Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Linearity Analysis and Efficiency Testing of The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) Science Cameras for Flight

To unveil the complexity of the solar atmosphere, measurement of the magnetic field in the upper chromosphere and transition region is fundamentally important, as this is where the forces transition from plasma to magnetic field dominated. Measurements of the field are also needed to elucidate the energy transport from the lower atmospheric regions to the corona beyond. Such an advance in heliospheric knowledge became possible with the first flight of the international solar sounding rocket mission, CLASP. For the first time, linear polarization was measured in Hydrogen Lyman-Alpha at 121.60 nm in September 2015. For linear polarization measurements in this emission line, high sensitivity is required due to the relatively weak polarization signal compared to the intensity. To achieve this high sensitivity, a low-noise sensor is required with good knowledge of its characterization, including linearity. This work presents further refinement of the linearity characterization of the cameras flown in 2015. We compared the current from a photodiode in the light path to the digital response of the detectors. Pre-flight CCD linearity measurements were taken for all three flight cameras and calculations of the linear fits and residuals were performed. However, the previous calculations included a smearing pattern and a digital saturation region on the detectors which were not properly taken into account. The calculations have been adjusted and were repeated for manually chosen sub-regions on the detectors that were found not to be affected. We present a brief overview of the instrument, the calibration data and procedures, and a comparison of the old and new linearity results. The CLASP cameras will be reused for the successor mission, CLASP2, which will measure the Magnesium II h & k emission lines between 279.45 nm and 280.35 nm. The new approach will help to better prepare for and to improve the camera characterization for CLASP2.

detector↗

An accurate registration technique for distorted images

Accurate registration of International Ultraviolet Explorer (IUE) images is crucial because the variability of the geometrical distortions that are introduced by the SEC-Vidicon cameras ensures that raw science images are never perfectly aligned with the Intensity Transfer Functions (ITFs) (i.e., graded floodlamp exposures that are used to linearize and normalize the camera response). A technique for precisely registering IUE images which uses a cross correlation of the fixed pattern that exists in all raw IUE images is described.

Delapena, Michele↗

Experimental Investigation of a Graphite-Composite Intertank Section for a Reusable Launch Vehicle

The use of graphite-composites as primary structure is essential for the development of a cost effective single-stage-to-orbit reusable launch vehicle (RLV). A full-scale segment of a graphite-composite intertank was designed and fabricated by an industry team and tested at NASA Langley Research Center as a part of the RLV technology development program. The intertank test component was approximately 3.0 m long by 6.7 m wide and included slightly less than a 90deg section of a cylindrical intertank. The test article was fabricated using graphite-bismaelimide composite material and consisted of a hat-stiffened skin with five ring frames. The stiffeners were secondarily bonded to the panel skin and the ring frames were mechanically attached. The test article was loaded to failure with a uniform compression load applied by 21 individually controlled hydraulic actuators. Resistance strain gages, linear variable differential transformers and video cameras were used to measure and record the test results. A linear f d t e element analysis of the test article and test fixture was performed. The test results verified the structural integrity cf the intertank test article up to the design limit load. However, the test article failed in general skin buckling between the ring frames at a load 1.08 times design limit load. This load was considerably lower than the expected failure load. The cause of premature failure is being investigated. Good correlation of the test and analysis results was obtained for loads up to the design limit load.

Sawyer, James Wayne↗

Replacing the Polarizer Wheel with a Polarization Camera to Increase the Temporal Resolution and Reduce the Overall Complexity of a Solar Coronagraph

Experiments that require linearly polarized brightness measurements, traditionally have obtained three successive images through a linear polarizer that is rotated through three well-defined angles and the images are combined to get the linearly polarized brightness. This technique requires a mechanism to hold the linear polarizer in place and to precisely turn it through the three angles. Obviously, the temporal resolution is lost in such a scenario, since the three images that are used to derive the linearly polarized brightness are taken at three different times. Specifically, in a dynamic corona that is in constant reshaping of its structures, the linearly polarized brightness image produced in this manner may not yield true values all around the corona. In this regard, with the advent of the polarization camera, the linearly polarized brightness can be measured from a single image. This also eliminates the need for a linear polarizer and the associated rotator mechanisms and can contribute toward lower weight, size, power requirements, overall risk of the instrument, and most importantly, increase the temporal resolution. We evaluate the capabilities of a selected polarization camera and how these capabilities could be tested in a ground experiment conducted in conjunction with a total solar eclipse. The ground experiment requires the measurement of the linearly polarized brightness, also known as K-corona, in a corona that also contains unpolarized brightness, known as F-corona, in order to measure three important physical properties pertaining to coronal electrons, namely, the electron density, electron temperature, and the electron speed.

Reginald, Nelson L.↗

Ga:Ge array development

Work at the University of Arizona and at Lawrence Berkeley Laboratory on the development of a far infrared array camera for the Multiband Imaging Photometer on the Space Infrared Telescope Facility (SIRTF) is discussed. The camera design uses stacked linear arrays of Ge:Ga photoconductors to make a full two-dimensional array. Initial results from a 1 x 16 array using a thermally isolated J-FET readout are presented. Dark currents below 300 electrons s(exp -1) and readout noises of 60 electrons were attained. Operation of these types of detectors in an ionizing radiation environment are discussed. Results of radiation testing using both low energy gamma rays and protons are given. Work on advanced C-MOS cascode readouts that promise lower temperature operation and higher levels of performance than the current J-FET based devices is described.

Young, Erick T.↗

Study of optical techniques for the Ames unitary wind tunnels. Part 3: Angle of attack

A review of optical sensors that are capable of accurate angle of attack measurements in wind tunnels was conducted. These include sensors being used or being developed at NASA Ames and Langley Research Centers, Boeing Airplane Company, McDonald Aircraft Company, Arnold Engineering Development Center, National Aerospace Laboratory of the Netherlands, National Research Council of Canada, and the Royal Aircraft Establishment of England. Some commercial sensors that may be applicable to accurate angle measurements were also reviewed. It was found that the optical sensor systems were based on interferometers, polarized light detector, linear or area photodiode cameras, position sensing photodetectors, and laser scanners. Several of the optical sensors can meet the requirements of the Ames Unitary Plan Wind Tunnel. Two of these, the Boeing interferometer and the Complere lateral effect photodiode sensors are being developed for the Ames Unitary Plan Wind Tunnel.

Lee, George↗

A Method to Solve Interior and Exterior Camera Calibration Parameters for Image Resection

An iterative method is presented to solve the internal and external camera calibration parameters, given model target points and their images from one or more camera locations. The direct linear transform formulation was used to obtain a guess for the iterative method, and herein lies one of the strengths of the present method. In all test cases, the method converged to the correct solution. In general, an overdetermined system of nonlinear equations is solved in the least-squares sense. The iterative method presented is based on Newton-Raphson for solving systems of nonlinear algebraic equations. The Jacobian is analytically derived and the pseudo-inverse of the Jacobian is obtained by singular value decomposition.

Samtaney, Ravi↗

Photogrammetry Applied to Wind Tunnel Testing

In image-based measurements, quantitative image data must be mapped to three-dimensional object space. Analytical photogrammetric methods, which may be used to accomplish this task, are discussed from the viewpoint of experimental fluid dynamicists. The Direct Linear Transformation (DLT) for camera calibration, used in pressure sensitive paint, is summarized. An optimization method for camera calibration is developed that can be used to determine the camera calibration parameters, including those describing lens distortion, from a single image. Combined with the DLT method, this method allows a rapid and comprehensive in-situ camera calibration and therefore is particularly useful for quantitative flow visualization and other measurements such as model attitude and deformation in production wind tunnels. The paper also includes a brief description of typical photogrammetric applications to temperature- and pressure-sensitive paint measurements and model deformation measurements in wind tunnels.

Liu, Tian-Shu↗

Palomar Prime-Focus Infrared Camera (PFIRCAM)

In a joint effort between engineers and scientists at the Jet Propulsion Laboratory and the California Institute of Technology, a near-infrared direct imaging system has been developed and integrated into the Caltech Palomar Observatory detector series.

Palamar↗

A Simple Approach of CCD Camera Calibration for Optical Diagnostics Instrumentation

Solid State array sensors are ubiquitous nowadays for obtaining gross field images in numerous scientific and engineering applications including optical diagnostics and instrumentation. Linear responses of these sensors are often required as in interferometry, light scattering and attenuation measurements, and photometry. In most applications, the linearity is usually taken to be granted without thorough quantitative assessment or correction through calibration. Upper-grade CCD cameras of high price may offer better linearity: however, they also require linearity checking and correction if necessary. Intermediate- or low-grade CCD cameras are more likely to need calibration for linearity . Here, we present two very simple approaches: one for quickly checking camera linearity without any additional setup and one for precisely correcting nonlinear sensor responses. It is believed that after calibration, those sensors of intermediate or low grade can function as effectively as their expensive counterpart.

Cha, Soyoung Stephen↗

Improving Photometric Calibration of Meteor Video Camera Systems

We present the results of new calibration tests performed by the NASA Meteoroid Environment Oce (MEO) designed to help quantify and minimize systematic uncertainties in meteor photometry from video camera observations. These systematic uncertainties can be categorized by two main sources: an imperfect understanding of the linearity correction for the MEO's Watec 902H2 Ultimate video cameras and uncertainties in meteor magnitudes arising from transformations between the Watec camera's Sony EX-View HAD bandpass and the bandpasses used to determine reference star magnitudes. To address the rst point, we have measured the linearity response of the MEO's standard meteor video cameras using two independent laboratory tests on eight cameras. Our empirically determined linearity correction is critical for performing accurate photometry at low camera intensity levels. With regards to the second point, we have calculated synthetic magnitudes in the EX bandpass for reference stars. These synthetic magnitudes enable direct calculations of the meteor's photometric ux within the camera band-pass without requiring any assumptions of its spectral energy distribution. Systematic uncertainties in the synthetic magnitudes of individual reference stars are estimated at 0:20 mag, and are limited by the available spectral information in the reference catalogs. These two improvements allow for zero-points accurate to 0:05 􀀀 0:10 mag in both ltered and un ltered camera observations with no evidence for lingering systematics.

Ehlert, Steven↗

Improving Photometric Calibration of Meteor Video Camera Systems

We present the results of new calibration tests performed by the NASA Meteoroid Environment Office (MEO) designed to help quantify and minimize systematic uncertainties in meteor photometry from video camera observations. These systematic uncertainties can be categorized by two main sources: an imperfect understanding of the linearity correction for the MEO's Watec 902H2 Ultimate video cameras and uncertainties in meteor magnitudes arising from transformations between the Watec camera's Sony EX-View HAD bandpass and the bandpasses used to determine reference star magnitudes. To address the first point, we have measured the linearity response of the MEO's standard meteor video cameras using two independent laboratory tests on eight cameras. Our empirically determined linearity correction is critical for performing accurate photometry at low camera intensity levels. With regards to the second point, we have calculated synthetic magnitudes in the EX bandpass for reference stars. These synthetic magnitudes enable direct calculations of the meteor's photometric flux within the camera bandpass without requiring any assumptions of its spectral energy distribution. Systematic uncertainties in the synthetic magnitudes of individual reference stars are estimated at approx. 0.20 mag, and are limited by the available spectral information in the reference catalogs. These two improvements allow for zero-points accurate to 0.05 - 0.10 mag in both filtered and unfiltered camera observations with no evidence for lingering systematics. These improvements are essential to accurately measuring photometric masses of individual meteors and source mass indexes.

Steven Ehlert↗

Television camera as a scientific instrument

Rigorous calibration program, coupled with a sophisticated data-processing program that introduced compensation for system response to correct photometry, geometric linearity, and resolution, converted a television camera to a quantitative measuring instrument. The output data are in the forms of both numeric printout records and photographs.

Smokler, M. I.↗

Statistical Error Analysis on White-Light Filter Ratio Experiments to Measure Electron Parameters

The Filter ratio technique to remotely measure electron temperature and speed using four color filters in visible light and a polarization camera was described in detail in four articles by Reginald et al., Solar physics, (2018, 2019a, 2019b, 2020). In these four articles we quantified the systematic error associated with using models of symmetric corona to interpret results from asymmetric corona. We also showed the criteria applied to select the bandwidths of filters, and the pros and cons of replacing the traditional linear polarizer with a polarization camera to measure pB. What started in 1990s as ground experiments conducted during total solar eclipses that lasted for a few minutes lead to a balloon borne experiment lasting eight hours in 2019 and will blossom into a space experiment on the International Space Station in 2023. Due to constraints on the bandwidths of the four filters, a successful mission requires quantification of the statistical error using Monte Carlo simulation to generate two feasibility profiles, which are unique to the design parameters of the coronagraph, to comprehend the feasibility to measure temperature and speed within the desired temporal and spatial resolutions. For the statistical error analysis, we use modeled K and F corona profiles, representative theoretical diffraction, scattering, and vignetting profiles, assumed efficiencies for lenses, mirrors, and polarizers, assumed detector properties on quantum efficiency, full well depth, dark noise, and read noise, and assumed instrument properties on aperture diameter, solid angle, and pixel resolution. We hope future white-light coronagraphs will exhibit capabilities to measure electron density, temperature, and speed.

Nelson Reginald↗

High-Speed Edge-Detecting Line Scan Smart Camera

A high-speed edge-detecting line scan smart camera was developed. The camera is designed to operate as a component in a NASA Glenn Research Center developed inlet shock detection system. The inlet shock is detected by projecting a laser sheet through the airflow. The shock within the airflow is the densest part and refracts the laser sheet the most in its vicinity, leaving a dark spot or shadowgraph. These spots show up as a dip or negative peak within the pixel intensity profile of an image of the projected laser sheet. The smart camera acquires and processes in real-time the linear image containing the shock shadowgraph and outputting the shock location. Previously a high-speed camera and personal computer would perform the image capture and processing to determine the shock location. This innovation consists of a linear image sensor, analog signal processing circuit, and a digital circuit that provides a numerical digital output of the shock or negative edge location. The smart camera is capable of capturing and processing linear images at over 1,000 frames per second. The edges are identified as numeric pixel values within the linear array of pixels, and the edge location information can be sent out from the circuit in a variety of ways, such as by using a microcontroller and onboard or external digital interface to include serial data such as RS-232/485, USB, Ethernet, or CAN BUS; parallel digital data; or an analog signal. The smart camera system can be integrated into a small package with a relatively small number of parts, reducing size and increasing reliability over the previous imaging system..

Prokop, Norman F.↗

Optimizing view/illumination geometry for terrestrial features using Space Shuttle and aerial polarimetry

This paper describes to relationship of polarimetric observations from orbital and aerial platforms and the determination optimum sun-target-sensor geometry. Polarimetric observations were evaluated for feature discrimination. The Space Shuttle experiment was performed using two boresighted Hasselblad 70 mm cameras with identical settings with linear polarizing filters aligned orthogonally about the optic axis. The aerial experiment was performed using a single 35 mm Nikon FE2 and rotating the linear polarizing filter 90 deg to acquire both minimum and maximum photographs. Characteristic curves were created by covertype and waveband for both aerial and Space Shuttle imagery. Though significant differences existed between the two datasets, the observed polarimetric signatures were unique and separable.

Israel, Steven A.↗

Progress on the Development of a Step Height Sensor for the BOLT Flight Vehicle

This presentation will summarize progress on the development of a step height sensor for the BOLT flight vehicle. Two methods have been proposed to measure the step size in this effort.The first method involves the application of miniaturized camera embedded in the flight vehicle that views the step through a rearward-facing port (shown in Fig. 1a inset). The second method involves the application of a linear fiber optic array bundle to measure the intensity of light reflected back from the aft body step (concept shown in Fig. 1b). Preliminary testing with the miniaturized camera has been performed in the lab and shows that displacements of ≤10 μm can be measured using this method. Final testing with both methods will be performed on the test stand shown in Fig. 1a. This test stand will include a fine adjustment vertical translation stage that will be used to adjust the step height in steps of 1-2 μm. A high-magnification imaging system will also be used to verify the step height. The miniaturized camera and linear fiber optic array bundle will be mounted in one of several port holes with varying degrees of inclination relative to the top surface in the opposing aft-section slab. BOLT flight vehicle details and information on the steps can be found in Ref. [1].

BOLT↗

The Design of Optical Sensor for the Pinhole/Occulter Facility

Three optical sight sensor systems were designed, built and tested. Two optical lines of sight sensor system are capable of measuring the absolute pointing angle to the sun. The system is for use with the Pinhole/Occulter Facility (P/OF), a solar hard x ray experiment to be flown from Space Shuttle or Space Station. The sensor consists of a pinhole camera with two pairs of perpendicularly mounted linear photodiode arrays to detect the intensity distribution of the solar image produced by the pinhole, track and hold circuitry for data reduction, an analog to digital converter, and a microcomputer. The deflection of the image center is calculated from these data using an approximation for the solar image. A second system consists of a pinhole camera with a pair of perpendicularly mounted linear photodiode arrays, amplification circuitry, threshold detection circuitry, and a microcomputer board. The deflection of the image is calculated by knowing the position of each pixel of the photodiode array and merely counting the pixel numbers until threshold is surpassed. A third optical sensor system is capable of measuring the internal vibration of the P/OF between the mask and base. The system consists of a white light source, a mirror and a pair of perpendicularly mounted linear photodiode arrays to detect the intensity distribution of the solar image produced by the mirror, amplification circuitry, threshold detection circuitry, and a microcomputer board. The deflection of the image and hence the vibration of the structure is calculated by knowing the position of each pixel of the photodiode array and merely counting the pixel numbers until threshold is surpassed.

Greene, Michael E.↗