Search NASA⌕ Search

SEARCH · Search NASA

Results for “infrared gas analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Characterization of plasma catalytic decomposition of methane: role of atomic O and reaction mechanism

In this work, we investigated atmospheric pressure plasma jet (APPJ)-assisted methane oxidation over a Ni-SiO 2 /Al 2 O 3 catalyst. We evaluated possible reaction mechanisms by analyzing the correlation of gas phase, surface and plasma-produced species. Plasma feed gas compositions, plasma powers, and catalyst temperatures were varied to expand the experimental parameters. Real-time Fourier-transform infrared spectroscopy was applied to quantify gas phase species from the reactions. The reactive incident fluxes generated by plasma were measured by molecular beam mass spectroscopy using an identical APPJ operating at the same conditions. A strong correlation of the quantified fluxes of plasma-produced atomic oxygen with that of CH 4 consumption, and CO and CO 2 formation implies that O atoms play an essential role in CH 4 oxidation for the investigated conditions. With the integration of APPJ, the apparent activation energy was lowered and a synergistic effect of 30% was observed. We also performed in-situ diffuse reflectance infrared Fourier-transform spectroscopy to analyze the catalyst surface. The surface analysis showed that surface CO abundance mirrored the surface coverage of CH n at 25 °C. This suggests that CH n adsorbed on the catalyst surface as an intermediate species that was subsequently transformed into surface CO. We observed very little surface CH n absorbance at 500 °C, while a ten-fold increase of surface CO and stronger CO 2 absorption were seen. This indicates that for a nickel catalyst at 500 °C, the dissociation of CH 4 to CHn may be the rate-determining step in the plasma-assisted CH 4 oxidation for our conditions. We also found the CO vibrational frequency changes from 2143 cm –1 for gas phase CO to 2196 cm –1 for CO on a 25 °C catalyst surface, whereas the frequency of CO on a 500 °C catalyst was 2188 cm –1 . Here, the change in CO vibrational frequency may be related to the oxidation of the catalyst.

methane oxidation↗

Study of electron-induced chemical transformations in polymers

In extreme ultraviolet (EUV) photoresist exposure, the primary and secondary electrons drive chemistry rather than the EUV photons themselves. These electrons have a wide range of energies below approximately 80 eV, which are capable of complex network of reactions during exposure. To better understand the ability of electrons of different energies within the EUV primary and secondary electron range, we want to characterize and compare the chemistry induced in pure polymer films by direct exposure to electrons. Thin films of poly(tert-butyl methacrylate), poly(methyl methacrylate), and poly(4-hydroxystyrene) were exposed to a 20 to 80 eV electron beam. Outgassing during exposure was characterized in-situ using a quadrupole residual gas analyzer. The thickness changes were measured using ellipsometry and chemical bond structure data were collected using Fourier-transform infrared spectroscopy (FTIR) after exposure to compare different exposure conditions. Poly(4-hydroxystyrene) demonstrated stability during electron exposures. Exposures of the other two materials led to outgassing of protecting groups, the intensity of which decayed in time. Outgassing, FTIR, and thickness loss data exhibited approximately linear relationships to each other.

Mueller, Maximillian↗

A new approach for measuring the carbon and oxygen content of atmospherically relevant compounds and mixtures

Abstract. Due to its complexity, gas- and particle-phase organic carbon in the atmosphere is often classified by its bulk physicochemical properties. However, there is a dearth of robust, moderate-cost approaches to measure the bulk chemical composition of organic carbon in the atmosphere. This is particularly true for the degree of oxygenation, which critically affects the properties and impacts of organic carbon but for which routine measurement approaches are lacking. This gap has limited the understanding of a wide range of atmospheric components, including particulate matter, the mass of which is monitored worldwide due to its health and environmental effects but the chemical characterization of which requires relatively high capital costs and complex operation by highly trained technical personnel. In this work, we demonstrate a new approach to estimate the mass of carbon and oxygen in analytes and mixtures that relies only on robust, moderate-cost detectors designed for use with gas chromatography. Organic compounds entering a flame ionization detector were found to be converted with approximately complete efficiency to CO2, which was analyzed downstream using an infrared detector to measure the mass of carbon analyzed. The ratio of the flame ionization detector (FID) signal generated to CO2 formed (FID∕CO2) was shown to be strongly correlated (R2=0.89) to the oxygen-to-carbon ratio (O∕C) of the analyte. Furthermore, simple mixtures of analytes behaved as the weighted average of their components, indicating that this correlation extends to mixtures. These properties were also observed to correlate well with the sensitivity of the FID estimated by structure activity relationships (quantified as the relative effective carbon number). The relationships between measured FID∕CO2, analyte O∕C, and FID sensitivity allow the estimation of one property from another with <15 % error for mixtures and <20 % error for most individual analytes. The approach opens the possibility of field-deployable, autonomous measurement of the carbon and oxygen content of particulate matter using time-tested, low-maintenance detectors, though such an application would require some additional testing on complex mixtures. With some instrumental modifications, similar measurements on gas-phase species may be feasible. Moreover, the potential expansion to additional gas chromatography detectors may provide concurrent measurement of other elements (e.g., sulfur, nitrogen).

42 ENGINEERING↗

In Situ Atmospheric Plume Thermometry via Carbon Monoxide Spectral Profile: Laboratory and Field Validation

For small molecules with large rotational constants, knowing the relative intensities of the ro-vibrational transitions can be used to determine the temperature within a gas plume. We demonstrate the use of carbon monoxide (CO) as an in situ spectroscopic probe of gas plume temperature by application of both laboratory and standoff Fourier transform infrared spectroscopy to monitor the CO spectral response at different temperatures. Here, the measured CO rotational contours were analyzed using a simple Boltzmann model to deduce the population distribution of the J-levels, from which the in-plume temperature is deduced. The method was vetted by comparing deduced temperatures in both static laboratory measurements of known temperatures, as well as field measurements using a simulated smokestack release. For the smokestack experiments, spectroscopically deduced temperatures were compared to readings from a series of thermocouples placed at strategically sampled distances along the plume trajectory. Both the spectroscopically-derived and thermocouple-measured temperatures revealed an expansion-induced (mixing) rapid cooling of the plume, with the infrared thermometry values displaying greater temperature values which are believed to better represent the actual plume temperatures.

Analysis of rotational structure↗

NOx speciation from copper dissolution in nitric acid/water solutions using FTIR spectroscopy

The speciation of NO 2 , NO, and N 2 O gases formed from the dissolution of copper in nitric acid is measured and characterized using Fourier-transform infrared (FTIR) spectroscopy. This study describes analysis of the gas phase species formed and ingrowths of their concentrations as a function of time. Acid concentrations range from 14 to 4 M and the NO 2 , NO, and N 2 O are analyzed using FTIR between 1585 and 2209 wavenumbers. The concentrations of the gases range from 0 to 230 ppm and change over time and as a function of acid concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing Thermal Transport in Fluidized Bed Using Modulated Photothermal Radiometry

Abstract In concentrated solar power (CSP) applications, fluidized bed is a promising approach for high heat transfer coefficient (HTC) solar receivers and heat exchangers. However, the complexity of multiphase mixing has made it difficult to characterize and analyze the heat transfer mechanism. This paper presents an experimental study on simultaneously characterizing heat transfer in both the near-wall and the bulk regions of a fluidized bed using modulated photothermal radiometry (MPR). The MPR is a non-contact frequency-domain technique using an intensity-modulated laser as the heat source and surface infrared emission as thermometry. The thermal penetration depth of the laser heating is varied by controlling its modulation frequency, and thus the measurement can resolve the near-wall and the bulk thermal resistances. With the MPR technique, we measured fluidized silica sands with a mean size of 164 μm in a vertical channel of 6 mm depth. Our results show that the near-wall thermal resistance is substantially increased with increasing gas velocity, which partially offsets the benefit of higher HTC brought by stronger particle mixing during the fluidization. We also used the MPR to quantify the improvement in particle-wall heat transfer in an inclined channel. We found that an 8° inclination towards the heat exchanging side led to a lower near-wall thermal resistance and a higher HTC at high gas velocities. This work demonstrates that the MPR technique is a useful tool to quantify the important near-wall thermal resistance from a bulk particle bed, which not only advances our understanding of heat transfer in fluidized beds, but may also contribute to the design of fluidized bed heat exchangers with higher HTC.

14 SOLAR ENERGY↗

Generation of isolated soft x-ray attosecond pulses with mid-infrared driving lasers via transient phase-matching gating

Abstract Isolated attosecond pulses (IAPs) in the soft x-ray (SXR) region are highly desirable for attosecond time-resolved experiments. Here we identify a transient phase matching gating method for the generation of such IAPs with mid-infrared (MIR) lasers. This gating method works when a loosely focused, long-duration MIR Gaussian driving beam is slightly reshaped during its propagation in the gas medium under the ‘critical’ ionization condition. Quantitatively, the calculated coherence length of high harmonic is used to analyze the mechanism of the gating method, by using one-dimensional plane-wave beams and by comparing 2000 nm and 800 nm lasers. The robustness of the generation method is checked by varying laser’s carrier-envelope-phase and gas pressure. This gating method provides with an alternative route to efficiently produce tabletop ultrashort attosecond SXR light sources with the emerging MIR lasers.

Physics↗

High-resolution infrared spectroscopy of jet cooled cyclobutyl in the α-CH stretch region: large-amplitude puckering dynamics in a 4-membered ring radical

We report gas-phase cyclobutyl radical (c-C 4 H 7 ) is generated at a rotational temperature of T rot = 26(1) K in a slit-jet discharge mixture of 70% Ne/30% He and 0.5–0.6% cyclobromobutane (c-C 4 H 7 Br). A fully rovibrationally resolved absorption spectrum of the α-CH stretch fundamental band between 3062.9 cm −1 to 3075.7 cm −1 is obtained and analyzed, yielding first precision structural and dynamical information for this novel radical species. The α-CH stretch band origin is determined to be 3068.7887(4) cm −1 , which implies only a modest (≈0.8 cm −1 ) blue shift from rotationally unresolved infrared spectroscopic studies of cyclobutyl radicals in liquid He droplets [ A. R. Brown, P. R. Franke and G. E. Douberly, J. Phys. Chem. A , 2017, 121 , 7576–7587]. Of particular dynamical interest, a one-dimensional potential energy surface with respect to the ring puckering coordinate is computed at CCSD(T)/ANO2 level of theory and reveals a double minimum C s puckered geometry, separated by an exceedingly shallow planar C 2v transition state barrier (E barr ≈ 1 cm −1 ). Numerical solutions on this double minimum potential yield a zero-point energy for the ground state (E zero-point ≈ 27 cm −1 ) greatly in excess of the interconversion barrier. This is indicative of highly delocalized, large amplitude motion of the four-membered ring structure, for which proper vibrationally averaging of the moment of inertia tensor reproduces the experimentally determined inertial defect remarkably well. Finally, intensity alternation in the experimental spectrum due to nuclear spin statistics upon exchange of three indistinguishable H atom pairs (IH = ½) matches K a + K c = even : odd = 36 : 28 predictions, implying that the unpaired electron in the radical center lies in an out-of-plane p π orbital. Thus, high-resolution infrared spectroscopy provides first experimental confirmation of a shallow double minimum ring puckering potential with a highly delocalized ground state wave function peaked at a planar C 2v transition state geometry consistent with a cyclobutyl π radical.

Chemistry↗

Ammonia Permeation Through Inorganic Membranes

Moisture probes are used in the tritium facility to measure the moisture content of the gas stream. When tritium reacts with nitrogen to form ammonia, the ammonia gas damages the sensitive moisture probe. The gas stream tested during this experiment for moisture probe protection is composed of nitrogen and argon gas in conjunction with ammonia and water vapor. The gas stream is filtered through an inorganic membrane due to the high reactivity of tritium and a residual gas analyzer (RGA) is used to measure the ammonia and water vapor in the gas stream, as well as the permeability of nitrogen and argon through the inorganic membranes. The membranes tested were boron nitride and silver. The permeability was compared for each membrane at different pressures and flow rates. Fourier-transformed infrared spectroscopy (FT-IR) was used to compare the membranes before and after ammonia permeation. Ammonia gas is a byproduct formed from tritium gas reacting with nitrogen in the gas stream, similar to the Haber Process which occurs when hydrogen reacts with nitrogen [2]. The corrosive nature of ammonia damages metals and sensitive instruments such as moisture probes. Moisture probes are essential in various gas and liquid processes for measuring the moisture content of a gas. Membrane research has found that graphene oxide membranes successfully uptake ammonia from the gas stream at a humidity of approximately 30% at which point the pores pin closed, preventing gas permeation. Further research is being conducted to find an inorganic membrane that will prevent ammonia permeation thus circumventing damage to the sensitive moisture probe. The permeation measurements for argon and nitrogen gas and water and ammonia vapor were measured at various pressures of 800, 1000, 1200, 1500, 1800, and 2000 torr. The permeability average (PA) was calculated for each filter using a Barrer calculation. The average permeations for each filter were then compared. The gas composition was measured using the RGA Nitrogen was permeated through the membranes after ammonia permeation and a FT-IR spectrum was obtained. Boron Nitride: As the nitrogen pressure increased, the permeability of the membrane decreased from 800-1200 torr and remained relatively unchanged from 1200-2000 torr. The membrane exhibited a slight decrease in argon permeability from 800-1200 torr and a slight increase from 1500-2000 torr. The boron nitride membrane when permeated with ammonia and nitrogen prevented less ammonia permeation compared to the blank filter. The boron nitride filter demonstrated a decrease in permeability after ammonia permeation. Silver Membrane: When permeated with nitrogen alone, the membrane permeability decreased from 800 torr to 1200 torr. The permeability of the membrane showed little difference as pressure increased from 1200 torr. When permeated with argon, the same phenomenon occurred but on a much smaller scale. When compared to the blank and the boron nitride membranes the silver membrane exhibited significantly lower permeability. This may be in part due to the coating on the silver membrane and differences in pore size of the membranes. During permeation with ammonium hydroxide vapor and nitrogen, the partial pressure of the ammonia increased as compared to the blank membrane. The permeability before and after permeation with ammonia and nitrogen were compared. Permeability values suggested that after being permeated with the ammonia that the permeability for lower pressures increased slightly. There was no significant change in the FT-IR spectrums before and after permeation. Future work: Continue testing various inorganic membranes for ammonia permeation. Further research chemical separation of ammonia from the gas stream, which may prove difficult due to the high reactivity of tritium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Situ Characterization of Surface Recombination in p-Si/SiO x Based Photoelectrochemical Cells

Time-resolved infrared (TRIR) and electrochemical impedance spectroscopy (EIS) were utilized to quantify surface states present at silicon oxide (SiO x ) protected crystalline p-Si electrolyte interfaces. The primary goal was to identify p-Si/SiO x photoelectrodes with both low surface recombination rates and efficient multi-electron transfer to an acceptor present in the external electrolyte. Three SiO x layers were investigated: native oxide (nOx), chemical oxide (cOx), and rapid thermal annealed (RTA) thermal oxide (tOx). Comparative study with [Ru(bpy) 3 ](PF 6 ) 2 as the electron acceptor indicated that tOx was most optimal with a small effective recombination rate, multi-electron transfer capability, and photovoltage of 500 ± 50 mV. A secondary goal was to analyze the surface recombination rates with the Shockley–Read–Hall (SRH) kinetic model. Two surface states were identified from this analysis, one closer to the CB edge (V t,1 ) and the other near the midgap (V t,2 ). EIS and SRH analyses revealed that a forming gas (5% H 2 /N 2 ) anneal (FGA) decreased surface recombination for tOx and nOx through a lower density of surface states. In the case of tOx, the infrared data indicated that V t,2 was completely removed. Here, the energetic positions of the band edges were correlated with the surface state density; low densities corresponded to more favorable potentials for inversion layer formation, which is expected to be most optimal for photocatalysis. Collectively this study indicates that the free carrier dynamics provided by TRIR represent a powerful in situ probe of the band edge and the surface state energetics in silicon based photoelectrochemical cells.

Electrochemical Impedance Spectroscopy↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

Aerosol Microphysics and Chemical Measurements at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024 UCSD Library Collection

This dataset includes guest instrument measurements and other PI products for aerosol microphysics and chemical measurements collected at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024. The measurements include the following instruments at Mt. Soledad: High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS, Aerodyne), Scanning Electrical Mobility Spectrometer (SEMS, Brechtel Manufacturing Inc.), Aerodynamic Particle Sizer (APS, Droplet Measurements Technologies), Single Particle Soot Photometer (SP2, Drople Measurements Technologies), Meteorological Station (WXT520, Vaisala), Ozone (Teco), and trace gas proxies (Teledyne). In addition, the analyses of particle filters collected at Mt. Soledad for three dry-diameter size cuts (<1 micron, <0.5 micron, <0.18 micron) and at Scripps Pier for one dry-diameter size cut (<1 micron) by Fourier Transform Infrared (FTIR) and X-ray Fluorescence (XRF) are reported. A differential mobility analyzer operated as a scanning mobility particle sizer (SMPS, TSI Inc.), a printed particle optical spectrometer (POPS, Grimm), and a continuous flow diffusion cloud condensation nuclei (CCN, DMT) counter provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. Measurements are reported for both sampling from an isokinetic aerosol inlet and from a Counterflow Virtual Impactor (CVI, Brechtel Manufacturing Inc.). The data are available at the following link: https://library.ucsd.edu/dc/collection/bb0898306q

54 ENVIRONMENTAL SCIENCES↗

A Near-infrared Look at AGN Feedback in Bulgeless Galaxies

While it is generally believed that supermassive black holes (SMBHs) lie in most galaxies with bulges, few SMBHs have been confirmed in bulgeless galaxies. Identifying such a population could provide important insights to the BH seed population and secular BH growth. To this end, we obtained near-infrared (NIR) spectroscopic observations of a sample of low-redshift bulgeless galaxies with mid-infrared colors suggestive of active galactic nuclei (AGNs). We find additional evidence of AGN activity (such as coronal lines and broad permitted lines) in 69% (9/13) of the sample, demonstrating that mid-infrared selection is a powerful tool to detect AGNs. More than half of the galaxies with confirmed AGN activity show fast outflows in [O III ] in the optical and/or [Si vi] in the NIR, with the latter generally having much faster velocities that are also correlated to their spatial extent. We are also able to obtain virial BH masses for some targets and find they fall within the scatter of other late-type galaxies in the M BH –M stellar relation. The fact that they lack a significant bulge component indicates that secular processes, likely independent of major mergers, grew these BHs to supermassive sizes. Finally, we analyze the rotational gas kinematics and find two notable exceptions: two AGN hosts with outflows that appear to be rotating faster than expected. There is an indication that these two galaxies have stellar masses significantly lower than expected from their dark matter halo masses. This, combined with the observed AGN activity and strong gas outflows, may be evidence of the effects of AGN feedback.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of Sub-Ppm Instrument Response Suggests Higher Detection Limits Could Be Used to Quantify Methane Emissions from Oil and Gas Infrastructure

Quantifying and controlling fugitive methane emissions from oil and gas facilities remains essential for addressing climate goals, but the costs associated with monitoring millions of production sites remain prohibitively expensive. Current thinking, supported by measurement and simple dispersion modelling, assumes single-digit parts-per-million instrumentation is required. To investigate instrument response, the inlets of three trace-methane (sub-ppm) analyzers were collocated on a facility designed to release gas of known composition at known flow rates between 0.4 and 5.2 kg CH 4 h –1 from simulated oil and gas infrastructure. Methane mixing ratios were measured by each instrument at 1 Hertz resolution over nine hours. While mixing ratios reported by a cavity ring-down spectrometer (CRDS)-based instrument were on average 10.0 ppm (range 1.8 to 83 ppm), a mid-infrared laser absorption spectroscopy (MIRA)-based instrument reported short-lived mixing ratios far larger than expected (range 1.8 to 779 ppm) with a similar nine-hour average to the CRDS (10.1 ppm). We suggest the peaks detected by the MIRA are likely caused by a micrometeorological phenomenon, where vortex shedding has resulted in heterogeneous methane plumes which only the MIRA can observe. Further analysis suggests an instrument like the MIRA (an optical-cavity-based instrument with cavity size ≤10 cm3 measuring at ≥2 Hz with air flow rates in the order of ≤0.3 slpm at distances of ≤20 m from the source) but with a higher detection limit (25 ppm) could detect enough of the high-concentration events to generate representative 20 min-average methane mixing ratios. Even though development of a lower-cost, high-precision, high-accuracy instrument with a 25 ppm detection threshold remains a significant problem, this has implications for the use of instrumentation with higher detection thresholds, resulting in the reduction in cost to measure methane emissions and providing a mechanism for the widespread deployment of effective leak detection and repair programs for all oil and gas infrastructure.

03 NATURAL GAS↗

Antifoam Development for Eliminating Flammability Hazards and Decreasing Cycle Time in the Defense Waste Processing Facility

Foam, due to the high gas generation rates of boiling and chemical reaction offgasing, requires control measures to prevent the foam from contaminating the condensate and to facilitate efficient plant operation. Antifoam was utilized to minimize foam production during chemical processing in the DWPF and during High-Level Waste (HLW) evaporation at SRS and Hanford. However, the current antifoam used in the SRS DWPF increases flammability risk during chemical processing (generates three flammable degradation products) and while feeding the melter (can decompose to CO/hydrogen). It is also the likely source of methyl functional groups for the organo-mercury present in the tank farm and excessive mercury in Saltstone. Additionally, the planned startup of Salt Waste Processing Facility (SWPF), with much higher throughput, will challenge DWPF to process at higher gas generation rates. DWPF employs Antifoam 747, a superspreader produced by Momentive Performance Materials, as an antifoaming agent during waste processing. During DWPF chemical processing, antifoam must be effective up to boiling (i.e., up to 103°C) and between a pH of 3-13. Antifoam 747 is most effective at a pH range of 6-8 and degrades as pH deviates. In addition, SRNL identified three flammable antifoam degradation products using mass spectrometer (MS) and fourier transform infrared (FTIR) offgas analyzers during simulations. A new antifoam or a new method to control foam is needed to minimize DWPF processing time and reduce the risk of contamination. In addition, testing should be completed to ensure that other antifoams used in HLW processing do not have similar flammability hazards or cause unintended impacts in downstream processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Hydrogen Burner for FT4000® Aeroderivative Engine - Final Report

This report details an effort to develop a retrofittable fuel/air injector for the FT4000® aeroderivative gas turbine that enables use of hydrogen as a carbon-free fuel for efficient power generation. The FT4000 engine’s low-NOx combustor was developed by Pratt & Whitney and RTX Technology Research Center with core technology from the Pratt & Whitney PW4000 turbofan aircraft engine. The current FT4000 production engine operates on either natural gas or No. 2 fuel oil with water injection to achieve high thermal efficiency and low emissions. This engine is fielded by Mitsubishi Power Aero and delivers 70 MW of power with a simple-cycle efficiency of over 41% when operating with wet compression. The work reported here advances the technology readiness level of the FT4000 combustor for operation with hydrogen, starting with an experimental assessment of the current production hardware with increasing hydrogen content mixed with natural gas and ending with improved nozzle concepts for fully robust operation with 100% hydrogen. High-pressure single-sector combustor rig tests have been completed, demonstrating the ability for the dual fuel nozzle to operate an FT4000 combustor on 100% hydrogen with low nitrogen oxide (NOx) emissions. Metal temperature measurements and video images of the flame structure from zero to 100% hydrogen highlight opportunities to improve the fuel nozzle robustness for high hydrogen conditions. The design of new fuel/air mixer concepts to improve durability and operability with high hydrogen levels was also completed. A total of eleven new concepts were developed and analyzed, ranging from modifications to the bill-of-materials nozzle to fully clean sheet designs. The concepts were evaluated with non-reacting and reacting flow evaluations to assess the performance of the new hardware designs. Non-reacting tests included Phase Doppler Particle Analysis (PDPA) for droplet size and velocity, mechanical patternation for liquid water flux, and planar laser induced fluorescence (PLIF) with acetone-seeding for gaseous fuel/air mixing characterization. Five scaled candidate fuel nozzle designs, in addition to a scaled bill-of-materials nozzle, were then successfully evaluated in an atmospheric pressure burner rig. The nozzles were evaluated for performance with natural gas, hydrogen/natural gas blends, and pure hydrogen. For 100% hydrogen, the nozzles were evaluated with and without water injection. Optical and infrared imaging of the flame and fuel nozzle was captured. NOx emissions were sampled from fixed emissions probes. The results show measurable differences between the various designs, and the data was used to down-select the two most promising designs to advance to future full pressure rig testing. Results from this study have cleared the current production FT4000 engines with dual fuel nozzles to operate at baseload power on blends of hydrogen mixed with natural gas and water. Two promising nozzle designs have been developed to enable fully robust operation with up to 100% hydrogen. These nozzles require validation at full baseload operating conditions before they can be introduced to the field.

03 NATURAL GAS↗

Phase-matching analysis in high-order harmonic generation with nonzero orbital angular momentum Laguerre-Gaussian beams

Through high-order harmonic generation driven by intense ultrashort vortex infrared or midinfrared lasers, a nonzero orbital angular momentum can be imprinted onto extreme ultraviolet (XUV) or soft-x-ray (SXR) light pulses. Here we simulate the generation of vortex XUV harmonics in the gas medium as well as their propagation in vacuum till reaching the far field. In this work, we find that the intensity and phase of generated high harmonics are very sensitive to the position of gas jet with respect to the laser focus. The topological charge of the $\textit{q}$th harmonic is found to be $\textit{q}$ times that of the driving Laguerre-Gaussian beam. Each harmonic in the far field appears as a single ring in the transverse plane with an invariant diameter which is scalable with the fundamental topological charge only when the gas jet is placed after the laser focus. The underlying phase-matching mechanism is analyzed by examining the spatial map of the coherence length and by calculating the evolution of harmonic emission in the medium. We anticipate this work to stimulate interest in generating intense vortex XUV or SXR attosecond pulses for probing dynamics of molecules where special molecular features are difficult to be detected with linear or circular XUV or SXR pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗