Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Amplitude effects on the dynamic performance of hydrostatic gas thrust bearings

A strip gas film bearing with inherently compensated inlets is analyzed to determine the effect of disturbance amplitude on its dynamic performance. The governing Reynolds' equation is solved using finite-difference techniques. The time dependent load capacity is represented by a Fourier series up to and including the third harmonics. For the range of amplitudes investigated the linear stiffness was independent of the amplitude, and the linear damping was inversely proportional to (1 - epsilon-squared) to the 1.5 power where epsilon is the amplitude relative to the film thickness.

Stiffler, A. K.↗

Momentary Cessation: Improving Dynamic Performance and Modeling of Utility-Scale Inverter Based Resources During Grid Disturbances

Sandia National Laboratories worked with NERC staff to provide stakeholder guidance in responding to a May 2018 NERC alert regarding dynamic performance and modeling issues for utility-scale inverter-based resources. The NERC alert resulted from event analyses for grid disturbances that occurred in southern California in August 2016 and October 2017. Those disturbances revealed the use of momentary cessation of transmission connected inverter-based generation- a short time period when they ceased to inject current into the grid, counter to desired transmission operation. The event analyses concluded that, in many cases, the Western Interconnection system models used to determine planning and operating criteria do not reflect the actual behavior of solar plants, resulting in overly optimistic planning assessments and substandard operational responses. This technical report summarizes the gaps between the models and actual performance that were observed at those times, and the guidance that Sandia and NERC provided to owners of solar PV power plants, transmission planners, transmission operators and planning/reliability coordinators to modify existing models to reflect that actual performance

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulation and dynamic performance of a 20-kHz spacecraft power system

A candidate 20-kHz spacecraft power system which includes a series-parallel combination of four Mapham inverters connected to several types of loads is described. A computer simulation of the power system is used to illustrate its steady-state and dynamic performance on an end-to-end basis. Comparisons with measured data are made. It is shown that significant distortion of the 20-kHz bus voltage can occur due to the switching of the load converters. This distortion can be reduced by including a shunt-connected parallel resonant filter on the 20-kHz side of the load converter. It is also shown that the distortion can be reduced by using a pulse-density-modulated switching strategy.

Wasynczuk, O.↗

Operation and Control of Electric Vehicle Charger with Enhanced Dynamic Performance Under Non-Ideal Grid Voltage Condition

This paper presents a three-phase electric vehicle charger connected to the grid, featuring multiple boost converters on the DC side, specifically designed to ensure smooth, oscillation-free power transfer during unsymmetrical voltage sags. Precise control mechanisms are implemented on the boost converter side to regulate both voltage and current on the electric vehicle side, thereby maintaining optimal charging conditions. The control architecture for both the grid-connected and boost converter components is based on the Lyapunov energy function, which is employed to achieve superior dynamic performance and stability. The system's robustness and reliability are demonstrated through its ability to maintain stable operation and efficient power transfer despite fluctuations in grid conditions. Furthermore, the implementation of Lyapunov-based control ensures rapid response and minimal energy loss, enhancing the overall efficiency of the system. To validate the effectiveness of this approach, a comprehensive model of the system was developed and tested using MATLAB/Simulink, with detailed computer simulations conducted across various significant case studies.

DC-DC boost converter↗

The Impact of System Latency on Dynamic Performance In Virtual Acoustic Environments

Engineering constraints that may be encountered when implementing interactive virtual acoustic displays are examined In particular, system parameters such as the update rate and total system latency are defined and the impact they may have on perception is discussed. For example, examination of the head motions that listeners used to aid localization in a previous study suggests that some head motions may be as fast as about 400 degrees/sec for short time periods. Analysis of latencies in virtual acoustic environments (VAEs) suggests that: (1) commonly-specified parameters such as the audio update rate determine only the "best-case" latency possible in a VAE, (2) total system latency and individual latencies of system components, including head-trackers, are frequently not measured by VAE developers, and (3) typical system latencies may result in under-sampling of relative listener-source motion of 400 degrees/sec as well as positional "jitter" in the simulated source. To clearly specify the dynamic performance of a particular VAE, users and developers need to make measurements of average system latency, update rate, and their variability using standardized rendering scenarios. a parameters such as the minimum audible movement angle can then be used as target guidelines to assess whether a given system meets perceptual requirements.

Wenzel, Elizabeth M.↗

Dynamic performance of a passively self-adjusting floating wind farm layout to increase the annual energy production

One of the main differences between floating offshore wind turbines (FOWTs) and fixed-bottom turbines is the angular and translational motions of FOWTs. When it comes to planning a floating wind farm (FWF), the translational motions introduce an additional layer of complexity to the FWF layout. The ability of a FOWT to relocate its position represents an opportunity to mitigate wake losses within an FWF. By passively relocating downwind turbines out of the wake generated by upwind turbines, we can reduce wake-induced energy losses and enhance overall energy production. The translational movements of FOWTs are governed by the mooring system attached to it. The way a FOWT relocates its position changes if the design of the mooring system attached to it changes. Additionally, the translational motion of a FOWT attached to a given mooring system is different for different wind directions. Hence, we can tailor a mooring system design for a FOWT to passively control its motions according to the wind direction. In this work, we present a new self-adjusting FWF layout design and assess its performance using both static and dynamic methods. The results show that relocating the FOWTs in an FWF can increase the energy production by 3 % using a steady-state wake model and 1.4 % using a dynamic wake model at a wind speed of 10 m s -1 . Moreover, we compare the fatigue and ultimate loads of the mooring systems of the self-adjusting FWF layout design to the mooring systems in a current state-of-the-art FWF baseline design. The comparison shows that with smaller mooring system diameters, the self-adjusting FWF design has similar fatigue damage compared to the baseline design with bigger mooring system diameters at rated wind speed. Finally, the ultimate loads on the mooring systems of the self-adjusting FWF design are lower than those on the mooring systems of the baseline design.

17 WIND ENERGY↗

Flight Dynamics Performances of the MetOp A Satellite during the First Months of Operations

The 19th of October 2006 at 16:28 UTC the first MetOp satellite (MetOp A) was successfully launched from the Baykonur cosmodrome by a Soyuz/Fregat launcher. After only three days of LEOP operations, performed by ESOC, the satellite was handed over to EUMETSAT, who is since then taking care of all satellite operations. MetOp A is the first European operational satellite for meteorology flying in a Low Earth Orbit (LEO), all previous satellites operated by EUMETSAT, belonging to the METEOSAT family, being located in the Geo-stationary orbit. To ensure safe operations for a LEO satellite accurate and continuous commanding from ground of the on-board AOCS is required. That makes the operational transition at the end of the LEOP quite challenging, as the continuity of the Flight Dynamics operations is to be maintained. That means that the main functions of the Flight Dynamics have to be fully validated on-flight during the LEOP, before taking over the operational responsibility on the spacecraft, and continuously monitored during the entire mission. Due to the nature of a meteorological operational mission, very stringent requirements in terms of overall service availability (99 % of the collected data), timeliness of processing of the observation data (3 hours after sensing) and accuracy of the geo-location of the meteorological products (1 km) are to be fulfilled. That translates in tight requirements imposed to the Flight Dynamics facility (FDF) in terms of accuracy, timeliness and availability of the generated orbit and clock solutions; a detailed monitoring of the quality of these products is thus mandatory. Besides, being the accuracy of the image geo-location strongly related with the pointing performance of the platform and with the on-board timing stability, monitoring from ground of the behaviour of the on-board sensors and clock is needed. This paper presents an overview of the Flight Dynamics operations performed during the different phases of the MetOp A mission up to routine. The activities performed to validate all the Flight Dynamics functions, characterize the behaviour of the satellite and monitor the performances of the Flight Dynamics facility will be highlighted. The MetOp Flight Dynamics Operations team is led by Anders Meier Soerensen and composed by Pier Luigi Righetti, Francisco Sancho, Antimo Damiano and David Lazaro. The team is supported by Hilda Meixner, responsible for all Flight Dynamics validation activities.

Righetti, Pier Luigi↗

Dynamic Performance Enhancement for Nonlinear Stochastic Systems Using RBF Driven Nonlinear Compensation with Extended Kalman Filter

In this paper, a novel hybrid control method is proposed to enhance the control performance of the PI based control system for a class of nonlinear and non-Gaussian stochastic dynamic processes with unmeasurable states. Firstly, to enhance the tracking performance of the PI controller where the PI parameters are fixed in many actual control systems, the compensative signal is formed using the extended Kalman filter(EKF) based state estimator and driven by the radial basis function (RBF) neural network based compensator. In addition, the weights of RBF is trained to minimize the entropy criterion of tracking error as the process is subjected to non-Gaussian disturbances. Meanwhile, since the precise statistical property of noises is hard to obtain for many industrial processes, the kernel density estimation (KDE) technique is employed in this paper to estimate the entropy. The convergence of RBF network is discussed and the stability of the resulted closed-loop hybrid control system is analyzed in mean square sense. Finally, a numerical example and a practical system testing are given to illustrate the effectiveness of the proposed control method.

stochastic systems, PI Controller, Entropy, Extend↗

Predicting dynamic performance limits for servosystems with saturating nonlinearities

A generalized treatment for a system with a single saturating nonlinearity is presented and compared with frequency response plots obtained from an analog model of the system. Once the amplitude dynamics are predicted with the limit lines, an iterative technique is employed to determine the system phase response. The saturation limit line technique is used in conjunction with velocity and acceleration limits to predict the performance of an electro-hydraulic servosystem containing a single-stage servovalve. Good agreement was obtained between predicted performance and experimental data.

Webb, J. A., Jr.↗

Dynamic Performance Comparison and Prediction based on Distribution-level Phasor Measurement Units

This paper introduces a new distribution level Phasor Measurement Unit (PMU) which adopts advanced hardware components and structure. The hardware parameters from the new PMU and the existing PMU are used to build a simulation model to predict the PMU performance. Therefore, a real-world testbench is built and four distribution level PMUs are tested under the steady-state and dynamic tests. The quantitative experiment result confirms the prediction model which could guide future PMU design, and also verifies the accuracy of the new PMU on the synchrophasor and frequency measurements in multiple scenarios.

Wu, Yuru↗

Dynamic performance and reflection sensitivity of quantum dot distributed feedback lasers with large optical mismatch

This work reports on a high-efficiency InAs/GaAs distributed feedback quantum dot laser. The large optical wavelength detuning at room temperature between the lasing peak and the gain peak causes the static, dynamic, and nonlinear intrinsic properties to all improve with temperature, including the lasing efficiency, the modulation dynamics, the linewidth enhancement factor, and consequently the reflection insensitivity. Results reported show an optimum operating temperature at 75°C, highlighting the potential of the large optical mismatch assisted single-frequency laser for the development of uncooled and isolator-free high-speed photonic integrated circuits.

Dong, Bozhang (ORCID:0000000158266723)↗

On-Orbit Structural Dynamics Performance of the Roll-Out Solar Array

The Roll-Out Solar Array (ROSA) flight experiment was launched to the International Space Station (ISS) on June 3rd, 2017. ROSA is an innovative, lightweight solar array with a flexible substrate that makes use of the stored strain energy in its composite structural members to provide deployment without the use of motors. This paper will discuss the results of various structural dynamics experiments conducted on the ISS during the weeks following launch. Data gathered from instrumentation on the solar array wing during the experiments are compared with pre-flight predictions from two different finite element modeling efforts. Two distinct methods were used to reconstruct the modal characteristics of ROSA from the data collected on orbit. Of particular interest in this effort are the first few system modes and mode shapes of the array, the amount of structural damping present, and degree of structural thermal interaction seen during eclipse exit. Discrepancies between the behavior predicted by the models and that observed on orbit are identified and discussed. The goal in this effort was to better understand the performance of ROSA and to improve modeling efforts for future designs of similar solar arrays.

Chamberlain, Matthew K.↗

Entry dynamics performance predictions for Pioneer Venus probes

The scientific experiments planned for the Pioneer Venus entry probes require that the probes provide a stable platform at a controlled roll rate throughout the atmospheric phase of the mission. The 45-degree half-cone forebody common to both the small and large probe configurations provides a design which meets all stability and attitude requirements. The uncertainty in the dynamic stability parameter coupled with the possible variability of roll rate due to ablation induced roll torques could, however, result in slight angle of attack divergence in the transonic flight regime. Minimum roll rate requirements on the small probe are passively achieved by a vane mounted on the pressure-temperature sensing arm. The vane was sized to provide minimum dynamic disturbance.

Mccloy, R. D.↗

Understanding Microstructural Effects on Dynamic Performance Towards the Development of Shock Metamaterials

With the recent advances in additive manufacturing (AM), long-range periodic lattice assemblies are being developed for vibration and shock mitigation components in aerospace and military applications with unique geometric and topological structures. There has been extensive work in understanding the static properties associated with varying topology of these lattice architectures, but there is almost no understanding of microstructural affects in such structures under high-strain rate dynamic loading conditions. Here we report the shock behavior of lattices with varying intrinsic grain structures achieved by post process annealing. High resolution 316L stainless steel lattices were 3D printed by a laser-powder bed fusion machine and characterized by computed tomography. Subsequent annealing resulted in stress-relieved and recrystallized lattices. Overall the lattices had strong cubic texture aligning with the x-, y- and z-directions of the build with a preference outside the build direction (z). The recrystallized sample had more equiaxed polygonal grains and a layer of BCC ferrite at the surface of the structure approximately 1 grain thick. Upon dynamic compression the as-deposited lattice showed steady compaction behavior while the heat-treated lattices exhibit negative velocity behavior indicative of failure. We attribute this to the stiffer BCC ferrite in the annealed lattices becoming damaged and fragmenting during compression.

36 MATERIALS SCIENCE↗

The dynamic performance of cavitating turbopumps

The evaluation of the transfer function for an axial cavitating inducer in a high performance turbopump is considered. An approach for the evaluation of the compliance and mass flow gain factor can be used as a basis for the determination of the first nonzero terms in the expansions of all the elements in the transfer function. Applications of the described method to turbopumps are discussed and the theoretical results are compared with test observations in the case of the Saturn J2 engine. It is demonstrated that a dynamic transfer function which includes not only a compliance but also a mass flow gain factor is a satisfactory first approximation for a cavitating turbopump.

Brennen, C.↗

A computational analysis of effective R-values of buried ducts – the dynamic performance of buried ducts

Here, this paper evaluates the thermal performance of ducts partially or fully buried in loose-fill attic insulation. The overall thermal resistance between the ducts and the attic is referred to as an effective R-value. This paper shows a strong dependency of assumed attic temperature on the effective R-value. Based on the results, the effective R-value can be about twice as much with an attic temperature of 130 °F [54.4 °C], compared to when the attic temperature is 80 °F [26.7 °C]. Thus, this paper provides a polynomial regression equation based on a large set of simulations to determine the effective R-value of buried ducts depending on attic temperature and whether the HVAC system runs in cooling or heating mode. Further, the work presented in this paper investigated the potential impact of convective airflow within the attic insulation, particularly around the ducts. The analysis was based on computational fluid dynamics (CFD) and indicated that convectional forces are presented around the exterior surface of the ducts, but with negligible impact on the overall heat balance between the duct and the attic space.

97 MATHEMATICS AND COMPUTING↗