Experimental investigation on heat transfer performance of drain water heat recovery heat exchangers

Water heating accounts for 18 % of residential energy consumption, and a substantial portion of this energy can be recovered through drain water heat recovery systems. Here, this paper investigates the heat transfer performance of drain water heat recovery heat exchangers. Two heat exchanger configurations were studied: vertical (gravity film exchanger) and horizontal. The heat recovery performance of the exchangers was quantified using sensible effectiveness and characteristic curves following the ε-NTU approach. Depending on the flow conditions, heat exchangers with a vertical configuration offered higher heat transfer effectiveness compared with the horizontal configuration under similar operating conditions. Furthermore, the results showed that properly designed and sized heat exchangers can effectively recover considerable amounts of waste heat from drains, depending on flow rates. Additionally, in the vertical heat exchanger configuration, low flow rates result in partially wet conditions, resulting in lower heat transfer effectiveness. Therefore, two distributor configurations are proposed to improve the heat transfer performance of vertically configured heat exchangers at low flow rates. The proposed distributor configurations and data presented in this paper will be useful in the design and development of drain water heat recovery systems in building applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Characterization of High-Surface Area Thermal Energy Storage

There is growing interest in energy storage technologies due to the expansion of renewable energy sources that are inherently intermittent and the increasing frequency of extreme weather events that disturb the power grid. Power consumption in buildings makes up approximately 76% of all electricity usage on the grid and is primarily used for thermal applications such as space conditioning, hot water, and cooking. This makes thermal energy storage (TES) an ideal solution for many of these applications. Many TES technologies rely on latent energy storage, which utilizes the melting/solidification of phase change materials (PCM) to store energy. Typically, TES designs suffer from low power density due to their low inherent thermal conductivity. This limitation makes the deployment of TES in active applications difficult as the ease of access to energy is essential for effective use. Common routes for improving power density include high thermal conductivity additives or extended features such as fins that increase cost. This study presents an alternative approach to improving performance through increasing the overall surface area to volume ratio of the device, to increase the available area for convection to occur between the working fluid and PCM. In the study a commercial PCM was selected with a transition temperature ideal for space heating applications. The heat exchanger design utilizes a unique application of triply periodic minimal surfaces (TPMS) for macro-encapsulation of the PCM. The use of TPMS for heat exchangers has been growing in interest due to their high-surface area to volume ratios, which were previously unmanufacturable until the development of additive manufacturing. A modular system was designed and manufactured with a stereolithography resin printing system that is then backfilled with PCM. An experiment test set-up is designed to test the charge and discharge performance of the thermal storage using a conditioned air stream. The pressure drop of the design is tested across a variety of flow rates. When compared to existing experimental data within literature, there is excellent agreement based on the Reynolds number at similar hydraulic diameters. Several inlet temperatures are tested at consistent temperature differences from the phase change temperature for both charging and discharging. Additionally, the volumetric flow rate is varied for each temperature set point. It was found that increasing flow rate had diminishing returns in reducing the overall charge time of the TES. The temperature delta from the melting temperature was the primary contributor to the change in average heat flux with limited variation in average heat transfer rate between charging and discharging at similar inlet temperatures and flow rates. The TPMS heat exchanger design has a high air-side pressure drop but it provides high heat transfer rates. This helps maintain a high outlet temperature during discharge, which is important to thermal comfort applications. The design, manufacturing, and experimental characterization of the TES device will be presented as part of this study.

25 ENERGY STORAGE↗

Experimental investigation of unsteady flow dynamics in therminol-66 using edge tone-induced oscillations

Recent research has demonstrated that flow oscillations induced by a wedge positioned opposite the jet outlet in edge tones can be effectively utilized for flow measurement purposes. This highlights the necessity for developing advanced instrumentation capable of precise flow measurements in experimental setups exposed to radiation and in challenging fluids such as molten salts. Here, this study contributes to the existing body of knowledge by conducting experiments using Therminol-66, an effective surrogate for FLiBe under appropriate temperature conditions for nuclear applications, across a broad range of Reynolds numbers from 17,700 to 555,000. Experiments were conducted with Therminol-66 at approximately 368.8 K under atmospheric pressure, with varying flow rates. A reliable correlation was established between the generated frequencies, corresponding flow rates, and device geometry parameters. The data were subjected to non-dimensional analysis to reveal the interrelationships among flow rate, fluid properties, device geometry, and their impact on the acoustic tones produced by the edge tone device. These findings contribute to the development of precise flow measurement instrumentation for use in challenging environments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Experimental characterization of a triply periodic minimal surface PCM-to-air thermal energy storage device

Here, the expansion of energy production has intensified research into thermal energy storage (TES) to manage variability and improve system efficiency. Heat exchanger design is critical to achieving high power densities in TES systems. This study presents a high-surface-area phase change material (PCM)-to-air heat exchanger fabricated via resin-based stereolithography with a novel gyroid-based geometry tailored for enhanced performance. Material properties of the commercial PCM and resin were characterized using analytical techniques. A controlled air loop was used to evaluate heat transfer and pressure drop at various flow rates and inlet temperatures. Results show a strong dependence on the inlet temperature difference (ΔT) relative to the PCM melting point. During charging at the highest flow rate, increasing the inlet air temperature from ΔT = 5 °C to 20 °C above the melting point increased the average heat transfer rate by 187%. During discharging, decreasing the inlet temperature by the same ΔT below the melting point led to a 232% increase. Notably, the high-surface-area design enabled nearly symmetric charging and discharging behavior, a novel result for PCM-based TES systems which are often restricted by natural convection and other effects. The overall heat transfer coefficient was calculated and compared to values from standard design correlations. The maximum thermal effectiveness reached 95% at ΔT = 20 °C and a moderate flow rate of 34 m 3 /h. Peak coefficients of performance (COP) of 7 during charging and 6.4 during discharging were observed at ΔT = 20 °C and a low flow rate of 20 m 3 /h. These results demonstrate the viability of additively manufactured geometries for advanced TES applications.

25 ENERGY STORAGE↗

Role of E × B Drift in Divertor Detachment Control via Boron Powder Injection on EAST

Here, the effects of B powder injection on plasma detachment about EAST discharge were studied by using SOLPS-ITER code package with the effects of E × B drifts considered. The simulation results show that plasma detachment occurs at the inner target in favourable toroidal magnetic field (B t ) direction at a relatively low B powder flow rate, one order of magnitude lower than that at the outer target. In a similar scenario with unfavourable B t , it is found that the detachment thresholds of B flow rate for both the inner and outer targets are close and of the same order as that for the outer target with favourable Bt. In favourable B t direction at B powder flow rate of 1.2 × 10 21 atoms/s, a localized, broadened high-density region is formed near the inner target benefitted by the injection location and the E × B drift, and a radiation-intensified zone, mostly contributed by B 1+ and B 2+ , occurs there. The E × B drift facilitates plasma detachment at the inner target and simultaneously amplifies the in–out divertor asymmetry. In addition, the simulation results with three different injection locations show that the injection from outer strike point leads to the lowest Z eff inside the separatrix and has an intermediate flow rate for detachment at the outer target, comparing with the X-point and upstream locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization and Experimental Validation of Annular Finned PCM-HX for a Domestic Hot Water Heater Application

The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.

42 ENGINEERING↗

Thermal Management of Discretized Heaters Using CuW Microchannel Heat Sinks and FC3283

Single-phase cooling using microchannel heat sinks (MCHS) has become a popular approach for overcoming the thermal challenges associated with high-powered microelectronic devices. Thermal management is one of the largest barriers to higher power densities in electronics and frequently limits overall device performance. The implementation of forced convective cooling via single-phase liquid cooling in MCHS reduces the thermal resistance resulting in lower device temperatures at high-power conditions, which can decrease the package size and extend the lifespan of devices. The goal of the work described in this article was to investigate practical cooling solutions for laser diode bars. This study examined the effectiveness of a copper tungsten (CuW) microchannel heat sink paired with a dielectric coolant (FC3283) for dissipating both discrete and uniform heat fluxes up to 600 W/cm2 across a 0.25-cm2 surface area through a numerical and experimental study. CuW was chosen as the MCHS material because it is thermal expansion matched to GaAs, which is a common laser diode substrate. FC3283 serves as a dielectric coolant that is compatible with power electronics cooling. The microchannels utilized in this work were approximately $365$ $μ$ m deep and $100$ $μ$ m wide resulting in a hydraulic diameter of $160$ $μ$ m. The study investigated the cooling performance across a variety of applied power loads and flow rates to determine optimal effectiveness. The resulting thermal resistance ranged from 0.15 cm2 K/W at the highest flow rate to 0.26 cm2 K/W at the lowest flow rate. Further, the resulting thermal performance from this study demonstrates the importance of considering discrete heat sources separately from uniform heat sources and proved that the unique combination of CuW microchannels with FC3283 can be a promising cooling option toward future advancements of laser diode bars and other high-power microelectronics.

42 ENGINEERING↗

Utilizing waste heat in wastewater treatment plants for water desalination: Modeling and Multi-Objective optimization of a Multi-Effect desalination system using Decision Tree Regression and Pelican optimization algorithm

This paper examines the feasibility of using waste heat from wastewater treatment plants (WWTPs) for water desalination. A model was developed to utilize waste heat from the gensets at As Samra WWTP in Jordan, using real data and TRNSYS® software to calculate available waste heat. The desalination process was then modeled with ASPEN PLUS® software, focusing on multi-effect desalination (MED). Both series and parallel configurations for the MED system were compared. The study investigated the effects of system feeding flow rate, feeding pressure, and heat input on productivity, performance ratio, and recovery ratio. The study also introduces a novel optimization technique combining machine learning and modern optimization algorithms to maximize system productivity and performance. Initially, a decision tree regression (DTR) model is developed to establish relationships between key independent variables (flow rate, feed pressure, and heat input) and dependent variables (productivity, performance ratio, and recovery ratio). The Pelican Optimization Algorithm (POA) is then used to identify the optimal values of the independent variables for maximum productivity and performance. The results show that using a series configuration yields a system productivity of 3984.2 kg/hr, a performance ratio of 3.78, and a recovery ratio of 0.991 at a feed flow rate of 4000 kg/hr, feed pressure of 3 bars, and heat input of 719 kW. Optimal productivity (4421 kg/hr), performance ratio (3.81), and recovery ratio (0.851) are achieved at a feed flow rate of 5166 kg/hr, feed pressure of 3.2 bars, and heat input of 794 kW. In conclusion, the techno-economic assessment indicates a levelized cost of water of 1.63 USD/m 3 for parallel configurations and 1.65 USD/m 3 for series configurations, with a payback period of less than two years.

42 ENGINEERING↗

LES simulations of a vacuum membrane distillation channel with geometric alterations

3D LES simulations were carried out to study the performance of a vacuum membrane distillation module. A wiggly wall profile with/without embedded stiffeners was considered to alleviate axial and radial temperature polarization, the cause of performance decrease in membrane distillation. Results of the flow field show the wiggles create unsteady vortex shedding inducing intense mixing in the channel. Vortex shedding intensity increases as the Reynolds number increases or stiffeners are added. 3D results show a 56% improvement in flux when moving from a flat sheet membrane to a wiggly membrane with stiffeners at a constant Reynolds number, corresponding to an improvement from 11.7 to 41.7 in the Nusselt number, showing that the alterations improved the flux performance by enhancing the heat transfer along the membrane surface and therefore alleviating temperature polarization, a critical bottleneck in membrane distillation systems. Further, a merit criterion was defined based on the Nusselt number and friction factor, and a 40% increase in merit was shown switching from a flat to a wiggly channel, while a 97% merit increase was seen going from flat to wiggly with stiffeners. A 42% enhancement in the flux was also seen moving from a straight channel to a wiggly channel at a higher Reynolds number which highlights the importance of strategically choosing the mass flow rate, as well as inducing flow separation and vortex shedding in the channel to promote mixing and dissipate the thermal boundary layer. The variation in results between the wiggly module with stiffeners and the wiggly module at high Reynolds numbers suggests enhancing mixing structures can be more impactful on flux for this geometry than increasing the flow rate to a turbulent/transitional regime. However, both are preferable for peak system flux performance. Furthermore, a 2D approximation was used to perform simulations on more extended channels to examine the length degradation. The modules with wiggly channels performed at the same flux level with a doubling of the length. On the other hand, the flat sheet modules experienced length degradation by temperature polarization and dropped in flux yield by around 13% of the short-channel value. This work illustrates that modeling the system and understanding how the performance decreases as the membrane surface area increases are critical for a larger module (scaling up from a lab to a prototype module) to maintain high flux performance.

42 ENGINEERING↗

Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation: Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental study of a tri-functional propane hydronic heat pump

This study investigates the performance of a propane hydronic heat pump system for space cooling, heating, and water heating applications, focusing on various operational conditions, with a total refrigerant charge below 1200 g. Cooling performance was evaluated at different outdoor temperatures, compressor stages (capacity levels), and water flow rates. The results showed that the coefficient of performance (COP) for cooling was higher at lower outdoor temperatures, with peak values exceeding 5.0 under low-stage operation and lower water flow rate. The cooling capacity increased with higher flow rates and compressor stages, reaching 12 kW. Space heating performance, evaluated at ambient temperatures ranging from −8.3 °C to 16.7 °C, revealed a decrease in COP with lower temperatures. However, high-stage operation maintained higher heating capacities even at low temperatures. The system demonstrated high Heating Seasonal Performance Factors (HSPF), exceeding 10.0. For water heating, the COP decreased with lower ambient temperatures and higher supply water temperatures. The system efficiently heated an 189-L water tank, outperforming conventional water heaters, with process COPs exceeding 4.0 under cooling-season conditions. Despite some efficiency loss due to defrosting at low temperatures, the propane heat pump consistently delivered strong performance. Seasonal energy efficiency ratios (SEER) and seasonal heating COP values indicated significant overall efficiency. The study concludes that propane is a promising refrigerant for heat pump systems, with future research needed to future reduce total system charge and optimize system performance through advanced controls and heat exchanger designs.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Window Cooling Studies and Disk Vibration Testing on a Subset of Mo-100 Disks

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless-steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process, with a smaller percentage adding up to 2.2 kW of heat deposited on the Inconel window. During irradiation, pressurized helium gas flows through thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo 100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. LANL has previously also tested NMR’s Inconel beam window by heating the window, while flowing pressurized helium, using the average heat deposited on the window. However, the NMR beam is pulsed with a duty cycle of 12.5%, which introduces oscillation in temperature around the nominal 600 °C steady state value with each pulse. Available fatigue curves for Inconel are few, established for room temperature, and they are based on mechanical strain cycles not thermally induced strain as in the NMR target. The effect of pulsed beam heating on the Inconel window therefore needs to be quantified. This report details the experiments conducted to assess the factors that lead to mass loss in the NMR target disks as well as to understand the effect of a pulsed beam on NMR’s Inconel window. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 5 to 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Improved target holders significantly reduce disk mass loss to almost negligible quantities. This work finds that the larger window to first disk gap and improved target holder geometry should allow NMR to successfully conduct irradiations with minimal mass loss. The window tests were conducted to understand the effect of a pulsed beam on both the window longevity and to estimate the window temperature and displacement during pulsing. The experiments presented here were performed at significantly low power, due to the limitations of the induction heating system. The window temperature rose to approximately 73 °C with a significantly reduced power of 45 W without beam pulsing. With a 5 Hz pulse rate, 12.5% duty cycle, the window temperature remained constant at 26 °C. These experiments will be repeated with improved coil geometry and reported in upcoming journal papers.

42 ENGINEERING↗

Parameter Study of the Running-In Process for the Generic Pebble Bed Reactor (GPBR200)

The run-in period of a pebble bed reactor is complex and difficult to model given significant heterogeneity in core composition, power, and temperature. While it is understood that the initial composition of the core should eventually result in the same equilibrium core composition, the approach to equilibrium can vary significantly depending on factors such as start-up fuel enrichment and power ramp rate. To explore this, a high-fidelity model of the General Pebble Bed Reactor was used to vary power ramp schemes and start-up core compositions. It was found that both the initial core composition and power ramp rate had a significant impact on the flow rate of pebbles during early time steps, with higher ramp rates and low enrichment resulting in non-physical flow rates. Power ramp rate alone was found to dictated maximum pebble power peaking observed during the run-in process, with higher ramp rates resulting in greater peak pebble powers. Start-up fuel enrichment and power ramp were found to both impact total fuel consumption, although the impact of start-up fuel enrichment was generally secondary to ramp rate.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Off-design operation and performance of pumped thermal energy storage

In this article, we describe off-design models and control strategies for a Pumped Thermal Energy Storage (PTES) system that uses liquid thermal energy storage: specifically molten salt for hot storage and methanol for cold storage. Off-design conditions arise when load-following, or due to variations in storage tank temperatures or ambient temperatures. We propose a control strategy that uses inventory control to manage the mass flow rate in the thermodynamic cycles, which facilitates load following. We also propose a control strategy for the storage fluid mass flow rates, which are varied to ensure the molten salt is maintained at its design temperature. This maximizes efficiency and minimizes problems with salt freezing or degradation. The cold storage fluid mass flow rate is varied so that the cold tanks have the same state-of-charge as the hot tanks. This leads to variations in cold fluid temperature, but these variations are shown to be acceptably small (e.g. 7.5% increase), and this control method is shown to be simpler and more efficient than an alternative strategy where tanks become unbalanced. The ambient temperature and storage tank temperatures are moved ±50 °C from the design values and the impact on power, duration, and tank temperatures is quantified. Results demonstrate that the proposed control strategy is stable and self-correcting - that is, storage temperatures converge on stable values after two-to-three charge-discharge cycles. When inputs return to design values, the system returns to its design point after two charge-discharge cycles. We also demonstrate that inventory control enables delivery of the target power output even when off-design conditions exist that would normally reduce the power output.

25 ENERGY STORAGE↗

CO2 hydrate crystal thickening, morphology, and Raman spectroscopy in a microfluidic device

Gas hydrates are a solid, crystalline form of water that often form at low temperatures and high pressures. Carbon dioxide (CO2) hydrates may form during carbon dioxide capture and storage (CCS) processes. These solid compounds may form in CO2 pipelines, potentially leading to a full blockage and process shutdown for plug removal. On the other hand, formation of CO2 hydrates may be desired for CO2 capture and separation. In either case, understanding the growth behavior and nature of the hydrates is vital to managing these CCS processes. Using a high-pressure, transparent microfluidic reactor, the crystalline film thickening of CO2 hydrates was observed and measured through visual microscopy and Raman spectroscopy. The impact of subcooling, pressure, and CO2 flow rate was investigated, and only CO2 flow rate was found to have a significant impact on the overall thickness of the film. Visual observations and Raman spectroscopy measurements confirmed that two distinct hydrate layers formed during thickening, one which was more porous than the other. The capillary-like channels in the porous layer indicated a mechanism for mass transfer of water through the hydrate layer. A model was developed based on this observation, and it was fit to the thickening data in order to obtain mass transfer coefficients. Results of this study can be applied to CO2 hydrate formation in pipelines and near porous media used for CO2 capture.

Wadsworth, Lindsey [Colorado School of Mines, Gold↗

Optimizing aluminum oxide passivation layers—Laser-induced plasmas for layer formation, real-time diagnostics, and layer evaluation

Molten salts have beneficial thermophysical and electrolytic properties, but the aggressive nature of molten salts requires corrosion mitigation strategies, such as structural material surface treatment. In this study, a laser-induced breakdown spectroscopy (LIBS) system was used to simultaneously ablate and monitor de-excitation spectra to form and identify dense alumina passivation layers. Additionally, high-frequency (kHz) LIBS imaging allowed rapid elemental mapping and depth profiling for surface O/Al ratios via minimally destructive analysis. The paired t-test rejected the null hypothesis that air and Ar cover gases were equivalent (p = 0.00012), and the analysis of variance (ANOVA) showed that overlap between shots (p = 0.03112) and cover gas flow rate (p = 0.02729) were statistically significant. At 75% overlap, the O/Al ratio increased to 10% ± 2%, and 90% overlap rose further to 31% ± 2%. Regardless of overlap, tuning the gas flow from 0.5 to 2.5 L min −1 enhanced the O/Al ratio by 24% ± 4%. LIBS depth profiling showed a 3× increase in layer thickness from 75% to 90% overlap. Molecular band peaks of AlO, a precursor to Al 2 O 3 found during treatment, suggest that band intensity could be used for real-time Al 2 O 3 optimization. Ultimately, by adjusting laser spot overlap and cover gas flow rate, a 266 nm laser was shown to form Al 2 O 3 layers on an Al6061 sample, with cover gas flow rate primarily affecting the O/Al ratio and layer thickness correlating with laser spot overlap. This combination of molecular spectra collection, imaging, and depth profiling demonstrated the robust layer analysis capabilities of LIBS.

Corrosion↗

Evaluation of flow-induced plate deflection for University of Missouri research reactor low-enriched uranium fuel element

The University of Missouri Research Reactor (MURR), located on the campus of the University of Missouri in Columbia, Missouri, is one of the six United States (U.S.) High Performance Research Reactors (USHPRR), including one critical facility, that are actively collaborating with the U.S. Department of Energy (DOE) National Nuclear Security Administration (NNSA) Office of Material Management and Minimization (M3) Reactor Conversion Program to convert from highly enriched uranium (HEU, ≥20 wt% U-235) fuel to low-enriched uranium (LEU, <20 wt% U-235) fuel. A new type of very high-density LEU fuel based on a monolithic alloy of uranium and 10 wt% molybdenum (U-10Mo) is expected to allow conversion of some USHPRR, including MURR. In the design of its fuel elements, MURR is using thin parallel curved fuel plates separated by coolant channels. In this work, fluid-structure interaction (FSI) analysis of the MURR LEU fuel element is performed at the element level (as compared to the plate level analysis), which models all components of the LEU fuel element, including fuel plates and the supporting structures. Therefore, the effect of supporting structures on the flow distribution within the element and the fuel plate deflection are evaluated. In addition to the element nominal flow rate and dimensions, the tolerances in the geometry of the coolant channel and plate thickness, the effect of a comb on plate deflection, and the uncertainty of the flow rate per element are evaluated. For the LEU fuel plates, which are thinner than the current HEU plates, the predicted plate deflection is found to be small compared to the fabrication and assembly tolerances. Thus, the FSI-induced deflections are not expected to noticeably reduce the coolant flow rate or predicted safety margins in the limiting channels for the MURR LEU fuel element. In addition to the simulation work, a hydraulic performance test of the MURR LEU fuel element is currently being planned to support conversion to the use of LEU fuel.