Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

End-Use Load Profiles for the U.S. Building Stock: Methodology and Results of Model Calibration, Validation, and Uncertainty Quantification

The United States is embarking on an ambitious transition to a 100% clean energy economy by 2050, which will require improving the flexibility of electric grids. One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High- quality end-use load profiles (EULPs) provide this information, and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation (Frick, Eckman, and Goldman 2017; Frick 2019). To help fill this gap, the U.S. Department of Energy (DOE) funded a three-year project - End-Use Load Profiles for the U.S. Building Stock - that culminated in the release of a publicly available dataset1 of simulated EULPs representing residential and commercial buildings across the contiguous United States. The motivation for this work is further detailed in a November 2019 report: Market Needs, Use Cases, and Data Gaps (Mims Frick et al. 2019). This Methodology and Results report provides detailed descriptions of how the dataset was developed, intended for an audience of dataset and model users interested in the technical details. These details include descriptions of all of the model improvements made for calibration and the final comparisons to empirical data sources. A companion report, End-Use Load Profiles for the U.S. Building Stock: Applications and Opportunities, will be published subsequently and will describe example applications and considerations for using the dataset, intended for an audience of general dataset users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Load Profiles for the U.S. Building Stock

The United States is embarking on an ambitious transition to a 100% clean energy economy by 2050, which will require improving the flexibility of electric grids. One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High quality end-use load profiles (EULPs) provide this information, and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation. To help fill this gap, the U.S. Department of Energy (DOE) funded a three-year project, End-Use Load Profiles for the U.S. Building Stock, that culminated in this publicly available dataset of calibrated and validated 15-minute resolution load profiles for all major residential and commercial building types and end uses, across all climate regions in the United States. These EULPs were created by calibrating the ResStock and ComStock physics-based building stock models using many different measured datasets, as described in the "Technical Report Documenting Methodology" linked in the submission.

Array↗

Advancing Grid Resilience through Smart Charge Management: Findings from Maryland’s Pilot

This report presents research findings from a four-year Smart Charge Management (SCM) pilot program conducted by Maryland’s largest electric utilities—Baltimore Gas and Electric (BGE), Potomac Electric Power Company (Pepco), and Delmarva Power & Light (DPL)—to evaluate strategies for optimizing electric vehicle (EV) charging loads and enhancing grid stability. Supported by the U.S. Department of Energy (DOE), Argonne National Laboratory collaborated with all project partners and examined the effectiveness of Time-of-Use (TOU) and Load Balancing (LB) strategies in managing peak demand, deferring costly infrastructure upgrades, and reducing grid constraints at the feeder level. Using charging data from over 4,600 EV drivers, the study analyzed SCM’s impact on the distribution systems of BGE and Pepco, which consists of over 2000 feeders. Unlike prior research that focused on system-wide trends or synthetic feeders, this analysis offers granular, feeder-level insights based on real-world operational data. It highlights how transformer density, load profiles, and infrastructure constraints influence smart charging performance. Results show feeder-level conditions play a crucial role in SCM effectiveness, with most feeders benefiting more from LB, while TOU-based SCM may be sufficient for others. By 2035, LB reduced peak charging loads by 27% on average, compared to 23% under TOU-based SCM, though some feeders saw reductions exceeding 35%, while others experienced minimal impact. Feeders with higher transformer utilization and limited capacity benefited more from LB, which more effectively distributed charging demand during off-peak hours. Beyond reducing grid constraints, SCM offers long-term operational and financial benefits. By shifting EV charging demand strategically, utilities can optimize asset utilization, delay infrastructure investments, and enhance grid performance. In terms of infrastructure upgrade deferrals, at the feeder level, LB consistently reduced peak charging loads and resulting infrastructure upgrade costs, particularly in high EV enrollment areas, decreasing the number of overloaded transformers by up to 35%, while TOU-based SCM achieved 20-30% reductions depending on feeder characteristics. At the system level, LB has the potential to defer total upgrade costs by $\$$186 million for BGE, compared to $\$$159 million under TOU-based SCM. For Pepco, TOU-based SCM performed slightly better, deferring upgrade costs by $\$$30 million, compared to $\$$29 million under LB. Section 4.5 reviews some of the system differences between BGE and Pepco. However, as EV adoption scales, TOU-based SCM will introduce secondary peak charging loads, reinforcing the need for more advanced, adaptive SCM approaches to prevent new grid challenges. As EV adoption continues to grow, feeder-level managed charging strategies will be essential for mitigating grid stress, improving infrastructure efficiency, and maintaining energy affordability for consumers. This report provides critical insights for utilities, Public Utility Commissions (PUCs), and state agencies on the role of feeder-specific smart charging in infrastructure planning, policy development, and grid modernization. The findings underscore the importance of tailored, data-driven SCM solutions that align with local grid conditions, ensuring a resilient, cost-effective transition to increasing EV adoption while safeguarding distribution system performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sequence Impedance Measurement of Utility-Scale Wind Turbines and Inverters – Reference Frame, Frequency Coupling, and MIMO/SISO Forms

Sequence impedance responses with or without considering frequency coupling in both MIMO and SISO forms are increasingly used for the stability analysis of three-phase power electronic systems; however, many aspects of sequence impedance measurement are not fully explored. It is not clear if the sequence impedance has a reference frame similar to the dq impedance. If so, the role of the grid voltage angle estimation in aligning the sequence impedance reference frame has not been discussed. Additionally, existing methods for measuring the sequence impedance with frequency coupling are complicated, are not feasible for large wind turbines and inverters, and provide the sequence impedance responses in only either MIMO or SISO form. This paper presents a sequence impedance measurement method that considers the frequency coupling, performs reference frame alignment, demonstrates the impact of the grid voltage angle estimation, and obtains the sequence impedance response in both MIMO and SISO forms. This paper demonstrates the proposed method and practical problems associated with the sequence impedance measurement of utility-scale wind turbines and inverters on a 1.9-MW Type III wind turbine and a 2.2-MVA inverter using an impedance measurement system built around a 7-MW/13.8-kV grid simulator and a 5-MW dynamometer.

17 WIND ENERGY↗

On the numerical sensitivity of cellular automata grain structure predictions to large thermal gradients and cooling rates

Cellular automata (CA) models of as-solidified grain structure, originally developed and applied to casting, have become a common means of predicting grain structure resulting from Additive Manufacturing (AM) processes. The majority of these models are based on the decentered octahedron approach, which attempts to correct for the effect of grid anisotropy on the prediction of competitive solidification of dendritic grains. However, AM solidification occurs under cooling rates ($\dot{T}$) and thermal gradients (G) that are orders of magnitude larger than those encountered in casting, and no systematic investigation on the effect of the CA model cell size (Δx) and time step (Δt) on AM microstructure predictions has been performed. Here, in this study, such an investigation is first performed via simulation of individual grains of various crystallographic orientations with a fixed, unidirectional G, showing that CA prediction of the steady-state undercooling matched the expected values based on the interfacial response function at small G and deviated from the expected values at large G. Simulation of competitive growth of multiple grains showed a weakening of the predicted texture as G and Δx became large. Simulation of solidification under AM conditions, where G and $\dot{T}$ vary spatially across the melt pools, showed that not only does grain selection weaken and deviate from expectations at large Δx, but grains with crystallographic $\langle$100$\rangle$ aligned with the grid directions are more adversely affected by the temperature field discontinuities than grains with other crystallographic orientations. Despite the fact that the exact grain competition results depended on Δt, the overall texture development was notably less sensitive to Δt than Δx, provided that a reasonable value of Δt is selected based on the ratio of Δx to the maximum local solidification velocity in the simulation domain. Finally, from the directional solidification and AM simulation results, an analysis of computational cost compared to simulation resolution is performed based on an equation derived to quantify the relatively inaccuracy in grain selection based on the model and temperature field inputs. From this analysis, it is concluded that there is a need for algorithmic improvements to improve CA grain competition accuracy for large G processing conditions as sufficiently small Δx to resolve the necessary competition is intractable for many AM processing conditions.

36 MATERIALS SCIENCE↗

Fast solvers for tokamak fluid models with PETSc

Multigrid (MG) is widely recognized as a highly effective solver for the model problem, the Laplacian, but textbook MG fails on most problems of interest. MG methods have been applied to complex, real-world applications with careful consideration of the physical model and discretization. In this work we develop the first step in applying MG methods to science and engineering relevant magnetohydrodynamics (MHD) tokamak models in the M3D-C1 (https://m3dc1.pppl.gov) fusion energy science code. The semi-implicit time integrator in M3D-C1 is composed of many linear solves. The implicit advance of the momentum equation is the most challenging and is the focus of this work. The current production solver in M3D-C1 is a block Jacobi (BJ) preconditioner within a Krylov solver, where blocks group degrees of freedom on planes of constant toroidal coordinate. BJ convergence degrades as the number of planes increases due to the spectral properties of the matrix preconditioned with BJ. The partially magnetic field-aligned, regular toroidal grid structure in M3D-C1 is amenable to semi-coarsening geometric MG in the toroidal direction. This paper develops such a solver and demonstrates competitive performance on a runaway electron model of a SPARC (https://cfs.energy/technology/sparc) disruption, and superior robustness on a stellarator model on which the BJ solver fails to converge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kinetic particle simulations in a global toroidal geometry

The gyrokinetic toroidal code has been upgraded for global simulations by coupling the core and scrape-off layer regions across the separatrix with field-aligned particle-grid interpolations. A fully kinetic particle pusher for high frequency waves (ion cyclotron frequency and beyond) and a guiding center pusher for low frequency waves have been implemented using cylindrical coordinates in a global toroidal geometry. The two integrators correctly capture the particle orbits and agree well with each other, conserving energy and canonical angular momentum. As a verification and application of this new capability, ion guiding center simulations have been carried out to study ion orbit losses at the edge of the DIII-D tokamak for single null magnetic separatrix discharges. The ion loss conditions are examined as a function of the pitch angle for cases without and with a radial electric field. We report the simulations show good agreement with past theoretical results and with the experimentally observed feature in which high energy ions flow out along the ion drift orbits and then hit the divertor plates. A measure of the ion direct orbit loss fraction shows that the loss fraction increases with the ion energy for DIII-D in the initial velocity space. Finally, as a further verification of the capability of the new code, self-consistent simulations of zonal flows in the core region of the DIII-D tokamak were carried out. All DIII-D simulations were performed in the absence of turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources

This study addresses the compliance of Inverter-based Resources (IBRs) with IEEE Standard 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a controller development framework for abnormal grid conditions. This framework caters to maintaining ride-through operation in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller frame-work is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

IEEE Std 2800↗

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources: Preprint

This study addresses the compliance of Inverter-based Resources (IBRs) with the IEEE Std 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a comprehensive controller development framework. This framework caters to maintaining ride-trhough operation or implementing strategic disconnections in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller framework is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

IEEE Std 2800↗

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources

This study addresses the compliance of Inverter-based Resources (IBRs) with IEEE Standard 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a controller development framework for abnormal grid conditions. This framework caters to maintaining ride-through operation in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller framework is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

grid↗

Direct-write orientation of charge-transfer liquid crystals enables polarization-based coding and encryption

Abstract Optical polarizers encompass a class of anisotropic materials that pass-through discrete orientations of light and are found in wide-ranging technologies, from windows and glasses to cameras, digital displays and photonic devices. The wire-grids, ordered surfaces, and aligned nanomaterials used to make polarized films cannot be easily reconfigured once aligned, limiting their use to stationary cross-polarizers in, for example, liquid crystal displays. Here we describe a supramolecular material set and patterning approach where the polarization angle in stand-alone films can be precisely defined at the single pixel level and reconfigured following initial alignment. This capability enables new routes for non-binary information storage, retrieval, and intrinsic encryption, and it suggests future technologies such as photonic chips that can be reconfigured using non-contact patterning.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated GW Farm ABM

This Data Repository includes data used for the integrated groundwater- farm ABM model, raw model output from scenario ensemble, and processed outputs that isolate the groundwater storage depletion outcomes for the 35,000 farm cells. Model Inputs: Farm ABM Inputs: This folder contains the input data used by the integrated groundwater - farm ABM modelling script (Python file) used for the high performance computing (HPC) experiments. The sub-folder "data inputs" contains all of the farm attribute data, while the three files in the folder have the hydrogeological data lookup table (NLDAS Cost Curve Attributes.csv), a lookup table (Theis well function table.csv) for the groundwater cost curve function, and the farm indexes and corresponding NLDAS ids for all of the cells run in this experiment (nldas farms subset final.csv). NLDAS Cost curve hydrogeological data: Hydrogeological data aggregated to 1/8 degree resolution and aligned with the NLDAS grid. Parameters include: water depth below ground surface [meters], subsurface porosity [unitless], aquifer depth from ground surface to aquifer bottom [meters], annual average recharge (USGS: mm, Doll: meters), and three different hydraulic conductivity (K) values (meters/day). The three K values represent the mean value from Gleeson et al. (2018), one standard deviation above the mean from Gleeson et al. (2018), and the de Graaf et al. 2020 modifications to certain lithologies. Additional information about these datasets and their processing are documented in the supplement to Yoon et al. 2025 (in review). Output: Raw outputs: This folder contains a .zip file that has model outputs for the entire scenario ensemble. There is one csv for each farm id, using the format "farm farmid cases.csv". The relationship between the farm id and NLDAS id is defined by the "nldas farms subset final.csv" located in the Farm ABM Inputs folder. Each csv has 625 rows, corresponding to 625 combinations of different scenario parameter values. Each row (scenario) represents the outcome of a 100 year simulation. Columns define scenario settings and summary statistics for each scenario. The first four columns define the scenario settings: "hydro ratio," "econ ratio," "K scenario," and "gamma scenario." The hydro and econ ratios are values passed to the modeling script that influence multipliers for other model parameters, as documented in the supplement to Yoon et al. 2025 (in review). The gamma multiplier is a coefficient multiplier applied to the baseline gamma values (values below 1 represent lower unobserved costs compared to baseline, values above 1 represent higher costs). The K scenario names represent K values of: "low": 0.5 m/d, "int 1": 2.5 m/d, "int 2": 10 m/d, "high": 50 m/d, and "gleeson": mean Gleeson K value. "Perc vol depleted" is the fraction of groundwater depleted at the end of the 100 simulation. Processed Output: Derived depletion outcomes from raw outputs: All of the individual csv files from the Raw outputs were aggregated into a single file that has the scenario settings and fraction depletion "Perc vol depleted" for every farm cell, for every scenario. The other two files define relationships between the farm id, NLDAS id, and local and major aquifer units, used for aquifer-level depletion analysis.

Agent based modeling↗

Continuum gyrokinetic simulations of edge plasmas in single-null geometries

The first continuum gyrokinetic calculations of electrostatic ion scale turbulence are presented for the case of a diverted tokamak geometry. The simulation model solves the long-wavelength limit of the full-F gyrokinetic equation for ion species coupled to the quasi-neutrality equation for electrostatic potential variations, where a fluid model is used for an electron response. Furthermore, in order to facilitate simulations of highly-anisotropic microturbulence in the presence of strong magnetic shear and a magnetic X-point, a numerical algorithm utilizing a locally field-aligned multiblock coordinate system has been developed and implemented in the 5D finite-volume code COGENT. In this approach, the toroidal direction is divided into blocks, such that within each block, the cells are field-aligned and a non-matching grid interface is allowed at block boundaries. The toroidal angle corresponds to the “coarse” field-aligned coordinate, whereas the poloidal cross section, comprised of the radial and poloidal directions, is finely gridded to resolve short-scale perpendicular turbulence structures and to support accurate re-mapping (interpolation) at block boundaries. The 5D simulations explore cross-separatrix ion scale turbulence in the presence of a self-consistent radial electric field and address the effects of magnetic-shear stabilization in the X-point region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced-Research-on-Integrated-Energy-Systems-Based Analysis to Support Resilient System Upgrades: Energy to Communities Energyshed In-Depth Partnership with Molokai, Hawaii

The Molokai, Hawaii, Energy to Communities (E2C) Energyshed project represents a collaborative effort between the National Laboratory of the Rockies, Shake Energy Collaborative, the Molokai Clean Energy Hui, Sustainable Molokai, and Ho'ahu Energy Cooperative Molokai to advance Molokai's Community Energy Resilience Action Plan (CERAP). Supported by Hawaiian Electric Company and the Hawaii State Energy Office, the initiative aims to develop a community-defined portfolio of renewable energy solutions that enhance energy resilience while aligning with the Hawaiian Electric Integrated Grid Plan (IGP) and Molokai's energy goals. Phase 1 focused on technical analyses and community engagement to co-design feasible energy scenarios. Challenges such as grid upgrades, storage sizing, and inverter ride-through standards were addressed to align technical and operational requirements with community preferences. The project equips Molokai with actionable data and insights to implement energy initiatives while ensuring resilient and culturally informed solutions. Future efforts aim to finalize project designs, secure interconnection agreements, and deploy energy projects that reflect community priorities and technical feasibility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms

The “Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms” project focuses on exploring alternative power converter and system-level plant configurations to achieve the lowest cost and highest energy output for a given solar plus storage (e.g., PV + battery) plant, including the use of medium voltage (MV) collection while taking into account detailed models of all elements. To realize this objective, four approaches were utilized (i) employ a novel Medium Voltage String Inverter (MVSI) topology (soft switching solid state transformer – S4T) to convert 1000 Vdc to 4.16 kVac; (ii) plant collection using standard, low-cost overhead MV distribution network; (iii) enable energy storage integration without additional converter cost to achieve dispatchability of the PV resource; and (iv) provide advanced functionality (autonomous operation, track ISO signals for dynamic balancing and ancillary services, and PV farm operation as a virtual grid resource). Subsequently and in alignment with the previously mentioned approaches, the project was structured in five efforts (i) S4T MVSI simulation and design; (ii) system analysis and storage optimization; (iii) financial analysis; (iv) power converter prototype build and test; and (v) regulatory and commercial impact study. The outcomes provided by each effort can be summarized as follows (i) Project explored the use of MV AC distribution architecture for hybrid PV+storage utility-scale PV farms; (ii) Detailed loss and LCOE analysis for AC and DC side BESS architecture, including multiple converter topologies, as well as for proposed MVSI/MDCT systems; (iii) MVSI was built and holds promise but needs lower-cost high-voltage Si-C devices, which does not seem possible in the near term; (iv) MDCT provides a simpler modular building block – validated through HIL and farm level modeling, simulation and experimental validation; (v) 300 kVA MDCT prototype built and tested, technology is being commercialized; and (vi) Regulatory model of utility building PV plants, where PV panels are treated as DC generation (IPP), seems viable and can allow improved grid integration.

14 SOLAR ENERGY↗

Measurement of Poly-Si Film Thickness on Textured Surfaces by X-Ray Diffraction in Poly-Si/SiOx Passivating Contacts for Monocrystalline Si Solar Cells

Polycrystalline Silicon on tunneling silicon oxide (poly-Si/SiOx) passivating contacts have shown great potential for the next-generation monocrystalline Si (c-Si) industrial photovoltaic technology. However, these cells typically suffer from strong parasitic absorption in the thick front poly-Si layer, which is designed to reduce metal-induced recombination. In previous work, we demonstrated an improved short-circuit current density, Jsc, by thinning the front poly-Si film in an SF6 plasma using the front metal grids as a self-aligned mask, but the sub - 100 nm thick poly-Si film is difficult to measure on an alkaline textured surface. Conventional optical techniques such as spectroscopic ellipsometry cannot be used due to the high scattering nature of the random pyramids. At poly-Si thicknesses below 50 nm, secondary electron microscopy (SEM) has difficulty distinguishing the poly-Si from the underlying c-Si substrate. Here, we demonstrate X-ray diffraction as an effective method to quantitatively measure the front poly-Si thickness. The thickness calculated from the diffraction peak height of the Si(111) crystallographic plane agrees well with the cross-section SEM analysis and simulations using SunSolve. We show that by thinning the front poly-Si from 200 to 60 nm, Jsc increased by 2.4 mA/cm2, while maintaining the same Voc. This led to an absolute efficiency gain of 1.73%. In addition, we also discuss possible reasons for the premature loss of passivation before the removal of all poly-Si, which prevented an even higher gain in Jsc.

light/electron beam induced current↗

Submicron Thickness Characterization of Poly-Si Thin Films on Textured Surfaces by X-Ray Diffraction for Minimizing Parasitic Absorption in Poly-Si/SiO2 Passivating Contact Cells

Poly-Si/SiO2 passivating contacts have shown great potential for industry-relevant next-generation solar cells. Previous work has demonstrated an improved Jsc from dry reactive ion etching in an SF6 environment, using front metal grids as a self-aligned mask. Here, we show an effective method to measure the front poly-Si thickness on an alkaline textured surface using X-ray diffraction. The calculated thicknesses are compared with cross-section SEM analysis and Quokka simulation. We show that by thinning the front poly-Si from 200 nm to 60 nm, Jsc increases by 2.4 mA/cm2, leading to an absolute efficiency gain of 1.73%. Finally, we discuss possible reasons for the premature loss of passivation before the removal of all poly-Si.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Influence of Business Models on PV-Battery Dispatch Decisions and Market Value

PV-battery hybrid projects dominate interconnection queues in some regions in the United States, but few projects have been operational long enough to assess how the hybrid capabilities may be used in practice. We interview plant operators and analyze empirical dispatch data for eleven large-scale PV-battery hybrids in three organized wholesale markets in the United States. We use the dispatch data and wholesale market prices to estimate the market value of our sample hybrids in 2020. The empirical increase in market value of a PV-battery hybrid relative to a standalone PV plant varies by project and ranges from $\$$1 to $\$$48/MWhsolar. The premium is driven by market, location, technical characteristics of the PV and battery asset, and battery dispatch strategies. In contrast to the widespread assumptions in the PV-battery hybrid modeling literature, only three of the eleven project operators optimize battery usage for wholesale market revenue as merchant plants. Instead, the majority of operators in the sample have alternate objectives. For example, load-serving entities target peak load reductions, incentive program participants focus on compliance with program requirements, and large energy consumers prioritize resiliency and utility bill minimization. Understanding prevalent dispatch signals and the degree of alignment with system-wide grid needs can increase the market value of PV-battery hybrids.

14 SOLAR ENERGY↗