Search NASA⌕ Search

SEARCH · Search NASA

Results for “extended operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

CO 2 Electrolysis Using Metal-Supported Solid Oxide Cells with Infiltrated Pr 0.5 Sr 0.4 Mn 0.2 Fe 0.8 O 3-$δ$ Catalyst

Electrochemical conversion of CO 2 to CO is demonstrated with symmetric-structured metal supported solid oxide cells (MS-SOC). Perovskite Pr 0.5 Sr 0.4 Mn 0.2 Fe 0.8 O 3-δ (PSMF) and Pr 6 O 11 catalysts were infiltrated into the MS-SOC cathode and anode, using 3 cycles with firing at 850 °C and 8 cycles with firing at 800 °C, respectively. Upon reduction during operation, the perovskite PSMF was transformed to Ruddlesden–Popper structure with a highly efficient electrocatalytic activity. The impact of operating temperature (600–800 °C) and overpotential (0–1.8 V) on the CO 2 conversion was investigated. The highest CO 2 conversion of 57.2% was achieved at 750 °C and 1.8 V. During extended operation for 150 h at 750 °C and 1.2 V, a cell demonstrated relatively stable performance, with initial current density of 535 mA cm -2 and CO 2 conversion of 23%. Degradation mechanisms were studied by posttest characterization.

25 ENERGY STORAGE↗

Persistent Elevated Soot Emissions Induced by Clustered Stochastic Preignition Events

Stochastic Preignition (SPI) is an abnormal combustion phenomenon that can occur in spark-ignition engines particularly under high-load operation. SPI is characterized by uncontrolled initiation of combustion prior to spark discharge, an abnormal combustion process that can lead to severe knock events and significant engine damage. SPI has been associated with fuel properties, lubricant composition, and engine design and operation. Here, in this work, a single-cylinder test engine with a dry-sump oil system was utilized to study the SPI response of E10 and E25 fuels with a range of Reid Vapor Pressure (RVP). An automated test procedure was employed, consisting of ten square-waved load profile segments, with each segment composed of 5 min of low-load operation followed by 25 min of sustained high-load operation. These tests were replicated across multiple days of testing including a lubricant triple flush between tests, and an online Fuel in Oil diagnostic measurement. Exhaust particulate emissions were continuously measured by an AVL microsoot sensor (MSS). Elevated particulate matter emissions were observed to occur concurrently with SPI events as blooms of soot. Particularly after clustered events (i.e., multiple SPI cycles occurring within 10 consecutive engine cycles), high soot emissions were observed to persist over several days of sequential operation despite daily lubricant changes, a complete warm-up procedure, and sustained low-load operation between test segments. This result implies that the particulate emissions trends may be dominated by deposit-based effects, where higher load operation is needed to alter deposition and formation processes. The observed soot blooms were also found to correspond to a reduction in the engine fueling and the fuel engine oil dilution rate despite the engine exhaust remaining at stoichiometric exhaust operation. These observations suggest that post-SPI events, pathways for lubricant migration and consumption into the combustion chamber may occur until these pathways are closed from deposit formation or ring dynamics during extended operation. These observed sooting propensity persisted with all fuels tests, but a linear correlation was observed between the summation of soot and particulate matter index (PMI) value for each fuel as well as SPI events, proving that PMI is a crucial fuel property for reducing SPI.

Splitter, Derek [Oak Ridge National Laboratory (OR↗

Scrambling and operator entanglement in local non-Hermitian quantum systems

The breakdown of Lieb-Robinson bounds in local, non-Hermitian quantum systems opens up the possibility for a rich landscape of quantum many-body phenomenology. We elucidate this by studying information scrambling and quantum chaos in non-Hermitian variants of paradigmatic local quantum spin-chain models. We utilize a mixture of exact diagonalization and tensor network techniques for our numerical results and focus on three dynamical quantities: (i) out-of-time-ordered correlators (OTOCs), (ii) operator entanglement of the dynamics, and (iii) entanglement growth following a quench from product initial states. We show that while OTOCs fail to capture information scrambling in a simple, local, non-Hermitian transverse-field Ising model, the closely related operator entanglement is a robust measure of dynamical properties of interest. Moreover, we show that the short-time growth of operator entanglement can generically detect entanglement phase transitions in these systems while its long-time average is shown to be a reliable indicator of quantum chaos and entanglement phases. This allows us to extend operator entanglement-based diagnostics from previous works on closed and open quantum systems, to the new arena of monitored quantum dynamics. Finally, we remark on the efficacy of these dynamical quantities in detecting integrability/chaos in the presence of continuous monitoring.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Long wavelength interband cascade lasers

InAs-based interband cascade lasers (ICLs) can be more easily adapted toward long wavelength operation than their GaSb counterparts. Devices made from two recent ICL wafers with an advanced waveguide structure are reported, which demonstrate improved device performance in terms of reduced threshold current densities for ICLs near 11 μm or extended operating wavelength beyond 13 μm. Here, the ICLs near 11 μm yielded a significantly reduced continuous wave (cw) lasing threshold of 23 A/cm 2 at 80 K with substantially increased cw output power, compared with previously reported ICLs at similar wavelengths. ICLs made from the second wafer incorporated an innovative quantum well active region, comprised of InAsP layers, and lased in the pulsed-mode up to 120 K at 13.2 μm, which is the longest wavelength achieved for III–V interband lasers.

47 OTHER INSTRUMENTATION↗

Long-term durability test of highly efficient membrane electrode assemblies for anion exchange membrane seawater electrolyzers

Direct seawater electrolysis faces fundamental electrochemical challenges, such as suppression of chlorine adsorption and/or evolution reactions that poison the current state-of-the-art anode catalysts and accelerate the degradation of the anion exchange membrane (AEM). The technically favored solution path for addressing these issues includes development of novel selective catalysts and implementation of limited operating conditions. Therefore, development of highly active, selective, cost-effective, and stable seawater-splitting catalysts is required for a successful commercialization of the AEM water electrolyzers (AEMWEs). In this work, we report for the first-time an extended operation for over 1000 h of advanced AEMWEs, operating directly with seawater. To fabricate the membrane electrode assemblies (MEAs), catalyst coated electrodes (CCEs) are assembled with Sustainion® X37-50 grade T anion exchange membranes. The anode CCEs are fabricated by spraying an ink prepared from nanostructured NiFe-layered double hydroxide (LDH) catalyst that are synthesized by the solvothermal method and deposited directly onto platinized titanium porous transport layers (PTLs). The cathode CCEs are prepared by spraying an ink prepared from commercial Renay-Nickel catalyst onto a nickel fiber felt. As prepared AEM electrolyzer cells operated with seawater and demonstrated better than previously reported in the literature performance of over 1000 h of operation at a constant current density of 300 mA cm –2 .

25 ENERGY STORAGE↗

Planning for the storm: Considering renewable energy for critical infrastructure resilience

This study uses the renewable energy optimization model to assess three critical facilities in North Carolina. Techno-economic results were then compared to analyses completed for critical facilities in California and New York to assess energy system cost effectiveness. Though solar photovoltaic (PV) arrays are cost-effective across each of the three North Carolina facilities, adopting battery storage to enable PV to operate with existing diesel generators in a hybrid energy system reduces the economic value of the system. This is in contrast to more economically viable systems in California and New York. All of these systems also offer unquantified resilience benefits by extending operation from hours to weeks across the facilities. If decision makers were able to value the resilience benefits offered by each system or utility rate structures were changed to incentivize battery storage during normal operations, it would impact these assessments. Even so, this analysis provides decision makers a key set of cost benchmarks when considering how they might improve resilience at their critical operations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

VERA-Grizzly Ex-Core Calculations: Watts Bar Unit 1 Cycles 1-2

The critical structures that comprise light-water reactor (LWR) nuclear power plants are subjected to operating environments that can challenge their integrity. Structures in close proximity to the reactor core, such as the reactor pressure vessel (RPV) and the biological shield wall, are subjected to high levels of radiation emanating from the core, as well as elevated temperatures. As the US fleet of operating LWRs ages, the effects of these operating environments on the integrity of these structures must be considered to ensure their continued safe operation. Extending the lifetime of commercial reactors and maintaining the aging reactor fleet require accurate prediction of the exposure of ex-core components to neutron and photon radiation. In particular, concrete degradation studies must be performed to evaluate the safety and long-term operation of reactors with lifetime extensions. The concrete reactor bioshield is important for providing radiological protection during operation and must last for the entire lifetime of the reactor. Recent interest in lifetime extensions furthers the need to accurately simulate concrete material degradation in the reactor bioshield. As a result of this need, the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program has funded this study to couple its tools, Virtual Environment for Reactor Applications (VERA) and Grizzly. VERA allows users to set up models to calculate time-dependent and fully coupled solutions (with thermal feedback) for ex-core quantities of interest such as vessel and coupon fluence and detector responses for multiple statepoints and cycles. Grizzly is a finite-element application based on the Multiphysics Object Oriented Simulation Environment (MOOSE) framework that is used to enable aging materials calculations. This report highlights the work performed to calculate the fluence in the vessel and concrete for Watts Bar Nuclear Plant Unit 1 (WBN1) Cycles 1 and 2. The fluences obtained from VERA were successfully transferred to Grizzly using a Python script. Four simulations were run with Grizzly: (1) the Mazars model with the initial Young’s modulus being the instantaneous modulus, (2) the Mazars model with the initial Young’s modulus being the delayed modulus, (3) the Mazars model with the initial Young’s modulus being the delayed modulus with the addition of the effects of micro-damage caused by irradiation, and (4) the Mazars model with the initial Young’s modulus being the instantaneous modulus, and with the addition of micro-damage and creep. Details regarding the methods used to obtain the fluence and the statistical errors associated with the VERA Monte Carlo Shift calculations are discussed in greater detail in this report. The results obtained from the four Grizzly models are also presented in this report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design and Characterization of Highly Diffusive Turbine Vanes Suitable for Transonic Rotating Detonation Combustors

In rotating detonation engines the turbine inlet conditions may be transonic with unprecedented unsteady fluctuations. To ensure an acceptable engine performance, the turbine passages must be suited to these conditions. This article focuses on designing and characterizing highly diffusive turbine vanes to operate at any inlet Mach number up to Mach 1. First, the effect of pressure loss on the starting limit is presented. Afterward, a multi-objective optimization with steady RANS simulations, including the endwall and 3D vane design is performed. Compared to previous research, significant reductions in pressure loss and stator-induced rotor forcing are obtained, with an extended operating range and preserving high flow turning. Finally, the influence of the inlet boundary layer thickness on the vane performance is evaluated, inducing remarkable increases in pressure loss and downstream pressure distortion. Employing an optimization with a thicker inlet boundary layer, specific endwall design recommendations are found, providing a notable improvement in both objective functions.

Grasa, Sergio↗

Development of a Reconstruction Methodology Based on X-Ray Computed Tomography to Generate Realistic 3D Concrete Microstructures in MOSAIC

Despite being passive components, concrete structures represent a major capital investment in nuclear power plants. However, some concrete components are critical for the safety and long-term operation of the reactors: the concrete containment building protects the reactors from external aggression. The concrete biological shield (CBS) contains the radiation exiting the reactor to protect equipment and personnel. Depending on the design, the CBS also has a function for supporting the reactor’s systems. This function needs to be ensured in-service and during accident scenarios. After several decades of use, the CBS is exposed to high-energy irradiation over an extended operation time, exceeding the fluence level currently considered detrimental for the concrete’s structural properties. Such conditions occur at different times depending on the reactor’s operation and design. Nevertheless, from the perspective of subsequent license application, it is mandatory to assess the potential effects of prolonged irradiation on concrete. Unlike steel components, concrete structures are built with local constituents (cement, sand, and coarse aggregates) to avoid prohibitive transportation costs. Thus, concrete performance is determined by the tolerance or the susceptibility of its constituents against any aging mechanism. The tolerance against irradiation of the CBSs may vary greatly among the 56 nuclear power plants and 93 nuclear power reactors that form the current US light-water reactor fleet. Irradiation-induced degradation is mainly a result of amorphization-induced expansions of the silicated minerals present in the aggregates. The neutron irradiation–induced expansion varies from one rock-forming mineral to another: well framework–structured silicates (e.g., quartz and feldspars) exhibit higher swelling than chained (e.g., pyroxene) or isolated silicates (e.g., garnet). Silicates make up nearly 90% of the Earth’s crust. Other common minerals present in construction aggregates are carbonates found, for example, in limestone. Irradiated carbonates exhibit only very minor expansions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Elucidating the degradation mechanisms of Pt-free anode anion-exchange membrane fuel cells after durability testing

The development of anion-exchange membrane fuel cells (AEMFCs) has recently accelerated due to synergistic improvements yielding highly conductive membranes, stable ionomers, and enhanced alkaline electrocatalysts. However, cell durability, especially under realistic conditions, still poses a major challenge. Herein, we employ low-loadings of Pt-free Pd-based catalysts in the anode of AEMFCs and elucidate potential degradation mechanisms impacting long-term performance under conditions analogous to the real-world (high current density, H 2 –air (albeit CO 2 -free), and intermittent operation). Our high-performing AEMFCs achieve impressive performance with power densities approaching 1 W cm —2 and current densities up to 3.5 A cm —2 . Over a 200 h period of continuous operation in H 2 –air at a current density of 600 mA cm —2 , our model Pd/C–CeO 2 anode cell exhibits record stability (~30 μV h —1 degradation) compared to the literature and up to 6× better stability than our Pd/C and commercial Pt/C anode cells. Following an 8 h shutdown, the Pd/C–CeO 2 anode cell was restarted and continued for an additional 300 h with a higher degradation rate of ~600 μV h —1 . Thorough in situ evaluations and post-stability analyses provide insights into potential degradation mechanisms to be expected during extended operation under more realistic conditions and provide mitigation strategies to enable the widespread development of highly durable AEMFCs.

08 HYDROGEN↗

First DIII-D-West hybrid scenario similarity experiments for iter-relevant long-pulse operation

For the first time, similarity experiments between DIII-D and WEST were performed in the ITER "hybrid-like" regime during dedicated campaigns in April and May 2025. The matched parameters include elongation, triangularity, ion ∇B drift direction toward the X-point, qprofile, and core normalized physics quantities in terms of normalized pressure, normalized gyroradius, electron collisionality, ratio of ion to electron temperature, T i /T e . Core transport physics is explored with different aspect ratio (R/a) values (typically 3 at DIII-D and 5 on WEST). DIII-D explored high-beta conditions (electromagnetic effect) with low torque injection (~0 ± 0.5 N•m) using high heating power (up to 6 MW NBI and 2 MW ECRH powers), while scanning the heating mix (ion vs electron), beta, T i /T e , core radiation via controlled tungsten injection using the Laser Blow-Off system. WEST extended operation toward long-duration pulses using its actively cooled tungsten divertor, achieving dominated electron heating regimes with reduced tungsten contamination. Boron impurity injection were scanned on WEST to control edge conditions and core performance. It is found that core confinement improves-manifested by higher electron temperature, total energy content, neutron rate, and ion temperatureunder conditions of low separatrix density, consistent with previous observations [Bourdelle et al., Nucl. Fusion 63 (2023) 056021]. Conditions for Hmode access and for ion heating in electron-dominated regimes in both WEST and DIII-D will be discussed and compared. The ratio of the thermal energy confinement time (τ E ) to the volume-averaged electron-ion collisional heat exchange time (τ e-i ) is a key parameter to enhance ion heating and potentially facilitate H-mode access in electron-heated regimes. These first-of-a-kind coordinated DIII-D and WEST experiments provide a unique multi-machine dataset to validate predictive models and to optimize ITER hybrid-scenario performance under diverse core and edge conditions.

DIII-D↗

Extending Component Lifetime And Improving Inverter Reliability (ECLAIIR)

Inverter reliability remains one of the most persistent challenges limiting the performance, availability, and economic viability of utility‑scale photovoltaic (PV) plants. Industry data consistently show that inverters account for the highest share of corrective maintenance events and unplanned outages across PV fleets. These failures result in energy losses, increased O&M costs, and reduced confidence in long‑term solar asset performance. Motivated by these challenges, this project—Extending Component Lifetime and Improving Inverter Reliability (ECLAIIR)—was undertaken to systematically investigate inverter degradation and failure mechanisms, develop predictive maintenance capabilities, and establish data‑driven pathways to improve service life and reduce the Levelized Cost of Energy (LCOE) for large‑scale PV systems. The primary goal of the project was to identify pre‑failure signatures in string inverters using both lab‑based accelerated lifetime testing and field‑based data and to develop predictive maintenance algorithms that can anticipate inverter faults before they occur. Through collaboration with inverter testing laboratory, solar PV plant owner, and failure‑analysis experts, the project advanced the technical understanding of inverter reliability. By instrumenting inverters with thermistors, humidity sensors, power‑quality meters, and acoustic sensors, the research established how multiple sensing modalities can reliably detect deviations from normal behavior hours to days before failure. These findings substantially enhance scientific understanding of inverter failure kinetics and provide the PV industry with the most comprehensive cross‑OEM characterization of early‑stage failure indicators reported to date. Technically, the project demonstrated the effectiveness of predictive maintenance by developing and validating the PreDICT (Predictive Diagnostics of PV Inverters Using Condition Monitoring and Trend Analysis) framework—a multi‑layer diagnostic architecture combining peer‑to‑peer analytics, historical trend modeling, and advanced machine‑learning techniques such as the Sequential Conditional Variational Autoencoder (SCVAE). This predictive model achieved more than 90% accuracy in detecting pre‑failure conditions and provided up to four days of lead time before inverter failure in field scenarios. Economically, the project’s LCOE analysis showed that predictive maintenance can reduce lifetime energy losses and minimize corrective maintenance interventions. Modeling indicated that, depending on inverter failure rates and replacement timelines, predictive maintenance can significantly reduce LCOE impacts associated with inverter downtime: from as high as 19.4% under conventional maintenance strategies to 0.1%–10.17% when predictive analytics are adopted. These results confirm that predictive maintenance is both technically feasible and economically advantageous for utilities and plant operators. The project’s findings also have broad public benefit. By improving inverter reliability and reducing downtime, predictive maintenance directly increases electricity generation from existing PV assets. Enhanced reliability lowers operational costs for utilities, which can translate over time into lower energy costs for consumers. Furthermore, the project’s technical publications, conference presentations, and industry workshops ensure that knowledge gained is shared broadly across the solar industry, supporting workforce development and enabling utilities of all sizes to adopt modern asset‑health monitoring practices. The retrofitting case study and service‑life prediction framework further support informed decision‑making for aging PV fleets, helping operators extend system life and reduce electronic waste. In summary, the ECLAIIR project significantly advanced the state of knowledge on inverter degradation, demonstrated the technical and economic value of predictive maintenance, and delivered actionable tools and insights that support more reliable, cost‑effective, and sustainable PV plant operation. The outcomes of this project will continue to inform utility practices, guide inverter design improvements, and strengthen the long‑term performance of solar assets nationwide.

14 SOLAR ENERGY↗

Generalized global symmetries of T[ M ] theories. Part I

We study reductions of 6d theories on a d-dimensional manifold Md, focusing on the interplay between symmetries, anomalies, and dynamics of the resulting (6 – d)-dimensional theory T[M d ]. We refine and generalize the notion of “polarization” to polarization on Md, which serves to fix the spectrum of local and extended operators in T[M d ]. Another important feature of theories T[M d ] is that they often possess higher-group symmetries, such as 2-group and 3-group symmetries. We study the origin of such symmetries as well as physical implications including symmetry breaking and symmetry enhancement in the renormalization group flow. To better probe the IR physics, we also investigate the ’t Hooft anomaly of 5d Chern-Simons matter theories. The present paper focuses on developing the general framework as well as the special case of d = 0 and 1, while an upcoming paper will discuss the case of d = 2, 3 and 4.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Remarks on geometric engineering, symmetry TFTs and anomalies

Abstract Geometric engineering is a collection of tools developed to establish dictionaries between local singularities in string theory and (supersymmetric) quantum fields. Extended operators and defects, as well as their higher quantum numbers captured by topological symmetries, can be encoded within geometric engineering dictionaries. In this paper we revisit and clarify aspects of these techniques, with special emphasis on ’t Hooft anomalies, interpreted from the SymTFT perspective as obstructions to the existence of Neumann boundary conditions. These obstructions to gauging higher symmetries are captured via higher link correlators for the SymTFT on spheres. In this work, we give the geometric engineering counterpart of this construction in terms of higher links of topological membranes. We provide a consistency check in the context of 5D SCFTs with anomalous 1-form symmetries, where we give two independent derivations of the anomaly in terms of higher links, one purely field theoretical and the other purely geometrical. Along the way, we also recover the construction of non-invertible duality defects in 4D$$ \mathcal{N} $$ N = 4 SYM from a geometric engineering perspective.

Physics↗

Fermionic Finite-Group Gauge Theories and Interacting Symmetric/Crystalline Orders via Cobordisms

We formulate a family of spin Topological Quantum Field Theories (spin-TQFTs) as fermionic generalization of bosonic Dijkgraaf–Witten TQFTs. They are obtained by gauging G-equivariant invertible spin-TQFTs, or, in physics language, gauging the interacting fermionic Symmetry Protected Topological states (SPTs) with a finite group G symmetry. We use the fact that the torsion part of the classification is given by Pontryagin duals to spin-bordism groups of the classifying space BG. We also consider unoriented analogues, that is G-equivariant invertible pin ± -TQFTs (fermionic time-reversal-SPTs) and their gauging. We compute these groups for various examples of abelian G using Adams spectral sequence and describe all corresponding TQFTs via certain bordism invariants in 3, 4 and other dimensions. This gives explicit formulas for the partition functions of spin-TQFTs on closed manifolds with possible extended operators inserted. The results also provide explicit classification of ’t Hooft anomalies of fermionic QFTs with finite abelian group symmetries in one dimension lower. We construct new anomalous boundary spin-TQFTs (surface fermionic topological orders). Finally, we explore SPT and symmetry enriched topologically (SET) ordered states, and crystalline SPTs protected by space-group (e.g. translation Z) or point-group (e.g. reflection, inversion or rotation C m ) symmetries, via the layer-stacking construction.

97 MATHEMATICS AND COMPUTING↗

A hybrid porous model for full reactor core scale CFD investigation of a prismatic HTGR

Three-dimensional (3-D) Computational Fluid Dynamics (CFD) analysis of a whole nuclear reactor core is a tremendous challenge due to the large geometric volume and complex structures. Here, this research presents a hybrid porous (HP) model to simplify a prismatic High Temperature Gas-cooled Reactor (HTGR) core, so 3-D CFD investigation can be performed on a full reactor core scale. In the HP model, the prototypic small coolant channels in the nuclear fuel blocks are lumped together to form multiple equivalent large coolant channels, and then the porous medium flow model is applied to each of them. Therefore, heat transfer in fuel blocks is computed by a hybrid combination of solid energy and porous flow energy equations. The similarity between the HP model and prototypic model is achieved by deriving the porous flow permeability, inertial resistance factor, and artificial thermophysical properties. Compared with the widely used whole porous (WP) flow model, the HP model preserves more realistic geometric structures, and therefore more accurate physical processes. The General Atomics' Modular High Temperature Gas-cooled Reactor (MHTGR) design was chosen as a prototype to demonstrate the methodology. Simulations were performed using the prototypic CFD model and HP model at steady-state forced circulation, steady-state natural circulation, and transient conditions that correspond to normal operation, extended period of pressurized cool down, and short-term transients after reactor shutdown, respectively. The comparison shows good agreement between the HP model and prototypic model in the maximum fuel temperature, average solid temperature, and helium flow rate, which demonstrates the potential applicability of the HP model for a full reactor core scale simulation in the future. As a benefit, the HP model reduces the mesh quantity by a factor of 50 from a prototypic model. Correspondingly, the computation time was reduced by a factor of at least 30.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulated moving bed-inspired method for continuous adsorptive denitrogenation of model fuel

Efficient, continuous routes for removing nitrogen-containing compounds from hydrothermal liquefaction-derived synthetic aviation fuel are needed to enable direct blending with conventional jet fuels. Here, we report a simulated moving bed-inspired process for adsorptive denitrogenation of a model fuel. Unlike conventional simulated moving bed systems, which are designed for sharp separations between similar solutes, this approach was run deliberately outside the classical separation region so that both pyridine and indole were removed together from the hydrocarbon stream. Alcohol solvents were used to regenerate the silica adsorbent, maintaining performance over extended operation and avoiding the downtime and energy demand associated with calcination. Under these conditions, the system demonstrates removal of more than 98% of nitrogen while cutting solvent use by 28% compared to batch operation. Classical modeling tools predicted column concentration profiles even in this nontraditional regime, suggesting a straightforward path to scaling. Together, these results motivate solvent-efficient, continuous denitrogenation strategies that could be integrated with biorefinery processes.

Adsorption↗