Search NASA⌕ Search

SEARCH · Search NASA

Results for “framing camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Advanced High-Speed Framing Camera Development for Fast, Visible Imaging Experiments

The advances in high-voltage switching developed in this project allow a camera user to rapidly vary the number of output frames from 1 to 25. A high-voltage, variable-amplitude pulse train shifts the deflection location to the new frame location during the interlude between frames, making multiple frame counts and locations possible. The final deflection circuit deflects to five different frame positions per axis, including the center position, making for a total of 25 frames. To create the preset voltages, electronically adjustable {+-}500 V power supplies were chosen. Digital-to-analog converters provide digital control of the supplies. The power supplies are clamped to {+-}400 V so as not to exceed the voltage ratings of the transistors. A field-programmable gated array (FPGA) receives the trigger signal and calculates the combination of plate voltages for each frame. The interframe time and number of frames are specified by the user, but are limited by the camera electronics. The variable-frame circuit shifts the plate voltages of the first frame to those of the second frame during the user-specified interframe time. Designed around an electrostatic image tube, a framing camera images the light present during each frame (at the photocathode) onto the tube’s phosphor. The phosphor persistence allows the camera to display multiple frames on the phosphor at one time. During this persistence, a CCD camera is triggered and the analog image is collected digitally. The tube functions by converting photons to electrons at the negatively charged photocathode. The electrons move quickly toward the more positive charge of the phosphor. Two sets of deflection plates skew the electron’s path in horizontal and vertical (x axis and y axis, respectively) directions. Hence, each frame’s electrons bombard the phosphor surface at a controlled location defined by the voltages on the deflection plates. To prevent the phosphor from being exposed between frames, the image tube is gated off between exposures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Design Yields Robust Large-Area Framing Camera

Manuscript to be submitted to Review of Scientific Instruments to determine interest in possible publication. Website: https://aip.scitation.org/rsi/authors/manuscript High-speed imaging is a core diagnostic capability for the Nevada National Security Site (NNSS). Data from experiments that measure the behavior of materials under extreme conditions are essential for the stockpile mission. For example, during subcritical experiments, materials that are shocked and compressed under high-explosive drive change behavior rapidly over timescales measured in millionths or even billionths of a second. Characterizing and understanding this behavior requires radiographic and/or optical imaging to track motion on these timescales. Framing cameras provide a discrete series of images over a short period of time in a manner that mimics a high-speed movie camera, but with individual shutter times that must be extremely short in order to capture freeze-frame images of rapidly evolving phenomena such as high-explosive shock-driven ejecta, dynamic compression of metals, and high-velocity fluid flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Colors and Photometry of Bright Materials on Vesta as Seen by the Dawn Framing Camera

The Dawn spacecraft has been in orbit around the asteroid Vesta since July, 2011. The on-board Framing Camera has acquired thousands of high-resolution images of the regolith-covered surface through one clear and seven narrow-band filters in the visible and near-IR wavelength range. It has observed bright and dark materials that have a range of reflectance that is unusually wide for an asteroid. Material brighter than average is predominantly found on crater walls, and in ejecta surrounding caters in the southern hemisphere. Most likely, the brightest material identified on the Vesta surface so far is located on the inside of a crater at 64.27deg S, 1.54deg . The apparent brightness of a regolith is influenced by factors such as particle size, mineralogical composition, and viewing geometry. As such, the presence of bright material can indicate differences in lithology and/or degree of space weathering. We retrieve the spectral and photometric properties of various bright terrains from false-color images acquired in the High Altitude Mapping Orbit (HAMO). We find that most bright material has a deeper 1-m pyroxene band than average. However, the aforementioned brightest material appears to have a 1-m band that is actually less deep, a result that awaits confirmation by the on-board VIR spectrometer. This site may harbor a class of material unique for Vesta. We discuss the implications of our spectral findings for the origin of bright materials.

Schroeder, S. E.↗

Synchronization of high speed framing camera and intense electron-beam accelerator

A new trigger program is proposed to realize the synchronization of high speed framing camera (HSFC) and intense electron-beam accelerator (IEBA). The trigger program which include light signal acquisition radiated from main switch of IEBA and signal processing circuit could provide a trigger signal with rise time of 17 ns and amplitude of about 5 V. First, the light signal was collected by an avalanche photodiode (APD) module, and the delay time between the output voltage of APD and load voltage of IEBA was tested, it was about 35 ns. Subsequently, the output voltage of APD was processed further by the signal processing circuit to obtain the trigger signal. At last, by combining the trigger program with an IEBA, the trigger program operated stably, and a delay time of 30 ns between the trigger signal of HSFC and output voltage of IEBA was obtained. Meanwhile, when surface flashover occurred at the high density polyethylene sample, the delay time between the trigger signal of HSFC and flashover current was up to 150 ns, which satisfied the need of synchronization of HSFC and IEBA. So the experiment results proved that the trigger program could compensate the time (called compensated time) of the trigger signal processing time and the inherent delay time of the HSFC.

43 PARTICLE ACCELERATORS↗

Overview of the ARGOS X-ray framing camera for Laser MegaJoule

Commissariat à l’Énergie Atomique et aux Énergies Alternatives has developed the ARGOS X-ray framing camera to perform two-dimensional, high-timing resolution imaging of an imploding target on the French high-power laser facility Laser MegaJoule. The main features of this camera are: a microchannel plate gated X-ray detector, a spring-loaded CCD camera that maintains proximity focus in any orientation, and electronics packages that provide remotely-selectable high-voltages to modify the exposure-time of the camera. These components are integrated into an “air-box” that protects them from the harsh environmental conditions. A miniaturized X-ray generator is also part of the device for in situ self-testing purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of neutron induced backgrounds in x-ray framing cameras

Fast neutrons from inertial confinement fusion implosions pose a severe background to conventional multichannel plate (MCP)-based x-ray framing cameras for deuterium-tritium yields >10{sup 13}. Nuclear reactions of neutrons in photosensitive elements (charge coupled device or film) cause some of the image noise. In addition, inelastic neutron collisions in the detector and nearby components create a large gamma pulse. The background from the resulting secondary charged particles is twofold: (1) production of light through the Cherenkov effect in optical components and by excitation of the MCP phosphor and (2) direct excitation of the photosensitive elements. We give theoretical estimates of the various contributions to the overall noise and present mitigation strategies for operating in high yield environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of heating laser injection time to imploded core plasma by using x-ray framing camera

A simultaneous measurement of imploded core plasma and injection time of heating laser is conducted by using an x-ray framing camera (XFC). The experiments are performed using Gekko XII laser system for implosion of the deuterated polystyrene (CD) plastic shell target and Peta Watt (PW) laser system for heating. The time of PW laser injection is observed as the bright zone in the XFC image. The measured x-ray intensity profiles fit the Gaussian profiles well. The calculations of microchannel plate by using dynode model explain these broadened temporal profiles qualitatively. The peak position of fitted x-ray intensity profile is almost in agreement with the time when the high energy x ray is observed by x-ray streak camera. Moreover, the peak position is delayed corresponding to the delayed setting of PW laser injection time. From these results, it is concluded that we can estimate the heating laser injection time with resolution of the order of 10 ps by using XFC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SEOS frame camera applications study

A research and development satellite is discussed which will provide opportunities for observation of transient phenomena that fall within the fixed viewing circle of the spacecraft. The evaluation of possible applications for frame cameras, for SEOS, are studied. The computed lens characteristics for each camera are listed.

Source record↗

4 Vesta in Color: High Resolution Mapping from Dawn Framing Camera Images

Rotational surface variations on asteroid 4 Vesta have been known from ground-based and HST observations, and they have been interpreted as evidence of compositional diversity. NASA s Dawn mission entered orbit around Vesta on July 16, 2011 for a year-long global characterization. The framing cameras (FC) onboard the Dawn spacecraft will image the asteroid in one clear (broad) and seven narrow band filters covering the wavelength range between 0.4-1.0 microns. We present color mapping results from the Dawn FC observations of Vesta obtained during Survey orbit (approx.3000 km) and High-Altitude Mapping Orbit (HAMO) (approx.950 km). Our aim is to create global color maps of Vesta using multi spectral FC images to identify the spatial extent of compositional units and link them with other available data sets to extract the basic mineralogy. While the VIR spectrometer onboard Dawn has higher spectral resolution (864 channels) allowing precise mineralogical assessment of Vesta s surface, the FC has three times higher spatial resolution in any given orbital phase. In an effort to extract maximum information from FC data we have developed algorithms using laboratory spectra of pyroxenes and HED meteorites to derive parameters associated with the 1-micron absorption band wing. These parameters will help map the global distribution of compositionally related units on Vesta s surface. Interpretation of these units will involve the integration of FC and VIR data.

Reddy, V.↗

Visualization of shocked material instabilities using a fast-framing camera and XFEL four-pulse train

Many questions regarding dynamic materials could be answered by using time-resolved ultra-fast imaging techniques to characterize the physical and chemical behavior of materials in extreme conditions and their evolution on the nanosecond scale. In this work, we perform multi-frame phase-contrast imaging (PCI) of micro-voids in low density polymers under laser-driven shock compression. At the Matter in Extreme Conditions (MEC) Instrument at the Linac Coherent Light Source (LCLS), we used a train of four x-ray free electron laser (XFEL) pulses to probe the evolution of the samples. To visualize the void and shock wave interaction, here, we deployed the Icarus V2 detector to record up to four XFEL pulses, separated by 1-3 nanoseconds. In this work, we image elastic waves interacting with the micro-voids at a pressure of several GPa. Monitoring how the material’s heterogeneities, like micro-voids, dictate its response to a compressive wave is important for benchmarking the performances of inertial confinement fusion energy materials. For the first time in a single sample, we have combined an ultrafast x-ray framing camera and four XFEL pulse train to create an ultrafast movie of micro-void evolution under laser-driven shock compression. Eventually, we hope this technique will resolve the material density as it evolves dynamically under laser shock compression.

fusion↗

One-dimensional space resolving flat-field holographic grating soft x-ray framing camera spectrograph for laser plasma diagnostics

A 1D space resolving x-ray spectrum diagnostic system has been developed to study the radiation opacity of hot plasma on SG-II laser facility. The diagnostic system consists of a 2400 lines/mm flat-field holographic grating and a gated microchannel plate coupled with an optical CCD and covers the wavelength range of 5-50 A. The holographic grating was compared with a ruled one by measuring the emission spectra from a laser-produced molybdenum plasma. The results indicate that the holographic grating possesses better sensitivity than the ruled grating having nearly similar spectral resolution. The spectrograph has been used in radiative opacity measurement of Fe plasma. Simultaneous measurements of the backlight source and the transmission spectrum in appointed time range in one shot have been accomplished successfully with the holographic grating spectrometer. The 2p-3d transition absorption of Fe plasma near 15.5A in has been observed clearly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗