Elementary review of electron microprobe techniques and correction requirements

Report contains requirements for correction of instrumented data on the chemical composition of a specimen, obtained by electron microprobe analysis. A condensed review of electron microprobe techniques is presented, including background material for obtaining X ray intensity data corrections and absorption, atomic number, and fluorescence corrections.

Hart, R. K.↗

Microstructural study of the nickel-base alloy WAZ-20 using qualitative and quantitative electron optical techniques

The NASA nickel-base alloy WAZ-20 was analyzed by advanced metallographic techniques to qualitatively and quantitatively characterize its phases and stability. The as-cast alloy contained primary gamma-prime, a coarse gamma-gamma prime eutectic, a gamma-fine gamma prime matrix, and MC carbides. A specimen aged at 870 C for 1000 hours contained these same constituents and a few widely scattered high W particles. No detrimental phases (such as sigma or mu) were observed. Scanning electron microscope, light metallography, and replica electron microscope methods are compared. The value of quantitative electron microprobe techniques such as spot and area analysis is demonstrated.

Young, S. G.↗

The Application of Electron Microscopy Techniques to the Space Shuttle Columbia Accident Investigation

The Space Shuttle Columbia was returning from a 16-day research mission, STS- 107, with nominal system performance prior to the beginning of the entry interface into earth's upper atmosphere. Approximately one minute and twenty four seconds into the peak heating region of the entry interface, an off-nominal temperature rise was observed in the left main landing gear brake line. Nearly seven minutes later, all contact was lost with Columbia. Debris was observed periodically exiting the Shuttle's flight path throughout the reentry profile over California, Nevada, and New Mexico, until its final breakup over Texas. During the subsequent investigation, electron microscopy techniques were crucial in revealing the location of the fatal damage that resulted in the loss of Columbia and her crew.

Shah, Sandeep↗

Phase segregation dynamics in mixed-halide perovskites revealed by plunge-freeze cryo-electron microscopy

Mixed-halide lead perovskites, with photoexcited charge-carrier properties suitable for high-efficiency photovoltaics, hold significant promise for high-efficiency tandem solar cells. However, phase segregation under illumination, where an iodide-rich phase forms carrier trap states, remains a barrier to application. This study employs plunge-freeze cryoelectron microscopy to visualize nanoscale phase segregation dynamics in CsPb(Br x I 1–x ) 3 films. By rapidly freezing the illuminated samples, we preserve transient photoexcited ion distributions for high-resolution structural and compositional analysis at the nanoscale. Cryogenic scanning transmission electron microscopy (STEM) techniques (electron energy loss spectroscopy [EELS] and 4D-STEM) captured the dynamics of photo-induced iodine migration from grain boundaries to centers, identified the buildup of anisotropic strain, and captured the heterogeneous evolution of this process within a single grain. These findings provide insight into microscopic phase segregation mechanisms and their dynamics, enhancing our understanding of mixed-halide perovskite photostability.

42 ENGINEERING↗

Electronic Packaging Techniques

A characteristic of aerospace system design is that equipment size and weight must always be kept to a minimum, even in small components such as electronic packages. The dictates of spacecraft design have spawned a number of high-density packaging techniques, among them methods of connecting circuits in printed wiring boards by processes called stitchbond welding and parallel gap welding. These processes help designers compress more components into less space; they also afford weight savings and lower production costs.

Source record↗

Developments in electronic imaging techniques; Proceedings of the Seminar-in-Depth, San Mateo, Calif., October 16, 17, 1972.

Capabilities and limitations of infrared imaging systems are discussed, and a real-time simulator for image data systems is described. Ultrahigh resolution electronic imaging and storage with the return beam vidicon is treated, and a description is given of an electron-lens for opaque photocathodes. Ground surveillance with an active low light level TV, digital processing of Mariner 9 TV data, image enhancement by holography, and application of data compression techniques to spacecraft imaging systems are given attention. Individual items are announced in this issue.

Zirkind, R.↗

Characterization of fluorite-structured ferroelectrics using transmission electron microscopy: Techniques, challenges, and recent advances

Fluorite-structured ferroelectrics, such as hafnium oxide and its alloyed variants, are key candidates for next-generation memory devices. Yet, fundamental questions about switching mechanisms, domain dynamics, and phase evolution remain open. Transmission electron microscopy (TEM) provides unique capabilities to address these challenges by simultaneously resolving the positions of anions and cations, chemical variations, and structural transformations. Recent advances—including in situ heating, electron beam-induced switching, electron energy loss spectroscopy, and differential phase contrast imaging—have revealed critical insights into phase transitions, potential switching pathways, and oxygen vacancy behavior. However, experimental barriers such as TEM sample-preparation-induced artifacts, high coercive fields, and imaging constraints persist, especially for polycrystalline films. By offering a focused overview of current TEM developments in fluorite ferroelectrics, this work outlines how TEM contributes to understanding key phenomena and proposes a roadmap for future studies.

36 MATERIALS SCIENCE↗

Observation of formation and local structures of metal-organic layers via complementary electron microscopy techniques

Abstract Metal-organic layers (MOLs) are highly attractive for application in catalysis, separation, sensing and biomedicine, owing to their tunable framework structure. However, it is challenging to obtain comprehensive information about the formation and local structures of MOLs using standard electron microscopy methods due to serious damage under electron beam irradiation. Here, we investigate the growth processes and local structures of MOLs utilizing a combination of liquid-phase transmission electron microscopy, cryogenic electron microscopy and electron ptychography. Our results show a multistep formation process, where precursor clusters first form in solution, then they are complexed with ligands to form non-crystalline solids, followed by the arrangement of the cluster-ligand complex into crystalline sheets, with additional possible growth by the addition of clusters to surface edges. Moreover, high-resolution imaging allows us to identify missing clusters, dislocations, loop and flat surface terminations and ligand connectors in the MOLs. Our observations provide insights into controllable MOL crystal morphology, defect engineering, and surface modification, thus assisting novel MOL design and synthesis.

36 MATERIALS SCIENCE↗

Determination of trace element mineral/liquid partition coefficients in melilite and diopside by ion and electron microprobe techniques

The applicability of ion microprobe (IMP) for quantitative analysis of minor elements (Sr, Y, Zr, La, Sm, and Yb) in the major phases present in natural Ca-, Al-rich inclusions (CAIs) was investigated by comparing IMP results with those of an electron microprobe (EMP). Results on three trace-element-doped glasses indicated that it is not possible to obtain precise quantitative analysis by using IMP if there are large differences in SiO2 content between the standards used to derive the ion yields and the unknowns.

Kuehner, S. M.↗

Emerging anomaly detection techniques for electronic health records: A survey

Background Anomaly detection in electronic health records (EHRs) is a cornerstone of biomedical informatics, with direct implications for patient safety, clinical decision-making, and the prevention of healthcare fraud. Once guided primarily by simple rule-based methods, the field has advanced rapidly, driven by increased computing power, richer and more detailed health data, and the rise of machine learning and deep learning techniques. The objective of this paper is to provide a comprehensive overview of modern approaches to detecting anomalies in EHRs, outlining their strengths, limitations, and relevance to key healthcare challenges. We review traditional statistical methods alongside newer ML- and DL-based strategies and hybrid models, with particular attention to how these techniques support transparency and build clinical trust. Methods This paper presents a thorough and critical survey through systematic review (PRISMA-based) of the latest anomaly detection strategies in time-sequence data domains within electronic health record systems. Results We explore a broad spectrum of methodologies, including statistical models, supervised and unsupervised learning approaches, hybrid frameworks, and state-of-the-art ML-based techniques that collectively advance the precision and scalability of detecting anomalies in complex clinical datasets. In addition to mapping current capabilities, we address the enduring challenges that hinder widespread implementation and provide a forward-looking perspective on the future of anomaly detection in the data-rich landscape of modern healthcare. Summary The advancement in AI-based approaches is reported along with the basic principles of the individual approaches and their applicability. The increased availability of high-quality data, advancements in DL approaches, and enhanced computation power are leading to more frequent adaptation of DL-based approaches. Emerging DL-based approaches that have been adapted in other domains or recently applied in the EHR domain are also discussed in detail. Although DL-based approaches can improve model predictions by incorporating comorbidities, their application is limited in low-frequency data domains (e.g., when the total available data remains in the single digits). Therefore, the user must carefully consider the application based on data availability.

Anomaly detection↗

Application of Electron Microscopy Techniques to the Investigation of Space Shuttle Columbia Accident

This viewgraph presentation gives an overview of the investigation into the breakup of the Space Shuttle Columbia, and addresses the importance of a failure analysis strategy for the investigation of the Columbia accident. The main focus of the presentation is on the usefulness of electron microscopy for analyzing slag deposits from the tiles and reinforced carbon-carbon (RCC) wing panels of the Columbia orbiter.

Shah, Sandeep↗

Contrast Mechanisms in Secondary Electron e-Beam-Induced Current (SEEBIC) Imaging

Abstract Over the last few years, a new mode for imaging in the scanning transmission electron microscope (STEM) has gained attention as it permits the direct visualization of sample conductivity and electrical connectivity. When the electron beam (e-beam) is focused on the sample in the STEM, secondary electrons (SEs) are generated. If the sample is conductive and electrically connected to an amplifier, the SE current can be measured as a function of the e-beam position. This scenario is similar to the better-known scanning electron microscopy-based technique, electron beam-induced current imaging, except that the signal in the STEM is generated by the emission of SEs, hence the name secondary electron e-beam-induced current (SEEBIC), and in this case, the current flows in the opposite direction. Here, we provide a brief review of recent work in this area, examine the various contrast generation mechanisms associated with SEEBIC, and illustrate its use for the characterization of graphene nanoribbon devices.