Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrument development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

HDG-1 Fiber Bragg grating data analysis

The main goal of the High dose graphite 1 Advanced test reactor experiment was to study nuclear grade graphite at high fluences. Additional supplementary optical fiber instrumentation was added to this long duration experiment for instrumentation development purposes. The supplementary instrumentation consisted of two pure silica core, fluorine doped cladding optical fibers each etched with 9 fiber Bragg gratings, one fiber being heat treated for 9 hours at 750 C and 16 hours at 750 C, the other being heat treated for 24 hours at 550 C and 48 hours at 650 C. Fiber Bragg gratings are known to have issues of measurement drift when in high temperature and high radiation environments like what is encountered in the Advanced test reactor. At the culmination of this experiment, the optical fibers saw ~1.3E21 n/cm2 total fluence, which is at the highest fluences that fiber Bragg gratings have been studied to date. Reported here is the analysis of this data including radiation induced shift and changes in sensitivity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Development of Mockups and Instrumentation for Spent Fuel Drying Tests

The purpose of this report is to provide updates on the experimental components, methodology, and instrumentation under development for use in advanced studies of realistic drying operations conducted on surrogate spent nuclear fuel. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system. Water remaining in canisters upon completion of drying procedures can lead to cladding corrosion, embrittlement, and breaching, as well as fuel degradation. Additional information is needed on the drying process efficacy to help evaluate the potential impacts of water retention on extended longterm dry storage. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates additional, well-designed investigations. Smaller-scale tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report describes the implementation of moisture monitoring equipment on a pressurized, submersible system employing a single waterproof, electrically heated spent fuel rod simulator as a demonstration of analytical capabilities during a drying process. A mass spectrometer with specially designed inlets was used to monitor moisture and other gases at 150 kPa to 800 kPa for a test simulating a forced helium dehydration procedure and below 1 torr for tests mimicking a vacuum drying process. The dew point data from the mass spectrometer was found to be in good agreement with a solid-state moisture probe. A distinct advantage of the mass spectrometer system was the capability to directly sample from the hightemperature (>200 °C) head space expected in a prototypic scale experiment where a solid-state moisture probe would suffer considerable loss of accuracy or fail altogether. The operational and analytical experiences gained from this test series are poised to support an expansion to assembly-scale tests at prototypic length. These assemblies are designed to feature prototypic assembly hardware, advanced diagnostics for in situ internal rod pressure monitoring, and failed fuel rod simulators with engineered cladding defects to challenge the drying system with waterlogged fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recent Developments in Hydrogeologic Applications for Strain Tensor Analyses

Changes in fluid pressure deform porous media and this effect occurs in a variety of hydrogeologic processes, from the change in storage during pumping or injection to fluctuations in water levels caused by barometric pressure. We have developed instruments for measuring small strains in porous media, and we have used the resulting strain data to evaluate well testing, hydraulic fracturing, manual loading at the ground surface, and ambient hydrologic processes, like rainfall and evaporation. A particularly important application is the use of strain tensor data measured at shallow depths to analyze well tests or hydraulic fractures conducted at much greater depths. An early demonstration of this technique was conducted at the North Avant Field north of Tulsa, Oklahoma, where Pennsylvanian sandstone creates a confined aquifer and oil reservoir at a depth of 530m. We have showed that the strains caused by injecting into the aquifer could be measured at a depth of 30m and used to evaluate the properties of the aquifer. We recently expanded the array of strainmeters at the North Avant Field by deploying three more instruments at shallow depth (30m) along with a deep instrument at 520m depth in the winter, 2021. The deep instrument is deployed in shale caprock slightly above the aquifer. To our knowledge, the deep strainmeter at the North Avant Field is the deepest strainmeter ever deployed and this required refining methods originally developed for shallow deployments. The instrument was lowered to depth on oil field tubing and cemented in place using techniques and materials developed for use in oil wells. Optical fiber used to communicate with the instrument was cemented in the annulus on the outside of tubing. This is significant because the techniques we used could readily be extended to greater depth, suggesting that strainmeters can be deployed over a wide range of depths for monitoring critical subsurface processes. For example, it suggests that strainmeters could be deployed through the caprock to monitor for leaks from underlying CO2 storage reservoirs. The strainmeter array at the North Avant Field has been used to characterize deformation during a series of injection tests in the spring and summer, 2021. All the new strainmeters respond to pumping, and the strainmeters we installed earlier also responded. To our knowledge, this is the first application of well testing in a deep aquifer that was monitored by an array of strainmeters—our earlier work used strainmeters at a single location. We are currently analyzing the strain data using an analytical solution, a proxy-based Bayesian inversion algorithm, and other methods. Strainmeter data has also been used to characterize periodic pumping tests by us and Riley Blais. A periodically varying pumping rate causes both hydraulic head and strain signals that vary with the same period as the pumping. The peaks and troughs of the head in monitoring wells lag behind the peaks and troughs of the head in the pumping well, and this lag time increases with distance from the pumping well. The lag time of the pressure and the distance to the monitoring well can be used in a simple analysis to estimate the hydraulic diffusivity of the aquifer. The lag time determined from strain data can be used to estimate aquifer properties using the same analysis that works for the pressure only for strain data measured at particular locations. That is because the strain field in a confining unit advances upward, laterally and then downward even though the pressure in the underlying aquifer only advances laterally, according to our recent simulations. We have field data showing that a small periodic signal superimposed on an injection rate at the North Avant Field will create a periodic strain signal at shallow strainmeters. The field data and the recent simulations suggest that including a periodic component to injection or pumping and then monitoring the resulting strain signal could be a way to monitor the subsurface.

Murdoch, Larry↗

Recent Developments in Hydrogeologic Applications for Strain Tensor Analyses

Changes in fluid pressure deform porous media and this effect occurs in a variety of hydrogeologic processes, from the change in storage during pumping or injection to fluctuations in water levels caused by barometric pressure. We have developed instruments for measuring small strains in porous media, and we have used the resulting strain data to evaluate well testing, hydraulic fracturing, manual loading at the ground surface, and ambient hydrologic processes, like rainfall and evaporation. A particularly important application is the use of strain tensor data measured at shallow depths to analyze well tests or hydraulic fractures conducted at much greater depths. An early demonstration of this technique was conducted at the North Avant Field north of Tulsa, Oklahoma, where Pennsylvanian sandstone creates a confined aquifer and oil reservoir at a depth of 530m. We have showed that the strains caused by injecting into the aquifer could be measured at a depth of 30m and used to evaluate the properties of the aquifer. We recently expanded the array of strainmeters at the North Avant Field by deploying three more instruments at shallow depth (30m) along with a deep instrument at 520m depth in the winter, 2021. The deep instrument is deployed in shale caprock slightly above the aquifer. To our knowledge, the deep strainmeter at the North Avant Field is the deepest strainmeter ever deployed and this required refining methods originally developed for shallow deployments. The instrument was lowered to depth on oil field tubing and cemented in place using techniques and materials developed for use in oil wells. Optical fiber used to communicate with the instrument was cemented in the annulus on the outside of tubing. This is significant because the techniques we used could readily be extended to greater depth, suggesting that strainmeters can be deployed over a wide range of depths for monitoring critical subsurface processes. For example, it suggests that strainmeters could be deployed through the caprock to monitor for leaks from underlying CO2 storage reservoirs. The strainmeter array at the North Avant Field has been used to characterize deformation during a series of injection tests in the spring and summer, 2021. All the new strainmeters respond to pumping, and the strainmeters we installed earlier also responded. To our knowledge, this is the first application of well testing in a deep aquifer that was monitored by an array of strainmeters—our earlier work used strainmeters at a single location. We are currently analyzing the strain data using an analytical solution, a proxy-based Bayesian inversion algorithm, and other methods. Strainmeter data has also been used to characterize periodic pumping tests by us and Riley Blais. A periodically varying pumping rate causes both hydraulic head and strain signals that vary with the same period as the pumping. The peaks and troughs of the head in monitoring wells lag behind the peaks and troughs of the head in the pumping well, and this lag time increases with distance from the pumping well. The lag time of the pressure and the distance to the monitoring well can be used in a simple analysis to estimate the hydraulic diffusivity of the aquifer. The lag time determined from strain data can be used to estimate aquifer properties using the same analysis that works for the pressure only for strain data measured at particular locations. That is because the strain field in a confining unit advances upward, laterally and then downward even though the pressure in the underlying aquifer only advances laterally, according to our recent simulations. We have field data showing that a small periodic signal superimposed on an injection rate at the North Avant Field will create a periodic strain signal at shallow strainmeters. The field data and the recent simulations suggest that including a periodic component to injection or pumping and then monitoring the resulting strain signal could be a way to monitor the subsurface.

Murdoch, Larry↗

Probing Phase Transitions and Magnetism in Minerals with Neutrons

We report the development of sophisticated sample environments to control temperature, pressure, and magnetic field has grown in parallel with neutron source and instrumentation development. High-pressure apparatus, with high- and low-temperature capability, novel designs for diamond cells, and large volume presses are matched with next-generation neutron sources and moderator designs to provide unprecedented neutron beam brightness. Recent developments in sample environments are expanding the pressure–temperature space accessible to neutron scattering experiments. Researchers are using new capabilities and an increased understanding of the fundamentals of structural and magnetic transitions to explore new territories, including hydrogenous minerals (e.g., ices and hydrates) and magnetic structural phase diagrams.

58 GEOSCIENCES↗

Developing High-Flux Ion Soft Landing with Mass-Selection for Improved Cryo-Electron Microscopy

The goal of this project is to redesign and repurpose existing high-flux ion soft-landing (SL) instrumentation developed at PNNL for new structural biology applications by integrating SL, mass-selection/separation of high mass-to-charge species, native mass spectrometry (MS), and cryo-electron microscopy (EM) to generate a workflow enabling structural and functional annotation of proteins and other complex biological samples. Ultimately, this work will result in a new instrument for mass-selection and SL based cryo-EM sample preparation and potentially increase the impact of PNNL and the broader microscopy community through commercial licensing.

47 OTHER INSTRUMENTATION↗

Artificial Intelligence and Machine Learning for Bioenergy Research: Opportunities and Challenges

The integration of artificial intelligence and machine learning (AI/ML) with automated experimentation, genomics, biosystems design, and bioprocessing technologies is poised to revolutionize scientific investigation and, particularly, bioenergy research. To identify the opportunities and challenges in this emerging research area, the U.S. Department of Energy’s (DOE) Biological and Environmental Research program (BER) and Bioenergy Technologies Office (BETO) held a joint virtual workshop on AI/ML for Bioenergy Research (AMBER) on August 23–25, 2022. These interests have since been amplified in a September 2022 Executive Order, “Advancing Biotechnology and Biomanufacturing Innovation for a Sustainable, Safe, and Secure U.S. Bioeconomy,” to promote a whole-of government approach to biotechnology development (White House 2022). Approximately 50 scientists with various backgrounds and expertise from academia, industry, and DOE national laboratories met to discuss the opportunities and challenges of AI/ML for bioenergy research. Workshop participants were tasked with assessing the potential for AI/ML and laboratory automation to advance biological understanding and engineering in general. They particularly examined how integrating AI/ML tools with laboratory automation could accelerate biosystems design and optimize biomanufacturing. Discussions included the data and computational infrastructure needed to augment biosystems design applications and the expertise and workforce development efforts urgently required to shift integrated systems toward bioenergy research more broadly. Participants discussed many existing and future applications of AI/ML for biosystems design ranging from enzymes to plants and microbes, microbiomes, and bioprocess development. They also identified three key categories of scientific and technical opportunities and challenges: high-quality data, AI/ML algorithms, and laboratory automation. Several main takeaways emerged from the workshop: 1. Numerous AI/ML and automated experimentation applications exist for a variety of DOE mission needs in energy and the environment; 2. Exemplary research grand challenges for which AI/ML could provide solutions include: building microbes and microbial communities to specifications, developing closed-loop autonomous design and control for biosystems design, and advancing scale-up and automation; 3. Lack of sufficient high-quality, annotated data hinders the development of AI/ML applications; 4. New and improved AI/ML tools are needed, particularly those meeting the specific needs of the BER and BETO research communities; 5. Trade-offs in performance, cost, and reliability exist between deploying commercially available versus building custom-developed instrumentation and software for automated or autonomous experimentation; translation of manual to automated or autonomous methods is often a nontrivial endeavor; 6. Training a new generation of young scientists who can develop and apply AI/ML tools is needed to solve long-standing scientific challenges in bioenergy research. The integration of AI/ML tools and automated experimentation represents a new data-driven research paradigm complementary to the traditional hypothesis-driven research paradigm. This paradigm accelerates design and optimization of biological systems and processes for a variety of DOE mission needs in energy and the environment. The AMBER workshop broadly explored the potential of this new paradigm for bioenergy research, of particular interest to BER and BETO, and identified key challenges and opportunities that DOE can address in the coming years by leveraging its unique capabilities and resources.

59 BASIC BIOLOGICAL SCIENCES↗

Blue Canyon Dome: Development of a Small-Scale Testbed for Monitoring Underground Explosions

This report documents the development of the Blue Canyon Dome (BCD) testbed, including test site selection, development, instrumentation, and logistical considerations. The BCD testbed was designed for small-scale explosive tests (~5 kg TNT equivalence maximum) for the purpose of comparing diagnostic signals from different types of explosives, the assumption being that different chemical explosives would generate different signatures on geophysical and other monitoring tools. The BCD testbed is located at the Energetic Materials Research and Testing Center near Socorro, New Mexico. Instrumentation includes an electrical resistivity tomography array, geophones, distributed acoustic sensing, gas samplers, distributed temperature sensing, pressure transducers, and high-speed cameras. This SAND report is a reference for BCD testbed development that can be cited in future publications.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Radiation hard Ga 2 O 3 detectors for high energy physics

In this project, we explore the use of ultra-wide bandgap Ga 2 O 3 materials for fabricating next-generation radiation hard solid-state detectors for high energy physics (HEP) applications. As an emerging semiconductor, Ga 2 O 3 has ultra-wide bandgap (4.5-4.9 eV), high breakdown electric field (8 MV/cm) and much lower production cost compared with radiation hard diamond detectors, all of which make Ga 2 O 3 a great candidate material working in harsh radiation environment of future HEP experiments. The recent breakthrough of growth technologies of Ga 2 O 3 significantly improves the availability of large area single crystalline Ga 2 O 3 . We focus on an early proof-of-principle demonstration of Ga 2 O 3 detectors and conduct comprehensive material and detector characterization to evaluate the potential of the emerging Ga 2 O 3 as a new radiation-hard detector material. Our endeavors directly support the instrumentation development and update need of HEP experiments and fits very well into the DOE HEP “Detector R&D” research subprogram.

36 MATERIALS SCIENCE↗

Development of Large-Volume-Diamond Anvil Cell for Neutron Diffraction: The Neutron Diamond Anvil Cell Project at ORNL

10 years ago, Dave Mao, director of EFree (energy frontier research in extreme environments), a DOE energy frontier recognized the importance of neutron science for energy research. The subsequent establishment of a neutron group within EFree lead to the establishment of an “Instrument Development Team” for SNAP, the High-Pressure beamline at the Spallation Neutron Source at Oak Ridge National Laboratory in Tennessee. The idea was to develop novel high pressure techniques to expand the pressure range for neutron diffraction. A goal was set to reach half megabar levels (50 GPa), which at the time was considered as extremely challenging. Here we will give a brief overview of the developments during the last decade in this novel area of research. Fortunately, during this period multi carat diamond anvils have become available mainly by the chemical vapor deposition process (CVD), making research in this pressure range and beyond rather routine. This paper shows the latest developments in large anvil designs, compact multiple ton diamond cells and some examples of high-quality neutron diffraction patterns of sample sizes far below conventional levels.

Boehler, Reinhard↗

Using Best Basis Inventory Data to Direct Strategies for Real Time Monitoring of Hanford High Level Waste – 26226

The potential to accelerate the processing of low- and high-level tank waste by applying real-time monitoring (RTM) of chemical and physical properties has prompted research into the suitability of multiple analytical methods for that purpose. The broad variety of waste stream properties and the large number of analytes of interest (as evidenced by Waste Acceptance Criteria (WAC) and Process Control Limit (PCL) lists) lead to an overwhelming set of possible analytical scenarios. This report describes the use of Best Basis Inventory (BBI) data to find the most relevant analytical targets for the specific case of monitoring the blending of High Level Waste from multiple tanks prior to introduction into a vitrification facility. Campaigns for blending this waste to minimize the risk of exceeding WACs and PCLs have been proposed. However, the predicted compositions of the blended materials do not incorporate any uncertainties that may be associated with the representativeness of the waste layer samples or the laboratory analyses that generated the BBI data. Also, they do not include any uncertainty associated with the precision of collecting highly specific fractions of the layers during a blending campaign or any inhomogeneities that may exist in those layers. Monte Carlo methods are used to apply uncertainties to the compositions of the individual layers specified in the campaign recipes. The resulting variations in the compositions of the blended materials allow estimation of the risks of exceeding WACs and PCLs for each campaign. A critical subset of WACs/PCLs – NOx, NaK, AlFeZr, and S – are especially at risk of being exceeded in multiple campaigns. These analytes should be the focus of instrument development. We also have extracted the expected solid/supernate distribution for these analytes, which establishes important performance criteria for individual analytical methods. The BBI data also permits an understanding of the different chemical forms in which the analytes appear. Thus, the need to establish instrumental sensitivity to these forms can be gainfully addressed. Although concentrating on one specific application – the blending of tank waste - this approach should be generalizable for the analysis of other possible RTM applications for waste processing.

Lascola, Robert [Savannah River National Laborator↗

Development of deflector mode for spin-resolved time-of-flight photoemission spectroscopy

Spin- and angle-resolved photoemission spectroscopy (“spin-ARPES”) is a powerful technique for probing the spin degree-of-freedom in materials with nontrivial topology, magnetism, and strong correlations. Spin-ARPES faces severe experimental challenges compared to conventional ARPES attributed to the dramatically lower efficiency of its detection mechanism, making it crucial for instrumentation developments that improve the overall performance of the technique. Here in this paper, we demonstrate the functionality of our spin-ARPES setup based on time-of-flight spectroscopy and introduce our recent development of an electrostatic deflector mode to map out spin-resolved band structures without sample rotation. We demonstrate the functionality by presenting the spin-resolved spectra of the topological insulator Bi2Te3 and describe in detail the spectrum calibrations based on numerical simulations. By implementing the deflector mode, we minimize the need for sample rotation during measurements, hence improving the overall efficiency of experiments on small or inhomogeneous samples.

47 OTHER INSTRUMENTATION↗

Hyperspectral x-ray imaging mapping capabilities for nuclear forensics

Nuclear forensics relies on the integration of complementary signatures to constrain the origins and history of materials. Outcomes benefit from the timeliness and precision of the disparate methods that form typical analysis chains. Sample forms are often either minute in quantity or contain signatures like morphology or composition heterogeneity encoded on a microscale, so many analysis techniques focus on resolving signatures on ever-smaller length scales. The new hyperspectral x-ray imaging (HXI) instrument developed at Los Alamos National Laboratory seeks to improve the information available from scanning electron microscopy (SEM) x-ray spectrum analysis through superior spectral energy resolution vs. typical energy dispersive spectroscopy (EDS) systems in common use in nuclear forensics and other microanalysis fields. Based on arrays of transition-edge sensor (TES) microcalorimeter detectors, this instrument achieves a typical energy resolution of 7 eV full-width at half-maximum (FWHM) at 2 keV, opening new possibilities in trace element detection/analysis and chemical state determination through spectral shape shifts. We present here some of the first applications of the HXI instrument to actinide samples and discuss potential maturation of this nascent technology for future analysis pipelines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An improved Method for Determining Transient Fuel Dilution of Oil in an Internal-Combustion Engine Using Laser-Induced Florescence and Multivariate Least Square Calibration

An optical diagnostic, based on laser-induced fluorescence (LIF), has been developed for on-engine measurements of real-time fuel dilution of engine oil or fuel in oil (FIO). Fuel dilution of oil is broadly relevant to advancing engine technology including durability, calibration, and catalyst-system management, and believed to promote destructive stochastic pre-ignition (SPI) during high-load engine operations. While standard (e.g., ASTM D3524-90) methods are not capable of real-time transient measurements, the LIF technique resolves transient dilution on the minutes time scale. We have expanded on our original FIO instrument development by introducing an improved analysis based on multivariate least square chemometrics analysis. The measurement uses a fuel dye (180–1300 parts per million, by mass) and monitors for its presence in the oil using 532 nm excitation and LIF. While the original FIO instrument utilized a two-color ratio method for analysis, the improved chemometric analysis uses the fully resolved LIF dye spectra to provide better predictive FIO accuracy (>92%) over a wide FIO range (1.5–14%) typical of engine application. We also investigate the effect of oil temperature on the LIF signal. Limited engine applications for demonstrating and validating the improved FIO instrument are shown, and the related data used to quantify practical detection limit and sensitivity. The improved analysis is insensitive to laser power fluctuation and change in detector integration time, providing an excellent FIO sensitivity (1–2%) and detection limit (0.01 %FIO) over a wide range of loads and injection timings, illustrating this updated approach to be a promising tool for advancing engine technology.

42 ENGINEERING↗

3D, Real-time Label-free Visualization of Cellular Health

This work directly addresses a key question raised in TA7, Topic L1 of HDTRA1-16-24-FRCWMDCall, “Can quantum level changes be detected, mapped, and understood in the biological environment to allow faster diagnostic responses?” This work will use the inherently sensitive quantum property of a molecular excited state lifetime to visualize and map discrete, subtle nanometer-scale changes (e.g. NADPH vs NADH) that are key indicators of cellular health in response to chemical and biological threats and MCMs. It will also develop and exploit new, fast imaging light-sheet methods to allow faster diagnostic responses. This new imaging system will exploit time-correlated single photon counting and new advances in single-objective light-sheet microscopy (oblique plane microscopy) for fast, quantitative analysis of cellular redox state. We will add an entirely new dimension (excited state fluorescence lifetime) to oblique plane microscopy—a method that even without this added dimension was labeled by Nature Methods in 2021 as a ‘Method to Watch.’ Following instrument development and validation, we will explore cellular response to Burkholderia infections and antibiotic treatment in immortal cell lines followed by expansion to more realistic cellular environments (such as neuro-muscular junctions, NMJs) to test nerve agent simulants and their MCMs. As a microscopy platform, these methods hold the promise of being able to visualize a single infected cell (or a cellular compartment) and MCM treatment well before a larger and later organ/organism response.

47 OTHER INSTRUMENTATION↗

Low Repetition-Rate, High-Resolution Femtosecond Transmission Electron Microscopy

Spatial and energy resolutions of state-of-the-art transmission electron microscopes (TEMs) have surpassed 50 pm and 5 meV. However, with respect to the time domain, even the fastest detectors combined with the brightest sources may only be able to reach the microsecond timescale. Thus, conventional methods are incapable of resolving myriad fundamental ultrafast (i.e., attosecond to picosecond) atomic-scale dynamics. The successful demonstration of femtosecond (fs) laser-based (LB) ultrafast transmission electron microscopy (UEM) nearly 20 years ago provided a means to span this nearly 10-order-of-magnitude temporal gap. While nanometer-picosecond UEM studies of dynamics are now well established, ultrafast Å-scale imaging has gone largely unrealized. Further, while instrument development has rightly been an emphasis, and while new modalities and uses of pulsed-beam TEM continue to emerge, the overall chemical and materials application space has been only modestly explored to date. In this Perspectives article, we argue that these apparent shortfalls can be attributed to a simple lack of data and detail. We speculate that present work and continued growth of the field will ultimately lead to the realization that Å-scale fs dynamics can indeed be imaged with minimally modified UEM instrumentation and with repetition rates (f rep ) below - and perhaps even well below - 1 MHz. We further argue that use of low f rep , whether for LB UEM or for chopped/bunched beams, significantly expands the accessible application space. Furthermore, this calls for systematically establishing modality-specific limits so that especially promising technologies can be pursued, thus ultimately facilitating broader adoption as individual instrument capabilities expand.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗