Search NASA⌕ Search

SEARCH · Search NASA

Results for “geometry factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fluid–Solid Reaction Kinetics for Solids of Nonbasic Geometries and Determination of the Appropriate Shape Factors

The rate analysis involving a solid of nonbasic geometry in general requires a complex numerical solution. A closed-form expression of the reaction rate for such a solid would be very convenient and greatly simplify the analysis. A method for this purpose was developed in this work for solids with shapes of finite cylinders and finite rectangular parallelepipeds reacting under the rate control by chemical reaction or mass transfer, which may be extended to other irregular shapes. In this method, an appropriate shape factor is first obtained under the conditions of a topochemical reaction, which is then applied to the unified rate expressions previously obtained for solids of three basic shapes. Good agreements between the rates predicted with the appropriate shape factors and the exact or numerical solutions were obtained for both reaction-controlled and pore-diffusion-controlled reactions.

36 MATERIALS SCIENCE↗

Thermal quantum coherence and correlation in the extended XY spin chain

Quantum coherence and correlation of thermal states in the extended XY spin chain are studied in terms of the recently proposed l{sub 1} norm, skew information, and Bures distance of geometry discord (BGD), respectively. The entanglement measured via concurrence is calculated for reference. A two-dimensional susceptibility is introduced to explore their capability in highlighting the critical lines associated with quantum phase transitions in the model. It is shown that the susceptibility of the skew information and BGD is a genuine indicator of quantum phase transitions, and characterizes the factorization. However, the l{sub 1} norm is trivial for the factorization. An explicit scaling law of BGD is captured at low temperature in the XY model. In contrast to the entanglement, quantum coherence reveals a kind of long-range nonclassical correlation. Moreover, the obvious relation among model parameters is extracted for the factorized line in the extended model. Those are instructive for the understanding of quantum coherence and correlation in the theory of quantum information, and quantum phase transitions and factorization in condensed-matter physics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Understanding Geometry and Microstructure Interactions In LPBF By Linking Lab Scale Studies To Real Part Case Examples

The mechanical properties derived from simple tensile tests are uniquely important in the design and qualification of load bearing metallic components. The tensile properties in standards for wrought metallic materials are generally accessible for design and simulation engineers, but this is not the case for additively manufactured metals. This work investigates the influence of tensile specimen geometry on the mechanical properties of laser powder bed fusion (LPBF) additively manufactured Ti-6Al-4V, particularly in relation to properties measured from specimens excised from an exemplar part. A comprehensive analysis was conducted across various specimen geometries, considering factors such as thermal history, cross-sectional area, shape, and surface roughness. Key findings reveal that sample size, particularly cross-sectional area, significantly affects reported tensile properties, with ASTM E8 flat and round specimens exhibiting differences in elastic modulus (13%), yield strength (17%), ultimate tensile strength (UTS) (14%), and elongation to failure (11%). Additionally, surface roughness was found to have a limited impact on ASTM round geometries, but it becomes critical in thin-walled and small high-throughput samples. The ASTM flat samples closely matched the properties of samples excised from the exemplar part, underscoring the necessity of testing witness samples that accurately represent end-use conditions. Furthermore, mechanical properties of samples built within the stitch zone of the exemplar part demonstrated reduced ductility, highlighting the importance of laser alignment and qualification in multi-laser additive manufacturing processes. Overall, this study emphasizes the need for careful consideration of specimen geometry and testing conditions to ensure accurate reporting of mechanical properties in LPBF Ti-6Al-4V.

36 MATERIALS SCIENCE↗

Solid Lighting Core Technologies

The overall objective of this project is to demonstrate an ultra-effective light extraction mechanism that can be universally applied to all top-emitting white OLEDs (TE-WOLEDs) and can be integrated with thin film encapsulation techniques. The scope of work proposed in this project includes four major areas: (1) optical modeling; (2) microlens and array fabrication; (3) fabrication, encapsulation, and characterization of TE-WOLEDs; and (4) full device integration and characterization. First , the light extraction efficiency in a top-emitting OLED with or without a microlens array are modeled using wave optics. Second , individual microlenses and microlens arrays are fabricated by inkjet printing of microdroplets of a liquid thiol-ene monomer with high refractive index followed by photopolymerization. Third , high efficiency top-emitting white OLEDs are fabricated, and fully characterized. Finally , optimized microlens arrays are fabricated on TE-WOLEDs with dielectric barrier layers. The overall light extraction efficiency of these devices, as well as its wavelength and angular dependencies, are measured by comparing the efficiencies of devices with and without microlens arrays. In conclusion, we have demonstrated the feasibility of applying inkjet printed microlens arrays to enhance the light extraction efficiency of top-emitting white OLEDs. We have shown that the geometry (contact angle) of the printed microlenses can be controlled by controlling the surface chemistry prior to printing the lenses. A 90% enhancement in the light extraction efficiency has been achieved with printed microlens array on a top-emitting white OLED, which can be further improved to 140% using a more close-packed microlens array fabricated from a molding process. Future work will focus on improvement of the microlens fabrication process to improve the array fill factor and the contact angle, as well as use transparent materials with a higher index of refraction. We will also further optimize the procedures for integrating the microlenses on the top-emitting white OLEDs and characterize the overall light extraction enhancement factor when the microlens array is attached.

36 MATERIALS SCIENCE↗

A pencil beam dose calculation model for CyberKnife system

Purpose: CyberKnife system is initially equipped with fixed circular cones for stereotactic radiosurgery. Two dose calculation algorithms, Ray-Tracing and Monte Carlo, are available in the supplied treatment planning system. A multileaf collimator system was recently introduced in the latest generation of system, capable of arbitrarily shaped treatment field. The purpose of this study is to develop a model based dose calculation algorithm to better handle the lateral scatter in an irregularly shaped small field for the CyberKnife system. Methods: A pencil beam dose calculation algorithm widely used in linac based treatment planning system was modified. The kernel parameters and intensity profile were systematically determined by fitting to the commissioning data. The model was tuned using only a subset of measured data (4 out of 12 cones) and applied to all fixed circular cones for evaluation. The root mean square (RMS) of the difference between the measured and calculated tissue-phantom-ratios (TPRs) and off-center-ratio (OCR) was compared. Three cone size correction techniques were developed to better fit the OCRs at the penumbra region, which are further evaluated by the output factors (OFs). The pencil beam model was further validated against measurement data on the variable dodecagon-shaped Iris collimators and a half-beam blocked field. Comparison with Ray-Tracing and Monte Carlo methods was also performed on a lung SBRT case. Results: The RMS between the measured and calculated TPRs is 0.7% averaged for all cones, with the descending region at 0.5%. The RMSs of OCR at infield and outfield regions are both at 0.5%. The distance to agreement (DTA) at the OCR penumbra region is 0.2 mm. All three cone size correction models achieve the same improvement in OCR agreement, with the effective source shift model (SSM) preferred, due to their ability to predict more accurately the OF variations with the source to axis distance (SAD). In noncircular field validation, the pencil beam calculated results agreed well with the film measurement of both Iris collimators and the half-beam blocked field, fared much better than the Ray-Tracing calculation. Conclusions: The authors have developed a pencil beam dose calculation model for the CyberKnife system. The dose calculation accuracy is better than the standard linac based system because the model parameters were specifically tuned to the CyberKnife system and geometry correction factors. The model handles better the lateral scatter and has the potential to be used for the irregularly shaped fields. Comprehensive validations on MLC equipped system are necessary for its clinical implementation. It is reasonably fast enough to be used during plan optimization.

60 APPLIED LIFE SCIENCES↗

Modulation of contact resistance between metal and graphene by controlling the graphene edge, contact area, and point defects: An ab initio study

A systematic first-principles non-equilibrium Green's function study is conducted on the contact resistance between a series of metals (Au, Ag, Pt, Cu, Ni, and Pd) and graphene in the side contact geometry. Different factors such as the termination of the graphene edge, contact area, and point defect in contacted graphene are investigated. Notable differences are observed in structural configurations and electronic transport characteristics of these metal-graphene contacts, depending on the metal species and aforementioned influencing factors. It is found that the enhanced chemical reactivity of the graphene due to dangling bonds from either the unsaturated graphene edge or point defects strengthens the metal-graphene bonding, leading to a considerable contact resistance reduction for weakly interacting metals Au and Ag. For stronger interacting metals Pt and Cu, a slightly reduced contact resistance is found due to such influencing factors. However, the wetting metals Ni and Pd most strongly hybridize with graphene, exhibiting negligible dependence on the above influencing factors. This study provides guidance for the optimization of metal-graphene contacts at an atomic scale.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The 2011 outburst of recurrent nova T PYX: Radio observations reveal the ejecta mass and hint at complex mass loss

Despite being the prototype of its class, T Pyx is arguably the most unusual and poorly understood recurrent nova. Here, we use radio observations from the Karl G. Jansky Very Large Array to trace the evolution of the ejecta over the course of the 2011 outburst of T Pyx. The radio emission is broadly consistent with thermal emission from the nova ejecta. However, the radio flux began rising surprisingly late in the outburst, indicating that the bulk of the radio-emitting material was either very cold, or expanding very slowly, for the first ∼50 days of the outburst. Considering a plausible range of volume filling factors and geometries for the ejecta, we find that the high peak flux densities of the radio emission require a massive ejection of (1-30) × 10{sup –5} M {sub ☉}. This ejecta mass is much higher than the values normally associated with recurrent novae, and is more consistent with a nova on a white dwarf well below the Chandrasekhar limit.

79 ASTRONOMY AND ASTROPHYSICS↗

SEVEN-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE (WMAP ) OBSERVATIONS: PLANETS AND CELESTIAL CALIBRATION SOURCES

We present WMAP seven-year observations of bright sources which are often used as calibrators at microwave frequencies. Ten objects are studied in five frequency bands (23-94 GHz): the outer planets (Mars, Jupiter, Saturn, Uranus, and Neptune) and five fixed celestial sources (Cas A, Tau A, Cyg A, 3C274, and 3C58). The seven-year analysis of Jupiter provides temperatures which are within 1{sigma} of the previously published WMAP five-year values, with slightly tighter constraints on variability with orbital phase (0.2% {+-} 0.4%), and limits (but no detections) on linear polarization. Observed temperatures for both Mars and Saturn vary significantly with viewing geometry. Scaling factors are provided which, when multiplied by the Wright Mars thermal model predictions at 350 {mu}m, reproduce WMAP seasonally averaged observations of Mars within {approx}2%. An empirical model is described which fits brightness variations of Saturn due to geometrical effects and can be used to predict the WMAP observations to within 3%. Seven-year mean temperatures for Uranus and Neptune are also tabulated. Uncertainties in Uranus temperatures are 3%-4% in the 41, 61, and 94 GHz bands; the smallest uncertainty for Neptune is 8% for the 94 GHz band. Intriguingly, the spectrum of Uranus appears to show a dip at {approx}30 GHz of unidentified origin, although the feature is not of high statistical significance. Flux densities for the five selected fixed celestial sources are derived from the seven-year WMAP sky maps and are tabulated for Stokes I, Q, and U, along with polarization fraction and position angle. Fractional uncertainties for the Stokes I fluxes are typically 1% to 3%. Source variability over the seven-year baseline is also estimated. Significant secular decrease is seen for Cas A and Tau A: our results are consistent with a frequency-independent decrease of about 0.53% per year for Cas A and 0.22% per year for Tau A. We present WMAP polarization data with uncertainties of a few percent for Tau A. Where appropriate, WMAP results are compared against previous findings in the literature. With an absolute calibration uncertainty of 0.2%, WMAP data are a valuable asset for calibration work.

79 ASTRONOMY AND ASTROPHYSICS↗

(U) Endpoint Energy and Scintillator Geometry Effects on the Swank Factor, Quantum Efficiency, and DQE(0) for High-Energy Radiography

High-energy radiography is used to image imploding materials to better understand weapon design and performance. The Enhanced Capabilities for Subcritical Experiments (ECSE) is a new facility proposal that aims to collect radiographic images of nuclear material. As part of the facility design, we aim to optimize data quality and radiographic performance by investigating different detector designs. We addressed design decisions by simulating different scintillator designs using M CNP6 and calculated the quantum efficiency, Swank factor, and detective quantum efficiency at zero-frequency (DQE(O)). First, we investigated the effects of the x-ray endpoint energy on the detector response. We generated three x-ray spectra with endpoint energies of 20 MeV, 22 MeV, and 24 MeV. The three raw spectra were filtered using the Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) line-of-sight materials along with 1) flat field filtration using 7 cm tungsten alloy in the bullnose and 2) an FTO with 4 plates. The scatter-to-direct radiation ratio was much larger for FTO with 4 plates (50-60%) compared to the flat field with 7 cm of bullnose material (8%). We used these filtered spectra to calculate the detector response for the original DARHT segmented scintillator design. We found that the endpoint energy and filtration had a negligible effect on the detector response. The quantum efficiency was 0.63, the Swank factor was 0.84, and the DQE(O) was 0.53 for all six spectra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Status of Shift for NCS Applications in SCALE 6.3 [Slides]

Shift can run most KENO V.a and KENO-VI inputs, but beware of small geometry fudge factors. Shift is faster than KENO for fast spectrum systems, but has a higher uncertainty per particle. KENO FoM is higher for thermal systems. KENO V.a in MG is significantly faster than KENO V.a in CE, so this may exacerbate Shift difference. Shift generally has greater speedup for parallel calculations. Shift has only IFP available for TSUNAMI-3D, but parallel calculations are enabled.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Model Calibration vs. Physics-guided Coverage Mapping: Case Study - Pressure Drop Calculations

This work deals with a fundamental question in model validation: given a body of available experiments and an envisaged domain of nuclear reactor operating conditions (referred to as the reactor application), how can one develop a quantitative approach that measures the portion of the prior uncertainties of the reactor application that is covered by the available experiments? Coverage here means that the uncertainties of the reactor application are originating from and behaving in exactly the same way as those observed at the experimental conditions. This approach is valuable as it provides a scientifically defendable criterion by which experimentally measured biases can be credibly extrapolated (i.e., mapped) to biases for the reactor applications. This work focuses on the application of a new methodology, referred to as physics-guided coverage mapping (PCM), to the estimation of hydraulic pressure losses in reactor pipes. PCM provides a generic, calibration-free approach to the mapping of experimental biases by relying on high fidelity physics simulation and information theoretic measure how much of the application domain is covered by the experiments. The idea is to employ the physics models to establish a joint probability distribution that relates the application and the available body of experiments. An information-theoretic measure, referred to as the mutual information, is used to calculate a quantitative metric that measures the inter-dependence between the application and the experiment. A virtual experiment is employed to demonstrate the application of PCM, wherein the pressure drop is calculated for both the experiment and the application using two different flow conditions, i.e., laminar and turbulent, and the experimental values are simulated. All parameters introducing uncertainties, such as geometry, friction factor formulas and their associated parameters are also incorporated. The results obtained with PCM are compared to a conventional calibration-based approach. This work show that the proposed approach can circumvent a number of challenges that face calibration-based methods, such as nonlinearity, ill-posedness and error compensation in high dimensional models with many parameters. This work focus primarily in this summary on parameter uncertainties and how they can be treated using PCM. In a separate summary, discuss performance of PCM under the presence of modeling uncertainties. This simple study has shown that calibration techniques for very simple situations cannot correctly scale the measurements from the experimental to the application domain. It is our view that is occurs primarily due the phenomenon of error compensation where on artificially changes the value of selected parameters to account for all sources of uncertainties. The situation gets more complicated when one calibrates multiple parameters where now the problem could potentially have an infinite number of ways by which the errors can be compensated. (authors)

42 ENGINEERING↗

SDSS-IV/MaNGA: SPECTROPHOTOMETRIC CALIBRATION TECHNIQUE

Mapping Nearby Galaxies at Apache Point Observatory (MaNGA), one of three core programs in the Sloan Digital Sky Survey-IV, is an integral-field spectroscopic survey of roughly 10,000 nearby galaxies. It employs dithered observations using 17 hexagonal bundles of 2″ fibers to obtain resolved spectroscopy over a wide wavelength range of 3600–10300 Å. To map the internal variations within each galaxy, we need to perform accurate spectral surface photometry, which is to calibrate the specific intensity at every spatial location sampled by each individual aperture element of the integral field unit. The calibration must correct only for the flux loss due to atmospheric throughput and the instrument response, but not for losses due to the finite geometry of the fiber aperture. This requires the use of standard star measurements to strictly separate these two flux loss factors (throughput versus geometry), a difficult challenge with standard single-fiber spectroscopy techniques due to various practical limitations. Therefore, we developed a technique for spectral surface photometry using multiple small fiber-bundles targeting standard stars simultaneously with galaxy observations. We discuss the principles of our approach and how they compare to previous efforts, and we demonstrate the precision and accuracy achieved. MaNGA's relative calibration between the wavelengths of Hα and Hβ has an rms of 1.7%, while that between [N ii] λ6583 and [O ii] λ3727 has an rms of 4.7%. Using extinction-corrected star formation rates and gas-phase metallicities as an illustration, this level of precision guarantees that flux calibration errors will be sub-dominant when estimating these quantities. The absolute calibration is better than 5% for more than 89% of MaNGA's wavelength range.

79 ASTRONOMY AND ASTROPHYSICS↗

Origin of circular dichroism in resonant elastic x-ray scattering from magnetic and polar chiral structures

Circular dichroism in resonant elastic x-ray scattering (CD-REXS) has recently been observed in chiral structures composed of multiferroic materials as well as magnetic moments or electric polarization vectors. In order to comprehensively understand the experimental results of these previous studies, we present here in detail the analytical formulation of CD-REXS for one-dimensional helices composed of magnetic moments and electric polarization vectors, respectively. In particular, by comparing CD-REXS for a proper-screw-shaped Bloch-type helix and cycloid-shaped Néel-type helix, we found that CD-REXS for both magnetic and polar helices can discriminate between both types of helices. We also found that the x-ray polarization factor depending on the scattering geometry is a significant factor in determining the characteristics of CD-REXS for chiral structures. The results obtained from the detailed formulas can be intuitively understood using the concept of mirror reflection. In particular, in this way it can be understood that Bloch- and Néel-type helices correspond to truly chiral and achiral structures, respectively, and why CD-REXS is able to distinguish between these two types of helices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Coaxial Electrode Geometry on the Electric Field Enhancement Factor for a High Voltage Vacuum Gap

We present an experimental analysis of the change in the electric field enhancement factor with varying gap size and penetration depth (P.D) of cathode into anode for a coaxial vacuum gap, diagnosed using Fowler–Nordheim analysis and optical imaging via scanning electron microscope (SEM) and time integrated Digital single lens reflex camera (DSLR). Data were collected on the Coaxial Gap Breakdown Machine (240 A, 25 kV, 150 ns, 0.1 Hz). Experiments using five different gap sizes at nine different P.Ds are compared over runs comprising 50 shots for each case. The results show a strong link between enhancement factor and gap size, with P.D and surface topology. For large gap sizes, 150, 330, and 700 μm, the average enhancement factor value increases with increasing P.D. For smaller gap sizes, 50 and 100 μm, the average enhancement factor decreases with P.D. SEM imaging before and after plasma formation for each gap size allows for quantifying surface finish, microprotrusion growth, average blast diameter, and an estimation of the surface area breakdowns occupy. Time integrated DSLR imaging analysis of the gap at each shot allows for a determination of the distribution of breakdowns about the circumference of the gap for each case tested. Here, the Fowler–Nordheim analysis allows for a quantitative analysis of the surface roughness of all gap sizes tested. Results show that for large gap sizes, the gap geometry and increasing area of breakdown is the main cause for increasing average enhancement factor. For small gap sizes, the dominant driving factor for small average enhancement factors—that subsequently decrease with P.D—is significant changes in surface topology due to an increased number of breakdowns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Torque-Tube Parameters on Rear-Irradiance and Rear-Shading Loss for Bifacial PV Performance on 1-Axis Tracking Systems

The emergence of cost-competitive bifacial PV modules has raised the question of the additional value of bifacial modules in 1-axis tracking arrays, in particular when considering rear-irradiance losses from the tracker system itself. In this work, the effect of different geometries and materials of torque tubes is evaluated and found to reduce rear-irradiance averages without any torque-tube shading by 0.1 to 12% for metallic and black absorptive torque tubes respectively for a clear-sky day. This paper will compare modeled to measured rear-irradiance profiles, and propose a recommended range of rear-shading loss factors for different geometry conditions. The effect of rear-irradiance distribution into electrical mismatch loss will also be explored. shading by 0.1 to 12% for metallic and black absorptive torque tubes respectively for a clear-sky day. This paper will compare modeled to measured rear-irradiance profiles, and propose a recommended range of rear-shading loss factors for different geometry conditions. The effect of rear-irradiance distribution into electrical mismatch loss will also be explored.

14 SOLAR ENERGY↗

Temperature-dependent structural studies of mullite-type Bi{sub 2}Fe{sub 4}O{sub 9}

We report on the temperature-dependent structural studies on the mullite-type Bi{sub 2}Fe{sub 4}O{sub 9} compound. The crystal structures were determined using both powder X-ray diffraction and single crystal neutron diffraction. The thermal expansion of the cell parameters from smallest to largest occurred in the order a<c<b; their expansion behavior was fit using either linear or nonlinear regression according to the region of choice. The anisotropic thermal expansion was monitored with respect to the expansion coefficients, anisotropy factor, and polyhedral geometry. At 900 K an abrupt change of the anisotropy factor is observed which correlates with a slope in the BiO{sub 6} polyhedral volume. At the same temperature the FeO{sub 4} tetrahedral distortion starts to increase. The temperature-dependent stereochemically activity of the Bi{sup 3+} 6s{sup 2} lone electron pair was probed by the absolute value of eccentricity parameter. This parameter shows a significant drop at around 773 K. Additionally, the average crystal size and micro-strain of the powder samples were studied. A healing of intrinsic defects is observed with respect to a decreasing micro-strain followed by crystal growth above about 900 K. The temperature-dependent infrared spectra were described in three distinct zones. Deconvolution of the absorption features between 370 cm{sup -1} and 1000 cm{sup -1} required nine fitted bands, and the decomposed Pseudo-Voigt elements were assigned to Fe-O stretching, Fe-O-Fe bending and O-Fe-O bending vibrations. The shift of the observed modes was described with respect to temperature. An effective linewidth parameter {Delta}corr was determined by autocorrelation analysis between 740 cm{sup -1} and 900 cm{sup -1} for each temperature-dependent spectrum. The break of the slope of {Delta}corr at about 773 K was interpreted as the change of some vibrational modes of the FeO{sub 4} tetrahedra. The intrinsic effects observed around 773 K are responsible for extrinsic parameter changes found around 900 K. - Graphical abstract: Temperature-dependent stereochemical activity (eccentricity |{Phi}{sub i}|) of the Bi{sup 3+} 6s{sup 2} lone electron pair directing in the non-bonded region of the Bi-O coordination in the Bi{sub 2}Fe{sub 4}O{sub 9} iron framework (given as polyhedra). Highlights: Black-Right-Pointing-Pointer Complex expansion-contraction mechanism explains anisotropic thermal expansion. Black-Right-Pointing-Pointer Bi 6s{sup 2} lone electron pair sphericity influences analyses by FTIR autocorrelation. Black-Right-Pointing-Pointer Intrinsic effects at 773 K are responsible for extrinsic parameter changes at 900 K.

36 MATERIALS SCIENCE↗

Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging

Purpose: This work applies a cascaded systems model for cone-beam CT imaging performance to the design and optimization of a system for musculoskeletal extremity imaging. The model provides a quantitative guide to the selection of system geometry, source and detector components, acquisition techniques, and reconstruction parameters. Methods: The model is based on cascaded systems analysis of the 3D noise-power spectrum (NPS) and noise-equivalent quanta (NEQ) combined with factors of system geometry (magnification, focal spot size, and scatter-to-primary ratio) and anatomical background clutter. The model was extended to task-based analysis of detectability index (d') for tasks ranging in contrast and frequency content, and d' was computed as a function of system magnification, detector pixel size, focal spot size, kVp, dose, electronic noise, voxel size, and reconstruction filter to examine trade-offs and optima among such factors in multivariate analysis. The model was tested quantitatively versus the measured NPS and qualitatively in cadaver images as a function of kVp, dose, pixel size, and reconstruction filter under conditions corresponding to the proposed scanner. Results: The analysis quantified trade-offs among factors of spatial resolution, noise, and dose. System magnification (M) was a critical design parameter with strong effect on spatial resolution, dose, and x-ray scatter, and a fairly robust optimum was identified at M {approx} 1.3 for the imaging tasks considered. The results suggested kVp selection in the range of {approx}65-90 kVp, the lower end (65 kVp) maximizing subject contrast and the upper end maximizing NEQ (90 kVp). The analysis quantified fairly intuitive results--e.g., {approx}0.1-0.2 mm pixel size (and a sharp reconstruction filter) optimal for high-frequency tasks (bone detail) compared to {approx}0.4 mm pixel size (and a smooth reconstruction filter) for low-frequency (soft-tissue) tasks. This result suggests a specific protocol for 1 x 1 (full-resolution) projection data acquisition followed by full-resolution reconstruction with a sharp filter for high-frequency tasks along with 2 x 2 binning reconstruction with a smooth filter for low-frequency tasks. The analysis guided selection of specific source and detector components implemented on the proposed scanner. The analysis also quantified the potential benefits and points of diminishing return in focal spot size, reduced electronic noise, finer detector pixels, and low-dose limits of detectability. Theoretical results agreed quantitatively with the measured NPS and qualitatively with evaluation of cadaver images by a musculoskeletal radiologist. Conclusions: A fairly comprehensive model for 3D imaging performance in cone-beam CT combines factors of quantum noise, system geometry, anatomical background, and imaging task. The analysis provided a valuable, quantitative guide to design, optimization, and technique selection for a musculoskeletal extremities imaging system under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-gluon correlations in heavy–light ion collisions: Energy and geometry dependence, IR divergences, and k T -factorization

Here, we study the properties of the cross section for two-gluon production in heavy–light ion collisions derived in our previous paper in the saturation/Color Glass Condensate framework. Concentrating on the energy and geometry dependence of the corresponding correlation functions we find that the two-gluon correlator is a much slower function of the center-of-mass energy than the one- and two-gluon production cross sections. The geometry dependence of the correlation function leads to stronger azimuthal near- and away-side correlations in the tip-on-tip U + U collisions than in the side-on-side U + U collisions, an exactly opposite behavior from the correlations generated by the elliptic flow of the quark–gluon plasma: a study of azimuthal correlations in the U + U collisions may thus help to disentangle the two sources of correlations. We demonstrate that the cross section for two-gluon production in heavy–light ion collisions contains a power-law infrared (IR) divergence even for fixed produced gluon momenta: while saturation effects in the target regulate some of the power-law IR-divergent terms in the lowest-order expression for the two-gluon correlator, other power-law IR-divergent terms remain, possibly due to absence of saturation effects in the dilute projectile. Finally we rewrite our result for the two-gluon production cross-section in a k T -factorized form, obtaining a new factorized expression involving a convolution of one- and two-gluon Wigner distributions over both the transverse momenta and impact parameters. Lastly, we show that the two-gluon production cross-section depends on two different types of unintegrated two-gluon Wigner distribution functions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗