Search NASA⌕ Search

SEARCH · Search NASA

Results for “endoscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Multidetector-Row Computed Tomography in the Evaluation of Transjugular Intrahepatic Portosystemic Shunt Performed with Expanded-Polytetrafluoroethylene-Covered Stent-Graft

We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound-color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findings and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Extraction of Cement Leakage After Vertebroplasty Under CT and Fluoroscopy Guidance: A New Technique

Purpose: We report a new minimally invasive technique of extraction of cement leakage following percutaneous vertebroplasty in adults. Methods: Seven adult patients (five women, two men; mean age: 81 years) treated for vertebral compression fractures by percutaneous vertebroplasty had cement leakage into perivertebral soft tissues along the needle route. Immediately after vertebroplasty, the procedure of extraction was performed under computed tomography (CT) and fluoroscopy guidance: a Chiba needle was first inserted using the same route as the vertebroplasty until contact was obtained with the cement fragment. This needle was then used as a guide for an 11-gauge Trocar t'am (Thiebaud, France). After needle withdrawal, a 13-gauge endoscopy clamp was inserted through the cannula to extract the cement fragments. The whole procedure was performed under local anesthesia. Results: In each patient, all cement fragments were withdrawn within 10 min, without complication. Conclusions: This report suggests that this CT- and fluoroscopy-guided percutaneous technique of extraction could reduce the rate of cement leakage-related complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Digestive Tract Complications of Renal Cryoablation

We report a case each of duodenorenal and colorenal fistula that arose after computed tomography-guided percutaneous cryoablation (PCA) for renal cell carcinoma and use imaging and endoscopic findings to analyze their causes and mechanisms. Both complications occurred though the edge of the iceball did not touch the intestinal wall, and patients’ symptoms and fistula formation occurred several days after the PCA procedure. Based on imaging and endoscopy findings, we suspected the colorenal fistula resulted from bowel injury caused by ischemia from the occlusion of small vessels at the procedure’s low temperature. Both cases were resolved conservatively without surgical intervention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Balloon-Occluded Retrograde Transvenous Obliteration (BRTO) Using Ethanolamine Oleate (EO), BRTO Using Sodium Tetradecyl Sulfate (STS) Foam and Vascular Plug-Assisted Retrograde Transvenous Obliteration (PARTO)

PurposeTo compare the clinical outcomes of balloon-occluded retrograde transvenous obliteration (BRTO) using ethanolamine oleate (EO), BRTO using sodium tetradecyl sulfate (STS) foam, and vascular plug-assisted retrograde transvenous obliteration (PARTO).Materials and MethodsFrom April 2004 to February 2015, ninety-five patients underwent retrograde transvenous obliteration for gastric varices were analyzed retrospectively. BRTO with EO was performed in 49 patients, BRTO with STS foam in 25, and PARTO in 21. Among them, we obtained follow-up data in 70 patients. Recurrence of gastric varices was evaluated by follow-up endoscopy or CT. Medical records were reviewed for the clinical efficacy. Statistical analyses were performed by Kaplan–Meier method, Chi-square, Fisher’s, and Kruskal–Wallis tests.ResultsTechnical and clinical success was 94.7 %. As major complications, a hemoglobinuria and a death due to disseminated intravascular coagulation (DIC) were occurred in two patients with BRTO using EO. Recurrence occurred more frequently in PARTO group (P < 0.05). Recurrence occurred in three patients in BRTO using EO group and four patients in PARTO group with 3.2 and 32.8 % of each expected 1-year recurrence rates. There was no recurrence in BRTO using STS group. Abdominal pain occurred more frequently in BRTO using EO than BRTO using STS foam and PARTO (P < 0.05). Procedure time of PARTO was shorter than two conventional BRTOs (P < 0.05).ConclusionsBRTO using STS foam or PARTO is better than BRTO using EO for treatment of gastric varices in terms of complication or procedure time. However, PARTO showed frequent recurrence of gastric varices during the long-term follow-up rather than BRTO.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bariatric Arterial Embolization with Non-spherical Polyvinyl Alcohol Particles for Ghrelin Suppression in a Swine Model

PurposeTo evaluate the effect of bariatric arterial embolization (BAE) with non-spherical polyvinyl alcohol (PVA) particles on systemic ghrelin levels, weight change, and gastric ulceration risk in a swine model.Materials and MethodsFrom March 2014 to February 2015, ten healthy swine were used in the study (mean weight 31.5 kg; range 24.0–41.5 kg). The animals were randomly assigned to two groups: the embolized group (n = 5) in which BAE was performed and the control group (n = 5). In the embolized group, BAE was performed by selectively infusing 150–250 or 50–150 μm PVA into the gastric arteries that supplied the fundus of the stomach. In the control group, a sham procedure was performed with saline infusion. Plasma ghrelin levels were prospectively obtained at baseline and every 2 weeks thereafter. Endoscopy was performed 3 weeks after BAE to see whether any gastric ulcer occurred. To determine the durability of the occluded arteries, repeated celiac trunk angiography was performed 8 weeks after BAE. Then, all the swine were killed and necropsies were performed.ResultsThe mean post-procedure ghrelin value decreased by 370.0 pg/mL in the embolized group at week 3 (mean 536.0 ± 334.3 pg/mL) and week 5 (mean 515.0 ± 150.0 pg/mL, p < 0.05) relative to baseline (880.0 ± 559.5 pg/mL), respectively, but ghrelin levels were not significantly decreased between the embolized and control groups. There was a significant body weight change as follows: 35.1 ± 9.5 to 46.6 ± 15.7 kg and 31.8 ± 5.8 to 41.2 ± 6.6 kg at baseline and endpoint in the control and embolized groups, respectively (p < 0.05). However, the difference between groups was not significant at endpoint. In the embolized group, ulcerations were identified in three animals (60%) and the recanalization of the embolized arteries was noted on follow-up angiography in three animals (60%), respectively.ConclusionBAE with PVA particles can transiently suppress ghrelin levels in embolized animals, but levels are not significantly different compared to controls. Stomach ulcerations were identified in 60% of the embolized animals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proteomic analysis of minute amount of colonic biopsies by enteroscopy sampling

Colorectal cancer (CRC) is one of the most common types of malignant tumor worldwide. Currently, although many researchers have been devoting themselves in CRC studies, the process of locating biomarkers for CRC early diagnosis and prognostic is still very slow. Using a centrifugal proteomic reactor-based proteomic analysis of minute amount of colonic biopsies by enteroscopy sampling, 2620 protein groups were quantified between cancer mucosa and adjacent normal colorectal mucosa. Of which, 403 protein groups were differentially expressed with statistic significance between cancer and normal tissues, including 195 up-regulated and 208 down-regulated proteins in cancer tissues. Three proteins (SOD3, PRELP and NGAL) were selected for further Western blot validation. And the resulting Western blot experimental results were consistent with the quantitative proteomic data. SOD3 and PRELP are down-regulated in CRC mucosa comparing to adjacent normal tissue, while NGAL is up-regulated in CRC mucosa. In conclusion, the centrifugal proteomic reactor-based label-free quantitative proteomic approach provides a highly sensitive and powerful tool for analyzing minute protein sample from tiny colorectal biopsies, which may facilitate CRC biomarkers discovery for diagnoses and prognoses. -- Highlights: •Minute amount of colonic biopsies by endoscopy is suitable for proteomic analysis. •Centrifugal proteomic reactor can be used for processing tiny clinic biopsy sample. •SOD3 and PRELP are down-regulated in CRC, while NGAL is up-regulated in CRC.

60 APPLIED LIFE SCIENCES↗

Concurrent Liposomal Cisplatin (Lipoplatin), 5-Fluorouracil and Radiotherapy for the Treatment of Locally Advanced Gastric Cancer: A Phase I/II Study

Purpose: Liposomal drugs have a better tolerance profile and are highly accumulated in the tumor environment, properties that promise an optimal radiosensitization. We investigated the feasibility of the combination of 5-fluorouracil/lecovorin-based radio-chemotherapy with the administration of high weekly dose of a liposomal platinum formulation (Lipoplatin{sup TM}). Methods and Materials: Lipoplatin was given at a dose of 120mg/m{sup 2}/week, 5-fluorouracil at 400mg/m{sup 2}/week (Day 1), whereas radiotherapy was given through 3.5-Gy fractions on Days 2, 3, and 4. Two groups of 6 patients received four and five consecutive cycles, respectively. Results: Minimal nephrotoxicity (18.2% Grade 1) and neutropenia (9% Grade 3) was noted. Fatigue Grade 2 appeared in 25% of cases. Abdominal discomfort was reported by 18% of patients. No liver, kidney, gastric, or intestinal severe acute or late sequellae were documented, although the median follow-up of 9 months is certainly too low to allow safe conclusions. A net improvement in the performance status (from a median of 1 to 0) was recorded 2 months after the end of therapy. The response rates assessed with computed tomography, endoscopy, and biopsies confirmed 33% (2 of 6) tumor disappearance in patients treated with four cycles, which reached 80% (4 of 5) in patients receiving five cycles. Conclusions: Lipoplatin radio-chemotherapy is feasible, with minor hematological and nonhematological toxicity. The high complete response rates obtained support the testing of Lipoplatin in the adjuvant postoperative or preoperative radio-chemotherapy setting for the treatment of gastric cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gastroduodenal Complications After Concurrent Chemoradiation Therapy in Patients With Hepatocellular Carcinoma: Endoscopic Findings and Risk Factors

Purpose: Concurrent chemoradiation therapy (CCRT) is useful in advanced hepatocellular carcinoma (HCC), but little is known about radiation-induced gastroduodenal complications following therapy. To determine risk factors, we investigated the prevalence and patterns of gastroduodenal complications following CCRT using endoscopy. Methods and Materials: Enrolled in the study were 123 patients treated with CCRT for unresectable HCC between January 1998 and December 2005. Radiation-induced gastroduodenal complications were defined as radiation gastritis/duodenitis, radiation gastric/duodenal ulcer, or other gastroduodenal toxicity associated with radiation, based on Common Terminology Criteria for Adverse Events (CTCAE 3.0). Serious gastroduodenal complications were defined as events occurring within 12 months from completion of CCRT, those requiring prompt therapeutic intervention, or symptoms equivalent to Grade 3 or 4 radiation-related gastroduodenal toxicity, including nausea or vomiting, based on CTCAE 3.0. Results: A month after completion of CCRT, 65 (52.8%) patients displayed endoscopic evidence of radiation-induced gastroduodenal complications. Radiation gastric and duodenal ulcers were found in 32 (26.0%) and 20 (16.3%) patients, respectively; radiation gastritis and duodenitis were found in 50 (40.7%) and 42 (34.1%) patients, respectively. Radiation-related bleeding was observed in 13 patients (10.6%). Serious gastroduodenal complications occurred in 18 patients (14.6%) and were significantly more frequent in patients with liver cirrhosis than in those without cirrhosis (p = 0.043). There were no radiation-related deaths. Conclusions: Endoscopically detectable radiation-induced gastroduodenal complications were common in HCC following CCRT. Although serious complications were uncommon, the frequency was higher in patients with liver cirrhosis; thus, these patients should be closely monitored when receiving CCRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fibroblast Growth Factor 2-A Predictor of Outcome for Patients Irradiated for Stage II-III Non-Small-Cell Lung Cancer

Purpose: The prognostic value of the tumor cell expression of the fibroblast growth factor 2 (FGF-2) in patients with non-small-cell lung cancer (NSCLC) is unclear. The present study investigated the effect of tumor cell expression of FGF-2 on the outcome of 60 patients irradiated for Stage II-III NSCLC. Methods and Materials: The effect of FGF-2 expression and 13 additional factors on locoregional control (LRC), metastasis-free survival (MFS), and overall survival (OS) were retrospectively evaluated. These additional factors included age, gender, Karnofsky performance status, histologic type, histologic grade, T and N category, American Joint Committee on Cancer stage, surgery, chemotherapy, pack-years, smoking during radiotherapy, and hemoglobin during radiotherapy. Locoregional failure was identified by endoscopy or computed tomography. Univariate analyses were performed with the Kaplan-Meier method and the Wilcoxon test and multivariate analyses with the Cox proportional hazard model. Results: On univariate analysis, improved LRC was associated with surgery (p = .017), greater hemoglobin levels (p = .036), and FGF-2 negativity (p <.001). On multivariate analysis of LRC, surgery (relative risk [RR], 2.44; p = .037), and FGF-2 expression (RR, 5.06; p <.001) maintained significance. On univariate analysis, improved MFS was associated with squamous cell carcinoma (p = .020), greater hemoglobin levels (p = .007), and FGF-2 negativity (p = .001). On multivariate analysis of MFS, the hemoglobin levels (RR, 2.65; p = .019) and FGF-2 expression (RR, 3.05; p = .004) were significant. On univariate analysis, improved OS was associated with a lower N category (p = .048), greater hemoglobin levels (p <.001), and FGF-2 negativity (p <.001). On multivariate analysis of OS, greater hemoglobin levels (RR, 4.62; p = .002) and FGF-2 expression (RR, 3.25; p = .002) maintained significance. Conclusions: Tumor cell expression of FGF-2 appeared to be an independent negative predictor of LRC, MFS, and OS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary Results of Fractionated Stereotactic Radiotherapy After Cyst Drainage for Craniopharyngioma in Adults

Purpose: To retrospectively evaluate the effectiveness of fractionated stereotactic radiotherapy (FSRT) for craniopharyngioma. Methods and Materials: Between 1999 and 2005, 16 patients with craniopharyngioma were referred to Tokyo Medical University Hospital. They received FSRT alone after histologic confirmation by needle biopsy and underwent cyst drainage via endoscopy. The median prescription dose fraction was 30 Gy in six fractions. All patients except 1 were followed up until December 2009 or death. Results: The median follow-up period was 52 months (range, 4-117 months). Of the 17 patients, 3 experienced recurrence 4 to 71 months after FSRT. The 3-year local control rate was 82.4%. One patient died of thyroid cancer, and the 3-year survival rate was 94.1%. Eight patients had improved visual fields at a median of 2.5 months after FSRT, but hormonal functions did not improve in any patient. Conclusions: FSRT after cyst drainage seems to be safe and effective for patients with craniopharyngiomas, and it may be a safe alternative to surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Predictors of Duodenal Toxicity After Intensity Modulated Radiation Therapy for Treatment of the Para-aortic Nodes in Gynecologic Cancer

Purpose: To determine the incidence of duodenal toxicity in patients receiving intensity modulated radiation therapy (IMRT) for treatment of para-aortic nodes and to identify dosimetric parameters predictive of late duodenal toxicity. Methods and Materials: We identified 105 eligible patients with gynecologic malignancies who were treated with IMRT for gross metastatic disease in the para-aortic nodes from January 1, 2005, through December 31, 2009. Patients were treated to a nodal clinical target volume to 45 to 50.4 Gy with a boost to 60 to 66 Gy. The duodenum was contoured, and dosimetric data were exported for analysis. Duodenal toxicity was scored according to Radiation Therapy Oncology Group criteria. Univariate Cox proportional hazards analysis and recursive partitioning analysis were used to determine associations between dosimetric variables and time to toxicity and to identify the optimal threshold that separated patients according to risk of toxicity. Results: Nine of the 105 patients experienced grade 2 to grade 5 duodenal toxicity, confirmed by endoscopy in all cases. The 3-year actuarial rate of any duodenal toxicity was 11.7%. A larger volume of the duodenum receiving 55 Gy (V55) was associated with higher rates of duodenal toxicity. The 3-year actuarial rates of duodenal toxicity with V55 above and below 15 cm{sup 3} were 48.6% and 7.4%, respectively (P<.01). In Cox univariate analysis of dosimetric variables, V55 was associated with duodenal toxicity (P=.029). In recursive partitioning analysis, V55 less than 13.94% segregated all patients with duodenal toxicity. Conclusions: Dose-escalated IMRT can safely and effectively treat para-aortic nodal disease in gynecologic malignancies, provided that care is taken to limit the dose to the duodenum to reduce the risk of late duodenal toxicity. Limiting V55 to below 15 cm{sup 3} may reduce the risk of duodenal complications. In cases where the treatment cannot be delivered within these constraints, consideration should be given to other treatment approaches such as resection or initial chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of voltage waveform and tube diameter on transporting cold plasma strings through a flexible dielectric tube

In this work, we developed transporting atmospheric pressure cold plasma using single electrode configuration through a sub-millimetre flexible dielectric tube beyond 100 cm. It was shown that the waveform of the applied high voltage is essential for controlling upstream and downstream plasma inside the tube. In this regard, sawtooth waveform enabled the transport of plasma with less applied high voltage compared to sinusoidal and pulsed form voltages. A cold plasma string as long as 130 cm was obtained by only 4 kV peak-to-peak sawtooth high voltage waveform. Optical emission spectroscopy revealed that reactive chemical species, such as atomic oxygen and hydroxyl, are generated at the tube exit. The effect of tube diameter on the transported plasma was also examined: the smaller the diameter, the higher the applied voltage. The device is likely to be used for sterilization, decontamination, and therapeutic endoscopy as already suggested by other groups in recent past years.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robust electromagnetically guided endoscopic procedure using enhanced particle swarm optimization for multimodal information fusion

Purpose: Electromagnetically guided endoscopic procedure, which aims at accurately and robustly localizing the endoscope, involves multimodal sensory information during interventions. However, it still remains challenging in how to integrate these information for precise and stable endoscopic guidance. To tackle such a challenge, this paper proposes a new framework on the basis of an enhanced particle swarm optimization method to effectively fuse these information for accurate and continuous endoscope localization. Methods: The authors use the particle swarm optimization method, which is one of stochastic evolutionary computation algorithms, to effectively fuse the multimodal information including preoperative information (i.e., computed tomography images) as a frame of reference, endoscopic camera videos, and positional sensor measurements (i.e., electromagnetic sensor outputs). Since the evolutionary computation method usually limits its possible premature convergence and evolutionary factors, the authors introduce the current (endoscopic camera and electromagnetic sensor’s) observation to boost the particle swarm optimization and also adaptively update evolutionary parameters in accordance with spatial constraints and the current observation, resulting in advantageous performance in the enhanced algorithm. Results: The experimental results demonstrate that the authors’ proposed method provides a more accurate and robust endoscopic guidance framework than state-of-the-art methods. The average guidance accuracy of the authors’ framework was about 3.0 mm and 5.6° while the previous methods show at least 3.9 mm and 7.0°. The average position and orientation smoothness of their method was 1.0 mm and 1.6°, which is significantly better than the other methods at least with (2.0 mm and 2.6°). Additionally, the average visual quality of the endoscopic guidance was improved to 0.29. Conclusions: A robust electromagnetically guided endoscopy framework was proposed on the basis of an enhanced particle swarm optimization method with using the current observation information and adaptive evolutionary factors. The authors proposed framework greatly reduced the guidance errors from (4.3, 7.8) to (3.0 mm, 5.6°), compared to state-of-the-art methods.

60 APPLIED LIFE SCIENCES↗

Stereoscopic displays and applications; Proceedings of the Meeting, Santa Clara, CA, Feb. 12-14, 1990

The present conference discusses topics in the fields of stereoscopic displays' user interfaces, three-dimensional (TD) visualization, novel TD displays, and applications of stereoscopic displays. Attention is given to TD cockpit displays, novel computational control techniques for stereo TD displays, characterization of higher-dimensional presentation techniques, volume visualization on a stereoscopic display, and stereoscopic displays for terrain-data base visualization. Also discussed are the experimental design of cyberspaces, a volumetric environment for interactive design of three-dimensional objects, videotape recording of TD TV images, remote manipulator tasks rendered possible by stereo TV, TD endoscopy based on alternating-frame technology, and advancements in computer-generated barrier-strip autostereography.

Merritt, John O.↗

Harnessing Artificial Intelligence for Medical Diagnosis and Treatment During Space Exploration Missions

BACKGROUND The medical capabilities necessary for long-duration exploration missions (LDEMs) will differ tremendously from those currently available to crew medical officers (CMOs) on the International Space Station (ISS). Ground support will be more challenging due to distance-related communication delays and data transmission, and resource utilization must be optimized given limited ability for resupply. Clinical decision support systems (CDSSs) can help mitigate these limitations. The recent launch of generative artificial intelligence (AI) tools based upon large language models (LLM) support the creation of a smart assistant for onboard triage, diagnosis, and guided treatment of medical conditions during these missions. The Informing Mission Planning via Analysis of Complex Tradespaces (IMPACT) tool can help predict which clinical problems and outcomes are likely to occur for a design reference mission (DRM) and assist Medical Operations and systems engineering teams in creating a medical system that may optimally mitigate the predicted risks. The purpose of this study was to identify AI tools currently available or in development for the assistive diagnosis and care of medical conditions predicted for an extended duration Lunar mission. METHODS The 119 medical conditions currently built into the IMPACT suite were categorized into systems, and these diagnoses were used as keywords for our literature search. Using PubMed and Google Scholar, we performed a literature survey of AI tools applicable to these conditions. Article inclusion criteria included publication between the years 2017-2023, as the sentinel paper discussing the “selective attention” driving ChatGPT and other generative transformer models was published in June 2017. Where applicable, we reviewed only the top 1000 research articles (based on relevance) for each of the keywords/phrases. AI tools whose training sets were exclusive to a pediatric patient population were excluded. We also excluded any medical diagnostic tools (such as CT, MRI, mass spectrometry) or procedures (such as endoscopy, surgery) that are unlikely to be available during LDEMs due to mass and volume constraints, CMO knowledge, skills, and abilities, and/or inherent procedural risks. RESULTS Our survey highlighted several AI-driven tools for the triage, diagnosis, and management of those medical conditions highlighted by IMPACT. Selected publications for each medical condition were then screened for inclusion within ten systems-based categories including: general diagnostic tools (25), tools to diagnose and manage respiratory (40), dermatologic (34), neurologic (28), auditory and vestibular (30), ophthalmic (34), musculoskeletal (104), infection-associated (92), and gynecologic (19) conditions, as well as tools that could be deployed in the setting of trauma and emergency (34). CONCLUSIONS Numerous AI-driven tools were highlighted within this literature survey, ranging from chatbot assistants that triage knee pain to vision transformer models for diagnosis of ophthalmic conditions using ocular surface images captured with a mobile phone. Remaining challenges include optimizing connectivity and integration of existing and developing systems into the vehicles or habitats. Notably, findings from this survey could help guide the initial design of an all-encompassing, onboard medical AI assistant for use during future LDEMs.

R A Lacinski↗

Development of a Testbed for Pipeline Flushing - 20425

Pipelines which carry high-level waste within the DOE complex should be properly flushed in the cases where stationary or moving beds of solid sediment occur, or lines are prone to hydrogen gas buildup. Present guidelines establish a minimum for the amount of water (flush volume) and flush velocity values used for post-transfer flushing operations to achieve satisfactory cleaning of pipelines. However, further studies are needed to find optimal operating velocity modes/values in order to minimizing the flush volume and consequent downstream waste. These efforts are significantly helpful to DOE waste remediation sites by preserving tank storage, preventing additional waste processing, and minimizing dilution and changes in waste chemistry. An experimental test loop was recently developed for study of non-Newtonian slurry flushing at the Florida International University (FIU). This loop was designed to create sediment beds of various materials and bed heights and investigate parameters that effect the efficiency of flushing operations. The objective is to find flush velocity values/modes which lead to satisfactory cleaning of transport lines with a minimum amount of water usage. A 165 ft experimental test loop made of 3-inch carbon steel pipes was constructed and used in initial testing campaigns. This pipe loop was equipped with real-time monitoring instruments to record variation of pressure, density, mass flow rate, and temperature during testing. Post-flush in-situ no-flow evaluations were performed using ultrasonic, endoscopy, and visual inspection. Additional post-flush evaluations were conducted using filtration and density monitoring of residuals within a designated circulations loop. These provisions enable comparison of pipeline cleanness before the start and after termination of flushing operations for efficiency evaluation. This paper presents efforts associated with flushing of kaolin-water mixtures at different concentrations and with various flush volume and flush velocity values/modes. In initial testing, efforts focused on creating repeatable sediment beds inside the pipeline in both fully-flooded (no pre-flush drainage) and gravity-drained (pre-flush drained) systems. Bed characterization (i.e., measurement of sediment height and solids concentration) was conducted to ensure about consistency of initial conditions between tests. Preliminary results for flushing study of 10% vol. kaolin-water mixtures starting from a fully-flooded initial condition showed that flushing with 1-line volume (65 gallons) could remove up to 72 percent of solids from the pipeline. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Endoscopic surgery and telemedicine in microgravity: developing contingency procedures for exploratory class spaceflight

OBJECTIVES: The risk of a urinary calculus during an extended duration mission into the reduced gravity environment of space is significant. For medical operations to develop a comprehensive strategy for the spaceflight stone risk, both preventive countermeasures and contingency management (CM) plans must be included. METHODS: A feasibility study was conducted to demonstrate the potential CM technique of endoscopic ureteral stenting with ultrasound guidance for the possible in-flight urinary calculus contingency. The procedure employed the International Space Station/Human Research Facility ultrasound unit for guide wire and stent localization, a flexible cystoscope for visual guidance, and banded, biocompatible soft ureteral stents to successfully stent porcine ureters bilaterally in zero gravity (0g). RESULTS: The study demonstrated that downlinked endoscopic surgical and ultrasound images obtained in 0g are comparable in quality to 1g images, and therefore are useful for diagnostic clinical utility via telemedicine transmission. CONCLUSIONS: In order to be successful, surgical procedures in 0g require excellent positional stability of the operating surgeon, assistant, and patient, relative to one another. The technological development of medical procedures for long-duration spaceflight contingencies may lead to improved terrestrial patient care methodology and subsequently reduced morbidity.

Parabolic Flight↗

3D Imaging with a Single-Aperture 3-mm Objective Lens: Concept, Fabrication and Test

There are many advantages to minimally invasive surgery (MIS). An endoscope is the optical system of choice by the surgeon for MIS. The smaller the incision or opening made to perform the surgery, the smaller the optical system needed. For minimally invasive neurological and skull base surgeries the openings are typically 10-mm in diameter (dime sized) or less. The largest outside diameter (OD) endoscope used is 4mm. A significant drawback to endoscopic MIS is that it only provides a monocular view of the surgical site thereby lacking depth information for the surgeon. A stereo view would provide the surgeon instantaneous depth information of the surroundings within the field of view, a significant advantage especially during brain surgery. Providing 3D imaging in an endoscopic objective lens system presents significant challenges because of the tight packaging constraints. This paper presents a promising new technique for endoscopic 3D imaging that uses a single lens system with complementary multi-bandpass filters (CMBFs), and describes the proof-of-concept demonstrations performed to date validating the technique. These demonstrations of the technique have utilized many commercial off-the-shelf (COTS) components including the ones used in the endoscope objective.

surgery↗