Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic cavity method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Quantum dynamics of cavity-assisted photoassociation of Bose-Einstein-condensed atoms

We explore the quantum dynamics of photoassociation of Bose-Einstein condensed atoms into molecules using an optical cavity field. Inside of an optical resonator, photoassociation of quantum degenerate atoms involves the interaction of three coupled quantum fields for the atoms, molecules, and the photons. The feedback created by a high-Q optical cavity causes the cavity field to become a dynamical quantity whose behavior is linked in a nonlinear manner to the atoms inside and where vacuum fluctuations have a more important role than in free space. We develop and compare several methods for calculating the dynamics of the atom-molecule conversion process with a coherently driven cavity field. We first present an alternate operator representation for the Hamiltonian from which we derive an improved form of mean field theory and an approximate solution of the Heisenberg-Langevin (HL) equations that properly accounts for quantum noise in the cavity field. It is shown that our improved mean field theory corrects several deficiencies in traditional mean field theory based on expectation values of annihilation and creation operators. Also, we show by direct comparison to numerical solutions of the density matrix equations that our approximate quantum solution of HL equations gives an accurate description of weakly or undriven cavities where mean field theories break down.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spatio-temporal dynamics of a dual-wavelength vertical-external-cavity surface-emitting semiconductor laser

A mathematical model of a dual-wavelength vertical-external-cavity surface-emitting laser (VECSEL) is formulated with the distribution of optical pumping and generated fields over the beam cross sections taken into account. Dynamic regimes are mapped using the 'pump power - cavity round-trip time' plane. The map comprises regions of cw generation, periodic oscillation, quasiperiodic and chaotic oscillations of the radiation intensity and the carrier density in the active regions of the laser. It is shown that when the reflection coefficient of the external cavity is increased, the regions of complex dynamics in the maps become narrower. Using numerical methods the spatio-temporal dynamics of a dualwavelength VECSEL is analysed in the regime of quasi-periodic oscillations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of the measured and predicted response of the Earth Radiation Budget Experiment active cavity radiometer during solar observations

The Earth Radiation Budget Experiment consists of an array of radiometric instruments placed in earth orbit by the National Aeronautics and Space Administration to monitor the longwave and visible components of the earth's radiation budget. Presented is a dynamic electrothermal model of the active cavity radiometer used to measure the earth's total radiative exitance. Radiative exchange is modeled using the Monte Carlo method and transient conduction is treated using the finite element method. Also included is the feedback circuit which controls electrical substitution heating of the cavity. The model is shown to accurately predict the dynamic response of the instrument during solar calibration.

Mahan, J. R.↗

Reconciling Work Functions and Adsorption Enthalpies for Implicit Solvent Models: A Pt (111)/Water Interface Case Study

Implicit solvent models are a computationally efficient method of representing solid/liquid interfaces prevalent in electrocatalysis, energy storage, and materials science. However, electronic structure changes induced at the metallic surface by the dielectric continuum are not fully understood. To address this, we perform DFT calculations for the Pt(111)/water interface, in order to compare Poisson–Boltzmann continuum solvation methods with ab initio molecular dynamics (AIMD) simulations of explicit solvent. We show that the implicit solvent cavity can be parametrized in terms of the electric dipole moment change at the equilibrated explicit Pt/water interface to obtain the potential of zero charge (PZC). We also compare the accuracy of aqueous enthalpies of adsorption of phenol on Pt(111) using geometry and charge density based dielectric cavitation methods. The ability to parametrize the cavity according to individual atoms, as afforded in the geometry based approach, is key to obtaining accurate enthalpy changes of adsorption under aqueous conditions. Additionally, we show that the electronic structure changes induced by explicit solvent and our proposed implicit solvent parametrization scheme yield comparable density difference profiles and d-band projected density of states. We therefore demonstrate the capability of implicit solvent approaches to capture both the energetics of adsorption processes and the main electronic effects of aqueous solvent on the metallic surface. Therefore, this work provides a scheme for computationally efficient simulations of interfacial processes for applications in areas such as heterogeneous catalysis and electrochemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Feedback Control of Flow Induced Cavity Tones

An experimental study of the application of discrete-time, linear quadratic control design methods to the cavity tone problem is described. State space models of the dynamics from a synthetic jet actuator at the leading edge of the cavity to two pressure sensors in the cavity were computed from experimental data. Variations in model order, control order, control bandwidth, and properties of a Kalman state estimator were studied. Feedback control reduced the levels of multiple cavity tones at Mach 0.275, 0.35, and 0.45. Closed loop performance was often limited by excitation of sidebands of cavity tones, and creation of new tones in the spectrum. State space models were useful for explaining some of these limitations, but were not able to account for non-linear dynamics, such as interactions between tones at different frequencies.

Cabell, Randolph H.↗

SIMULATION STUDY AND INITIAL TEST OF THESNS RING RF SYSTEM

The rfsimulator code was developed for the study of the Spallation Neutron Source (SNS) dual-harmonic ring RF control. It uses time-domain solvers to compute beam-cavity interactions and FFT methods to simulate the time responses of the linear RF system. The important elements of the system considered in the model include beam loading, dynamic cavity detuning, circuit bandwidth, loop delay, proportional-integral controller for feedback and adaptive feed forward, stochastic noise, width-in-turn loop parameter change, beam current fluctuation, and bunch leakage. As the beam power increases, beam loss in the ring goes up and thus precise control of the bunching RF phase and amplitude is required to limit beam loss. The code will help in the development of a functional RF control and in achieving the goal of minimizing beam loss in the accumulator ring.

43 PARTICLE ACCELERATORS↗

Tumor Bed Dynamics After Surgical Resection of Brain Metastases: Implications for Postoperative Radiosurgery

Purpose: To analyze 2 factors that influence timing of radiosurgery after surgical resection of brain metastases: target volume dynamics and intracranial tumor progression in the interval between surgery and cavity stereotactic radiosurgery (SRS). Methods and Materials: Three diagnostic magnetic resonance imaging (MRI) scans were retrospectively analyzed for 41 patients with a total of 43 resected brain metastases: preoperative MRI scan (MRI-1), MRI scan within 24 hours after surgery (MRI-2), and MRI scan for radiosurgery planning, which is generally performed {<=}1 week before SRS (MRI-3). Tumors were contoured on MRI-1 scans, and resection cavities were contoured on MRI-2 and MRI-3 scans. Results: The mean tumor volume before surgery was 14.23 cm{sup 3}, and the mean cavity volume was 8.53 cm{sup 3} immediately after surgery and 8.77 cm{sup 3} before SRS. In the interval between surgery and SRS, 20 cavities (46.5%) were stable in size, defined as a change of {<=}2 cm{sup 3}; 10 cavities (23.3%) collapsed by >2 cm{sup 3}; and 13 cavities (30.2%) increased by >2 cm{sup 3}. The unexpected increase in cavity size was a result of local progression (2 cavities), accumulation of cyst-like fluid or blood (9 cavities), and nonspecific postsurgical changes (2 cavities). Finally, in the interval between surgery and SRS, 5 cavities showed definite local tumor progression, 4 patients had progression elsewhere in the brain, 1 patient had both local progression and progression elsewhere, and 33 patients had stable intracranial disease. Conclusions: In the interval between surgical resection and delivery of SRS, surgical cavities are dynamic in size; however, most cavities do not collapse, and nearly one-third are larger at the time of SRS. These observations support obtaining imaging for radiosurgery planning as close to SRS delivery as possible and suggest that delaying SRS after surgery does not offer the benefit of cavity collapse in most patients. A prospective, multi-institutional trial will provide more guidance to the optimal timing of cavity SRS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NOVEL METHODS FOR EXPERIMENTAL CHARACTERIZATION OF 3D SUPERCONDUCTING LINAC BEAM DYNAMICS

This paper describes an approach to measure initial Twiss parameters in transverse and longitudinal directions at the entrance of a linac with independent short accelerating cavities. For the transverse plane the usual technique of transverse profiles is used, and for the longitudinal direction a recently developed non-intercepting method is applied. The new method is based on a beam position monitor amplitudes analysis. The applicability of the methods are discussed and demonstrated on an example of the Spallation Neutron Source superconducting linac.

Shishlo, Andrei P↗

Linear accelerator accelerating module to suppress back-acceleration of field-emitted particles

A method for the suppression of upstream-directed field emission in RF accelerators. The method is not restricted to a certain number of cavity cells, but requires similar operating field levels in all cavities to efficiently annihilate the once accumulated energy. Such a field balance is desirable to minimize dynamic RF losses, but not necessarily achievable in reality depending on individual cavity performance, such as early Q.sub.0-drop or quench field. The method enables a significant energy reduction for upstream-directed electrons within a relatively short distance. As a result of the suppression of upstream-directed field emission, electrons will impact surfaces at rather low energies leading to reduction of dark current and less issues with heating and damage of accelerator components as well as radiation levels including neutron generation and thus radio-activation.

43 PARTICLE ACCELERATORS↗

The Two-Cavity Method for Characterizing Acoustical Materials—an Interlaboratory Study

This study focuses on understanding the sound absorption characteristics of porous acoustic materials, which are determined by two key parameters independent of material thickness: characteristic impedance and propagation constant. These parameters can be characterized by testing a porous sample concept in a normal incidence impedance tube using either the two-thickness or the two-cavity method. In the two-thickness method, two samples of varying thicknesses are required. In contrast, the two-cavity method requires testing one sample at two different air cavity depths behind the porous material. This method is particularly advantageous for materials that are costly or challenging to fabricate. This interlaboratory study evaluates the variability of characteristic properties determined using the two-cavity method. Porous acoustic materials were additively manufactured and tested in the Liner Technology Facility(LTF)at NASA Langley Research Center and the Mechanics, Acoustics and Dynamics Lab (MADLab) at Michigan Technological University. The characteristic properties derived from various cavity depth combinations were used to predict the surface impedance of the sample with a rigid backing. The prediction was then compared the measured impedance spectrum. It was also found that the combinations of cavity depths can significantly influence the accuracy of the deduced properties.

acoustic liners↗

Intracavity dynamics in high-power mode-locked fiber lasers

A theoretical model is developed which characterizes the intracavity pulse evolutions in high-power fiber lasers. It is shown that experimentally observed dynamics of the key pulse parameters can be described by a reduced model of ordinary differential equations. Critical in driving the intracavity dynamics is the amplitude and phase modulations generated by the discrete elements in the laser. The theory gives a simple geometrical description of the intracavity dynamics and possible operation modes of the laser cavity. Furthermore, it provides a simple and efficient method for optimizing the performance of complex multiparametric laser systems.

43 PARTICLE ACCELERATORS↗

Application of extremum seeking for time-varying systems to resonance control of RF cavities

A recently developed form of extremum seeking for time-varying systems is implemented in hardware for the resonance control of radio-frequency cavities without phase measurements. Normal conducting RF cavity resonance control is performed via a slug tuner, while superconducting TESLA-type cavity resonance control is performed via piezo actuators. The controller maintains resonance by minimizing reflected power by utilizing model-independent adaptive feedback. Unlike standard phase-measurement-based resonance control, the presented approach is not sensitive to arbitrary phase shifts of the RF signals due to temperature-dependent cable length or phasemeasurement hardware changes. The phase independence of this method removes common slowly varying drifts and required periodic recalibration of phase-based methods. A general overview of the adaptive controller is presented along with the proof of principle experimental results at room temperature. Lastly, this method allows us to both maintain a cavity at a desired resonance frequency and also to dynamically modify its resonance frequency to track the unknown time-varying frequency of an RF source, thereby maintaining maximal cavity field strength, based only on power-level measurements.

47 OTHER INSTRUMENTATION↗

A Computational Study of a New Dual Throat Fluidic Thrust Vectoring Nozzle Concept

A computational investigation of a two-dimensional nozzle was completed to assess the use of fluidic injection to manipulate flow separation and cause thrust vectoring of the primary jet thrust. The nozzle was designed with a recessed cavity to enhance the throat shifting method of fluidic thrust vectoring. Several design cycles with the structured-grid, computational fluid dynamics code PAB3D and with experiments in the NASA Langley Research Center Jet Exit Test Facility have been completed to guide the nozzle design and analyze performance. This paper presents computational results on potential design improvements for best experimental configuration tested to date. Nozzle design variables included cavity divergence angle, cavity convergence angle and upstream throat height. Pulsed fluidic injection was also investigated for its ability to decrease mass flow requirements. Internal nozzle performance (wind-off conditions) and thrust vector angles were computed for several configurations over a range of nozzle pressure ratios from 2 to 7, with the fluidic injection flow rate equal to 3 percent of the primary flow rate. Computational results indicate that increasing cavity divergence angle beyond 10 is detrimental to thrust vectoring efficiency, while increasing cavity convergence angle from 20 to 30 improves thrust vectoring efficiency at nozzle pressure ratios greater than 2, albeit at the expense of discharge coefficient. Pulsed injection was no more efficient than steady injection for the Dual Throat Nozzle concept.

Deere, Karen A.↗

Operation and Optimization of Microwave-Heated Continuous-Flow Microfluidics

Microwave (MW) technology can be powerful for electrification and process intensification but limited fundamental understanding of scalability and design principles hinders its effective use. In this work, we build a continuous-flow microreactor inside a commercial single-mode MW applicator and the corresponding computational fluid dynamics model to simulate the temperature profile. The model is in good agreement with experiments for various microreactor dimensions and operating conditions. The model indicates that MW heating is greatly influenced by reactor geometry as well as the operating parameters. We observe a strong correlation between parameters and develop a gradient boost regression tree model to predict the outlet temperature accurately. This model is then applied to optimize the dimensions and operating conditions to maximize the outlet temperature and energy efficiency, resulting in a Pareto optimal. We demonstrate computationally and experimentally that it is possible to surpass the Pareto optimal and achieve an energy efficiency of ~90% or greater at temperatures relevant for liquid-phase chemistry via salting of the solvent. The present methodology can be applied to other complex MW reactors. Lastly, the combined numerical and experimental approach provides insights into and a framework for scale-up and optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Feedback Control of Flow Induced Cavity Tones

Discrete-time, linear quadratic methods were used to design feedback controllers for reducing tones generated by flow over a cavity. The dynamics of a synthetic jet actuator mounted at the leading edge of the cavity as observed by two microphones in the cavity were modeled over a broad frequency range using state space models computed from experimental data. Variations in closed loop performance as a function of model order, control order, control bandwidth, and state estimator design were studied using a cavity in the Probe Calibration Tunnel at NASA Langley. The controller successfully reduced the levels of multiple cavity tones at the tested flow speeds of Mach 0.275, 0.35, and 0.45. In some cases, the closed loop results were limited by excitation of sidebands of the cavity tones, or the creation of new tones at frequencies away from the cavity tones. Nonetheless, the results validate the combination of optimal control and experimentally-generated state space models, and suggest this approach may be useful for other flow control problems. The models were not able to account for non-linear dynamics, such as interactions between tones at different frequencies.

Cabell, Randolph H.↗

Fast and flexible control of beam longitudinal phase space for high-repetition-rate x-ray free-electron lasers

The wide-ranging requirements for the photon properties from multiple beamlines in superconducting based free-electron lasers (FELs) demand more challenging beam manipulation techniques. Shot-by-shot control of electron beam bunch length and peak current at high repetition rate up to megahertz is highly desired. In this paper, we present a comprehensive study of a method based on a 2-m-long normal conducting radio-frequency cavity to achieve fast and flexible control of beam compression and realize the full potential of the facility, including theoretical analysis, beam dynamics simulations, and conceptual cavity design for the Linac Coherent Light Source II and its high-energy upgrade. We illustrate the physical mechanism of the chirping cavity on the control of the final beam compression and propose methods to lower the requirements for the cavity parameters. The application of this method will allow tailored photon properties of individual beamlines to optimize their performance and drastically improve the multiplexing capabilities of a high-repetition rate FEL facility.

42 ENGINEERING↗

Measurement backaction on the quantum spin-mixing dynamics of a spin-1 Bose-Einstein condensate

We consider a small F=1 spinor condensate inside an optical cavity driven by an optical probe field, and subject the output of the probe to a homodyne detection, with the goal of investigating the effect of measurement backaction on the spin dynamics of the condensate. Using the stochastic master equation approach, we show that the effect of backaction is sensitive to not only the measurement strength but also the quantum fluctuation of the spinor condensate. The same method is also used to estimate the atom numbers below which the effect of backaction becomes so prominent that extracting spin dynamics from this cavity-based detection scheme is no longer practical.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cavity contour segmentation in chest radiographs using supervised learning and dynamic programming

Purpose: Efficacy of tuberculosis (TB) treatment is often monitored using chest radiography. Monitoring size of cavities in pulmonary tuberculosis is important as the size predicts severity of the disease and its persistence under therapy predicts relapse. The authors present a method for automatic cavity segmentation in chest radiographs. Methods: A two stage method is proposed to segment the cavity borders, given a user defined seed point close to the center of the cavity. First, a supervised learning approach is employed to train a pixel classifier using texture and radial features to identify the border pixels of the cavity. A likelihood value of belonging to the cavity border is assigned to each pixel by the classifier. The authors experimented with four different classifiers:k-nearest neighbor (kNN), linear discriminant analysis (LDA), GentleBoost (GB), and random forest (RF). Next, the constructed likelihood map was used as an input cost image in the polar transformed image space for dynamic programming to trace the optimal maximum cost path. This constructed path corresponds to the segmented cavity contour in image space. Results: The method was evaluated on 100 chest radiographs (CXRs) containing 126 cavities. The reference segmentation was manually delineated by an experienced chest radiologist. An independent observer (a chest radiologist) also delineated all cavities to estimate interobserver variability. Jaccard overlap measure Ω was computed between the reference segmentation and the automatic segmentation; and between the reference segmentation and the independent observer's segmentation for all cavities. A median overlap Ω of 0.81 (0.76 ± 0.16), and 0.85 (0.82 ± 0.11) was achieved between the reference segmentation and the automatic segmentation, and between the segmentations by the two radiologists, respectively. The best reported mean contour distance and Hausdorff distance between the reference and the automatic segmentation were, respectively, 2.48 ± 2.19 and 8.32 ± 5.66 mm, whereas these distances were 1.66 ± 1.29 and 5.75 ± 4.88 mm between the segmentations by the reference reader and the independent observer, respectively. The automatic segmentations were also visually assessed by two trained CXR readers as “excellent,” “adequate,” or “insufficient.” The readers had good agreement in assessing the cavity outlines and 84% of the segmentations were rated as “excellent” or “adequate” by both readers. Conclusions: The proposed cavity segmentation technique produced results with a good degree of overlap with manual expert segmentations. The evaluation measures demonstrated that the results approached the results of the experienced chest radiologists, in terms of overlap measure and contour distance measures. Automatic cavity segmentation can be employed in TB clinics for treatment monitoring, especially in resource limited settings where radiologists are not available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗