment. Initially, it was known that at least one drum in WIPP, identified as drum 68660, was involved. However, questions remained. Could the air-monitor isotopic ratios measured in WIPP at the time of the release be explained by materials in drum 68660 or were other drums involved? Could internal conditions in drum 68660 have caused the breach? What were the implications for 68660's sister drum? These questions needed to be answered as quickly as possible. Here, this analysis, which was completed in three weeks, combined combinatorics and uncertainty analysis to provide scientists with the timely evidence they needed to either answer these important questions or to design experiments to answer them.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

HYDROGEN GENERATION FROM SLUDGE SAMPLE BOTTLES CAUSED BY RADIOLYSIS AND CHEMISTRY WITH CONCETNRATION DETERMINATION IN A STANDARD WASTE BOX (SWB) OR DRUM FOR TRANSPORT

A volume of 600 mL of sludge, in 4.1 L sample bottles (Appendix 7.6), will be placed in either a Super Pig (Ref. 1) or Piglet (Ref. 2, 3) based on shielding requirements (Ref. 4). Two Super Pigs will be placed in a Standard Waste Box (SWB, Ref. 5), as their weight exceeds the capacity of a drum; two Piglets will be placed in a 55-gallon drum (shown in Appendix 7.2). The generation of hydrogen gas through oxidation/corrosion of uranium metal by its reaction with water will be determined and combined with the hydrogen produced by radiolysis. The hydrogen concentration in the 55-gallon drum and SWB will be calculated to show that the lower flammability limit of 5% hydrogen is not reached. The inner layers (i.e., sample bottle, bag and shielded pig) in the SWB and drum will be evaluated to assure no pressurization occurs as the hydrogen vents from the inner containers (e.g., shielded pigs, etc.). The reaction of uranium metal with anoxic liquid water is highly exothermic; the heat of reaction will be combined with the source term decay heat, calculated from Radcalc, to show that the drum and SWB package heat load limits are satisfied. This analysis does five things: (1) Estimates the H{sub 2} generation from the reaction of uranium metal with water; (2) Estimates the H{sub 2} generation from radiolysis (using Radcalc 4.1); (3) Combines both H{sub 2} generation amounts, from Items 1 and 2, and determines the percent concentration of H{sub 2} in the interior of an SWB with two Super Pigs, and the interior of a 55-gallon drum with two Piglets; (4) From the combined gas generation rate, shows that the pressure at internal layers is minimal; and (5) Calculates the maximum thermal load of the package, both from radioactive decay of the source and daughter products as calculated/reported by Radcalc 4.1, and from the exothermic reaction of uranium metal with water.

08 HYDROGEN↗