Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals

Small animal SPECT imaging systems have multiple potential applications in biomedical research. Whereas SPECT data are commonly interpreted qualitatively in a clinical setting, the ability to accurately quantify measurements will increase the utility of the SPECT data for laboratory measurements involving small animals. In this work, we assess the effect of photon attenuation, scatter and partial volume errors on the quantitative accuracy of small animal SPECT measurements, first with Monte Carlo simulation and then confirmed with experimental measurements. The simulations modeled the imaging geometry of a commercially available small animal SPECT system. We simulated the imaging of a radioactive source within a cylinder of water, and reconstructed the projection data using iterative reconstruction algorithms. The size of the source and the size of the surrounding cylinder were varied to evaluate the effects of photon attenuation and scatter on quantitative accuracy. We found that photon attenuation can reduce the measured concentration of radioactivity in a volume of interest in the center of a rat-sized cylinder of water by up to 50percent when imaging with iodine-125, and up to 25percent when imaging with technetium-99m. When imaging with iodine-125, the scatter-to-primary ratio can reach up to approximately 30percent, and can cause overestimation of the radioactivity concentration when reconstructing data with attenuation correction. We varied the size of the source to evaluate partial volume errors, which we found to be a strong function of the size of the volume of interest and the spatial resolution. These errors can result in large (>50percent) changes in the measured amount of radioactivity. The simulation results were compared with and found to agree with experimental measurements. The inclusion of attenuation correction in the reconstruction algorithm improved quantitative accuracy. We also found that an improvement of the spatial resolution through the use of resolution recovery techniques (i.e. modeling the finite collimator spatial resolution in iterative reconstruction algorithms) can significantly reduce the partial volume errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-D-18A-04: How Iterative Reconstruction Algorithms Affect the MTFs of Variable-Contrast Targets in CT Images

Purpose: To determine how filtered back-projection (FBP), adaptive statistical (ASiR), and model based (MBIR) iterative reconstruction algorithms affect the measured modulation transfer functions (MTFs) of variable-contrast targets over a wide range of clinically applicable dose levels. Methods: The Catphan 600 CTP401 module, surrounded by an oval, fat-equivalent ring to mimic patient size/shape, was scanned on a GE HD750 CT scanner at 1, 2, 3, 6, 12 and 24 mGy CTDIvol levels with typical patient scan parameters: 120kVp, 0.8s, 40mm beam width, large SFOV, 2.5mm thickness, 0.984 pitch. The images were reconstructed using GE's Standard kernel with FBP; 20%, 40% and 70% ASiR; and MBIR. A task-based MTF (MTFtask) was computed for six cylindrical targets: 2 low-contrast (Polystyrene, LDPE), 2 medium-contrast (Delrin, PMP), and 2 high-contrast (Teflon, air). MTFtask was used to compare the performance of reconstruction algorithms with decreasing CTDIvol from 24mGy, which is currently used in the clinic. Results: For the air target and 75% dose savings (6 mGy), MBIR MTFtask at 5 lp/cm measured 0.24, compared to 0.20 for 70% ASiR and 0.11 for FBP. Overall, for both high-contrast targets, MBIR MTFtask improved with increasing CTDIvol and consistently outperformed ASiR and FBP near the system's Nyquist frequency. Conversely, for Polystyrene at 6 mGy, MBIR (0.10) and 70% ASiR (0.07) MTFtask was lower than for FBP (0.18). For medium and low-contrast targets, FBP remains the best overall algorithm for improved resolution at low CTDIvol (1–6 mGy) levels, whereas MBIR is comparable at higher dose levels (12–24 mGy). Conclusion: MBIR improved the MTF of small, high-contrast targets compared to FBP and ASiR at doses of 50%–12.5% of those currently used in the clinic. However, for imaging low- and mediumcontrast targets, FBP performed the best across all dose levels. For assessing MTF from different reconstruction algorithms, task-based MTF measurements are necessary.

60 APPLIED LIFE SCIENCES↗

CRADA: Data Acquisition and Tomographic Software Development

Dr. Raymond R. Raylman, Professor and Vice Chair for Research, Radiology Department at WVU was the Principal Investigator for the project. The Jefferson Lab partner on this project was the Radiation Detector and Imaging Group in the Physics Division, led by Dr. Drew Weisenberger who was the coordinator of the project execution and the chief contact with WVU. The responsibility of Jefferson Lab was to facilitate optimization of data acquisition software, conversion of JLab Fortran iterative positron emission mammography computer code to C++ and to act as a computer code repository. During the two year project interactions and exchange of information was directed by Dr. Raylman and Dr. Wesienberger. WVU provided the expertise that allowed JLab to continue development of the current JLab data acquisition software referred to as JDAQ. JDAQ is a highly flexible Java language based data acquisition tool that helps to minimize software induced dead-time while maintaining the highest possible data rates from a JLab built FPGA based analog-to-digital convertor (ADC). JDAQ interfaces directly with the FPGA based multi-channel ADCs. Using JDAQ it is possible process data from a number of different detector types such as the PET systems at WVU. Because of the inherent flexibility of our processing software, we are also able adjust detector readout parameters during operation to provide the best possible data presentation and calibration parameters. To accommodate the high rate nature of PET detector systems JDAQ was designed to be scalable across an Ethernet network as well as for multi-cpu computer systems, and it also has the capability to synchronize many ADCs connected to multiple computers. During the project WVU will provided iterative reconstruction algorithm expertise and Fortran programming assistance to facilitate the conversion to C++ of a JLab developed Fortran positron emission mammography (PEM) reconstruction code. Also WVU provided acceptance testing of the new C++ based PEM reconstruction code. The PEM code is a maximization (MLEM) image reconstruction program that created images from the list-mode data acquired from the PET system.

97 MATHEMATICS AND COMPUTING↗

GENFIRE: A generalized Fourier iterative reconstruction algorithm for high-resolution 3D imaging

Tomography has made a radical impact on diverse fields ranging from the study of 3D atomic arrangements in matter to the study of human health in medicine. Despite its very diverse applications, the core of tomography remains the same, that is, a mathematical method must be implemented to reconstruct the 3D structure of an object from a number of 2D projections. Here, we present the mathematical implementation of a tomographic algorithm, termed GENeralized Fourier Iterative REconstruction (GENFIRE), for high-resolution 3D reconstruction from a limited number of 2D projections. GENFIRE first assembles a 3D Fourier grid with oversampling and then iterates between real and reciprocal space to search for a global solution that is concurrently consistent with the measured data and general physical constraints. The algorithm requires minimal human intervention and also incorporates angular refinement to reduce the tilt angle error. We demonstrate that GENFIRE can produce superior results relative to several other popular tomographic reconstruction techniques through numerical simulations and by experimentally reconstructing the 3D structure of a porous material and a frozen-hydrated marine cyanobacterium. As a result, equipped with a graphical user interface, GENFIRE is freely available from our website and is expected to find broad applications across different disciplines.

36 MATERIALS SCIENCE↗

Downscaling SSP-consistent global spatial urban land projections from 1/8-degree to 1-km resolution 2000–2100

Abstract Long-term, spatial urban land projections that simultaneously offer global coverage and local-scale empirical accuracy are rare. Recently a set of such projections was produced using data-science-based simulations and the Shared Socioeconomic Pathways (SSPs). These projections update at decadal time intervals from 2000 to 2100 with a spatial resolution of 1/8 degree, while many socio-environmental studies customarily run their analysis and modelling at finer spatial resolutions, e.g. 1-km. Here we develop and validate an algorithm to downscale the 1/8-degree spatial urban land projections to the 1-km resolution. The algorithm uses an iterative process to allocate the decadal amount of urban land expansion originally projected for each 1/8-degree grid to its constituent 1-km grids. The results are a set of global maps showing urban land fractions at the 1-km resolution, updated at decadal intervals from 2000 to 2100, under five different urban land expansion scenarios consistent with the SSPs. The data can support studies of potential interactions between future urbanization and environmental changes across spatial and temporal scales.

97 MATHEMATICS AND COMPUTING↗

Fast compressed sensing-based CBCT reconstruction using Barzilai-Borwein formulation for application to on-line IGRT

Purpose: Compressed sensing theory has enabled an accurate, low-dose cone-beam computed tomography (CBCT) reconstruction using a minimal number of noisy projections. However, the reconstruction time remains a significant challenge for practical implementation in the clinic. In this work, we propose a novel gradient projection algorithm, based on the Gradient-Projection-Barzilai-Borwein formulation (GP-BB), that handles the total variation (TV)-norm regularization-based least squares problem for the CBCT reconstruction in a highly efficient manner, with speed acceptable for routine use in the clinic. Methods: CBCT is reconstructed by minimizing an energy function consisting of a data fidelity term and a TV-norm regularization term. Both terms are simultaneously minimized by calculating the gradient projection of the energy function with the step size determined using an approximate Hessian calculation at each iteration, based on the Barzilai-Borwein formulation. To speed up the process, a multiresolution optimization is used. In addition, the entire algorithm was designed to run with a single graphics processing unit (GPU) card. To evaluate the performance, the Shepp-Logan numerical phantom, the CatPhan 600 physical phantom, and a clinically-treated head-and-neck patient were acquired from the TrueBeam system (Varian Medical Systems, Palo Alto, CA). For each scan, in total, 364 projections were acquired in a 200 deg. rotation. The imager has 1024 x 768 pixels with 0.388 x 0.388-mm resolution. This was down-sampled to 512 x 384 pixels with 0.776 x 0.776-mm resolution for reconstruction. Evenly spaced angles were subsampled and used for varying the number of projections for the image reconstruction. To assess the performance of our GP-BB algorithm, we have implemented and compared with three compressed sensing-type algorithms, the two of which are popular and published (forward-backward splitting techniques), and the other one with a basic line-search technique. In addition, the conventional Feldkamp-Davis-Kress (FDK) reconstruction of the clinical patient data is compared as well. Results: In comparison with the other compressed sensing-type algorithms, our algorithm showed convergence in {<=}30 iterations whereas other published algorithms need at least 50 iterations in order to reconstruct the Shepp-Logan phantom image. With the CatPhan phantom, the GP-BB algorithm achieved a clinically-reasonable image with 40 projections in 12 iterations, in less than 12.6 s. This is at least an order of magnitude faster in reconstruction time compared with the most recent reports utilizing GPU technology given the same input projections. For the head-and-neck clinical scan, clinically-reasonable images were obtained from 120 projections in 34-78 s converging in 12-30 iterations. In this reconstruction range (i.e., 120 projections) the image quality is visually similar to or better than the conventional FDK reconstructed images using 364 projections. This represents a dose reduction of nearly 67% (120/364 projections) while maintaining a reasonable speed in clinical implementation. Conclusions: In this paper, we proposed a novel, fast, low-dose CBCT reconstruction algorithm using the Barzilai-Borwein step-size calculation. A clinically viable head-and-neck image can be obtained within {approx}34-78 s while simultaneously cutting the dose by approximately 67%. This makes our GP-BB algorithm potentially useful in an on-line image-guided radiation therapy (IGRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerated iterative beam angle selection in IMRT

Purpose: Iterative methods for beam angle selection (BAS) for intensity-modulated radiation therapy (IMRT) planning sequentially construct a beneficial ensemble of beam directions. In a naïve implementation, the nth beam is selected by adding beam orientations one-by-one from a discrete set of candidates to an existing ensemble of (n − 1) beams. The best beam orientation is identified in a time consuming process by solving the fluence map optimization (FMO) problem for every candidate beam and selecting the beam that yields the largest improvement to the objective function value. This paper evaluates two alternative methods to accelerate iterative BAS based on surrogates for the FMO objective function value. Methods: We suggest to select candidate beams not based on the FMO objective function value after convergence but (1) based on the objective function value after five FMO iterations of a gradient based algorithm and (2) based on a projected gradient of the FMO problem in the first iteration. The performance of the objective function surrogates is evaluated based on the resulting objective function values and dose statistics in a treatment planning study comprising three intracranial, three pancreas, and three prostate cases. Furthermore, iterative BAS is evaluated for an application in which a small number of noncoplanar beams complement a set of coplanar beam orientations. This scenario is of practical interest as noncoplanar setups may require additional attention of the treatment personnel for every couch rotation. Results: Iterative BAS relying on objective function surrogates yields similar results compared to naïve BAS with regard to the objective function values and dose statistics. At the same time, early stopping of the FMO and using the projected gradient during the first iteration enable reductions in computation time by approximately one to two orders of magnitude. With regard to the clinical delivery of noncoplanar IMRT treatments, we could show that optimized beam ensembles using only a few noncoplanar beam orientations often approach the plan quality of fully noncoplanar ensembles. Conclusions: We conclude that iterative BAS in combination with objective function surrogates can be a viable option to implement automated BAS at clinically acceptable computation times.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Acceptability of Iterative Reconstruction Algorithms in Head CT: An Assessment of Sinogram Affirmed Iterative Reconstruction (SAFIRE) vs. Filtered Back Projection (FBP) Using Phantoms

Computed tomography (CT) is the primary imaging investigation for many neurologic conditions with a proportion of patients incurring cumulative doses. Iterative reconstruction (IR) allows dose optimization, but head CT presents unique image quality complexities and may lead to strong reader preferences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final report for “Extreme-scale Algorithms and Solver Resilience”

This is a joint project with principal investigators at Oak Ridge National Laboratory, Sandia National Laboratories, the University of California at Berkeley, and the University of Tennessee. Our part of the project involves developing performance models for highly scalable algorithms and the development of latency tolerant iterative methods. During this project, we extended our performance models for the Multigrid method for solving large systems of linear equations and conducted experiments with highly scalable variants of conjugate gradient methods that avoid blocking synchronization. In addition, we worked with the other members of the project on alternative techniques for resilience and reproducibility. We also presented an alternative approach for reproducible dot-products in parallel computations that performs almost as well as the conventional approach by separating the order of computation from the details of the decomposition of vectors across the processes.

97 MATHEMATICS AND COMPUTING↗

An accelerated threshold-based back-projection algorithm for Compton camera image reconstruction

Purpose: Compton camera imaging (CCI) systems are currently under investigation for radiotherapy dose reconstruction and verification. The ability of such a system to provide real-time images during dose delivery will be limited by the computational speed of the image reconstruction algorithm. In this work, the authors present a fast and simple method by which to generate an initial back-projected image from acquired CCI data, suitable for use in a filtered back-projection algorithm or as a starting point for iterative reconstruction algorithms, and compare its performance to the current state of the art. Methods: Each detector event in a CCI system describes a conical surface that includes the true point of origin of the detected photon. Numerical image reconstruction algorithms require, as a first step, the back-projection of each of these conical surfaces into an image space. The algorithm presented here first generates a solution matrix for each slice of the image space by solving the intersection of the conical surface with the image plane. Each element of the solution matrix is proportional to the distance of the corresponding voxel from the true intersection curve. A threshold function was developed to extract those pixels sufficiently close to the true intersection to generate a binary intersection curve. This process is repeated for each image plane for each CCI detector event, resulting in a three-dimensional back-projection image. The performance of this algorithm was tested against a marching algorithm known for speed and accuracy. Results: The threshold-based algorithm was found to be approximately four times faster than the current state of the art with minimal deficit to image quality, arising from the fact that a generically applicable threshold function cannot provide perfect results in all situations. The algorithm fails to extract a complete intersection curve in image slices near the detector surface for detector event cones having axes nearly parallel to the image plane. This effect decreases the sum of the image, thereby also affecting the mean, standard deviation, and SNR of the image. All back-projected events associated with a simulated point source intersected the voxel containing the source and the FWHM of the back-projected image was similar to that obtained from the marching method. Conclusions: The slight deficit to image quality observed with the threshold-based back-projection algorithm described here is outweighed by the 75% reduction in computation time. The implementation of this method requires the development of an optimum threshold function, which determines the overall accuracy of the method. This makes the algorithm well-suited to applications involving the reconstruction of many large images, where the time invested in threshold development is offset by the decreased image reconstruction time. Implemented in a parallel-computing environment, the threshold-based algorithm has the potential to provide real-time dose verification for radiation therapy.

60 APPLIED LIFE SCIENCES↗

WE-EF-207-07: Dual Energy CT with One Full Scan and a Second Sparse-View Scan Using Structure Preserving Iterative Reconstruction (SPIR)

Purpose: Conventional dual energy CT (DECT) reconstructs CT and basis material images from two full-size projection datasets with different energy spectra. To relax the data requirement, we propose an iterative DECT reconstruction algorithm using one full scan and a second sparse-view scan by utilizing redundant structural information of the same object acquired at two different energies. Methods: We first reconstruct a full-scan CT image using filtered-backprojection (FBP) algorithm. The material similarities of each pixel with other pixels are calculated by an exponential function about pixel value differences. We assume that the material similarities of pixels remains in the second CT scan, although pixel values may vary. An iterative method is designed to reconstruct the second CT image from reduced projections. Under the data fidelity constraint, the algorithm minimizes the L2 norm of the difference between pixel value and its estimation, which is the average of other pixel values weighted by their similarities. The proposed algorithm, referred to as structure preserving iterative reconstruction (SPIR), is evaluated on physical phantoms. Results: On the Catphan600 phantom, SPIR-based DECT method with a second 10-view scan reduces the noise standard deviation of a full-scan FBP CT reconstruction by a factor of 4 with well-maintained spatial resolution, while iterative reconstruction using total-variation regularization (TVR) degrades the spatial resolution at the same noise level. The proposed method achieves less than 1% measurement difference on electron density map compared with the conventional two-full-scan DECT. On an anthropomorphic pediatric phantom, our method successfully reconstructs the complicated vertebra structures and decomposes bone and soft tissue. Conclusion: We develop an effective method to reduce the number of views and therefore data acquisition in DECT. We show that SPIR-based DECT using one full scan and a second 10-view scan can provide high-quality DECT images and accurate electron density maps as conventional two-full-scan DECT.

60 APPLIED LIFE SCIENCES↗

TU-F-18A-06: Dual Energy CT Using One Full Scan and a Second Scan with Very Few Projections

Purpose: The conventional dual energy CT (DECT) requires two full CT scans at different energy levels, resulting in dose increase as well as imaging errors from patient motion between the two scans. To shorten the scan time of DECT and thus overcome these drawbacks, we propose a new DECT algorithm using one full scan and a second scan with very few projections by preserving structural information. Methods: We first reconstruct a CT image on the full scan using a standard filtered-backprojection (FBP) algorithm. We then use a compressed sensing (CS) based iterative algorithm on the second scan for reconstruction from very few projections. The edges extracted from the first scan are used as weights in the Objectives: function of the CS-based reconstruction to substantially improve the image quality of CT reconstruction. The basis material images are then obtained by an iterative image-domain decomposition method and an electron density map is finally calculated. The proposed method is evaluated on phantoms. Results: On the Catphan 600 phantom, the CT reconstruction mean error using the proposed method on 20 and 5 projections are 4.76% and 5.02%, respectively. Compared with conventional iterative reconstruction, the proposed edge weighting preserves object structures and achieves a better spatial resolution. With basis materials of Iodine and Teflon, our method on 20 projections obtains similar quality of decomposed material images compared with FBP on a full scan and the mean error of electron density in the selected regions of interest is 0.29%. Conclusion: We propose an effective method for reducing projections and therefore scan time in DECT. We show that a full scan plus a 20-projection scan are sufficient to provide DECT images and electron density with similar quality compared with two full scans. Our future work includes more phantom studies to validate the performance of our method.

60 APPLIED LIFE SCIENCES↗

Simultaneous segmentation and reconstruction: A level set method approach for limited view computed tomography

Purpose: An iterative tomographic reconstruction algorithm that simultaneously segments and reconstructs the reconstruction domain is proposed and applied to tomographic reconstructions from a sparse number of projection images. Methods: The proposed algorithm uses a two-phase level set method segmentation in conjunction with an iterative tomographic reconstruction to achieve simultaneous segmentation and reconstruction. The simultaneous segmentation and reconstruction is achieved by alternating between level set function evolutions and per-region intensity value updates. To deal with the limited number of projections, a priori information about the reconstruction is enforced via penalized likelihood function. Specifically, smooth function within each region (piecewise smooth function) and bounded function intensity values for each region are assumed. Such a priori information is formulated into a quadratic objective function with linear bound constraints. The level set function evolutions are achieved by artificially time evolving the level set function in the negative gradient direction; the intensity value updates are achieved by using the gradient projection conjugate gradient algorithm. Results: The proposed simultaneous segmentation and reconstruction results were compared to ''conventional'' iterative reconstruction (with no segmentation), iterative reconstruction followed by segmentation, and filtered backprojection. Improvements of 6%-13% in the normalized root mean square error were observed when the proposed algorithm was applied to simulated projections of a numerical phantom and to real fan-beam projections of the Catphan phantom, both of which did not satisfy the a priori assumptions. Conclusions: The proposed simultaneous segmentation and reconstruction resulted in improved reconstruction image quality. The algorithm correctly segments the reconstruction space into regions, preserves sharp edges between different regions, and smoothes the noise within each region. The proposed algorithm framework has the flexibility to be adapted to different a priori constraints while maintaining the benefits achieved by the simultaneous segmentation and reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real space iterative reconstruction for vector tomography (RESIRE-V)

Tomography has had an important impact on the physical, biological, and medical sciences. To date, most tomographic applications have been focused on 3D scalar reconstructions. However, in some crucial applications, vector tomography is required to reconstruct 3D vector fields such as the electric and magnetic fields. Over the years, several vector tomography methods have been developed. Here, we present the mathematical foundation and algorithmic implementation of REal Space Iterative REconstruction for Vector tomography, termed RESIRE-V. RESIRE-V uses multiple tilt series of projections and iterates between the projections and a 3D reconstruction. Each iteration consists of a forward step using the Radon transform and a backward step using its transpose, then updates the object via gradient descent. Incorporating with a 3D support constraint, the algorithm iteratively minimizes an error metric, defined as the difference between the measured and calculated projections. The algorithm can also be used to refine the tilt angles and further improve the 3D reconstruction. To validate RESIRE-V, we first apply it to a simulated data set of the 3D magnetization vector field, consisting of two orthogonal tilt series, each with a missing wedge. Our quantitative analysis shows that the three components of the reconstructed magnetization vector field agree well with the ground-truth counterparts. We then use RESIRE-V to reconstruct the 3D magnetization vector field of a ferromagnetic meta-lattice consisting of three tilt series. Our 3D vector reconstruction reveals the existence of topological magnetic defects with positive and negative charges. We expect that RESIRE-V can be incorporated into different imaging modalities as a general vector tomography method. To make the algorithm accessible to a broad user community, we have made our RESIRE-V MATLAB source codes and the data freely available at https://github.com/minhpham0309/RESIRE-V.

47 OTHER INSTRUMENTATION↗

SU-E-T-33: A Feasibility-Seeking Algorithm Applied to Planning of Intensity Modulated Proton Therapy: A Proof of Principle Study

Purpose: To investigate the applicability of feasibility-seeking cyclic orthogonal projections to the field of intensity modulated proton therapy (IMPT) inverse planning. Feasibility of constraints only, as opposed to optimization of a merit function, is less demanding algorithmically and holds a promise of parallel computations capability with non-cyclic orthogonal projections algorithms such as string-averaging or block-iterative strategies. Methods: A virtual 2D geometry was designed containing a C-shaped planning target volume (PTV) surrounding an organ at risk (OAR). The geometry was pixelized into 1 mm pixels. Four beams containing a subset of proton pencil beams were simulated in Geant4 to provide the system matrix A whose elements a-ij correspond to the dose delivered to pixel i by a unit intensity pencil beam j. A cyclic orthogonal projections algorithm was applied with the goal of finding a pencil beam intensity distribution that would meet the following dose requirements: D-OAR < 54 Gy and 57 Gy < D-PTV < 64.2 Gy. The cyclic algorithm was based on the concept of orthogonal projections onto half-spaces according to the Agmon-Motzkin-Schoenberg algorithm, also known as ‘ART for inequalities’. Results: The cyclic orthogonal projections algorithm resulted in less than 5% of the PTV pixels and less than 1% of OAR pixels violating their dose constraints, respectively. Because of the abutting OAR-PTV geometry and the realistic modelling of the pencil beam penumbra, complete satisfaction of the dose objectives was not achieved, although this would be a clinically acceptable plan for a meningioma abutting the brainstem, for example. Conclusion: The cyclic orthogonal projections algorithm was demonstrated to be an effective tool for inverse IMPT planning in the 2D test geometry described. We plan to further develop this linear algorithm to be capable of incorporating dose-volume constraints into the feasibility-seeking algorithm.

60 APPLIED LIFE SCIENCES↗

Quantum noise properties of CT images with anatomical textured backgrounds across reconstruction algorithms: FBP and SAFIRE

Purpose: Quantum noise properties of CT images are generally assessed using simple geometric phantoms with uniform backgrounds. Such phantoms may be inadequate when assessing nonlinear reconstruction or postprocessing algorithms. The purpose of this study was to design anatomically informed textured phantoms and use the phantoms to assess quantum noise properties across two clinically available reconstruction algorithms, filtered back projection (FBP) and sinogram affirmed iterative reconstruction (SAFIRE). Methods: Two phantoms were designed to represent lung and soft-tissue textures. The lung phantom included intricate vessel-like structures along with embedded nodules (spherical, lobulated, and spiculated). The soft tissue phantom was designed based on a three-dimensional clustered lumpy background with included low-contrast lesions (spherical and anthropomorphic). The phantoms were built using rapid prototyping (3D printing) technology and, along with a uniform phantom of similar size, were imaged on a Siemens SOMATOM Definition Flash CT scanner and reconstructed with FBP and SAFIRE. Fifty repeated acquisitions were acquired for each background type and noise was assessed by estimating pixel-value statistics, such as standard deviation (i.e., noise magnitude), autocorrelation, and noise power spectrum. Noise stationarity was also assessed by examining the spatial distribution of noise magnitude. The noise properties were compared across background types and between the two reconstruction algorithms. Results: In FBP and SAFIRE images, noise was globally nonstationary for all phantoms. In FBP images of all phantoms, and in SAFIRE images of the uniform phantom, noise appeared to be locally stationary (within a reasonably small region of interest). Noise was locally nonstationary in SAFIRE images of the textured phantoms with edge pixels showing higher noise magnitude compared to pixels in more homogenous regions. For pixels in uniform regions, noise magnitude was reduced by an average of 60% in SAFIRE images compared to FBP. However, for edge pixels, noise magnitude ranged from 20% higher to 40% lower in SAFIRE images compared to FBP. SAFIRE images of the lung phantom exhibited distinct regions with varying noise texture (i.e., noise autocorrelation/power spectra). Conclusions: Quantum noise properties observed in uniform phantoms may not be representative of those in actual patients for nonlinear reconstruction algorithms. Anatomical texture should be considered when evaluating the performance of CT systems that use such nonlinear algorithms.

60 APPLIED LIFE SCIENCES↗

An approach to multiobjective optimization of rotational therapy

Multiobjective optimization is used in radiotherapy, especially IMRT, to generate treatment plans which meet different objectives to varying extents. Trade-off surfaces can be constructed representing the gains and losses of different objectives when switching from one plan to another, and the planner can interactively explore different treatment possibilities without the need for reoptimization. In this work a method for the multiobjective optimization of rotational therapy is introduced. The proposed method is applied slice per slice and uses the geometry of the slice directly to construct several arcs, each conformally irradiating the tumor and blocking a number (0,1,2,...) of different organs at risk present in the treatment. The blocked arc dose distributions so obtained are quite inhomogeneous in the target. An algorithm, based on the iterative reconstruction of images from projections, has been developed to compensate for this inhomogeneity, leading to compensated blocked arcs which deliver more uniform target doses but still block critical structures. Different treatments can be obtained as linear combinations of these arcs, each involving different trade-offs among the objectives involved. The compensatory algorithm substantially improves the target dose uniformity of blocked arcs at the cost of slightly increasing the dose to the rest of the body, allowing delivery of good uniform dose distributions to the target without significantly irradiating the blocked organ(s). Trade-off surfaces are presented for slices containing a target and one or two critical structures. The method is directly implementable using axial or helical tomotherapy. Implementation for conventional linear accelerators will be more difficult because the number of arcs needed to deliver such treatments can be large, an issue to be explored in future work.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-AB-303-09: Rapid Projection Computations for On-Board Digital Tomosynthesis in Radiation Therapy

Purpose: To facilitate fast and accurate iterative volumetric image reconstruction from limited-angle on-board projections. Methods: Intrafraction motion hinders the clinical applicability of modern radiotherapy techniques, such as lung stereotactic body radiation therapy (SBRT). The LIVE system may impact clinical practice by recovering volumetric information via Digital Tomosynthesis (DTS), thus entailing low time and radiation dose for image acquisition during treatment. The DTS is estimated as a deformation of prior CT via iterative registration with on-board images; this shifts the challenge to the computational domain, owing largely to repeated projection computations across iterations. We address this issue by composing efficient digital projection operators from their constituent parts. This allows us to separate the static (projection geometry) and dynamic (volume/image data) parts of projection operations by means of pre-computations, enabling fast on-board processing, while also relaxing constraints on underlying numerical models (e.g. regridding interpolation kernels). Further decoupling the projectors into simpler ones ensures the incurred memory overhead remains low, within the capacity of a single GPU. These operators depend only on the treatment plan and may be reused across iterations and patients. The dynamic processing load is kept to a minimum and maps well to the GPU computational model. Results: We have integrated efficient, pre-computable modules for volumetric ray-casting and FDK-based back-projection with the LIVE processing pipeline. Our results show a 60x acceleration of the DTS computations, compared to the previous version, using a single GPU; presently, reconstruction is attained within a couple of minutes. The present implementation allows for significant flexibility in terms of the numerical and operational projection model; we are investigating the benefit of further optimizations and accurate digital projection sub-kernels. Conclusion: Composable projection operators constitute a versatile research tool which can greatly accelerate iterative registration algorithms and may be conducive to the clinical applicability of LIVE. National Institutes of Health Grant No. R01-CA184173; GPU donation by NVIDIA Corporation.

60 APPLIED LIFE SCIENCES↗