Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron charge device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Camera selection for real-time in vivo radiation treatment verification systems using Cherenkov imaging

Purpose: To identify achievable camera performance and hardware needs in a clinical Cherenkov imaging system for real-time, in vivo monitoring of the surface beam profile on patients, as novel visual information, documentation, and possible treatment verification for clinicians. Methods: Complementary metal-oxide-semiconductor (CMOS), charge-coupled device (CCD), intensified charge-coupled device (ICCD), and electron multiplying-intensified charge coupled device (EM-ICCD) cameras were investigated to determine Cherenkov imaging performance in a clinical radiotherapy setting, with one emphasis on the maximum supportable frame rate. Where possible, the image intensifier was synchronized using a pulse signal from the Linac in order to image with room lighting conditions comparable to patient treatment scenarios. A solid water phantom irradiated with a 6 MV photon beam was imaged by the cameras to evaluate the maximum frame rate for adequate Cherenkov detection. Adequate detection was defined as an average electron count in the background-subtracted Cherenkov image region of interest in excess of 0.5% (327 counts) of the 16-bit maximum electron count value. Additionally, an ICCD and an EM-ICCD were each used clinically to image two patients undergoing whole-breast radiotherapy to compare clinical advantages and limitations of each system. Results: Intensifier-coupled cameras were required for imaging Cherenkov emission on the phantom surface with ambient room lighting; standalone CMOS and CCD cameras were not viable. The EM-ICCD was able to collect images from a single Linac pulse delivering less than 0.05 cGy of dose at 30 frames/s (fps) and pixel resolution of 512 × 512, compared to an ICCD which was limited to 4.7 fps at 1024 × 1024 resolution. An intensifier with higher quantum efficiency at the entrance photocathode in the red wavelengths [30% quantum efficiency (QE) vs previous 19%] promises at least 8.6 fps at a resolution of 1024 × 1024 and lower monetary cost than the EM-ICCD. Conclusions: The ICCD with an intensifier better optimized for red wavelengths was found to provide the best potential for real-time display (at least 8.6 fps) of radiation dose on the skin during treatment at a resolution of 1024 × 1024.

60 APPLIED LIFE SCIENCES↗

Tailoring coherent charge transport in graphene by deterministic defect generation

Harnessing the wave-nature of charge carriers in solid state devices, electron optics investigates and exploits coherent phenomena, in analogy with optics and photonics. Typically, this requires complex electronic devices leveraging macroscopically coherent charge transport in two-dimensional electron gases and superconductors. Here, collective coherent effects are induced in a simple counterintuitive architecture by defect engineering. Deterministically introduced lattice defects in graphene enable the phase coherent charge transport by playing the role of potential barriers, instead of scattering centres as conventionally considered. Thus, graphene preserves its quasi-ballistic quantum transport and can support phase-matched charge carrier waves. Based on this approach, multiple electronic Fabry-Pèrot cavities are formed by creating periodically alternating defective and pristine nano-stripes through low energy electron-beam irradiation. Indeed, defective stripes behave as partially reflecting mirrors and resonantly confine the charge carrier waves within the pristine areas, giving rise to Fabry-Pèrot resonant modes. These modes experimentally manifest as sheet resistance oscillations, as also confirmed by Landauer-Büttiker simulations. Moreover, these coherent phenomena survive up to 30 K for both polarities of charge carriers, contrarily to traditional monopolar electrostatically created Fabry-Pèrot interferometers. Our study positions defective graphene as an innovative platform for coherent electronic devices, with potential applications in nano and quantum technologies.

Melchioni, Nicola↗

Robustness of n-GaAs carrier spin properties to 5 MeV proton irradiation

Modern electronic devices utilize charge to transmit and store information. This leaves the information susceptible to external influences, such as radiation, that can introduce short timescale charge fluctuations and, long term, degrade electronic properties. Encoding information as spin polarizations offers an attractive alternative to electronic logic that should be robust to randomly polarized transient radiation effects. As a preliminary step towards radiation-resistant spintronic devices, we measure the spin properties of n-GaAs as a function of radiation fluence using time-resolved Kerr rotation and photoluminescence spectroscopy. Our results show a modest to negligible change in the long-term electron spin properties up to a fluence of 1 × 10{sup 14} (5 MeV protons)/cm{sup 2}, even as the luminescence decreases by two orders of magnitude.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spin-current diode with a ferromagnetic semiconductor

Diode is a key device in electronics: the charge current can flow through the device under a forward bias, while almost no current flows under a reverse bias. Here, we propose a corresponding device in spintronics: the spin-current diode, in which the forward spin current is large but the reversed one is negligible. We show that the lead/ferromagnetic quantum dot/lead system and the lead/ferromagnetic semiconductor/lead junction can work as spin-current diodes. The spin-current diode, a low dissipation device, may have important applications in spintronics, as the conventional charge-current diode does in electronics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Voltage Clock Driver for Photon-Counting CCD Characterization

A document discusses the CCD97 from e2v technologies as it is being evaluated at Goddard Space Flight Center's Detector Characterization Laboratory (DCL) for possible use in ultra-low background noise space astronomy applications, such as Terrestrial Planet Finder Coronagraph (TPF-C). The CCD97 includes a photoncounting mode where the equivalent output noise is less than one electron. Use of this mode requires a clock signal at a voltage level greater than the level achievable by the existing CCD (charge-coupled-device) electronics. A high-voltage waveform generator has been developed in code 660/601 to support the CCD97 evaluation. The unit generates required clock waveforms at voltage levels from -20 to +50 V. It deals with standard and arbitrary waveforms and supports pixel rates from 50 to 500 kHz. The system is designed to interface with existing Leach CCD electronics.

Baker, Robert↗

SISGR: Physical Chemistry of Reaction Dynamics in Ionic Liquids

Room temperature ionic liquids (RTILs) are liquids made up of atomic and molecular ions. This is in contrast with more common liquids, such as water, that are made up of neutral molecules. The additional charges on the atoms and molecules can alter the properties of these liquids, for example they tend to have a very high vapor pressure and the ability to shield charge in electronic devices. For these and other reasons RTILs have recently been deployed in a number of applications that involve production of free electrons in the liquid, such as batteries, capacitors, nuclear power plants, and solar cells. Electrons tend to be very reactive, and understanding their behaviour in these liquids is important for the future design of ionic liquids to be employed in these environments. This study investigated the behavior of electrons generated in RTILs by pulses of ultraviolet light, including how long they survive, and how reactive they are with the both the surrounding liquid and impurities in the liquid. The ionic liquid studied was one of the most commonly used, called N-alkyl-N-methyl-pyrrolidinium bistriflimide. What the study revealed was that the majority of the electrons initially created, about 96%, had a very short lifetime of less than one picosecond (10-12 second) due to a process called geminate recombination. The study also demonstrated that the electrons are very reactive at the moment they are detached from the molecules in the liquid by light, but that they relax very quickly and lose almost all of their reactivity in much less than one picosecond. The short lifetime and rapid loss of reactivity both serve as important mechanisms that protect the liquid from radiolytic damage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electronic pictures from charged-coupled devices

Imaging system uses charge-coupled devices (CCD's) to generate TV-like pictures with high resolution, sensitivity, and signal-to-noise ratio. It combines detectors for five spectral bands as well as processing and control circuitry all on single silicon chip.

Mccann, D. H.↗

New advancements in charge-coupled device technology - Sub-electron noise and 4096 x 4096 pixel CCDs

This paper reports on two new advancements in CCD technology. The first area of development has produced a special purpose CCD designed for ultra low-signal level imaging and spectroscopy applications that require sub-electron read noise floors. A nondestructive output circuit operating near its 1/f noise regime is clocked in a special manner to read a single pixel multiple times. Off-chip electronics average the multiple values, reducing the random noise by the square-root of the number of samples taken. Noise floors below 0.5 electrons rms are reported. The second development involves the design and performance of a high resolution imager of 4096 x 4096 pixels, the largest CCD manufactured in terms of pixel count. The device utilizes a 7.5-micron pixel fabricated with three-level poly-silicon to achieve high yield.

Janesick, James R.↗

Development of an X-ray pixel detector with multi-port charge-coupled device for X-ray free-electron laser experiments

This paper presents development of an X-ray pixel detector with a multi-port charge-coupled device (MPCCD) for X-ray Free-Electron laser experiments. The fabrication process of the CCD was selected based on the X-ray radiation hardness against the estimated annual dose of 1.6 × 10{sup 14} photon/mm{sup 2}. The sensor device was optimized by maximizing the full well capacity as high as 5 Me- within 50 μm square pixels while keeping the single photon detection capability for X-ray photons higher than 6 keV and a readout speed of 60 frames/s. The system development also included a detector system for the MPCCD sensor. This paper summarizes the performance, calibration methods, and operation status.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-Resolved High Resolution Neutron Imaging Studies at the ORNL Spallation Neutron Source

Our evaluation of a high-resolution digital imaging detector capable of providing millisecond time resolution and high sensitivity for neutrons is presented. This detector is a modified version of the high-resolution -ray imager developed previously at Radiation Monitoring Devices, Inc. (RMD, Inc.), and consists of an Electron Multiplying Charge Coupled Device (EMCCD) attached to a neutron-sensitive scintillator via a fiberoptic taper. By virtue of its internal gain, the EMCCD permits high speed readout without introducing additional noise, thereby enabling high frame rate operation with an enhanced signal-to-noise ratio (SNR). Detector sensitivity is enhanced through the use of a back-thinned EMCCD, which provides high quantum efficiency over a typical emission range for many neutron-sensitive scintillators. Preliminary evaluations conducted at the Liquids Reflectometer beam port of the Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL) demonstrate that this new detector has the sensitivity to detect individual neutrons and the acquisition speed to perform energy-selective imaging with a temporal resolution of milliseconds. While substantial improvements in timing and imaging performance are planned, this prototype detector has already generated the first ever images of the SNS Liquids Reflectometer beam profile and was also used to demonstrate a technique for obtaining Bragg edge transmission imaging using energy-selective neutrons. The preliminary data, along with the detector design, evaluation, and planned developments are discussed in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Molecular self ordering and charge transport in layer by layer deposited poly (3,3‴-dialkylquarterthiophene) films formed by Langmuir-Schaefer technique

The performance of π-conjugated polymer based electronic devices is directly governed by the molecular morphology of polymer aggregation, the extent to which a molecule is electronically coupled (self ordered and interacted) to neighboring molecules, and orientation. The well electronic coupled and crystalline/ordered polymer films have the potential to enhance the charge transport properties up to a benchmark. However, there is insufficient knowledge about the direct formation of large area, oriented, crystalline, and smooth films. In this study, we have presented Langmuir Schaefer technique to obtain the large area, oriented, crystalline, and smooth film of Poly (3,3‴-dialkylquarterthiophene) (PQT-12) polymer. The effect of self ordering and orientation of PQT-12 polymer on optical, morphological, and charge transport properties has been investigated. The prepared films have been characterized by UV-vis spectroscopy, Raman spectroscopy, transmission electron microscopy (TEM), selected area diffractions pattern (SAED), and atomic force microscopy (AFM) techniques. UV-vis spectra, TEM, SAED, and AFM images of monolayer films reveal the formation of well ordered and electronically coupled polymer domains. Layer by layer deposited films reveal the change in the orientation, which is confirmed by Raman spectra. Electronic properties and layer dependent charge transport properties are investigated using sandwiched structure Al/PQT-12/ITO Schottky configuration with perpendicular to the deposited films. It is observed that the charge transport properties and device electronic parameters (ideality factor and turn on voltage) are significantly changing with increasing the number of PQT-12 layers. Our study also demonstrates the charge transport between polymer crystallites and cause of deviation of ideal behavior of organic Schottky diodes. It may be further explored for improving the performance of other organic and optoelectronic devices.

36 MATERIALS SCIENCE↗

High resolution Cerenkov light imaging of induced positron distribution in proton therapy

Purpose: In proton therapy, imaging of the positron distribution produced by fragmentation during or soon after proton irradiation is a useful method to monitor the proton range. Although positron emission tomography (PET) is typically used for this imaging, its spatial resolution is limited. Cerenkov light imaging is a new molecular imaging technology that detects the visible photons that are produced from high-speed electrons using a high sensitivity optical camera. Because its inherent spatial resolution is much higher than PET, the authors can measure more precise information of the proton-induced positron distribution with Cerenkov light imaging technology. For this purpose, they conducted Cerenkov light imaging of induced positron distribution in proton therapy. Methods: First, the authors evaluated the spatial resolution of our Cerenkov light imaging system with a {sup 22}Na point source for the actual imaging setup. Then the transparent acrylic phantoms (100 × 100 × 100 mm{sup 3}) were irradiated with two different proton energies using a spot scanning proton therapy system. Cerenkov light imaging of each phantom was conducted using a high sensitivity electron multiplied charge coupled device (EM-CCD) camera. Results: The Cerenkov light’s spatial resolution for the setup was 0.76 ± 0.6 mm FWHM. They obtained high resolution Cerenkov light images of the positron distributions in the phantoms for two different proton energies and made fused images of the reference images and the Cerenkov light images. The depths of the positron distribution in the phantoms from the Cerenkov light images were almost identical to the simulation results. The decay curves derived from the region-of-interests (ROIs) set on the Cerenkov light images revealed that Cerenkov light images can be used for estimating the half-life of the radionuclide components of positrons. Conclusions: High resolution Cerenkov light imaging of proton-induced positron distribution was possible. The authors conclude that Cerenkov light imaging of proton-induced positron is promising for proton therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomistic study on dithiolated oligo-phenylenevinylene gated device

Thanks to their semiconducting behavior, conjugated molecules are considered as an attractive candidate for future electronic devices. Understanding the charge transport characteristics through such molecules for different device applications would accelerate the progress in the field of molecular electronics. In addition, it would become more feasible to introduce/enhance specific properties of molecular devices. This theoretical paper focuses on atomistic simulation and characterization of novel molecular FET employing dithiolated oligo-phenylenevinylene molecules. The simulation is validated by its agreement with the experimental measurements conducted on the same molecules. The employed molecule has oxygen linkers, which are responsible for the strongly nonlinear current characteristics on the molecular device. We perform a thorough atomistic device analysis to illustrate the principles behind the nonlinear current characteristics and the gating effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Seeing the invisible: Direct visualization of therapeutic radiation beams using air scintillation

Purpose: To assess whether air scintillation produced during standard radiation treatments can be visualized and used to monitor a beam in a nonperturbing manner. Methods: Air scintillation is caused by the excitation of nitrogen gas by ionizing radiation. This weak emission occurs predominantly in the 300–430 nm range. An electron-multiplication charge-coupled device camera, outfitted with an f/0.95 lens, was used to capture air scintillation produced by kilovoltage photon beams and megavoltage electron beams used in radiation therapy. The treatment rooms were prepared to block background light and a short-pass filter was utilized to block light above 440 nm. Results: Air scintillation from an orthovoltage unit (50 kVp, 30 mA) was visualized with a relatively short exposure time (10 s) and showed an inverse falloff (r{sup 2} = 0.89). Electron beams were also imaged. For a fixed exposure time (100 s), air scintillation was proportional to dose rate (r{sup 2} = 0.9998). As energy increased, the divergence of the electron beam decreased and the penumbra improved. By irradiating a transparent phantom, the authors also showed that Cherenkov luminescence did not interfere with the detection of air scintillation. In a final illustration of the capabilities of this new technique, the authors visualized air scintillation produced during a total skin irradiation treatment. Conclusions: Air scintillation can be measured to monitor a radiation beam in an inexpensive and nonperturbing manner. This physical phenomenon could be useful for dosimetry of therapeutic radiation beams or for online detection of gross errors during fractionated treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SENSEI: Characterization of Single-Electron Events Using a Skipper Charge-Coupled Device

We use a science-grade skipper charge-coupled device (skipper CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as "dark counts": dark current, amplifier light, and spurious charge. We measure a dark current, which depends on exposure, of (5.89±0.77)×10 -4 e - /pix/day, and an unprecedentedly low spurious charge contribution of (1.52±0.07)×10 -4 e - /pix, which is exposure independent. In addition, we provide a technique to study events produced by light emitted from the amplifier, which allows the detector's operation to be optimized to minimize this effect to a level below the dark-current contribution. Our accurate characterization of the single-electron events allows one to greatly extend the sensitivity of experiments searching for dark matter or coherent neutrino scattering. Moreover, an accurate understanding of the origin of single-electron events is critical to further progress in ongoing research and development efforts of skipper and conventional CCDs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗