Search NASA⌕ Search

SEARCH · Search NASA

Results for “installer magnetic field”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Dedicated beam position monitor pair for model-independent lattice characterization at NSLS-II

This paper reports recent lattice characterization results obtained at the National Synchrotron Light Source II (NSLS-II) storage ring, conducted without reliance on a lattice model. A pair of beam position monitors (BPMs) with bunch-by-bunch (B$\times$B) resolution, were recently installed in a section of the storage ring free of magnetic fields. The new BPM pair measured the beam, or bunch’s transverse Poincaré map precisely after the beam was excited. Linear one-turn-matrices (OTM) were then derived, and from these, the 4-dimensional coupled Twiss parameters were extracted at the locations of the BPM pair. By normalizing beam oscillation amplitudes with the Twiss parameters, the global action-variables were obtained. Additionally, these action-variables facilitated the measurement of the local Twiss parameters observed by other BPMs independent on lattice model. This method is general, and particularly useful in certain scenarios such as a round beam mode in a diffraction-limited light source ring. We applied it to assess both weakly and strongly coupled lattices at the NSLS-II ring. Through analysis of the strongly coupled lattice, the quadrupole tilt errors were estimated to be less than 400 μrad. Utilizing the BPMs’ B$\times$B resolution, for the first time we observed the variations of the linear lattice along a long bunch-train.

36 MATERIALS SCIENCE↗

A magnetic diagnostic suite for the Pegasus-III experiment

Pegasus-III is an ultralow aspect ratio spherical tokamak providing a dedicated US experiment for comparative solenoid-free startup studies. A new magnetic diagnostic suite for equilibrium and low frequency (<200 kHz) magnetohydrodynamic mode analysis has been installed. These new diagnostics address the significant challenges of measuring magnetic field in a high noise environment with the majority constrained to fit in an 8 mm diagnostic gap on the high field side. Electrostatic switching noise generated by the 16 independent current feedback-controlled power supplies produces dV cm /dt ~ 1 kV/μs and volt level common mode noise on the magnetics. Immunity to this switching noise is accomplished through differential signal runs and signal processing, along with end-to-end electromagnetic interference shielding. The magnetic measurements are simultaneously digitized at 1 MHz and conditioned by precision 8 pole Butterworth filters with a corner frequency of 200 kHz to prevent aliasing down to the 16-bit level over the full passband. Ex-vessel calibrations of the B p coils were completed with a typical uncertainty of <0.5%. Stray toroidal field pickup from coil misalignment or positioning errors is corrected using a physics-based model. Comparisons of the corrected measurements to modeling agree to within 1.3% on average. This is within the 1.5% measurement uncertainty that a sensitivity analysis determined is needed for accurate fast boundary and equilibrium reconstruction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dedicated beam position monitor pair for model-independent lattice characterization at NSLS-II

This paper reports recent lattice characterization results obtained at the National Synchrotron Light Source II (NSLS-II) storage ring, conducted without reliance on a lattice model. A pair of beam position monitors (BPMs) with bunch-by-bunch (B×B) resolution, were recently installed in a section of the storage ring free of magnetic fields. The new BPM pair measured the beam, or bunch’s transverse Poincar´e map precisely after the beam was excited. Linear one-turn-matrices (OTM) were then derived, and from these, the 4-dimensional coupled Twiss parameters were extracted at the locations of the BPM pair. By normalizing beam oscillation amplitudes with the Twiss parameters, the global action-variables were obtained. These action-variables facilitated the measurement of the local Twiss parameters observed by other BPMs independent on lattice model. This method is general, and particularly useful in certain scenarios such as a round beam mode in a diffraction-limited light source ring. We applied it to assess both weakly and strongly coupled lattices at the NSLS-II ring. Through analysis of the strongly coupled lattice, the quadrupole tilt errors were estimated to be less than 400 µrad. Utilizing the BPMs’ B×B resolution, for the first time we observed the variations of the linear lattice along a long bunch-train.

43 PARTICLE ACCELERATORS↗

System-on-chip integrated circuit technology applications on the DIII-D tokamak for multi-field measurements

Several mm-wave diagnostics on the DIII-D tokamak provide multi-scale and multi-dimensional measurements of plasma profile evolution and turbulence fluctuations. Mm-wave fusion plasma diagnostics that adopt system-on-chip integrated circuit technology can provide better space utilization, flexible installation, and improved sensitivity. In order to further extend this technology for additional fusion facilities with a higher toroidal magnetic field, V-band (55–75 GHz) and F-band (90–140 GHz) chips for Microwave Imaging Reflectometer (MIR) and Electron Cyclotron Emission Imaging (ECEI) instruments are developed and tested in the Davis Millimeter Wave Research Center (DMRC). Current measurement data show that correlation between these SoC-based diagnostic instruments with other state-of-the-art diagnostics enables co-located multi-field turbulence fluctuation measurement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of the MQXFB Nb 3 Sn Quadrupoles for the HL-LHC

Here, the cold powering test of the first two prototypes of the MQXFB quadrupoles (MQXFBP1, now disassembled, and MQXFBP2), the Nb 3 Sn inner triplet magnets to be installed in the HL-LHC, has validated many features of the design, such as field quality and quench protection, but has found performance limitations. In fact, both magnets showed a similar phenomenology, characterized by reproducible quenches in the straight part inner layer pole turn, with absence of training and limiting the performance at 93% (MQXFBP1) and 98% (MQXFBP2) of the nominal current at 1.9 K, required for HL-LHC operation at 7 TeV. Microstructural inspections of the quenching section of the limiting coil in MQXFBP1 have identified fractured Nb 3 Sn sub-elements in strands located at one specific position of the inner layer pole turn, allowing to determine the precise origin of the performance limitation. In this paper we outline the strategy that has been defined to address the possible sources of performance limitation, namely coil manufacturing, magnet assembly and integration in the cold mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PyCCE: A python package for custer correlation expansion simulations of spin qubit dynamics.

PyCCE, an open-source Python library for simulating the dynamics of spin qubits in a spin bath, is presented using the cluster-correlation expansion (CCE) method. PyCCE includes modules to generate realistic spin baths, employing coupling parameters computed from first principles with electronic structure codes, and enables the user to run simulations with either the conventional or generalized CCE method. Three use cases of the Python library are illustrated: the calculation of the Hahn-echo coherence time of the nitrogen-vacancy in diamond; the calculation of the coherence time of the basal divacancy in silicon carbide at avoided crossings; and the calculation for magnetic field orientation-dependent dynamics of a shallow donor in silicon. The complete documentation, downloadable tutorials, and installation instructions are available at https://pycce.readthedocs.io/en/latest/.

coherence↗

The High Luminosity LHC interaction region magnets towards series production

The High Luminosity Large Hadron Collider (HL-LHC) is the new flagship project of CERN. First endorsed in 2013 and approved in 2016, HL-LHC is an upgrade of the accelerator aiming to increase by a factor of ten the statistics of the LHC collisions at the horizon of 2035-2040. HL-LHC relies on cutting edge technologies: among them, large aperture superconducting magnets will replace the present hardware to allow a smaller beam size in two interaction points (IPs). The project involves the construction of about 150 magnets of six different types: the quadrupole triplet, two main dipoles and three orbit correctors. The triplet, manufactured at CERN and in the USA, will consist of 30 magnets based on Nb3Sn technology, with an operational peak field of 11.4 T. These will be the first quadrupole Nb3Sn magnets installed in a particle accelerator. The other five types of magnets, all relying on Nb-Ti technology, present non-trivial challenges in the design and construction; they will be manufactured as part of in-kind contribution under the responsibility of institutes in Japan, China, Spain, and Italy. The project is now in the phase of transition between qualification through short models and prototypes and the beginning of the series construction. In this paper we review the magnet requirements, the reasons for selecting the design, the technological challenges with respect to previous projects, and we summarize the steps that have been taken to validate the baseline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a magnetic field monitoring system for the MAGIS-100 experiment

The MAGIS-100 collaboration is building a long-baseline atom interferometer designed to investigate dark matter, novel forces, gravitational waves, and quantum science. A major design challenge is external, time-varying magnetic fields, the effect of which can mimic gravitational waves or expected dark matter signals; static magnetic fields must also be tightly controlled to manage measurement resolution. Several tools are being applied to the problem, including mu-metal shielding, field biasing, and a suite of magnetometers. This report details the development of a magnetic field monitoring system to be built from commercially available parts and installed at seventeen locations, one for each of the modular sections making up the length of the MAGIS-100 apparatus.

Arce, Edwin [Unlisted, US, CA]↗

Development of magnetic field monitoring system for the MAGIS-100 experiment

The MAGIS-100 collaboration is building a long-baseline atom interferometer designed to investigate dark matter, novel forces, gravitational waves, and quantum science. A major design challenge is external, time-varying magnetic fields, the effect of which can mimic gravitational waves or expected dark matter signals. Several mitigations will be enacted, including mu-metal shielding and a suite of magnetometers. This presentation will discuss the development of a magnetic field monitoring system based on commercial magneto-inductive sensors to be installed at several points along the interferometer.

Arce, Edwin [Unlisted; Fermilab]↗

AUP first Pre-series Cold Mass Installation into the Cryostat

For the Hi-Lumi LHC Upgrade (HL-LHC) new high field and large-aperture quadrupole magnets for the low-beta inner triplets (Q1, Q2, Q3) are being built. These new quadrupole magnets are based on Nb3Sn superconducting technology. As part of the US-HiLumi Accelerator Upgrade Project (AUP) ten Cryostat Assemblies (LQXFA) for Q1 and Q3 replacement will be built, tested and delivered to CERN. The first of the LQXFA was assembled and tested at Fermi National Accelerator Laboratory (FNAL) during the fall of 2022 and spring 2023. We will present the integration work of the Cold Mass assembly into the Cryostat Kit provided by CERN. Each Cold Mass contains two trained MQXFA magnets of ~ 5 m length installed in a stainless-steel helium pressure vessel. The Cold Mass will be surrounded by cryostat shields, piping, and vacuum vessel. We will discuss the metrology survey results and present the LQXFA measurements prior testing at the Fermilab Magnet Test facility and lessons learned.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An e-beam irradiation beamline at Jefferson Lab for 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS) remediation in wastewater

The Upgraded Injector Test Facility (UITF) at Jefferson Lab, providing a beam energy up to 10 MeV, is suitable for wastewater remediation research. To investigate the degradation of 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS), widespread in wastewater and potential to be regulated in near future, a beamline for electron-beam irradiation has been designed, installed and successfully commissioned at the UITF. A solenoid with a peak axial magnetic field of up to 0.28 T and a raster were used to obtain a Gaussian beam profile with a transverse standard deviation of 15 mm. It was applied to irradiate 1,4-dioxane sample filled in the target cell that was designed to let the entire sample receive significant irradiation doses. The dose distribution and absorbed dose, few studied in the current publications, are necessary measures for the degradation mechanism investigation and have been innovatively achieved in this work using simulations which were calibrated with opti-chromic dosimeter rods directly exposed to the electron beam. This approach provides an important way for investigating the environmental remediation impact of electron-beam irradiation.

Li, Xi↗

Diagnostic development for parallel wave-number measurement of lower hybrid waves in EAST

An eight-channel magnetic probe diagnostic system has been designed and installed adjacent to the 4.6 GHz lower hybrid (LH) grill antenna in the low-field side of the EAST tokamak in order to study the n|| evolution of lower hybrid waves in the first pass from the launcher to the core plasma. The magnetic probes are separated by 6.6 mm, which allows measurement of the dominant parallel refractive index n|| up to n|| =5 for 4.6GHz LH waves. The magnetic probes are designed to be sensitive to the magnetic field component perpendicular to the background magnetic field with a slit on the casing that encloses the probe. The intermediate frequency (IF) stage, which consists of two mixing stages, down-coverts the frequency of the measured wave signals at 4.6 GHz to 20 MHz. A bench test demonstrates the phase stability of the magnetic probe diagnostic system. By evaluating the phase variation of the measured signals along the background magnetic field, the dominant n|| of the LH wave in the scrape-off layer (SOL) has been deduced during the 2019 experimental campaign. In the low density plasma, the measured dominant n|| of the lower hybrid waves is about 2.1, corresponding to the main peak 2.04 of the launched n|| spectrum. The n|| deduced by the least square linear fit method remains near this value in the low density plasma with a high spatial correlation magnitude of 0.9. With an eight-channel probe system a wave-number spectrum has also been deduced, which has a peak near to the measured dominant n||.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic development for parallel wave-number measurement of lower hybrid waves in EAST

In this study, an eight-channel magnetic probe diagnostic system has been designed and installed adjacent to the 4.6 GHz lower hybrid (LH) grill antenna in the low-field side of the Experimental Advanced Superconducting Tokamak (EAST) in order to study the n ∥ evolution of LH waves in the first pass from the launcher to the core plasma. The magnetic probes are separated by 6.6 mm, which allows measurement of the dominant parallel refractive index n ∥ up to n ∥ = 5 for 4.6 GHz LH waves. The magnetic probes are designed to be sensitive to the magnetic field component perpendicular to the background magnetic field with a slit on the casing that encloses the probe. The intermediate frequency stage, which consists of two mixing stages, down-coverts the frequency of the measured wave signals at 4.6 GHz to 20 MHz. A bench test demonstrates the phase stability of the magnetic probe diagnostic system. By evaluating the phase variation of the measured signals along the background magnetic field, the dominant n ∥ of the LH wave in the scrape-off layer has been deduced during the 2019 experimental campaign. In the low density plasma, the measured dominant n ∥ of the LH waves is about 2.1, corresponding to the main peak 2.04 of the launched n ∥ spectrum. n ∥ deduced by the least-squares linear fit method remains near this value in the low density plasma with a high spatial correlation magnitude of 0.9. With an eight-channel probe system, a wave-number spectrum has also been deduced, which has a peak near to the measured dominant n ∥ .

47 OTHER INSTRUMENTATION↗

ArCS: A Magnetized LArTPC in a Test Beam

Over the past few decades, Liquid Argon Time Projection Chambers (LArTPCs) have emerged as a central technology for rare-event detection, due to their calorimetric and imaging capabilities. Adding a magnetic field to LArTPCs would enable charge identification and momentum measurements via curvature. For neutrino experiments, this is crucial for wrong-sign neutrino rejection, electron/positron and electron/photon discrimination, and improved momentum reconstruction. The ArCS (Argon detector with Charge Separation) experiment at Fermilab's Test Beam Facility will place a 47 40 90 cm LArTPC inside a 0.7 T magnet to: (i) establish charge sign discrimination for electrons and positrons, (ii) reconstruct particle momenta via curvature, and (iii) determine the minimal magnetic field needed for these measurements. This poster will present the project status, with updates on installation and simulations of expected performance.

Cicogna, Giulia [Bologna U.]↗

AUP first Pre-Series Cold Mass Installation into the Cryostat

For the HiLumi LHC Upgrade (HL-LHC), new high field and large-aperture quadrupole magnets for the low-beta inner triplets (Q1, Q2, Q3) are being built. These new quadrupole magnets are based on Nb3Sn superconducting technology. As part of the US-HiLumi Accelerator Upgrade Project (AUP), ten Cryostat Assemblies (LQXFA) for Q1 and Q3 replacement will be built, tested, and delivered to CERN. The first LQXFA was assembled and tested at Fermi National Accelerator Laboratory (FNAL) during fall 2022 and spring/summer 2023, respectively. This paper summarizes the assembly process and experience of the first LQXFA Cryostat Assembly at FNAL.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Field Harmonic Measurement of High-Gradient Permanent Magnet Quadrupoles for NSLS- II Upgrade

The National Synchrotron Light Source II (NSLS-II) is preparing for a major upgrade based on a new lattice concept, known as “Complex Bend,” to replace its existing double bend achromat (DBA) lattice. Here, this novel lattice will use high-gradient permanent magnet quadrupoles (PMQs) with small apertures in the range of 16–22 mm. A prototype complex bend branch with PMQs has been installed in the NSLS-II linac to evaluate the lattice's performance. An accurate and precise magnetic measurement system is required for field harmonic characterization and magnetic tuning of these PMQs. As part of this project a Rotating-Coil bench, based on a Printed Circuit Board (PCB) coil with a 12 mm diameter, has been configured to measure nine PMQs with bore diameter of 12.7 mm. This PCB coil has an active length of 270 mm, and is able to measure fields up to the 15th harmonic of the main field at a reference radius of 5 mm, while maintaining field quality levels within 10 ppm of the main field. This article presents the PCB coil setup, the harmonic measurement results and their temperature dependencies and repeatability. Simulation results on compensation of undesired multipoles using “IDBuilder”, a genetic algorithm-based optimizer code for magnetic tuning is included for field harmonic corrections.

36 MATERIALS SCIENCE↗

The motional Stark effect diagnostic for ITER

An overview of the plans for the motional Stark effect (MSE) diagnostic installation on the International Thermonuclear Experimental Reactor (ITER) is presented. The MSE diagnostic uniquely provides spatially localized magnetic field measurements inside the plasma. These are used to constrain equilibrium reconstructions to determine q(r), the safety factor as a function of minor radius. Meeting the system requirements to deliver q-profiles and related quantities with the specified radial resolution of 20 points over the minor radius, 10 ms time resolution, and better than 10% accuracy is challenging. MSE systems observe the D/H-α emission near 656.3 nm from neutral beams. As the beam atoms traverse the magnetic field, B⃗, at high velocity, v⃗, they experience a Lorentz electric field, v⃗×B⃗, which causes the spectral emission to be split and polarized due to the Stark effect. Traditional MSE-LP (line polarization) measurements determine the direction of the magnetic field in the observation volume using polarimetric analysis of the detected light. The harsh conditions of ITER are expected to deposit thin films of contaminants on the first mirror, which would alter the polarization state of reflected light significantly. On ITER, the combination of high magnetic field strength and high energy beams makes the Stark spectrum resolution suitable for the determination of the magnetic field magnitude from the line shift, so this approach has been selected. Every aspect of the measurement system must be planned for the burning plasma environment and carefully analyzed ahead of time. Current status and plans for the system are presented.

Instruments & Instrumentation↗

Plasma Guns for Magnetized Fuel Targets for PJMIF

In plasma jet driven magneto-inertial fusion (PJMIF) an array of discrete supersonic plasma jets is used to form a spherically imploding plasma liner, which then compresses a magnetized plasma target to fusion conditions. With funding from ARPA-E’s ALPHA program and from Strong Atomics LLC, HyperJet Fusion Corp and HyperV Technologies Corp. previously developed the plasma guns required for an experimental demonstration of the plasma liner formation part of the concept. A 36-gun demonstration of an imploding spherical plasma liner is currently underway on the PLX facility at Los Alamos National Laboratory. This present project addresses the next step required for a complete PJMIF concept, i.e. developing the magnetized plasma target. We proposed to form the target by stagnating a number of magnetized plasma jets in the center of the target chamber. This is accomplished by adding a bias field coil to the plasma liner gun to form a magnetized plasma jet. This experimental development took place at HyperJet in a geometry replicating the bias field environment that will be seen on a PLX port so the results are directly transferrable to the PLX experiment. The objective of this effort was the technical development and characterization of a new magnetized plasma jet using a high-performance, high momentum flux, contoured-gap coaxial plasma gun appropriate for use on the next stage of the PLX experiment. Electromagnetic modeling of the coil indicated the coil was best placed around the aluminum tubes of the gun transmission line, rather than around the chamber port as originally proposed. This maximized field strength in the breech and yielded much better flux linkage between gun electrodes. A 30-turn coil was ultimately implemented, allowing long pulses that could diffuse through the metal walls on the timescale of interest. \machtwo modeling predicted that less capacitance in the main PFN could potentially improve plasma jet velocities due to better matching of the current to the smaller plasma mass and the existing electrode contour designed to suppress blowby. This proved true, as testing showed markedly improved performance when the original 600uF bank was reduced to 400uF. A number of diagnostics were built and/or upgraded in order to characterize the plasma jets, inluding laser interferomtery for density, photodiodes for velocity, Bdot probes for magnetic field measurements, a Triple probe for temperature measurements, and spectroscopy for impurity content. A plasma gun with the 30-turn magnet coil installed, a 70% reduction in gas valve plenum volume, and a 33% reduction in main PFN capacitance produced a dense, high velocity, well magnetized plasma jet. We met or exceeded virtually all of the plasma jet parameter goals. Peak velocity of 135 km/s exceeded the 100 km/s goal by 35%, while the peak density of over 1.0x10 15 cm -3 was 3.3 times the goal of >3.0x10 14 cm -3 . Shot-to-shot repeatability is excellent, with a jitter of less than 300ns observed on the arrival fronts of the photodiode signals from one shot to the next. Average plasma jet lengths of 33cm (at 120km/s) were slightly longer than the 20cm goal, but jets as short as 11.8cm were observed at 135km/s. Mass is much higher than the targeted goal, averaging 106ug per shot compared to 20ug. The magnetic field is still a bit lower than desired, with a maximum to date of ~811G, compared to the goal of 1000G. Average values, though, were typically in the 300-450G range, when measured further downstream after some expected in flight decay. Temperature measurements are still a work in progress. Increasing the B field and completing temperature measurements will be continued on into the ongoing BETHE project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗