Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Resonant four-photon scattering of collinear laser pulses in plasma

Exact four-photon resonance of collinear planar laser pulses is known to be prohibited by the classical dispersion law of electromagnetic waves in plasma. We show here that the renormalization produced by an arbitrarily small relativistic electron nonlinearity removes this prohibition. The laser frequency shifts in collinear resonant four-photon scattering increase with laser intensities. For laser pulses of frequencies much greater than the electron plasma frequency, the shifts can also be much greater than the plasma frequency and even nearly double the input laser frequency at still small relativistic electron nonlinearities. Furthermore, this may enable broad range tunable lasers of very high frequencies and powers. Since the four-photon scattering does not rely on the Langmuir wave, which is very sensitive to plasma homogeneity, such lasers would also be able to operate at much larger plasma inhomogeneities than lasers based on stimulated Raman scattering in plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emission Inventories from Natural Gas Storage Facilities using Regional Frequency Comb Laser Monitoring and Aircraft Flyovers. Final Report

The project centers around a ground-based regional methane sensor developed by the CU/NIST team members under the DOE ARPA-E MONITOR program, and sophisticated aircraft measurement techniques developed by the UCD/Scientific Aviation team (responsible for a recent Science publication quantifying the Aliso Canyon storage field release). The dual frequency-comb spectrometer is an invisible, eye-safe laser capable of measuring atmospheric methane concentrations along beam paths 1+ miles in length with high precision and stability (<1 ppb methane over 1 mile). The CU/NIST team has developed a unique approach to using a single, central spectrometer to locate and size methane emissions as small as 6 scfh from specific gas field structures within the 1+ mile range of the laser. Deployment involves the stationing of small cubic mirrors at strategic locations across the gas storage site. The mirrors direct light from the spectrometer back to a detector, where methane concentrations are recorded based on light absorption at specific wavelengths. The measurements are coupled with high resolution gas transport models based on meteorological measurements (wind, etc.) to determine the precise location and emission rate of methane sources. The calibration-free and continuous nature of dual frequency-comb spectrometer measurements means that a large area can be monitored continuously for temporal variability of emissions over long periods of time. The aircraft measurements involve spiral flights around storage facilities with a sensitive ethane/methane measurement package. Upwind/downwind concentration comparisons and wind data provide total facility emissions data. During this project, a new micrometeorological package was integrated onto the Scientific Aviation aircraft to provide even greater emissions quantification capability. In this project, the ground-based measurement system was deployed for 11 months (to capture seasonal variability) at a West Coast storage facility, together with a campaign of twice monthly aircraft total facility emissions flights. The data from these two modalities was combined to quantify the methane emissions from the facility with first-of-its-kind temporal and spatial detail. Concurrent with this deployment, the aircraft team performed flights to quantify emissions at a wider array of previously un-surveyed storage sites. The ground-based measurement system was then moved to an additional site of differing total storage and delivery capacity. Aircraft mass balance flights continued, repeatedly surveying (twice monthly) this site, as well as surveying a large number of previously un-assessed sites spanning a variety of size, reservoir type and age. Assessment of ground-based, temporally and spatially detailed methane emissions information alongside aircraft-derived methane total facility emissions information led to an improved understanding of emissions, relevant for inventories of the natural gas storage sector. In particular, this work provided temporal detail (seasonal of emissions and frequency of leaks) to stakeholders and personnel responsible for updates to the EPA’s GHGI. The impact of the proposed work has been a dramatic improvement in the temporal, spatial, and site- and type- specific detail and quantification of emissions inventories for the natural gas storage sector. This work directly benefits the EPA’s GHGI, directly ameliorates the environmental impacts and public health and safety of the natural gas storage sector, and aids policymakers and industry to make sound choices with respect to management and regulation.

03 NATURAL GAS↗

Excalibur: A Nonparametric, Hierarchical Wavelength Calibration Method for a Precision Spectrograph

Excalibur is a nonparametric, hierarchical framework for precision wavelength calibration of spectrographs. It is designed with the needs of extreme-precision radial-velocity (EPRV) instruments in mind, which require calibration or stabilization to better than 10{sup −4} pixels. Instruments vary along only a few dominant degrees of freedom, especially EPRV instruments that feature highly stabilized optical systems and detectors. Excalibur takes advantage of this property by using all calibration data to construct a low-dimensional representation of all accessible calibration states for an instrument. Excalibur also takes advantage of laser-frequency combs or etalons, which generate a dense set of stable calibration points. This density permits the use of a nonparametric wavelength solution that can adapt to any instrument or detector oddities better than parametric models, such as a polynomial. We demonstrate the success of this method with data from the Extreme Precision Spectrograph (EXPRES), which uses a laser-frequency comb. When wavelengths are assigned to laser comb lines using excalibur, the rms of the residuals is about one-fifth that of wavelengths assigned using polynomial fits to individual exposures. Radial-velocity measurements of HD 34411 show a reduction in rms scatter over a 10 month time baseline from 1.17 to 1.05 m s{sup −1}.

47 OTHER INSTRUMENTATION↗

Single-Step Fabrication of Au-Fe-BaTiO3 Nanocomposite Thin Films Embedded with Non-Equilibrium Au-Fe Alloyed Nanostructures

Nanocomposite thin film materials present great opportunities in coupling materials and functionalities in unique nanostructures including nanoparticles-in-matrix, vertically aligned nanocomposites (VANs), and nanolayers. Interestingly the nanocomposites processed through a non-equilibrium processing method, e.g., pulsed laser deposition (PLD), often possess unique metastable phases and microstructures that could not achieve using equilibrium techniques, and thus lead to novel physical properties. In this work, a unique three-phase system composed of BaTiO3 (BTO), with two immiscible metals, Au and Fe, is demonstrated. By adjusting the deposition laser frequency from 2 Hz to 10 Hz, the phase and morphology of Au and Fe nanoparticles in BTO matrix vary from separated Au and Fe nanoparticles to well-mixed Au-Fe alloy pillars. This is attributed to the non-equilibrium process of PLD and the limited diffusion under high laser frequency (e.g., 10 Hz). The magnetic and optical properties are effectively tuned based on the morphology variation. This work demonstrates the stabilization of non-equilibrium alloy structures in the VAN form and allows for the exploration of new non-equilibrium materials systems and their properties that could not be easily achieved through traditional equilibrium methods.

36 MATERIALS SCIENCE↗

Cumulative fidelity of large-momentum-transfer clock atom interferometers in the presence of laser noise

Clock atom interferometry is an emerging technique in precision measurements that is particularly well suited for sensitivity enhancement through large momentum transfer (LMT). While current systems have demonstrated momentum separations of several hundreds of photon momenta, next-generation quantum sensors are targeting an LMT enhancement factor beyond 10 4 . However, the viability of LMT clock interferometers has recently come into question due to the potential impact of laser frequency noise. Here, in this work, we resolve this concern by analyzing the cumulative fidelity of sequential state inversions in an LMT atom interferometer. We show that the population error from 𝑛 pulses applied from alternating directions scales linearly with 𝑛. This is a significant advantage over the 𝑛 2 scaling that occurs when probing a two-level system 𝑛 times from the same direction. We further show that contributions to the interferometer signal from parasitic paths generated by imperfect pulses are negligible, for any loss mechanism. These results establish that laser frequency noise is not a practical limitation for the development of high-fidelity LMT clock atom interferometers.

Mach-Zehnder atom interferometry↗

Measurement of shock roughness due to phase plate speckle imprinting relevant for x-ray diffraction experiments on 3rd and 4th generation light sources

Laser-shock compression experiments at 3rd and 4th generation light sources generally employ phase plates, which are inserted into the beamline to achieve a repeatable intensity distribution at the focal plane. Here, the laser intensity profile is characterized by a high-contrast, high-frequency laser speckle. Without sufficient smoothing, these laser non-uniformities can translate to a significant pressure distribution within the sample layer and can affect data interpretation in x-ray diffraction experiments. Here, we use a combination of one- and two-dimensional velocity interferometry to directly measure the extent to which spatial frequencies within the laser focal spot intensity pattern are smoothed out during propagation within the laser plasma and a polyimide ablator. We find that the use of thicker polyimide layers results in spatially smoother shock fronts, with the greatest degree of smoothing associated with the highest spatial frequencies. Focal spots with the smallest initial speckle separation produce the most rapid smoothing. Laser systems that employ smoothing by spectral dispersion techniques to rapidly modulate the focal plane intensity distribution are shown to be the most effective ones in producing a spatially smooth shock front. We show that a simple transport model combined with the known polyimide Hugoniot adequately describes the extent of shock smoothness as a function of polyimide thickness. Finally, our results provide a description of spatial structure smoothing across a shock front, which can be used to design targets on x-ray free electron laser facilities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accuracy of the time-averaged ponderomotive approximation for laser-plasma accelerator modeling

Reliable modeling of laser-plasma accelerators, where a short and intense laser pulse propagates in an underdense plasma over long distances, is a computationally challenging task. This is due to the great disparity among the scales involved in the modeling, ranging from the micrometer scale of the laser wavelength to, for instance, the meter scale of the laser-plasma interaction length for a multi-GeV-class laser-plasma accelerator. To reduce such imbalance, the time-averaged ponderomotive approximation may be used, where the plasma particle dynamics is analytically averaged over the laser frequency, and only spatiotemporal scales associated with the laser envelope are retained in the calculations, resulting in significant computational savings. Here, we characterize the accuracy and robustness of the time-averaged ponderomotive approximation for a range of laser parameters of interest for present and future laser-plasma accelerators, and we show that the error introduced by the averaging process is small in all relevant cases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Narrow-bandwidth tunable optical filter stabilized by Newton’s rings fringe analysis

The resolution of grating spectrometers is insufficient to resolve many features present in the emission spectra of solid-state quantum emitters. Spectral resolution may be improved by inserting a Fabry–Perot interferometer (FPI) whose length is tuned by a piezoelectric actuator. Yet piezo creep and thermal fluctuations cause instability that makes this solution unsuitable for measurement times longer than tens of seconds. To overcome this challenge, we employ active feedback derived from the Newton’s rings interference pattern formed by the reflection of a single-frequency laser from the FPI cavity. The resulting FPI transmission frequency is stable to within 50 MHz over several hours.

KC, Raju Bhai (ORCID:0000000267406588)↗

Collective plasma effects of electron–positron pairs in beam-driven QED cascades

Understanding the interplay of strong-field QED and collective plasma effects is important for explaining extreme astrophysical environments like magnetars. It has been shown that QED pair plasma can be produced and observed by passing a relativistic electron beam through an intense laser field. This work presents in detail multiple sets of 3D QED-particle-in-cell simulations to show the creation of pair plasma in the QED cascade. The beam driven method enables a high pair particle density and also a low particle Lorentz factor, which both play equal roles on exhibiting large collective plasma effects. Finite laser frequency upshift is observed with both ideal parameters (24 PW laser colliding with a 300 GeV electron beam) and with existing technologies (3 PW laser colliding with a 30 GeV electron beam).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New Fracture Diagnostic Tool for Unconventionals: High-Resolution Distributed Strain Sensing via Rayleigh Frequency Shift during Production in Hydraulic Fracture Test 2

Fiber Optic monitoring in unconventional reservoirs has proven to be an invaluable diagnostic tool for assessing both near-wellbore stimulation effectiveness and to help describe the far-field frac geometries created by hydraulic fracture stimulation. Unfortunately, gaining any detailed qualitative and quantitative understanding of the near-wellbore frac geometry or cluster/stage productivity during production via Fiber Optic (FO) has proven to be more difficult, particularly in wells producing liquids. A new FO diagnostic method, Distributed Strain Sensing based on Rayleigh Frequency Shift (DSS-RFS), first demonstrated for oil and gas applications in the Hydraulic Test Site 2 (HFTS2) provides new insights about the characteristics of near-wellbore-region (NWR) during production. DSS-RFS is different from other FO strain measurements because it relies on accurate measurement of frequency shifts of Rayleigh backscattered spectrum obtained by scanning the fiber with a coherent optical time-domain reflectometer with a range of laser frequencies using a tunable-wavelength laser system. Changes in strain are measured with an extremely high spatial resolution of 20 cm and with high signal-to-noise ratios over long distances. In HFTS2, strain changes for the entire wellbore have been measured twice during scheduled shut-in and reopening operations (February 2020 and September 2020). After removing temperature effects, consistent strain changes have been observed at the location of most perforation clusters. These are caused by near wellbore fracture aperture changes due to pressure increases during shut-in within the near-wellbore fracture network. The strain-change patterns from the DSS-RFS during shut-in correlate very well with the location of clusters and allow for the definition of extending intervals with positive strain signals at each cluster and slightly compressing intervals with negative strain signals between the clusters and in the non stimulated intervals. The locations of the measured positive strain peaks also show good correspondence to DAS acoustic intensity measurements acquired during the stimulation. The geometry and magnitude of the strain changes differ significantly between the two tested completion designs in the same well. During shut in and reopening each cluster exhibit its own strain-change / pressure path. In addition, the September 2020 dataset also revealed the existence of small but measurable strain changes as consequence of pressure decline during production. These strain changes also correlate well with the presence of producing clusters, but the strain-rate signals are opposite to that obtained during shut-in and reopening operations. Although Downloaded from http://onepetro.org/URTECONF/proceedings-pdf/21URTC/2-21URTC/D021S031R002/2477551/urtec-2021-5408-ms.pdf/1 by Carol Worster on 28 February 2022 URTeC 5408 2 we are still in the early stages of exploring the potential of this novel FO technique, we believe that the highly detailed information contained in the measurement of strain changes using DSS-RFS during production can significantly improve our understanding of near-wellbore hydraulic fracture characteristics and the relationships between stimulation and production from unconventional oil and gas wells.

04 OIL SHALES AND TAR SANDS↗

Implementing an electronic sideband offset lock for isotope shift spectroscopy in radium

We demonstrate laser frequency stabilization with at least 6 GHz of offset tunability using an in-phase/quadrature (IQ) modulator to generate electronic sidebands (ESB) on a titanium sapphire laser at 714 nm and we apply this technique to perform isotope shift spectroscopy of 226 Ra and 225 Ra. By locking the laser to a single resonance of a high finesse optical cavity and adjusting the lock offset, we determine the frequency difference between the magneto-optical trap (MOT) transitions in the two isotopes to be 2630.0 ± 0.3 MHz, a factor of 29 more precise than the previously available data. Using the known value of the hyperfine splitting of the 3 P 1 level, we calculate the isotope shift for the 1 S 0 to 3 P 1 transition to be 2267.0 ± 2.2 MHz, a factor of 8 more precise than the best available value. Our technique could be applied to countless other atomic systems to provide unprecedented precision in isotope shift spectroscopy and other relative frequency comparisons.

47 OTHER INSTRUMENTATION↗

Continuous-wave GaAs/AlGaAs quantum cascade laser at 5.7 THz

Design strategies for improving terahertz (THz) quantum cascade lasers (QCLs) in the 5–6 THz range are investigated numerically and experimentally, with the goal of overcoming the degradation in performance that occurs as the laser frequency approaches the Reststrahlen band. Two designs aimed at 5.4 THz were selected: one optimized for lower power dissipation and one optimized for better temperature performance. The active regions exhibited broadband gain, with the strongest modes lasing in the 5.3–5.6 THz range, but with other various modes observed ranging from 4.76 to 6.03 THz. Pulsed and continuous-wave (cw) operation is observed up to temperatures of 117 K and 68 K, respectively. In cw mode, the ridge laser has modes up to 5.71 THz – the highest reported frequency for a THz QCL in cw mode. The waveguide loss associated with the doped contact layers and metallization is identified as a critical limitation to performance above 5 THz.

47 OTHER INSTRUMENTATION↗

Compact laser source with frequency modulators generating multiple lines

A compact laser source and a single sideband modulator used therein is disclosed. The compact laser source includes a seed laser and one or more channels, with each channel generating one or more output laser beams having corresponding different wavelengths. The compact laser source can be formed in whole or in part on a single optical motherboard to thereby minimize space and power requirements. By employing the disclosed single sideband modulator, harmonics in the generated output laser beams can be minimized. The compact laser source finds application in an atom interferometer (AI) system, which may be used to measure gravity, acceleration, or rotation of the AI system.

Lentine, Anthony L.↗

Tunable UV ∼ IR frequency comb generation via high-order sideband generation

Abstract We propose the generation of a widely tunable UV-to-IR frequency comb by high-order sideband generation (HSB) spectrum emitted from semiconductors. In our theoretical simulations, we demonstrate the high-order sideband signals of two series (2m Ω seed + (2n + 1) ω driver , and (2m + 1) Ω seed + 2 n ω driver ), wheremandnare integers of a seed pulse and a driver laser frequency, respectively. The simulations also reveal the intensity of HSB scale with the driver laser power, both perturbatively and non-perturbatively. We find that the harmonic position and spacing of the high-order sideband emission can be controlled by varying the seed pulse and driver photon energies. In the experiment, we applied a visible ( ℏ Ω seed = 3.1 eV, ∼400 nm) seed pulse and mid-infrared (MIR, ℏ ω driver = 0.4 eV, 3.1 μm) driver pulses to ZnSe target. Our experimental observations confirmed the UV (4.7 eV, 263 nm and 3.9 eV, 317 nm) HSB generation.

Physics↗

High-angular-momentum Rydberg states in a room-temperature vapor cell for dc electric-field sensing

We prepare and analyze Rydberg states with orbital quantum numbers ℓ ≤ 6 using three-optical-photon electromagnetically induced transparency (EIT) and radio frequency (rf) dressing, and employ the high- ℓ states in electric-field sensing. Rubidium-85 atoms in a room-temperature vapor cell are first promoted into the 25 F 5 / 2 state via Rydberg-EIT with three infrared laser beams. Two rf dressing fields then (near-)resonantly couple the 25 F , 25 H ( ℓ = 5 ) , and 25 I ( ℓ = 6 ) Rydberg states. The dependence of the rf-dressed Rydberg-state level structure on rf powers, rf and laser frequencies is characterized using EIT. Furthermore, we discuss the principles of dc-electric-field sensing using high- ℓ Rydberg states and experimentally demonstrate the method using test electric fields of ≲ 50 V/m induced via photo-illumination of the vapor-cell wall. We measure the highly nonlinear dependence of the dc-electric-field strength on the power of the photo-illumination laser. Numerical calculations, which reproduce our experimental observations well, elucidate the underlying physics. Our paper is relevant to high-precision spectroscopy of high- ℓ Rydberg states, Rydberg-atom-based electric-field sensing, and plasma electric-field diagnostics. Published by the American Physical Society 2024

Duspayev, Alisher (ORCID:0000000153225762)↗

457-nm radiation source based on a diode laser for precision spectroscopy of magnesium atoms

We report on the development of a highly stable source of 457-nm radiation based on a diode laser and a tapered amplifier operating in a double-pass scheme. The diode laser frequency was stabilised by a high-Q reference Fabry – Perot interferometer and doubled in a PPSLT nonlinear crystal placed in an enhancement cavity. At a maximum output power of 200 mW at a wavelength of 457 nm, the laser linewidth was less than 5 kHz. The radiation source operation was demonstrated in experiments on precision spectroscopy of cold magnesium atoms in a magneto-optical trap. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On measuring stimulated photon–photon scattering using multiple ultraintense lasers

Stimulated photon–photon scattering is a predicted consequence of quantum electrodynamics that has yet to be measured directly. Measuring the cross section for stimulated photon–photon scattering is the aim of a flagship experiment for NSF OPAL, a proposed laser user facility with two, 25-PW beamlines. We present optimized experimental designs for achieving this challenging and canonical measurement. A family of experimental geometries is identified that satisfies the momentum- and energy-matching conditions for two selected laser frequency options. Numerical models predict a maximum signal exceeding 1000 scattered photons per shot at the experimental conditions envisaged at NSF OPAL. Experimental requirements on collision geometry, polarization, cotiming and copointing, background suppression, and diagnostic technologies are investigated numerically. These results confirm that a beam cotiming shorter than the pulse duration and control of the copointing on a scale smaller than the shortest laser wavelength are needed to robustly scatter photons on a per-shot basis. Finally, we assess the bounds that a successful execution of this experiment may place on the mass scale of Born–Infeld nonlinear electrodynamics beyond the standard model of physics.

Beyond the Standard Model↗