Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Development of intelligent control module for the J-TEXT electron cyclotron emission imaging system

An Electron Cyclotron Emission Imaging (ECEI) system has been developed on the J-TEXT tokamak and employed for the multi-dimensional electron temperature fluctuation imaging measurement in 2019 campaign. The intelligent control module has been developed and been used to flexibly setup the 256-channel ECEI system configurations for different plasma scenarios. The adjustments of key parameters are merged in this module including size and position of the geometric observation window, and the dynamic range of the signal and image resolution. The user-friendly interface is also developed for the tokamak operator to set the ECEI system focusing on physics interested region. Furthermore, this module is installed close to the diagnostic system around the J-TEXT tokamak, which can be remotely controlled by authorized operators in the control room. It significantly improves ECEI flexibility and stability, and also keeps the operation technician away from the harsh radiation environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Advanced Imaging Systems for High-Resolution and Event-Mode Detection

Post-irradiation examination (PIE) is a continually growing field critical to the development of improved nuclear fuels. To characterize these materials, neutron imaging systems are employed and outfitted with, typically, CMOS or CCD cameras - complementary metal oxide semiconductor sensors and charge-couple devices. Imaging systems are a team-effort between the camera, scintillating materials, and object of interest, as a result of neutrons' inherent need to be converted to a detectable signal. High resolution imaging, flash radiography imaging, and event-mode detection systems are three systems undergoing development, construction, and characterization for improved spatial resolution and time-of-flight detection for PIE efforts.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Plasmonics-Enhanced Optical Imaging Systems for Bioenergy Research

This final report summarizes the key accomplishments of the project entitled “Plasmonics-Enhanced Optical Imaging Systems for Bioenergy Research”. The goal of this project is aimed at developing innovative and improved imaging instrumentation for visualization and quantitative characterization of biomarkers related to molecular processes and cellular function in living plants. This project focused on three specific aims: 1) Development of Advanced Multimodal Optical Sensing And Imaging Combinatory (MOSAIC) System for SERS biosensing and bioimaging. 2) Evaluation of MOSAIC technologies for sensing and imaging gene expression in plant systems using plasmonic nanoprobes. 3) Application of MOSAIC techniques to bioenergy research.

47 OTHER INSTRUMENTATION↗

Developing a camera-based 3D momentum imaging system capable of 1 Mhits/s

A camera-based three-dimensional (3D) imaging system with a superb time-of-flight (TOF) resolution and multi-hit capability was recently developed for electron/ion imaging [Lee et al. J. Chem. Phys. 141, 221101 (2014)]. In this work, we report further improvement of the event rate of the system by adopting an event-driven camera, Tpx3Cam, for detecting the 2D positions of electrons, while a high-speed digitizer provides highly accurate (~30 ps) TOF information for each event at a rate approaching 1 Mhits/sec.

47 OTHER INSTRUMENTATION↗

Dual modality endocavity biopsy imaging system and method

A dual modality endocavity imaging and treatment system for detection of cancer and targeted biopsy and treatment procedures, comprising: a housing; a nuclear detector system housed within the housing and configured for detecting nuclear radiation imaging data; an ultrasound detector system housed within the housing for detecting ultrasound imaging data; a needle associated with the housing and adjustably positionable relative thereto; and a data processing module configured to receive the nuclear radiation imaging data and the ultrasound imaging data and to generate and output an image showing the relative position of the needle and an endocavity object of interest. The needle may include a distinct radiation signature to facilitate imaging thereof.

Lall, Terrence↗

The Bimodal Absorption System Imaging Campaign (BASIC). I. A Dual Population of Low-metallicity Absorbers at z < 1

The bimodal absorption system imaging campaign (BASIC) aims to characterize the galaxy environments of a sample of 36 H I-selected partial Lyman limit systems (pLLSs) and Lyman limit systems (LLSs) in 23 QSO fields at z ≲ 1. These pLLSs/LLSs provide a unique sample of absorbers with unbiased and well-constrained metallicities, allowing us to explore the origins of metal-rich and low-metallicity circumgalactic medium (CGM) at z < 1. Here we present Keck/KCWI and Very Large Telescope/MUSE observations of 11 of these QSO fields (19 pLLSs) that we combine with Hubble Space Telescope/Advanced Camera for Surveys imaging to identify and characterize the absorber-associated galaxies at 0.16 ≲ z ≲ 0.84. We find 23 unique absorber-associated galaxies, with an average of one associated galaxy per absorber. For seven absorbers, all with <10% solar metallicities, we find no associated galaxies with logM * ≳ 9.0 within ρ/R vir and |Δv|/v esc ≤ 1.5 with respect to the absorber. We do not find any strong correlations between the metallicities or H I column densities of the gas and most of the galaxy properties, except for the stellar mass of the galaxies: the low-metallicity ([X/H] ≤ –1.4) systems have a probability of $0.39_{–0.15}^{+0.16}$ for having a host galaxy with logM * ≥ 9.0 within ρ/R vir ≤ 1.5, while the higher metallicity absorbers have a probability of $0.78_{–0.13}^{+0.10}$. This implies metal-enriched pLLSs/LLSs at z < 1 are typically associated with the CGM of galaxies with logM * > 9.0, whereas low-metallicity pLLSs/LLSs are found in more diverse locations, with one population arising in the CGM of galaxies and another more broadly distributed in overdense regions of the universe. Using absorbers not associated with galaxies, we estimate the unweighted geometric mean metallicity of the intergalactic medium to be [X/H] ≲ –2.1 at z < 1, which is lower than previously estimated.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of an optical imaging system prototype for autonomously monitoring zooplankton in an aquaculture facility

Traditional approaches to biomonitoring in aquatic systems, such as sample collection, sorting, and identification, require significant time and effort, thereby limiting the spatiotemporal resolution of sample collection. Additionally, collection and preservation of samples for subsequent taxonomic identification and enumeration leads to mortality of organisms. Recent advances in technologies that utilize optical imaging and machine learning have provided new opportunities to expedite biomonitoring and lead to significant cost savings. These technologies can be advantageous to scientists or managers that conduct routine biomonitoring to inform operations, as in the case of aquaculture facilities. The Small Aquatic Organism optical imaging system (SAO) is a high-throughput optical imaging and classification prototype system that relies on computer vision and machine learning (Support Vector Machines, or SVMs) to autonomously identify and enumerate aquatic organisms. The SAO provides a more sustainable method of collecting large volumes of data and has the benefit of being used in situ. In this study, we tested the performance of the SAO in providing comparable results to manual zooplankton community monitoring in ten ponds at an aquaculture facility. We performed a side-by-side study comparing the sampling methods of plankton tow nets, where major zooplankton taxonomic classes were manually identified and enumerated, to sampling with the SAO. Vouchered samples were used to develop a training library for the SAO, where classes consisted of water boatman and zooplankton groups: cladocerans, copepod adults, copepod nauplii, and rotifers. SAO imagery was manually classified and compared with predicted results for validation. Accuracy for the SVM classifier of the SAO was 37.4 %. Convolutional Neural Networks (CNN) and Random Forest classifiers were also applied to SAO imagery and image features for comparison. The best CNN model and our Random Forest model had accuracies of 80.4 % and 46.6 % respectively. Challenges faced included the small size of copepod nauplii and rotifers and the limited resolution of the imaging camera, although there are tradeoffs between imaging resolution and the sample processing rate. Furthermore, our comparison shows that advancement in both optical imaging and ML are needed in order for the SAO prototype to yield comparable results to manual community monitoring in an aquaculture facility.

54 ENVIRONMENTAL SCIENCES↗

Ultra-Wideband Microwave Imaging System for Root Phenotyping

The roots are a vital organ for plant growth and health. The opaque surrounding environment of the roots and the complicated growth process means that in situ and non-destructive root phenotyping face great challenges, which thus spur great research interests. The existing methods for root phenotyping are either unable to provide high-precision and high accuracy in situ detection, or they change the surrounding root environment and are destructive to root growth and health. Thus,we propose and develop an ultra-wideband microwave scanning method that uses time reversal to achieve in situ root phenotyping nondestructively. To verify the method’s feasibility, we studied an electromagnetic numerical model that simulates the transmission signal of two ultra-wideband microwave antennas. The simulated signal of roots with different shapes shows the proposed system’s capability to measure the root size in the soil. Experimental validations were conducted considering three sets of measurements with different sizes, numbers and locations, and the experimental results indicate that the developed imaging system was able to differentiate root sizes and numbers with high contrast. The reconstruction from both simulations and experimental measurements provided accurate size estimation of the carrots in the soil, which indicates the system’s potential for root imaging.

59 BASIC BIOLOGICAL SCIENCES↗

A multi-mass and multi-hit two-camera 3D ion momentum imaging system

We demonstrate an improved two-camera system for multi-mass and multi-hit three-dimensional (3D) momentum imaging of ions. The imaging system employs two conventional complementary metal–oxide–semiconductor cameras. We have shown previously that the system can time slice ion Newton spheres with a time resolution of 8.8 ns, limited by camera timing jitter [J. Chem. Phys., 158, 191104 (2023)]. In this work, a jitter correction method was developed to suppress the camera jitter and improve the time resolution to better than 2 ns. With this resolution, full 3D momentum distributions of ions can be obtained. We further show that this method can detect two ions with different masses when utilizing both the rising and falling edges of the cameras.

Instruments & Instrumentation↗

Stereo-vision thermal imaging system for tracking flying animals in wind farm areas (CRADA #763) Abstract

CRADA 763: abstract ThermalTracker-3D (TT3D) is a stereo vision thermal imaging system that provides 3D flight information on detected birds, bats, and other flying targets. The system was initially developed for use in the siting and monitoring of offshore wind projects to establish pre-construction and operation collision risk data but can be applied to terrestrial wind energy projects as well as national security monitoring. This technology will reduce monitoring cost, decrease processing time, and provide more accurate data for wind energy developers/operators and regulatory agencies. While the current technology is at a high level of readiness, Technology Readiness Level (TRL) 7, there remain several barriers to commercialization, particularly around ease-of-use, that result in a low Adoption Readiness Level (ARL). The proposed work will advance commercialization readiness by streamlining calibration methods for built systems. This work will:1. 1. develop a software package for factory and dynamic calibration processes 2. test that package with existing prototype TT3D systems, and 3. conduct outreach with industry end-users.

ThermalTracker↗

CAMIS: A Cylindrical Active Mask Imaging System

Detecting and locating radiological and nuclear materials at distances of 10 m or more in urban and cluttered environments continues to pose challenges in nuclear security and proliferation detection. Previous approaches have focused on large-area radiation imaging using planar configurations of detectors and passive masks. However, these approaches suffer from limitations such as limited field-of-view (FOV) and reduced detection efficiency due to absorption in the mask. To address these limitations, we have developed the cylindrical active mask imaging system (CAMIS). This system comprises 128 NaI(Tl) (10 cm)3 detectors. These detectors are arranged in a cylindrical configuration, enabling gamma-ray imaging with a full 360° azimuthal FOV. The active mask elements within the system are arranged in a pseudorandom configuration, providing unique encoding for all incident directions within the FOV. CAMIS offers an effective detection area of approximately 1 m2 across the entire 360° FOV in the horizontal plane, achieving a mean angular resolution of 10.9° in the azimuthal direction and 12.9° in the polar direction measured by taking the full-width at half-maximum (FWHM) of a cross-section at the maximum reconstructed intensity.

Lamb, C↗

Compact imaging system using a co-linear, high-intensity LED illumination unit to minimize window reflections for background-oriented schlieren, shadowgraph, photogrammetry and machine vision measurements

One aspect of the present disclosure is an imaging system including an optical sensor defining an optical axis. The system further includes a light source. The system may include an optical beam splitter, and may also include an optional diffusing lens that may be configured to diffuse and/or collimate light from the light source and direct light exiting the diffusing lens to the optical beam splitter. The optical beam splitter is configured to direct light from the light source along the optical axis of the optical sensor.

Bathel, Brett F.↗

Inverse rendering of fusion plasmas: Inferring plasma composition from imaging systems

In this work, we develop a differentiable rendering pipeline for visualising plasma emission within tokamaks, and estimating the gradients of the emission and estimating other physical quantities. Unlike prior work, we are able to leverage arbitrary representations of plasma quantities and easily incorporate them into a non-linear optimisation framework. The efficiency of our method enables not only estimation of a physically plausible image of plasma, but also recovery of the neutral Deuterium distribution from imaging and midplane measurements alone. We demonstrate our method with three different levels of complexity showing first that a poloidal neutrals density distribution can be recovered from imaging alone, second that the distributions of neutral Deuterium, electron density and electron temperature can be recovered jointly, and finally, that this can be done in the presence of realistic imaging systems that incorporate sensor cropping and quantisation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

HyperKube: A Kubernetes Based System for the Automation of Processing and Analysis of Hyperspectral Data Obtained from Multiple Hyperspectral Imaging Systems

Hyperspectral imagery is an emerging field of technology that has enormous potential for remote and proximal sensing in numerous areas of research. The plant phenotyping community is applying this technology to advance the throughput and accuracy of plant phenotypes based on airborne and lab-based hyperspectral imaging technology. Here we report an automated processing and analysis pipeline for four different hyperspectral imaging platforms, discuss the data issues involved, and present a strategy for computing and data architecture to handle hyperspectral data.

47 OTHER INSTRUMENTATION↗

Preliminary Design Needs for High-Temperature Heat Pipe Imaging System

This report provides preliminary design needs for radiological imaging heat pipes to perform in operando assessment for high-temperature alkaline metal charged heat pipes (HPs). The measurement parameters of interest have been summarized for characterizing the operando HP behavior. Based on the current SPHERE experimental facility, the needs and modifications required for the experimental setup have also been identified to enable the X-ray-assisted visualizations for the single HP during its operating conditions.

42 ENGINEERING↗

Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System From Adaptive Detector Movements

To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

An all-digital associated particle imaging system for the 3D determination of isotopic distributions

Associated particle imaging (API) is a non-destructive nuclear technique for the 3D determination of isotopic distributions. By detecting the alpha particle associated with the emitted neutron in the deuterium–tritium fusion reaction with a position- and time-resolving detector, the direction of the 14.1 MeV neutron and its time of emission can be determined. Employing this method, isotope characteristic gamma rays emitted in inelastic neutron scattering events can be correlated with the neutron interaction location. Here, an API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector was designed, constructed, and characterized. The system was tested with common soil elements and shown to be sensitive to 12 C, 16 O, 28 Si, 27 Al, and 56 Fe. New aspects of our approach are the use of a yttrium–aluminum–perovskite scintillator, using a sapphire window instead of a fiber-optic faceplate for light transport to the photomultiplier, and the all-digital data acquisition system. We present a description of the system with simulations and experimental results that show a position resolution on the alpha detector of 1 mm, a depth resolution using a LaBr 3 detector of 6.2 cm, and an angular resolution of 4.5°. Additionally, we present single-element gamma response measurements for the elements mentioned above together with a comparison to Monte Carlo simulations (MCNP6).

47 OTHER INSTRUMENTATION↗