Search NASA⌕ Search

SEARCH · Search NASA

Results for “functional performance testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Flight performance of the Skylab earth resources experiment package

The earth resources experiment package consisted of six facility-type sensors, which were flown on the Skylab spacecraft to collect data for a large group of investigators. For satisfactory interpretation of their data, many of these investigators required knowledge of the actual realized sensor performance, which may have differed from ground-based test performance. Functional, geometric, and radiometric evaluations of each sensor were made by using flight data from selected ground scenes, the moon, and dark space. As a result of these evaluations made during the Skylab missions, several sensor operation anomalies were identified and the appropriate corrective action was taken.

Potter, A. E.↗

Track/train dynamics test report transfer function test. Volume 1: Test

A description is presented of the transfer function test performed on an open hopper freight car loaded with 80 tons of coal. Test data and a post-test update of the requirements document and test procedure are presented. Included are a statement of the test objective, a description of the test configurations, test facilities, test methods, data acquisition/reduction operations, and a chronological test summary. An index to the data for the three test configurations (X, Y, and Z-axis tests) is presented along with test sequence, run number, test reference, and input parameters.

Vigil, R. A.↗

Qualification test results of IAPS 8 cm ion thrusters

Two 8-cm-diameter 5-mN mercury ion thrusters with associated beam shields and gimbals have been fabricated and qualification-tested for the Ion Auxiliary Propulsion System (IAPS) flight test. Functional and performance tests of the thrusters, conducted before, during and after exposure to protoflight vibration and thermal vacuum conditions demonstrated no effects of the environmental exposure and little performance dispersion between the thrusters.

Collett, C.↗

A low-cost, CCD solid state star tracker

Applied Research Corporation (ARC) has developed an engineering model of a multi-star CCD-based tracker for space applications requiring radiation hardness, high reliability and low power consumption. The engineering unit compared favorably in functional performance tests to the standard NASA single-star tracker. Characteristics of the ARC star tracker are: field of view = 10 deg x 7.5 deg, sensitivity range of -1 to +5 star magnitude, NEA = 3 in x 3 in, linearity = 5 in x 5 in, and power consumption of 1-3 W (operating mode dependent). The software is upgradable through a remote link. The hardware-limited acquisition rate is 1-5 Hz for stars of +2 to +5 magnitude and 10-30 Hz for -1 to +2 magnitude stars. Mechanical and electrical interfaces are identical to the standard NASA star tracker.

Chmielowski, M.↗

NASA Construction of Facilities Validation Processes - Total Building Commissioning (TBCx)

Key Atributes include: Total Quality Management (TQM) System that looks at all phases of a project. A team process that spans boundaries. A Commissioning Authority to lead the process. Commissioning requirements in contracts. Independent design review to verify compliance with Facility Project Requirements (FPR). Formal written Commissioning Plan with Documented Results. Functional performance testing (FPT) against the requirements document.

Hoover, Jay C.↗

Mission Overview and Status IGARSS Conference

The Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission is a strategic climate continuity mission that was defined in the 2010 document Responding to the Challenge of Climate and Environmental Change: NASA’s Plan for Climate-Centric Architecture for Earth Observations and Applications from Space (referred to as the “Climate Initiative”). Scheduled for launch in January 2024, the PACE mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records [1]. PACE will extend the high quality ocean ecological, ocean biogeochemical, cloud, and aerosol particle data records begun by NASA in the 1990s, building on the exceptional heritages of the Sea-Viewing Wide Field-of-View Sensor (SeaWiFS), the Moderate Resolution Imaging Spectroradiometer (MODIS), the Multi-angle Imaging SpectroRadiometer (MISR), and the Visible Infrared Imaging Radiometer Suite (VIIRS). The PACE project office at NASA’s GSFC is responsible for the satellite development, launch and operations. The NASA Headquarters PACE Program Science office is responsible for supporting the science data processing system and assembling competed community science teams, which will include field-based vicarious calibration and data product validation efforts to support the PACE Project Science team. The mission is planned for launch into a Sun synchronous polar orbit at 676.5 km with an inclination of 98 degrees and a 1 pm local ascending node crossing time. The PACE observatory is comprised of three instruments, an Ocean Color Instrument (OCI) and two polarimeters, the Hyper-Angular Rainbow Polarimeter 2 (HARP2) and the Spectro-Polarimeter for Exploration (SPEXone). The OCI is the primary instrument on the observatory and is being developed at Goddard Space Flight Center (GSFC). The OCI is a hyperspectral scanning radiometer designed to measure spectral radiances from the ultraviolet to shortwave infrared (SWIR) to enable advanced ocean color and heritage cloud and atmospheric aerosol science [2]. The HARP2 and SPEXone are complimentary instruments on the PACE observatory, acquired outside of GSFC. The HARP2 is multi-spectral, wide swath (supporting atmospheric correction of OCI), and hyper-angular, with capabilities for cloud science that exceed what is capable from OCI alone. The SPEXone is narrow swath, multi-angular, and hyperspectral, with capabilities for atmospheric aerosol science that exceed what can be accomplished with OCI. NASA Headquarters directed the mission development to be guided by a Design-to-Cost (DTC) process. All elements of the mission, other than the cost, are in the DTC trade space. At the heart of the DTC process are the mission studies, performed across all the mission elements. The mission studies were used to define appropriate approaches within and across elements while maximizing science capabilities at a high cost confidence. Mission baseline requirements development is also embedded within the DTC process, as these requirements were not established at the onset of the mission concept development. Baseline mission requirements are a product of the mission studies and are defined by the project office as part of the DTC process. At the time of this writing, OCI, HARP2 and SPEXone are integrated onto the PACE spacecraft, creating the PACE observatory. The instruments and spacecraft subsystems are undergoing combined functional performance testing in preparation for observatory-level environmental testing prior to shipment to the launch site. Here, we will provide an update on science capabilities and observatory readiness for its early 2024 launch.

remote sensing↗

Ensuring Safe Decision-Making on the Moon and Mars: Cognitive Performance Assessment for Exploration Class Mission EVA

Extravehicular activity (EVA) is one of the most dangerous and cognitively demanding actions that astronauts can execute, and the cognitive demands associated with future partial gravity EVAs on the Moon and Mars are expected to be higher compared to microgravity EVAs currently conducted from the International Space Station. Decrements in cognitive performance present an important risk to crew safety during exploration mission class EVA. Yet there is currently insufficient data to characterize cognitive performance prior to, during, and following EVA. Furthermore, it is still unclear which cognitive domains are most important for conducting mission critical decisions with crew safety implications. To address this gap, we conducted a cognitive task analysis (CTA) of EVA to characterize the procedures, the cognitive demands required, and the critical safety decisions associated with decrements in cognitive performance. We conducted a cognitive task analysis with 15 astronauts and subject matter experts in EVA operations and research. Interviews focused on surface exploration EVA and elicited feedback from experts on the cognitive skills required for specific EVA tasks, including cognitive strategies, critical cues, and decision-making strategies. A cognitive demands table was assembled to consolidate and synthesize the information from all interviews. The information from this cognitive task analysis informs ongoing exploration EVA for Moon to Mars. This work identifies the specific cognitive challenges that astronauts are likely to encounter during surface exploration EVA, and provides the foundation for: (1) prioritized and targeted cognitive performance measurement and functional performance tests, (2) EVA simulation design at varying levels of cognitive workload, and (3) the development of training and other technologies that can improve safe decision-making and inform EVA planning on future spaceflight missions to the Moon and Mars.

Steven R Anderson↗

Final Report for the Advanced Camera for Surveys (ACS) from Ball Aerospace and Technologies Corporation

The Advanced Camera for Surveys ACS was launched aboard the Space Shuttle Columbia just before dawn on March 1, 2002. After successfully docking with the Hubble Space Telescope (HST), several components were replaced. One of the components was the Advanced Camera for Surveys built by Ball Aerospace & Technologies Corp. (BATC) in Boulder, Colorado. Over the life of the HST contract at BATC hundreds of employees had the pleasure of working on the concept, design, fabrication, assembly and test of ACS. Those employees thank NASA - Goddard Space Flight Center and the science team at Johns Hopkins University (JHU) for the opportunity to participate in building a great science instrument for HST. After installation in HST a mini-functional test was performed and later a complete functional test. ACS performed well and has continued performing well since then. One of the greatest rewards for the BATC employees is a satisfied science team. Following is an excerpt from the JHU final report, "The foremost promise of ACS was to increase Hubble's capability for surveys in the near infrared by a factor of 10. That promise was kept. "

Volmer, Paul↗

Representation of the Physiological Factors Contributing to Postflight Changes in Functional Performance Using Motion Analysis Software

Astronauts experience changes in multiple physiological systems due to exposure to the microgravity conditions of space flight. To understand how changes in physiological function influence functional performance, a testing procedure has been developed that evaluates both astronaut postflight functional performance and related physiological changes. Astronauts complete seven functional and physiological tests. The objective of this project is to use motion tracking and digitizing software to visually display the postflight decrement in the functional performance of the astronauts. The motion analysis software will be used to digitize astronaut data videos into stick figure videos to represent the astronauts as they perform the Functional Tasks Tests. This project will benefit NASA by allowing NASA scientists to present data of their neurological studies without revealing the identities of the astronauts.

Parks, Kelsey↗

Countermeasures for Mitigation of Sensorimotor Decrements Following Head-Down Bed Rest

BACKGROUND Decrements in functional performance of tasks requiring postural and locomotor control remain common among crewmembers returning to Earth after6months on the International Space Station (ISS). These impairments will presumably be exacerbated after longer exploration-class missions with fewer exercise hardware options. Our recent studies suggest that an in-flight proprioceptive countermeasure may keep the proprioceptive system tuned to respond to upright balance challenges in a gravitational environment. Before testing a proprioceptive countermeasure in-flight, we must conduct an initial proof-of-concept study to determine its potential efficacy in a controlled unloading analog setting. OBJECTIVES We will determine if proprioceptive training during 60 days of 6° head down bed rest (HDBR) mitigates declines in functional task performance. We consider it critical to characterize the interaction between proprioceptive training and exercise. Thus, we will compare 3groupsof subjects(N=12 each): a proprioceptive training group, an exercise plus proprioceptive training group, and a control group(i.e. no training or exercise).The primary outcome measure will be the well-established and operationally relevant seat egress and walk test (also referred to as the functional mobility test)performed before and after HDBR. Other functional tests will also represent high priority exploration mission tasks that require high demand for dynamic control of postural stability. Additional measures will be used to identify the key physiological factors contributing to countermeasure benefits. COUNTERMEASURE METHODS We will use a ground version of our countermeasure to test the efficacy of proprioceptive training while maintaining HDBR constraints. Subjects will remain in the horizontal supine position on a sled that moves freely on air-bearings, similar to a puck on an air hockey table. Subjects will be loaded axially up to one full body weight via lateral cable pulleys towards their feet on an instrumented tilt board using a harness and weights system. Visual feedback of board tilt will be used to guide subjects while they make active tilts. Exercise and proprioceptive training prescriptions will represent those expected to be implemented during exploration spaceflight missions(e.g.20-minute proprioceptive training sessions3 times per week). RELEVANCE The deliverable from this project will be a proof-of-concept countermeasure design that has been fully assessed for efficacy in a spaceflight analog. The findings and lessons learned from this study will be translated for validation of this countermeasure on the ISS. An effective countermeasure will be added to the suite of operationally implemented in-flight sensorimotor countermeasures.

T R Macaulay↗

Treadmill Exercise with Increased Body Loading Enhances Post Flight Functional Performance

The goals of the Functional Task Test (FTT) study were to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. Ultimately this information will be used to assess performance risks and inform the design of countermeasures for exploration class missions. We have previously shown that for Shuttle, ISS and bed rest subjects functional tasks requiring a greater demand for dynamic control of postural equilibrium (i.e. fall recovery, seat egress/obstacle avoidance during walking, object translation, jump down) showed the greatest decrement in performance. Functional tests with reduced requirements for postural stability (i.e. hatch opening, ladder climb, manual manipulation of objects and tool use) showed little reduction in performance. These changes in functional performance were paralleled by similar decrements in sensorimotor tests designed to specifically assess postural equilibrium and dynamic gait control. The bed rest analog allows us to investigate the impact of axial body unloading in isolation on both functional tasks and on the underlying physiological factors that lead to decrements in performance and then compare them with the results obtained in our space flight study. These results indicate that body support unloading experienced during space flight plays a central role in postflight alteration of functional task performance. Given the importance of body-support loading we set out to determine if there is a relationship between the load experienced during inflight treadmill exercise (produced by a harness and bungee system) and postflight functional performance. ISS crewmembers (n=13) were tested using the FTT protocol before and after 6 months in space. Crewmembers were tested three times before flight, and on 1, 6, and 30 days after landing. To determine how differences in body-support loading experienced during inflight treadmill exercise impacts postflight functional performance, the loading history for each subject during inflight treadmill (T2) exercise was correlated with postflight measures of performance. Crewmembers who walked on the treadmill with higher pull-down loads had less decrement in postflight postural stability and dynamic locomotor control than those subjects who exercised with lighter loads. These data point to the importance of providing significant body loading during inflight treadmill exercise. This and the addition of specific balance training may further mitigate decrements in critical mission tasks that require dynamic postural stability and mobility. Inflight treadmill exercise provides a multi-disciplinary platform to provide sensorimotor, aerobic and bone mechanical stimuli benefits. Forward work will focus on the development of an inflight training system that will integrate aerobic, resistive and balance training modalities into a single interdisciplinary countermeasure system for exploration class missions.

Bloomberg, J. J.↗

Pre-Installation Acceptance (PIA) Functional Performance of the Design Verification Test (DVT) Exploration Extra-vehicular Mobility Unit (xEMU)

In an effort that began with technology investment by NASA in a few key components during the Constellation Program and then evolved to demonstrate a packaged Portable Life Support System (PLSS) as part of the Advanced Exploration Systems (AES) Program, the next evolution of the PLSS is now a key component of the Exploration Extra-vehicular Mobility Unit (xEMU) and is assembled as a Design Verification Test (DVT) unit. The xEMU has been detailed with respect to completing a demonstration on the International Space Station (ISS) with support of units for initial lunar capability. The xEMU completed the Preliminary Design Review (PDR) with subsequent Safety Review Panel (SRP) Phase I reviews in 2019-2020. The objectives for DVT are to validate requirements, train the team, learn how to fabricate the hardware with appropriate process controls, assemble the hardware, test the hardware, determine the failure mechanisms/limits of the hardware design and buy down the most risk possible for the qualification and flight phases of the development. With completion of the assembly and initial functional testing of the DVT PLSS in laboratory ambient conditions and vacuum conditions the xEMU has progressed significantly into the DVT objectives. A key part of the test sequences for DVT and all future phases is the Pre-Installation Acceptance (PIA) functional testing which validates the performance of integrated systems including: primary thermal control, auxiliary thermal control, suit ventilation, primary oxygen, secondary oxygen, power distribution, as well as caution and warning all with respect to the applied requirements. This discussion will include an overview of the assembly, summary of the PIA functional testing, lessons learned, and corrective actions implemented moving forward into the remainder of the DVT phase for xEMU.

Colin Campbell↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation: Preprint

Existing real-world projects of GFM inverters that operate in parallel to power grids typically are sized between dozens and a few hundreds Megawatt (MW) scale according to a recent NERC GFM inverter white paper. These large systems are often difficult to evaluate prior to deployments because of their large size. The performance of smaller GFM inverters (dozens to a few hundreds MW) that operate parallel with power grids (distribution systems) is even less understood. There is an opportunity to better understand these systems through hardware testing under controlled laboratory conditions. Therefore, this paper presents the functional performance evaluation tests of multiple (three) commercial GFM inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore the GFM inverters' functionalities and dynamic response when in parallel with power grids to eventually develop universal specifications for GFM inverters. Both steady state (changing the inverter's frequency and voltage droop) and transient (adding step change in grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The experimental results indicate the bench-marked performance that: 1) the GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power when paralleled to the grid; 2) the GFM inverters automatically respond to system frequency and voltage events to output the needed power, however, the GFM inverters all show stability issues when absorbing reactive power from the grid.

grid-forming inverters↗

Assessment of Postflight Locomotor Performance Utilizing a Test of Functional Mobility: Strategic and Adaptive Responses

Space flight induces adaptive modification in sensorimotor function, allowing crewmembers to operate in the unique microgravity environment. This adaptive state, however, is inappropriate for a terrestrial environment. During a re-adaptation period upon their return to Earth, crewmembers experience alterations in sensorimotor function, causing various disturbances in perception, spatial orientation, posture, gait, and eye-head coordination. Following long duration space flight, sensorimotor dysfunction would prevent or extend the time required to make an emergency egress from the vehicle; compromising crew safety and mission objectives. We are investigating two types of motor learning that may interact with each other and influence a crewmember's ability to re-adapt to Earth's gravity environment. In strategic learning, crewmembers make rapid modifications in their motor control strategy emphasizing error reduction. This type of learning may be critical during the first minutes and hours after landing. In adaptive learning, long-term plastic transformations occur, involving morphological changes and synaptic modification. In recent literature these two behavioral components have been associated with separate brain structures that control the execution of motor strategies: the strategic component was linked to the posterior parietal cortex and the adaptive component was linked to the cerebellum (Pisella, et al. 2004). The goal of this paper was to demonstrate the relative contributions of the strategic and adaptive components to the re-adaptation process in locomotor control after long duration space flight missions on the International Space Station (ISS). The Functional Mobility Test (FMT) was developed to assess crewmember s ability to ambulate postflight from an operational and functional perspective. Sixteen crewmembers were tested preflight (3 sessions) and postflight (days 1, 2, 4, 7, 25) following a long duration space flight (approx 6 months) on the ISS. We have further analyzed the FMT data to characterize strategic and adaptive components during the postflight readaptation period. Crewmembers walked at a preferred pace through an obstacle course set up on a base of 10 cm thick medium density foam (Sunmate Foam, Dynamic Systems, Inc., Leicester, NC). The 6.0m X 4.0m course consisted of several pylons made of foam; a Styrofoam barrier 46.0cm high that crewmembers stepped over; and a portal constructed of two Styrofoam blocks, each 31cm high, with a horizontal bar covered by foam and suspended from the ceiling which was adjusted to the height of the crewmember s shoulder. The portal required crewmembers to bend at the waist and step over a barrier simultaneously. All obstacles were lightweight, soft and easily knocked over. Crewmembers were instructed to walk through the course as quickly and as safely as possible without touching any of the objects on the course. This task was performed three times in the clockwise direction and three times in the counterclockwise direction that was randomly chosen. The dependent measures for each trial were: time to complete the course (seconds) and the number of obstacles touched or knocked down. For each crewmember, the time to complete each FMT trial from postflight days 1, 2, 4, 7 and 25 were further analyzed. A single logarithmic curve using a least squares calculation was fit through these data to produce a single comprehensive curve (macro). This macro curve composed of data spanning 25 days, illustrates the re-adaptive learning function over the longer time scale term. Additionally, logarithmic curves were fit to the 6 data trials within each individual post flight test day to produce 5 separate daily curves. These micro curves, produced from data obtained over the course of minutes, illustrates the strategic learning function exhibited over a relative shorter time scale. The macro curve for all subjects exhibited adaptive motor learning patterns over the 25 day period. Howev, 9/16 crewmembers exhibited significant strategic motor learning patterns in their micro curves, as defined by m > 1 in the equation of the line y=m*LN(x) +b. These data indicate that postflight recovery in locomotor function involves both strategic and adaptive mechanisms. Future countermeasures will be designed to enhance both recovery processes.

Warren, L. E.↗

Fluid infusion system

Performance testing carried out in the development of the prototype zero-g fluid infusion system is described and summarized. Engineering tests were performed in the course of development, both on the original breadboard device and on the prototype system. This testing was aimed at establishing baseline system performance parameters and facilitating improvements. Acceptance testing was then performed on the prototype system to verify functional performance. Acceptance testing included a demonstration of the fluid infusion system on a laboratory animal.

Source record↗

Preliminary Results Using Galvanic Vestibular Reduction as a Non-Pharmaceutical Tool for Motion Sickness Mitigation

Introduction: Alterations in vestibular sensory processing following G-transitions lead to motion sickness and spatial disorientation upon return to Earth’s gravity. The use of non-pharmaceutical mitigation for motion sickness has several potential advantages over drug treatment options. The purpose of this study was to validate a non-pharmaceutical tool using galvanic vestibular reduction (GVR) to mitigate G-transitional induced motion sickness and spatial disorientation. Methods: Using a repeated measures counter-balanced design, motion sickness and perception are obtained during Coriolis cross-coupling stimuli on a rotating chair across three GVR treatment interventions: throughout stimulus testing (prevention), following symptom onset (rescue), and placebo control. Subjects perform up to 10 sets of pitch head movements during constant rotation. For each set, head movement is cued every 10 seconds, alternating between pitch forward (chin resting to chest) and pitch backward (head upright) for a total of 7 forward and backward movements. During each head movement, subjects are asked to use a joystick to record the magnitude of their perceived rotation along all three axes. During the 2-minute pause between sets, motion sickness symptom scoring was obtained using the Pensacola Diagnostic Index and subject discomfort (0-20) ratings. Performance on a sensorimotor and cognitive test battery is measured during a fourth session to map changes in GVR level with functional performance. Results: Fifteen of 30 subjects have completed testing to date. Preliminary findings suggest GVR may be more effective in reducing symptoms in subjects who self-report less susceptibility on a pre-test motion sickness susceptibility questionnaire. Based on the joystick measures, GVR significantly reduces both the magnitude (mean 22% - 34%) and duration (mean 42% - 49%) of perceived roll and pitch sensation with head movements during constant rotation. It is important to note that comparable levels of GVR (up to 2.5mA) does not impair performance on a functional test battery including mobility and balance tasks. Discussion: Our preliminary findings suggest GVR may be useful in reducing disorienting roll and pitch illusions associated with Coriolis cross-coupling stimuli. While transfer to post-flight treatment will need to be validated, the potential advantages of our non-pharmaceutical countermeasure approach would be to provide rapid therapeutic effect while allowing continuous titration of GVR amplitude during recovery to maintain operational performance.

Gaurav Pradhan↗

Lyophilization for Water Recovery III, System Design

Mixed liquid/solid wastes, including feces, water processor effluents, and food waste, can be lyophilized (freeze-dried) to recover the water they contain and stabilize the solids that remain. Our previous research has demonstrated the potential benefits of using thermoelectric heat pumps to build a lyophilizer for processing waste in microgravity. These results were used to build a working prototype suitable for ground- based human testing. This paper describes the prototype design and presents results of functional and performance tests.

Litwiller, Eric↗