Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Cherenkov imaging method for rapid optimization of clinical treatment geometry in total skin electron beam therapy

Purpose: A method was developed utilizing Cherenkov imaging for rapid and thorough determination of the two gantry angles that produce the most uniform treatment plane during dual-field total skin electron beam therapy (TSET). Methods: Cherenkov imaging was implemented to gather 2D measurements of relative surface dose from 6 MeV electron beams on a white polyethylene sheet. An intensified charge-coupled device camera time-gated to the Linac was used for Cherenkov emission imaging at sixty-two different gantry angles (1° increments, from 239.5° to 300.5°). Following a modified Stanford TSET technique, which uses two fields per patient position for full body coverage, composite images were created as the sum of two beam images on the sheet; each angle pair was evaluated for minimum variation across the patient region of interest. Cherenkov versus dose correlation was verified with ionization chamber measurements. The process was repeated at source to surface distance (SSD) = 441, 370.5, and 300 cm to determine optimal angle spread for varying room geometries. In addition, three patients receiving TSET using a modified Stanford six-dual field technique with 6 MeV electron beams at SSD = 441 cm were imaged during treatment. Results: As in previous studies, Cherenkov intensity was shown to directly correlate with dose for homogenous flat phantoms (R{sup 2} = 0.93), making Cherenkov imaging an appropriate candidate to assess and optimize TSET setup geometry. This method provided dense 2D images allowing 1891 possible treatment geometries to be comprehensively analyzed from one data set of 62 single images. Gantry angles historically used for TSET at their institution were 255.5° and 284.5° at SSD = 441 cm; however, the angles optimized for maximum homogeneity were found to be 252.5° and 287.5° (+6° increase in angle spread). Ionization chamber measurements confirmed improvement in dose homogeneity across the treatment field from a range of 24.4% at the initial angles, to only 9.8% with the angles optimized. A linear relationship between angle spread and SSD was observed, ranging from 35° at 441 cm, to 39° at 300 cm, with no significant variation in percent-depth dose at midline (R{sup 2} = 0.998). For patient studies, factors influencing in vivo correlation between Cherenkov intensity and measured surface dose are still being investigated. Conclusions: Cherenkov intensity correlates to relative dose measured at depth of maximum dose in a uniform, flat phantom. Imaging of phantoms can thus be used to analyze and optimize TSET treatment geometry more extensively and rapidly than thermoluminescent dosimeters or ionization chambers. This work suggests that there could be an expanded role for Cherenkov imaging as a tool to efficiently improve treatment protocols and as a potential verification tool for routine monitoring of unique patient treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Exact-image method for Gaussian-beam problems involving a planar interface

The exact-image method, recently introduced for the solution of electromagnetic field problems involving sources above a planar interface between two homogeneous media, is shown to be valid also for sources located in complex space, which makes its application possible for Gaussian-beam analysis. It is demonstrated that the Goos-Hanchen shift and the angular shift of a TE-polarized beam are correctly given as asymptotic results by the exact-reflection-image theory. Also, the apparent-image location giving the correct Gaussian beam transmitted through the interface is obtained as another asymptotic check. The theory described here makes it possible to calculate the exact coupling from the Gaussian beam to the reflected and refracted beams as well as to the surface wave.

Lindell, Ismo V.↗

A comparison of earthquake backprojection imaging methods for dense local arrays

Backprojection imaging has recently become a practical method for local earthquake detection and location due to the deployment of densely sampled, continuously recorded, local seismograph arrays. While backprojection sometimes utilizes the full seismic waveform, the waveforms are often pre-processed and simplified to overcome imaging challenges. Real data issues include aliased station spacing, inadequate array aperture, inaccurate velocity model, low signal-to-noise ratio, large noise bursts and varying waveform polarity. We compare the performance of backprojection with four previously used data pre-processing methods: raw waveform, envelope, short-term averaging/long-term averaging and kurtosis. Our primary goal is to detect and locate events smaller than noise by stacking prior to detection to improve the signal-to-noise ratio. The objective is to identify an optimized strategy for automated imaging that is robust in the presence of real-data issues, has the lowest signal-to-noise thresholds for detection and for location, has the best spatial resolution of the source images, preserves magnitude, and considers computational cost. Imaging method performance is assessed using a real aftershock data set recorded by the dense AIDA array following the 2011 Virginia earthquake. Our comparisons show that raw-waveform backprojection provides the best spatial resolution, preserves magnitude and boosts signal to detect events smaller than noise, but is most sensitive to velocity error, polarity error and noise bursts. On the other hand, the other methods avoid polarity error and reduce sensitivity to velocity error, but sacrifice spatial resolution and cannot effectively reduce noise by stacking. Of these, only kurtosis is insensitive to large noise bursts while being as efficient as the raw-waveform method to lower the detection threshold; however, it does not preserve the magnitude information. For automatic detection and location of events in a large data set, we therefore recommend backprojecting kurtosis waveforms, followed by a second pass on the detected events using noise-filtered raw waveforms to achieve the best of all criteria.

58 GEOSCIENCES↗

Single-Transducer, Ultrasonic Imaging Method for High-Temperature Structural Materials Eliminates the Effect of Thickness Variation in the Image

NASA Lewis Research Center's Life Prediction Branch, in partnership with Sonix, Inc., and Cleveland State University, recently advanced the development of, refined, and commercialized an advanced nondestructive evaluation (NDE) inspection method entitled the Single Transducer Thickness-Independent Ultrasonic Imaging Method. Selected by R&D Magazine as one of the 100 most technologically significant new products of 1996, the method uses a single transducer to eliminate the superimposing effects of thickness variation in the ultrasonic images of materials. As a result, any variation seen in the image is due solely to microstructural variation. This nondestructive method precisely and accurately characterizes material gradients (pore fraction, density, or chemical) that affect the uniformity of a material's physical performance (mechanical, thermal, or electrical). Advantages of the method over conventional ultrasonic imaging include (1) elimination of machining costs (for precision thickness control) during the quality control stages of material processing and development and (2) elimination of labor costs and subjectivity involved in further image processing and image interpretation. At NASA Lewis, the method has been used primarily for accurate inspections of high temperature structural materials including monolithic ceramics, metal matrix composites, and polymer matrix composites. Data were published this year for platelike samples, and current research is focusing on applying the method to tubular components. The initial publicity regarding the development of the method generated 150 requests for further information from a wide variety of institutions and individuals including the Federal Bureau of Investigation (FBI), Lockheed Martin Corporation, Rockwell International, Hewlett Packard Company, and Procter & Gamble Company. In addition, NASA has been solicited by the 3M Company and Allison Abrasives to use this method to inspect composite materials that are manufactured by these companies.

Roth, Don J.↗

A review of quantum imaging methods and enabling technologies

The field of quantum imaging has recently seen an explosion of new methods and techniques. At the heart of most quantum imaging approaches are three enabling technologies: the source of the quantum light, the detectors that turn sensing into imaging, and the method by which the quantum nature of light is leveraged to improve the desired measurement. This review addresses the dominant and emerging technologies in each of these components as well as details concerning the implementations of various quantum imaging methods.

36 MATERIALS SCIENCE↗

Combining hyperspectral imaging and micro-X-ray fluorescence imaging methods for ultra-high-resolution biogeochemical analysis

Current non-destructive methods for high-resolution geochemical imaging open new avenues for high-resolution paleoenvironmental research. We discuss how two of these methods, hyperspectral imaging and micro-X-ray fluorescence imaging, can be combined for organic and inorganic geochemical analyses at a micrometer scale.

Zander, Paul [Lawrence Livermore National Laborato↗

Protein-based nanobubble x-ray imaging method and agent

Systems, compositions, methods and kits employ protein shells, such as ferritin or viral capsid shells, herein called nanobubbles, to enhance X-ray images of cells or body tissue under certain x-ray imaging methods. The nanobubbles have sub-micron size such as about 10 nm, about 40, 60, or 100 nm and may be functionalized for effective delivery to or uptake by a target tissue, in vivo or a cell culture. The nanobubbles are hollow, having a central core which may be empty or contain a fluid, such that the shells effectively form long-lived bubbles in the imaged environment, and are of low electron density and have different scattering properties than the surrounding tissue. X-ray imaging by spatial frequency heterodyne imaging enhances visualization or detection of tissue regions bearing the shells. The protein shells may be further treated to assure biocompatibility and/or to resist undesired interactions with non-targeted tissue, such as scavenging by the liver, or attack by the immune system. For example the nanobubbles may be filled with a hydrophobic gas such as perfluoropropane (octafluoropropane) to maintain their shape and resist hydrophilic interactions and delay the degradation of the protein shells. The nanobubbles may also be coated or treated by a surface-functionalization processes to effectively target specific tissues or tumor types, allow parenteral delivery, and/or deliver drugs or other agents to the imaged sites—so that when visualized by X-ray scatter imaging the presence of the nanobubbles indicates the existence and extent of the tumor or diseased tissue.

Rose-Petruck, Christoph↗

Visualization and imaging methods for flames in microgravity

The visualization and imaging of flames has long been acknowledged as the starting point for learning about and understanding combustion phenomena. It provides an essential overall picture of the time and length scales of processes and guides the application of other diagnostics. It is perhaps even more important in microgravity combustion studies, where it is often the only non-intrusive diagnostic measurement easily implemented. Imaging also aids in the interpretation of single-point measurements, such as temperature, provided by thermocouples, and velocity, by hot-wire anemometers. This paper outlines the efforts of the Microgravity Combustion Diagnostics staff at NASA Lewis Research Center in the area of visualization and imaging of flames, concentrating on methods applicable for reduced-gravity experimentation. Several techniques are under development: intensified array camera imaging, and two-dimensional temperature and species concentrations measurements. A brief summary of results in these areas is presented and future plans mentioned.

Weiland, Karen J.↗

A novel transient infrared imaging method for non-intrusive, low-cost, fast, and accurate air leakage detection in building envelopes

Air leakage through the building envelope in the U.S. accounts for about four quads of energy annually, costing approximately $40 billion per year. However, a high-fidelity and non-intrusive method to detect air leakage has not been demonstrated to date. Here, in this paper, we propose a novel non-intrusive and low-cost method called Transient Infrared (IR) Imaging (TIRI) that can rapidly and accurately identify air leakage locations and relative rates on building envelopes. When the interior and exterior temperatures are different, and a small internal pressure pulse is created by HVAC, the temperature at locations with air leakages will change rapidly, while the areas without a leakage do not change. Based on a heat transfer model, we have derived the temperature change as a function of time after the HVAC is turned on. By tracking the temperature change, which depends on leakage rate and size, we have obtained the air leakage map in the case studies. Using an exterior door as an example, we took transient IR images in different seasons and different times of the day, and successfully obtained the leakage map in all the scenarios. Successfully obtained the air leakage map even when the indoor-outdoor air temperature difference is as small as 2 °C. We have also realized a detection speed of 10s and demonstrated that this method also worked for windows, which have mirror-like IR reflections. Our TIRI method will accelerate the improvement of airtightness in buildings, save building energy, and help reduce greenhouse gas emissions.

42 ENGINEERING↗

Quantification of Pediatric Abdominal Organ Motion With a 4-Dimensional Magnetic Resonance Imaging Method

Purpose: To characterize respiration-induced abdominal organ motion in children receiving radiation treatment with a 4-dimensional (4D) magnetic resonance imaging (MRI) method. Methods and Materials: We analyzed free-breathing coronal 4D MRI datasets acquired from 35 patients (aged 1-20 years) with abdominal tumors. A deformable image registration of the 4D MRI datasets was performed to derive motion trajectories of selected anatomic landmarks, from which organ motions were quantified. The association between organ motion and patient characteristics was investigated and compared with previous studies. The relation between patient height and organ motion was further investigated to predict organ motion in prospective patients. Results: Organ motion and its individual variation were reduced in younger patients (eg, kidney peak-to-peak motion <5 mm for all but 1 patient aged ≤8 years), although special motion management may be warranted in some adolescents. The liver and spleen exhibited greater motion than did the kidneys, while intraorgan variation was present. The motions in the liver and kidneys agreed with those reported by the previous 4D computed tomography studies. Individual variations of organ motion in younger patients were due, in part, to changes in respiration rate, which ostensibly reflected the effect of anesthesia. The prediction of organ motion was limited by large individual variations, particularly for older patients. Conclusions: The 4D MRI acquisition method and motion analysis described in this study provide a nonionizing approach to understand age-associated organ motion, which aids in the planning of abdominal radiation therapy for pediatric patients. Use of 4D MRI facilitates monitoring of changes in target motion patterns during treatment courses and in various studies of the effect of organ motion on radiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray imaging methods for high-energy density physics applications

Large scale high-energy density science facilities continue to grow in scale and complexity worldwide. The increase in driver capabilities, including pulsed-power and lasers, continue to push the boundaries of temperature, pressure, and densities, opening up new physics regimes. X-ray imaging is one of the many diagnostic techniques that are used to probe states of matter in these extreme conditions. Improved fabrication and polishing methods have provided improved x-ray microscope performance, while improving detector and x-ray sources now enable pico-second imaging with few micron resolutions. Here this Review will cover x-ray imaging methods, primarily absorption imaging, and their improvements over the last few decades.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection of Objects Hidden in Highly Scattering Media Using Time-Gated Imaging Methods

Non-intrusive and non-invasive optical imaging techniques has generated great interest among researchers for their potential applications to biological study, device characterization, surface defect detection, and jet fuel dynamics. Non-linear optical parametric amplification gate (NLOPG) has been used to detect back-scattered images of objects hidden in diluted Intralipid solutions. To directly detect objects hidden in highly scattering media, the diffusive component of light needs to be sorted out from early arrived ballistic and snake photons. In an optical imaging system, images are collected in transmission or back-scattered geometry. The early arrival photons in the transmission approach, always carry the direct information of the hidden object embedded in the turbid medium. In the back-scattered approach, the result is not so forth coming. In the presence of a scattering host, the first arrival photons in back-scattered approach will be directly photons from the host material. In the presentation, NLOPG was applied to acquire time resolved back-scattered images under the phase matching condition. A time-gated amplified signal was obtained through this NLOPG process. The system's gain was approximately 100 times. The time-gate was achieved through phase matching condition where only coherent photons retain their phase. As a result, the diffusive photons, which were the primary contributor to the background, were removed. With a large dynamic range and high resolution, time-gated early light imaging has the potential for improving rocket/aircraft design by determining jets shape and particle sizes. Refinements to these techniques may enable drop size measurements in the highly scattering, optically dense region of multi-element rocket injectors. These types of measurements should greatly enhance the design of stable, and higher performing rocket engines.

Galland, Pierre A.↗

Phase-contrast imaging method based on fast Kerr optical nonlinearity of air

The visualisation of a transparent phase object (gas jet) and the brightness inversion at the image of a nontransparent amplitude object (metal wire) is implemented using the nonlinear phase-contrast method based on the fast Kerr nonlinearity of the ambient air. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectral ratio imaging methods for geological remote sensing from aircraft and satellites

An improved photogrammetric technique (scannergrammetry) for the production of ratio images from multispectral scanner data is described. The multispectral technique is less affected by variations in atmospheric and solar illumination levels than single-channel scanner imagery of aerial photographs. Another advantage of the multispectral technique is the proportionality between ratios of a target deduced from ratio images, on the one hand, and ratios of reflectances calculated from laboratory spectra of samples from the target area, on the other hand. Several representative ratio images from aircraft and satellite data in the visible, reflective IR, and thermal IR regions are included. The geological applications suggested for ratio scannergrammetry include exploration of construction materials, soils, stratigraphy, volcanic ash flows, beaches, and sand dunes.

Vincent, R. K.↗

Spectral ratio imaging methods for geological remote sensing from aircraft and satellites

The author has identified the following significant results. The production of ratio images from multispectral scanner data is described and several examples of ratio images from aircraft and ERTS-1 data are given for visible, reflective infrared, and thermal infrared wavelengths. The application of photogrammetric techniques to ratio images, defined for this paper as ratio scannergrammetry, is considerably aided by the lesser dependence of ratio images on atmospheric and solar illumination variations, compared with single channel scanner imagery or aerial photos. Ratio scannergrammetry is further aided by the proportionality between ratios of a target deduced from ratio images and ratios of reflectances calculated from laboratory spectra of samples from the target area. Consequently, ratios calculated from laboratory data can be used to predict which ratios are best for discriminating a given rock or mineral, to predict what other rocks or minerals will be confused with it, and finally, to place ratio scannergrammetry on an absolute basis, within an estimated standard error on the order of 5% to 10%. Examples of relative agreement between laboratory data and ratio images are given from two iron oxides, hematite and magnetite.

Vincent, R. K.↗

A comparison of imaging methods for use in an array biosensor

An array biosensor has been developed which uses an actively-cooled, charge-coupled device (CCD) imager. In an effort to save money and space, a complementary metal-oxide semiconductor (CMOS) camera and photodiode were tested as replacements for the cooled CCD imager. Different concentrations of CY5 fluorescent dye in glycerol were imaged using the three different detection systems with the same imaging optics. Signal discrimination above noise was compared for each of the three systems.

Evaluation Studies↗