Influence of Pt-Metal Alloy Catalysts with Various Ionomers on Oxygen Reduction Reaction in Fuel Cell Application

Pt-M/C (M = Co, Ni, Mn, etc.) alloy catalysts exhibit superior oxygen reduction reaction (ORR) activity compared to pure Pt/C, leading to a high energy efficiency in hydrogen fuel cells. However, many Pt-M/C alloy catalysts were synthesized and evaluated at the lab scale in model test-bed systems like rotating disc electrodes, which don't always correlate to performance within a fuel cell system; there is a clear need to evaluate catalysts in electrodes that can be prepared at industrially relevant scales to evaluate how factors like ink formulation can greatly affect device-level of fuel cell performance. Herein, three commercial Pt-M/C alloy catalysts (two Pt-Co/C and one Pt-Ni/C) were comprehensively characterized by various techniques. The results show that the average particle sizes of the three catalysts are close to 5 nm; the atomic ratio of Pt/M is around 4; and the M was successfully embedded into Pt lattice, resulting in the positive shift of Pt 4f in XPS spectra and XRD patterns. These catalytic materials were incorporated into 9 different cathode catalyst layers (CCLs) with three kinds of ionomers (Nafion D2020, high oxygen permeability ionomer (HOPI), and Aquivion D79-25BS), and their performance in proton exchange membrane fuel cells (PEMFCs) were investigated. The results demonstrate that the Pt-Co/C catalysts possess a higher mass activity (MA) than Pt-Ni/C; the cathodes with Nafion ionomer provide the highest MA while electrodes with Aquivion ionomer showed the lowest activity, attributed to poor H+ conductivity resulting from suboptimal ionomer incorporation. Finally, these alloys were shown to exceed DOE targets for MA and H2/Air performance reported in the recent publications at beginning of life and after 90k cycle catalyst AST protocol. This study provides valuable performance benchmarks for these materials guiding future Pt-M/C catalyst design and material integration for heavy duty PEMFC applications.

08 HYDROGEN↗

Improving Cost and Efficiency of the Scalable Solid Oxide Fuel Cells Power System

The objective of this project was to design and develop a 20kW range small-scale solid oxide fuel cells (SOFC) power system for applications such as data centers and commercial buildings. The original plan included a 5,000 hours demonstration and a Techno-Economic Analysis (TEA) which were dropped as part of project termination. The original project plan was to use a stack with a cross-flow cell design which had previously been tested for 500 hours at a community college in Malta, NY. However, it was decided to move to the advanced R-SOFC co-flow cell developed under Department of Energy Award DE-FE0031971. The advanced cell design has the advantage of a larger active area for the same manufacturing footprint which results in fewer required cells for the same stack power, hence a higher volumetric power density (kW/L) and lower cost per kW than the original cross-flow cell design. A full SOFC system Simulink model was developed and calibrated with testing data from a fuel cell stack and BOP (balance of plant) components. The simulation results from the calibrated model showed an acceptable match with the experimental data. A structural analysis conducted for various load scenarios indicated no high stress areas for all spatial directions. Major electrical system components were acquired, built and successfully tested. System sensors were verified and validated against controls. Safety checks, a diagnostic check, PID tuning, and control software commissioning tasks were also conducted. The power electronics prototype was delivered and trial testing completed. Balance of Plant component testing and simulation work was conducted to characterize Reformer-Heat Exchanger heat transfer and backpressure and reformer catalyst methane conversion and product selectivity. Simulations were conducted to design the Anode and Cathode fluid passages and size the air-air and fuel-fuel heat exchangers. A Burner operation map was created from test data and the Anode Gas Recirculation blower was tested to evaluate its durability. The SOFC system used a horizontal style design where components sit directly on a casting with a direct connection to the skid. This design has efficient packaging and a small footprint with approximate dimensions of 750 mm x 700 mm x 1700 mm. An SOFC system was built and successfully tested at the Malta, NY facility The system for over 500 hours under load of which over 300 hours was at full load of 20 kW.

30 DIRECT ENERGY CONVERSION↗

A Data-Driven Method for Synthetic Extreme Weather Generation and Solar Impact Assessment: Preprint

High-resolution, high-fidelity weather datasets are essential for testing and evaluating the resilience of power systems, particularly under extreme weather conditions. However, existing extreme weather datasets are typically derived from historical events that are localized and may lack the spatial and temporal resolution or scenario diversity needed to test largescale power systems. In this work, we propose a synthetic extreme weather simulation approach capable of generating targeted extreme events, such as hurricanes, using publicly available data sources. Preliminary results demonstrate the impact of a simulated Category 1 hurricane on renewable generation and critical infrastructure in California. The work aims to provide a flexible approach for creating multiple types of extreme weather scenarios across different regions, enabling comprehensive system stress testing, training, and resilience assessment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization and Evaluation of Energy Savings for Connected and Autonomous Off-Road Vehicles

Off-road vehicles, such as wheel loaders, excavators, and harvesters, are extensively utilized across a wide range of industries, including construction, agriculture, and mining. These machines have become indispensable in supporting the day-to-day operational needs of a nation, playing a critical role in various sectors' infrastructure and productivity. However, despite their utility, off-road vehicles are significant consumers of fossil fuels, resulting in substantial emissions that contribute to environmental degradation. This highlights the pressing need for research and technological advancements aimed at improving their energy efficiency and reducing their carbon footprint. There are, however, two primary challenges that must be addressed to achieve these goals. First, off-road vehicles typically perform both driving and working tasks simultaneously, which introduces a high level of complexity into their overall dynamic systems. Analysis the interactions between these functions is challenging. Second, research into off-road vehicles is inherently interdisciplinary, demanding expertise across several domains such as fluid power systems, vehicle dynamics, control theory, optimization techniques, and real-world implementation. Recognizing these challenges, we proposed the project titled "Optimization and Evaluation of Energy Savings for Connected and Autonomous Off-Road Vehicles" as a comprehensive solution to enhance fuel efficiency while simultaneously improving productivity. This project specifically focuses on autonomous off-road vehicles, with particular attention to wheel loaders, and seeks to develop novel methods to optimize energy consumption without sacrificing operational performance. The project integrates real-time control algorithms, vehicle dynamics modeling, and co-optimization of powertrain system and vehicle system to achieve these goals. Our optimization strategy dynamically co-optimizes critical parameters at both the powertrain and vehicle levels, including vehicle speed, working tool movements, powertrain dynamics, and engine operations in real-time. To streamline this optimization process, we developed a vehicle model that captures the key dynamics while significantly enhancing computational efficiency. This allows the system to intelligently minimize fuel consumption, all while maintaining or even improving productivity through real-time calculations during various off-road operations. To validate the effectiveness of this energy optimization method, we introduced a state-of-the-art Hardware-in-the-Loop (HIL) testbed. This reconfigurable testbed seamlessly integrates the actual engine with virtual models of the wheel loader's subsystems, allowing for accurate emulation of real-world operational loads and environments. By simulating these conditions, the HIL testbed enables us to evaluate the wheel loader’s performance under diverse working scenarios, ensuring the developed solution is applicable in real-world operations. This testbed proved to be instrumental in validating the optimization algorithms and demonstrating the system's practical effectiveness. During the evaluation and testing phase, we employed the HIL testbed to rigorously assess the energy savings and productivity improvements generated by the optimized system. The results were highly encouraging, revealing that the automated wheel loader achieved over 30% fuel savings compared to traditional, human-operated cycles, with comparable or even enhanced levels of productivity. The insights gained from this HIL-based testing provided critical validation of our approach and highlighted the potential for deploying these optimized autonomous technologies in real-world off-road vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.

ASHRAE guideline 36↗

Cytrics Repository Of Analysis Tools And Engineering Resources

Cybersecurity Testing for Resilient Industrial Control Systems (CyTRICS) is a DOE-funded project that works with vendors to evaluate the cybersecurity of equipment used in US critical infrastructure. In the process of testing systems, CyTRICS researchers often develop custom tools. The tools in this repository were developed during multiple CyTRICS tests to assist with the testing process. They help solve problems encountered by CyTRICS researchers and address uncommon testing subjects for which limited tooling is available. They are useful to other researchers working on similar systems and architectures.

Laird, SutterE↗

Digital Grid Twin–Direct Communication Scheme Test Bed for Assessing Relay-to-Relay Radio Antenna and Optical Fiber Performance and Misoperations

This study introduces a novel “Digital Grid Twin–Direct Communication Scheme” test bed. This advanced platform evaluates point-to-point communication between transmitter and receiver relays with optical fiber and radio omnidirectional antenna systems, implemented at the Advanced Protection lab in the Grid Research Innovation and Development Center at Oak Ridge National Laboratory. The increased diversity of energy sources has led to more protective relay misoperations. In North America, microgrid protection schemes now use point-to-point communication along distribution lines between relays to implement advanced logic in nonradial grids that include both high- and low-inertia generators. This trend challenges utilities to minimize misoperations while ensuring rapid fault clearance and accurate selectivity coordination between primary and backup relays. This study assesses relay-to-relay communication schemes by introducing an advanced testing platform based on a digital grid twin protection test bed using a synchronized time source system. The platform evaluates the communication system using radio antennas or optical fiber links by integrating protective relays that operate breakers within the digital twin and record relay events and communication signals. In the experiments, transmitter and receiver relays were configured with inverse time overcurrent and breaker trip detection logic to assess the total time of the communication protection schemes based on the sum of the relay protection element operating time, radio latency, propagation delay, baud rate delay, and relay processing time. These delays were derived from recorded relay events and communication signals from the interface of a real-time simulator set as a digital grid twin. The test bed successfully simulated various electrical faults along a distribution line while ensuring effective and reliable point-to-point communication between transmitter and receiver relays. The radio antenna communication system exhibited latency because of the radio. This latency depends on the baud rate setting and type of radio application; in general, the higher the baud rate, the lower the radio latency. The measured radio latency (for Mirrored Bits with an encryption card at 9,600 bps) was about 9–10 ms. Additionally, calculated propagation delay per mile for radio antennas and optical fiber was 5.36 µs/mi and 8.04 µs/mi, respectively. Optical fiber communication did not demonstrate radio latency. Instead, the protection element operating time depends mainly on the protection logic function set in the relay, and the relay processing time depends on the processing rate of the relay in samples per power system cycle.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparing Tandem Cell Designs for Electrochemical CO 2 Reduction to Ethylene

Electrochemical carbon dioxide reduction (CO 2 R) is a promising approach for the decentralized production of fuels such as ethylene (C 2 H 4 ). However, the use of Cu, the most efficient metal CO 2 R catalyst for the generation of C 2 H 4 known to date, generally yields a product stream with poor selectivity. In an effort to increase selectivity, the reaction from CO 2 to C 2 H 4 can be broken down into two steps using tandem CO 2 R electrolyzers: formation of CO from CO 2 and subsequent reduction of CO to C 2 H 4 . Here, in this study, we present two novel tandem electrolyzer architectures that closely integrate two cathodes, one for CO generation and one for conversion to C 2 H 4 , while still enabling independent electrical control of the cathodic surfaces. Cathode segmentation in each of these designs also permits the controlled sequencing of mass flow of chemical intermediates in the order of Au to Cu cathode catalysts, in contrast to earlier work relying on uncontrolled, passive diffusion to facilitate the flow of chemical intermediates between catalysts. When comparing the performance of the newly developed electrolyzer cell designs with a dual electrolyzer system, we found that the dual electrolyzer system yields the highest C 2 H 4 faradaic efficiencies (FEs) of 31% and C 2 H 4 concentrations (∼8 mol %). However, a single Cu-containing electrolyzer outperformed all three tandem systems in terms of C 2 H 4 FE (34%). Our findings, enabled by independent control of the two tandem cathode surfaces, indicate that tandem CO 2 R systems need to be evaluated carefully by testing them at various relevant current densities.

C2H4↗

Recommendations for Comprehensive and Independent Evaluation of Machine Learning‐Based Earth System Models

Abstract Machine learning (ML) is a revolutionary technology with demonstrable applications across multiple disciplines. Within the Earth science community, ML has been most visible for weather forecasting, producing forecasts that rival modern physics‐based models. Given the importance of deepening our understanding and improving predictions of the Earth system on all time scales, efforts are now underway to develop Earth‐system models (ESMs) capable of representing all components of the coupled Earth system (or their aggregated behavior) and their response to external changes over long timescales. Building trust in ESMs is a much more difficult problem than for weather forecast models, not least because the model must represent the alternate (e.g., future or paleoclimatic) coupled states of the system for which there are no direct observations. Given that the physical principles that enable predictions about the response of the Earth system are often not explicitly coded in these ML‐based models, demonstrating the credibility of ML‐based ESMs thus requires us to build evidence of their consistency with the physical system. To this end, this paper puts forward five recommendations to enhance comprehensive, standardized, and independent evaluation of ML‐based ESMs to strengthen their credibility and promote their wider use.

54 ENVIRONMENTAL SCIENCES↗

A Distributionally Robust Optimization Framework for Stochastic Assessment of Power System Flexibility in Economic Dispatch

Given the complexity of power systems, particularly the high-dimensional variability of net loads, accurately depicting the entire operational range of net loads poses a challenge. To address this, recent methodologies have sought to gauge the maximum range of net load uncertainty across all buses. In this paper, we consider the stochastic nature of the net load and introduce a distributionally robust optimization framework that assesses system flexibility stochastically, accommodating a minimal extent of system violations. We verify the proposed method by solving the flexibility of the economic dispatch problem on four distinct IEEE standard test systems. Compared to traditional deterministic flexibility evaluations, our approach consistently yields less conservative flexibility outcomes.

distributionally robust optimization↗

Polar Bear™ – Innovative Capture of Storage Tank Vapors

Polar Bear™ is a patented technology developed by the Energy & Environmental Research Center (EERC) to capture storage tank vapors and eliminate methane emissions from upstream oil- and gas-producing facilities. Sparked by early commercial investment, the EERC licensed the technology and extended the intellectual property to storage tanks. Polar Bear™ is uniquely engineered and adapted to individual lower-producing facilities where there is otherwise no economic alternative for capturing tank vapors. A high number of small producing oil and gas wells are distributed across the country. The aggregate contributes to a significant volume of emissions. Because of the lack of economy of scale, gas volumes from these facilities are typically not recovered and contribute to methane emissions. Polar Bear™ provides a fit-for-purpose compression solution that addresses cost by reducing complexity with respect to conventional vapor recovery units and eliminating oil changes. Unique to Polar Bear™ is the capability to separate oxygenated gas from storage tank vapors. Storage tanks are designed to “breathe,” allowing gas to enter and escape during internal level and temperature changes. This infiltration of air into the tank headspace imparts undesirable oxygen content with respect to pipeline gathering. Polar Bear™ separates the vapor stream, allowing oxygen-rich gas to be used as fuel on-site while recovering the liquids-rich portion of the gas where oxygen content is minimized. A prototype system was tested to verify process models, evaluate operational performance, and advance the technology readiness level from 5 to 6. Results provide a good match between experimental measurements and process models, indicating the models are useful for future scale-up and field design. Various mixtures of nitrogen and liquefied petroleum gas were tested to understand the mass balance of nitrogen and how it relates to the potential control of oxygen content. Findings indicate that less than 2000 ppm of oxygen is likely to remain in the liquid portion of the gas in field applications. The research and development prepare the technology for field implementation to eliminate routine and fugitive methane emissions from storage tanks.

02 PETROLEUM↗

METHOD FOR EXPOSING IRRADIATED FUEL CLADDING TO RAPID THERMAL TRANSIENTS

Reactor core materials exposed to rapid thermal transients during accidents can experience significant changes in mechanical properties as irradiation hardness is recovered. Understanding material performance during transients using computer modeling requires accurate descriptions of mechanical property evolution with time and temperature. A simple experimental capability was developed to expose irradiated Zircaloy to a simulated thermal transient using immersion in molten tin (at 675°C) to rapidly heat and hold before rapidly cooling with a water quench. Multiple heating-cooling cycles using a nonirradiated tensile specimen showed simplicity and viability. Based on preliminary test results, a robust system was established for routine evaluation of simulated thermal accident scenarios in the Low Activation Materials Design and Analysis (LAMDA) laboratory at Oak Ridge National Laboratory (ORNL). This paper summarizes system development and nonirradiated Zircaloy commissioning test results. Future experiments will conduct tensile tests on irradiated Zircaloy after various rapid temperature profiles.

Byun, TS↗

High-throughput oxidation screening and down-selection of refractory high entropy alloys in the Al-Cr-Mo-Nb-Ta-Ti system

Rapid experimentation and characterization are ever-present needs in the discovery of high entropy alloys. High entropy alloy systems are difficult to survey with systematic composition sweeps using traditional synthesis methods. The number of distinct compositions in even a four-element system is experimentally intractable. Exploration of these, and higher-element systems, necessitates thermodynamic prediction coupled with an automated sample creation method and a rapid screening methodology to effectively down-select alloys with targeted properties. As a result, a high-throughput method for evaluating the oxidation performance of refractory high entropy alloys was developed and tested. The six-element system of aluminum, chromium, molybdenum, niobium, tantalum, and titanium was evaluated for single phase stability and short-duration oxidation resistance. Target compositions were initially determined via thermodynamic predictions of single-phase stability across a wide temperature range. A twenty-five-sample build plate was produced using directed energy deposition additive manufacturing. After fabrication, the twenty-five 1 cm 3 samples were heat treated and characterized for composition and phase identification. The build plate was exposed to a high temperature oxidizing environment at 1000 °C for three hours. After oxidation, the composition, morphology, and chemistry of the oxides formed were characterized. Of the twenty-five samples produced, nine exhibited a favorable oxidation response, from which a single-phase BCC alloy at a composition of Al 13 Cr 7 Mo 19 Nb 18 Ta 26 Ti 17 was identified as the alloy with the most protective oxidation coating with a thin, adherent oxide scale. Finally, the complete experimental down-selection—from machine setup to final alloy identification—required approximately 45 labor hours, demonstrating a rapid validation for alloy discovery.

Additive manufacturing↗

Designing reinforcement learning algorithms for building HVAC control: From experimental observation to simulation comparisons

Advanced supervisory-level control with reinforcement learning (RL) is regarded as a promising solution for HVAC systems to minimize energy consumption while maintaining thermal comfort and indoor air quality. However, most RL applications were conducted in the simulation environment rather than real-world HVAC systems. This paper developed a value-based RL controller termed Deep Q-Network (DQN) for a typical central HVAC system and evaluated its performance in a building test facility. By comparing DQN with a rule-based controller, the study not only demonstrated the cases where DQN could properly maintain indoor comfort but also discussed possible reasons why DQN failed in some other situations. Recognizing the limitations of value-based RL algorithms from the experimental tests, a simulation study was conducted to compare DQN with an alternative RL approach, an actor–critic algorithm termed Deep Deterministic Policy Gradient (DDPG). In scenarios with a relatively large action space, DDPG outperformed DQN by requiring fewer computational resources and achieving better thermal comfort, lower energy consumption, and more stable control actions. The findings suggest that the ability of DDPG to handle continuous control variables more effectively allows for faster convergence in training and more precise control in practice, which enhances the overall efficiency and reliability of the HVAC system.

Guo, Fangzhou↗

Experiment to Investigate the On-set of Transient Fission Gas Release Under Simulated LOCA Conditions

Continuing efforts to better understand the phenomenon of transient fission gas release in irradiated commercial light water reactor fuel undergoing a simulated loss of coolant accident (LOCA) will be discussed in this work. During heating associated with LOCA conditions there is an additional release of fission gas beyond what is typically released during steady state operation. The exact timing of this release could impact the cladding balloon and rupture as the LOCA progresses in an actual accident. Recent experiments performed on the upgraded Severe Accident Test Station at Oak Ridge National Laboratory have expanded the current assessment of transient fission gas release. This system evaluates fission gas release by sweeping fission gas out of the LOCA test furnace and into cryogenically cooled cold traps where radioactive noble gas fission products are measured by gamma spectrometry. Additionally, the sweep gas can be monitored by a gas mass spectrometer to provide additional data on noble gas release and changes in the sweep gas atmosphere during heating. Several different conditions have been evaluated that explored the response of irradiated fuel to different thermal ramp conditions and different overpressure conditions. This further confirmed the impact of an overpressure in suppressing transient fission gas release. Further experiments are planned to evaluate the on-set temperature of transient fission gas release under a known overpressure. This test will progressively step through different temperature conditions while maintaining hydrostatic pressure on the fuel that is representative of high burnup fuel conditions. The available results from this type of testing will be discussed. Post-test microscopy will be compared to other transient fission gas release and standard LOCA tests to further understand the microstructural source of transient fission gas release.

Harp, Jason [ORNL] (ORCID:0000000253458440)↗

Organic Rankine Cycle Integration and Optimization for High Efficiency CHP Genset Systems (Final Technical Report)

This project successfully advanced the integration of Organic Rankine Cycle (ORC) technology with reciprocating engine–based combined heat and power (CHP) systems to improve electrical efficiency, total CHP efficiency, and grid-responsive operation. Over three budget periods, the work progressed from high-temperature ORC component development and thermodynamic model validation to next-generation system design, working fluid transition, and techno-economic analysis. Key technical accomplishments include development and validation of a thermodynamic model capable of accurately predicting ORC performance across an expanded temperature and pressure envelope; successful identification and validation of low-global-warming-potential (GWP) working fluids—most notably R1233zd(E)—as viable replacements for R245fa; and demonstration of scalable ORC architectures suitable for integration with 1–20 MW class reciprocating engines. These advances enable flexible CHP configurations that can increase electrical output while maintaining high overall utilization of available thermal energy. The project also produced a clean-sheet design for a next-generation ORC system targeting substantially higher power output per unit, supported by detailed component selection, heat exchanger evaluation, and system-level modeling. Techno-economic analyses indicate that ORC-enabled flexible CHP systems can meet or exceed Department of Energy (DOE) efficiency targets while providing value to both facility operators and the electric grid.. Late-stage testing of the largest next-generation ORC prototype identified limitations related to pump net positive suction head (NPSH) requirements and condenser flooding under certain operating conditions. Although these issues constrained full validation of that configuration within the project timeframe, they provided clear and actionable design guidance for future system refinements. Importantly, validated modeling, smaller-scale testing, and working fluid evaluations confirmed the technical viability of the overall approach. In aggregate, this project met its core objectives by establishing validated design tools, de-risking key ORC technologies for CHP applications, and defining a credible pathway toward commercialization of flexible, high-efficiency CHP systems. The results form a strong foundation for continued development and deployment beyond the conclusion of the DOE-funded effort.

20 FOSSIL-FUELED POWER PLANTS↗