Search NASA⌕ Search

SEARCH · Search NASA

Results for “high precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

High precision 5 MeV Mott polarimeter

We report on the design and performance of a Mott polarimeter optimized for a nominal 5-MeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) injector. The rf time structure of this beam allows the use of time of flight in the scattered electron detection, making it possible to cleanly isolate those detected electrons that originate from the scattering foil, and resulting in measured scattering asymmetries which are exceptionally stable over a broad range of beam conditions, beam currents, and foil thicknesses. In two separate series of measurements from two different photocathode electron sources, we have measured the Mott scattering asymmetries produced by an approximately 86% transversely polarized electron beam incident on ten gold foils with nominal thicknesses between 50 and 1000 nm. The statistical uncertainty of the measured asymmetry from each foil is below 0.25%. Within this statistical precision, the measured asymmetry was unaffected by ±1-mm shifts in the beam position on the target foil, and by beam current changes and dead-time effects over a wide range of beam currents. The overall uncertainty of our beam polarization measurement, arising from the uncertainty in the value of the scattering asymmetry at zero foil thickness as determined from our fits to the measured asymmetries versus scattering foil thicknesses, the estimated systematic effects, and the (dominant) uncertainty from the calculation of the theoretical Sherman function, is 0.61%. A simulation of the polarimeter using geant4 has confirmed that double scattering in the target foil is the sole source of the dependence of the measured asymmetry on foil thickness, and gives a result for the asymmetry versus foil thickness in good agreement with both our measurements and a simple calculation. Future measurements at different beam energies and with target foils of different atomic numbers will seek to bound uncertainties from small effects such as radiative corrections to the calculation of the polarimeter analyzing power. A simultaneous high-precision measurement of the beam polarization with a different polarimeter, AESOP (Accurate Electron Spin Optical Polarimeter), under development at the University of Nebraska, clearly possible at the CEBAF accelerator, will allow a high-precision comparison of our measured asymmetries with theoretical calculations of the Mott analyzing power. Finally, the improved precision of the current Mott polarimeter along with similar improvements to other Jefferson Lab polarimeters warrants another precision comparison of all of these polarimeters when measuring a beam of the same polarization.

Grames, J. M. (ORCID:0000000193908752)↗

High-precision millimeter-wave frequency determination through plasmonic photomixing

We present a technique for high-precision millimeter-wave frequency determination through plasmonic photomixing. Our technique utilizes a plasmonic photomixer pumped by an optical frequency comb with a high-stability millimeter-wave beat frequency. The plasmonic photomixer down-converts the millimeter-wave signal to the radio frequency regime at which high-accuracy frequency counters are available. The precision of this technique is determined by the frequency stability of the optical beat frequency, which can be directly characterized in the presented experimental setup. We demonstrate frequency measurement precision as low as 3.9×10 −10 at 95 GHz through plasmonic photomixing without phase-locking the optical frequency comb.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-precision chemical quantum sensing in flowing monodisperse microdroplets

A method is presented for high-precision chemical detection that integrates quantum sensing with droplet microfluidics. Using nanodiamonds (ND) with fluorescent nitrogen-vacancy (NV) centers as quantum sensors, rapidly flowing microdroplets containing analyte molecules are analyzed. A noise-suppressed mode of optically detected magnetic resonance is enabled by pairing controllable flow with microwave control of NV electronic spins, to detect analyte-induced signals of a few hundredths of a percent of the ND fluorescence. Using this method, paramagnetic ions in droplets are detected with low limit-of-detection using small analyte volumes, with exceptional measurement stability over >10 3 s. In addition, these droplets are used as microconfinement chambers by co-encapsulating ND quantum sensors with various analytes such as single cells, suggesting wide-ranging applications including single-cell metabolomics and real-time intracellular measurements from bioreactors. Important advances are enabled by this work, including portable chemical testing devices, amplification-free chemical assays, and chemical imaging tools for probing reactions within microenvironments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Designing polymeric membranes with coordination chemistry for high-precision ion separations

State-of-the-art polymeric membranes are unable to perform the high-precision ion separations needed for technologies essential to a circular economy and clean energy future. Coordinative interactions are a mechanism to increase sorption of a target species into a membrane, but the effects of these interactions on membrane permeability and selectivity are poorly understood. We use a multilayered polymer membrane to assess how ion-membrane binding energies affect membrane permeability of similarly sized cations: Cu 2+ , Ni 2+ , Zn 2+ , Co 2+ , and Mg 2+ . We report that metals with higher binding energy to iminodiacetate groups of the polymer more selectively permeate through the membrane in multisalt solutions than single-salt solutions. In contrast, weaker binding species are precluded from diffusing into the polymer membrane, which leads to passage proportional to binding energy and independent of membrane thickness. Our findings demonstrate that selectivity of polymeric membranes can markedly increase by tailoring ion-membrane binding energy and minimizing membrane thickness.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multidimensional, high precision beam spin asymmetry measurements of semi-inclusive pion production off the proton with CLAS12

High precision measurements of the polarized electron beam-spin asymmetry in SIDIS from the proton have been performed using a 10.6 GeV incident electron beam and the CLAS12 spectrometer at Jefferson Lab. The proceeding reports a multidimensional study of the structure function ratio F^{sin\phi}_{LU}/F_{UU} F L U s i n ϕ / F U U extracted from single pion ( \pi^{+} π + , \pi^{-} π − , \pi^{0} π 0 ) SIDIS data over a large kinematic range in z z , x_{B} x B , P_{T} P T and virtualities Q^{2} Q 2 ranging from 1~GeV ^2 2 up to 7~GeV ^2 2 . F^{sin\phi}_{LU} F L U s i n ϕ is a twist-3 quantity that can reveal novel properties of quark-gluon correlations within the nucleon.

Diehl, Stefan↗

High-precision vapor pressure measurement apparatus with facile and inexpensive construction

This study describes an apparatus for high-precision variable temperature measurement of liquid vapor pressure. The apparatus can be used to measure the vapor pressure using only 0.5 ml of the liquid sample. To evaluate the accuracy of the device measurement, water and 2-propanol are utilized as standard liquids, and their vapor pressure is measured with a maximum uncertainty of ~1%. This apparatus can be replicated using inexpensive and commonly used laboratory fittings and fixtures, making it an indispensable tool for synthetic chemists and chemical engineers involved in the iterative synthesis of compounds, targeting different vapor–liquid equilibrium regimes.

Engineering↗

High precision strike point control to support experiments in the DIII-D small angle slot divertor

Improvements in strike point control enabled tests with the new Small Angle Slot (SAS) divertor installed at DIII-D with precision as tight as ±1 mm, barring brief perturbations from ELMs. Aside from being narrower than previous baffle structures in DIII-D, simulations indicate that performance of the SAS divertor should be very sensitive to strike point position, making the improved strike point control essential for experiments with the SAS divertor. Improved control entails regulating more divertor geometry target locations than before and setting higher gain on the strike point target. This is achieved by tasking more poloidal field (PF) shaping coils with divertor topology control, fine tuning of the coil configuration and algorithm gains, and adding regulation of the power supply common rail. Here, the result is that although more variables are controlled, precision is better: high frequency jitter in the strike point position is lower on average compared to related discharges with standard divertor shape control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Siberian Snakes, Figure-8 and Spin Transparency Techniques for High Precision Experiments with Polarized Hadron Beams in Colliders

We present a review of the possibilities to conduct experiments of high efficiency in the nuclear and high energy physics with spin-polarized beams in a collider complex, configuration of which includes Siberian snakes or figure-8 collider ring. Special attention is given to the recently elicited advantageous possibility to conduct high precision experiments in a regime of the spin transparency (ST) when the design global spin tune is close to zero. In this regime, the polarization control is realized by use of spin navigators (SN), which are compact special insertions of magnets dedicated to a high flexibility spin manipulation including frequent spin flips.

43 PARTICLE ACCELERATORS↗

New loading method for high precision Sm isotope analysis of nuclear materials using thermal ionization mass spectrometry

This work demonstrates an analytical protocol for high precision Sm isotope analysis by thermal ionization mass spectrometry (TIMS) using a Pt activator. Here, the method permits precise measurements of small aliquots (1–20 ng) of Sm on single Re filament using a modified static-total evaporation technique. This study represents the first attempt to use such protocols for Sm isotope analyses while reducing the loading size of Sm for TIMS. The method could potentially be deployed to study geological, meteorites and lunar samples containing low Sm concentrations, to monitor neutron irradiation exposure based on 149,150 Sm, or to measure Sm isotopic composition in other types of nuclear samples.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A High-Precision, Fast, Robust, and Cost-Effective Muon Detector Concept for the FCC-ee

We propose a high-precision, fast, robust and cost-effective muon detector concept for an FCC-ee experiment. This design combines precision drift tubes with fast plastic scintillator strips to enable both spatial and timing measurements. The drift tubes deliver two-dimensional position measurements perpendicular to the tubes with a resolution around 100~$\mu$m. Meanwhile, the scintillator strips, read out with the wavelength-shifting fibers and silicon photomultipliers, provide fast timing information with a precision of 200~ps or better and measure the third coordinate along the tubes with a resolution of about 1~mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring isospin symmetry breaking in exotic nuclei: High-precision mass measurement of 23 Si and shell-model calculations of 𝑇 = 5/2 nuclei

Here, we present a high-precision mass measurement of the proton-rich nucleus 23 Si, performed with the LEBIT Penning trap at the Facility for Rare Isotope Beams (FRIB) utilizing the time-of-flight ion cyclotron resonance (TOF-ICR) technique. We determined a mass excess of 23362.9(5.8) keV, which agrees with a recent storage-ring measurement from the experimental Cooler-Storage Ring (CSRe) in Lanzhou but has a factor of 20 improved precision 23 Si is hence the nucleus with the most precisely known mass among all nuclei with an isospin projection of 𝑇 𝑧 = −5/2. We performed shell-model calculations with the USDC and USDCm Hamiltonians to study binding energy differences and Thomas-Ehrmann shifts in mirror systems with an isospin up to 𝑇 = 5/2. Our experimental result and other recently reported masses of neutron-deficient sd-shell nuclei agree well with the theoretical predictions, demonstrating that isospin symmetry breaking in sd-shell nuclei—even at high isospin values—is well described by modern shell-model calculations.

20 ≤ A ≤ 38↗

Ultra-Fast High-Precision Metallic Nanoparticle Synthesis using Laser-Accelerated Protons

Laser-driven proton acceleration, as produced during the interaction of a high-intensity (I > 1 × 10 18 W/cm 2 ), short pulse (<1 ps) laser with a solid target, is a prosperous field of endeavor for manifold applications in different domains, including astrophysics, biomedicine and materials science. These emerging applications benefit from the unique features of the laser-accelerated particles such as short duration, intense flux and energy versatility, which allow obtaining unprecedented temperature and pressure conditions. In this paper, we show that laser-driven protons are perfectly suited for producing, in a single sub-ns laser pulse, metallic nanocrystals with tunable diameter ranging from tens to hundreds of nm and very high precision. Our method relies on the intense and very quick proton energy deposition, which induces in a bulk material an explosive boiling and produces nanocrystals that aggregate in a plasma plume composed by atoms detached from the proton-irradiated surface. The properties of the obtained particles depend on the deposited proton energy and on the duration of the thermodynamical process. Suitably controlling the irradiated dose allows fabricating nanocrystals of a specific size with low polydispersity that can easily be isolated in order to obtain a monodisperse nanocrystal solution. Molecular Dynamics simulations confirm our experimental results.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-precision mass measurement of 103 Sn restores smoothness of the mass surface

As a step towards the ultimate goal of a high-precision mass measurement of doubly magic 100 Sn, the mass of 103 Sn was measured at the Low Energy Beam and Ion Trap (LEBIT) located at the Facility for Rare Isotope Beams (FRIB). Utilizing the time-of-flight ion cyclotron resonance technique, a mass uncertainty of 3.7 keV was achieved, an improvement by more than an order of magnitude compared to a recent measurement performed in 2023 at the Cooler Storage Ring (CSRe) in Lanzhou. Although the LEBIT and CSRe mass measurements of 103 Sn are in agreement, they diverge from the experimental mass value reported in the 2016 version of the Atomic Mass Evaluation (AME2016), which was derived from the measured 𝑄 𝛽 + value and the mass of 103 In. In AME2020, this indirectly measured 103 Sn mass was classified as a “seriously irregular mass” and replaced with an extrapolated value, which aligns with the most recent measured values from CSRe and LEBIT. As such, the smoothness of the mass surface is confidently reestablished for 103 Sn. Here, LEBIT's mass measurement of 103 Sn enabled a significant reduction in the mass uncertainties of five parent isotopes which are now dominated by uncertainties in their respective 𝑄 values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Shedding light on the 239Pu fission source term with new high-precision experiments and advanced fission modeling

In the last decade, there has been a renaissance of fission research resulting in new high-precision experiments and advanced fission modeling. For instance, the Chi-Nu and CEA teams supplied, for the first time, the 239 Pu prompt fission neutron spectrum (PFNS) for broad ranges of incident and outgoing neutron energies. The CEA team also measured 239 Pu average prompt neutron multiplicities, ν ̄ p , with lower statistical uncertainties and a technique significantly different than the one used in the past. The NIFFTE collaboration provided 239 Pu( n ,f)/ 235 U( n ,f) cross section shape ratios with uncertainties below 1% utilizing a novel detector type. Advanced fission event generators were developed, among them CGMF, FIFRELIN, FREYA, and GEF, which calculate post-scission fission observables in a correlated manner. These new experimental data and more consistent fission models change the evaluated PFNS, ν ̄ p , and ( n ,f) cross sections, some only modestly, compared to ENDF/B-VIII.0. In turn, the individual new nuclear data distinctly change simulated effective neutron multiplication factors of fast critical assemblies, but their combined impact is small, while affecting the prediction of LLNL pulsed sphere neutron leakage spectra and reaction rates only within experimental uncertainties. Also, the parameters obtained from fitting to ν ̄ p reproduce various post-scission fission observables within the uncertainties of experimental data. This indicates that new differential experiments and consistent fission modeling reduce compensating errors present in ENDF/B-VIII.0.

fission cross section↗

High-precision mass measurement of Si 24 and a refined determination of the r p process at the A = 22 waiting point

We report a high-precision mass measurement of 24 Si, performed with the Low Energy Beam and Ion Trap (LEBIT) facility at the National Superconducting Cyclotron Laboratory. The atomic mass excess, 10 753.8 (37) keV, is a factor of 5 more precise than previous results. This substantially reduces the uncertainty of the 23 Al(p ,γ) 24 Si reaction rate, which is a key part of the rapid proton capture (rp) process powering type I x-ray bursts. Furthermore, the updated rate constrains the onset temperature of the (α,p) process at the 22 Mg waiting point to a precision of 9%.

20 ≤ A ≤ 38↗

High-Precision Low-Cost Micro Birdbath Resonating Gyroscope (CRADA Final Report)

As part of the Cyclotron Road program, Enertia Microsystems Inc. (EMI) investigated a high-performance micro mechanical resonator called the micro birdbath resonator and a high-precision micro electromechanical systems (MEMS) gyroscope called the birdbath resonator gyroscope (BRG). The BRG is a novel fused-silica MEMS gyroscope. The BRG can obtain significantly greater accuracy, comparable size, and comparable cost with MEMS gyroscopes made of silicon that are currently on the market.

47 OTHER INSTRUMENTATION↗

High-precision shock equation of state measurements for metallic fluid carbon between 15 and 20 Mbar

Diamond is an efficient ablator material to convert the energy of high-power giant lasers into ablation pressure with applications for High-Energy-Density (HED) science, planetary science, and Inertial Confinement Fusion (ICF) research at the National Ignition Facility (NIF). Unfortunately, current theoretical equation of state models cannot reproduce all the observed experimental data in the multi-megabar regime particularly relevant for HED and ICF research. New experimental data on the behavior of carbon at extreme pressures and temperatures are, therefore, essential to improve our predictive capability to design and analyze dynamic compression experiments for HED or ICF research and build improved equation of state models in the future. In this paper, we report high-precision laser-driven shock compression measurements on diamond single crystals at the Omega Laser Facility. Using ultrafast Doppler optical Velocimetry Interferometer System for Any Reflector (VISAR) to track the leading shock front and a quartz plate as an in situ reference, we obtain relative pressure-density shock equation-of-state measurements between 15 and 20 Mbar with an impedance-matching procedure. We also report shock-and-release measurements in a spherical geometry at the NIF. The new data provide tight constraints on the compressibility of warm dense carbon along the Hugoniot of full density diamond, allowing us to discriminate between existing theoretical equation-of-state models. We find that both LLNL LEOS 9061 and LANL Sesame 7835 models capture well the shock compressibility in the explored range. LANL Sesame 7835 also reproduces well the observed shock-and-release behavior of diamond near 10–20 Mbar.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A modular apparatus for use in high-precision measurements of parity violation in polarized eV neutron transmission

We describe a modular apparatus for use in parity-violation measurements in epithermal neutron–nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos National Laboratory. This apparatus is designed to conduct high-precision measurements of the parity-odd transmission asymmetry of longitudinally polarized neutrons through targets containing nuclei with p-wave neutron–nucleus resonances in the 0.1–10 eV energy regime and to accommodate a future search for time reversal violation in polarized neutron transmission through polarized nuclear targets. The apparatus consists of an adjustable neutron and gamma collimation system, a 3 He- 4 He ion chamber neutron flux monitor, two identical cryostats for target cooling, an adiabatic eV-neutron spin flipper, a near-unit efficiency 6 Li- 7 Li scintillation detector operated in current mode, a flexible CAEN data acquisition system, and a neutron spin filter based on spin-exchange optical pumping of 3 He gas. We describe the features of the apparatus design devoted to the suppression of systematic errors in parity-odd asymmetry measurements. We describe the configuration of the apparatus used to conduct a precision measurement of parity violation at the 0.7 eV p-wave resonance in 139 La which employs two identical 139 La targets, one to polarize the beam on the p-wave resonance using the weak interaction and one to analyze the polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗