Search NASA⌕ Search

SEARCH · Search NASA

Results for “load changes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Predicting the Response of Electricity Load to Climate Change

Our purpose is to develop a methodology to quantify the impact of climate change on electric loads in the United States. We perform simple linear regression, assisted by geospatial smoothing, on paired temperature and load time-series to estimate the heating- and coolinginduced sensitivity to temperature across 300 transmission zones and 16 seasonal and diurnal time periods. The estimated load sensitivities can be coupled with climate scenarios to quantify the potential impact of climate change on load, with a primary application being long-term electricity scenarios. The method allows regional and seasonal differences in climate and load response to be reflected in the electricity scenarios. While the immediate product of this analysis was designed to mesh with the spatial and temporal resolution of a specific electricity model to enable climate change scenarios and analysis with that model, we also propose that the process could be applied for other models and purposes.

54 ENVIRONMENTAL SCIENCES↗

Plasma Ignition and Combustion Stabilization Technology to Improve Flexible Operation, Reliability and Economics of an Existing Coal-Fired Boiler

GE Steam Power, Inc. (GE) proposed to improve reliability, flexibility, and economics of an existing coal-fired power plant by applying a new advanced technology developed by GE, a plasma-assisted pulverized fuel firing system. The objective of this program is to demonstrate the achievement of lower load by improved flame stabilization and therefore lower operating costs in a full-scale field installation at coal-fired electric utility. GE’s Plasma Ignition and Combustion Stabilization System is designed to operate continuously to support low load operation. With the plasma on, the flame will be attached and stable, removing the firing system as a limitation to low load operation. In addition, GE’s exclusively from ABENZ company licensed AC based technology has a 90+% system efficiency compared to all other systems at which are DC and operate with ~75% efficiency. Plant operating costs are lowered by eliminating use of expensive support fuel as well as the ability to operate at lower loads. The utilities’ ability to better match the demand curve will result in significant savings. Maintenance is lower for an AC system than a DC system as it operates at lower current. This eliminates the need for a demineralized cooling water system and provides longer electrode life which translates into both material and labor savings. It is the objective of GE to not only demonstrate the additional low load achievable with a plasma system after best achievable tuning, sensor and software approach has been exhausted, but also the increased stability of the flame at all loads with plasma assistance as well as cost savings at all low loads using plasma instead of oil. Upon successful completion of this project, GE will have sufficient field experience to rapidly deploy the Plasma Technology. The project objectives were achieved through the implementation of plasma ignitor technology at PacifiCorp Hunter Station Unit 3. A plasma ignitor system was retrofitted on ten wall-fired burners, Mill 3-4 combustion system. The Plasma Ignitors installed at Hunter proved that this GE technology is a direct and complete replacement for the original oil ignitors. The Hunter Unit 3 burner management system allows the plasma system to be used in all applications that originally required oil to be burned. This includes any time the Mill 3-4 is started or stopped for any reason including boiler starts, load changes, and low load support.

01 COAL, LIGNITE, AND PEAT↗

Digital Single-Phase Power-Factor Controller

Digital circuit has faster response to load changes. Digital power-factor controller senses changing motor-load torques by sampling open-circuit voltage across gate-controlled silicon switch. Circuit responds more rapidly to hanging loads than analog power-factor controllers because no low-pass filter is in feedback loop.

Dabney, R. W.↗

Evaluation of Distributed Power Apportioning with Net Load Management Engine in Microgrids Using Power Hardware-in-the-Loop Simulation

This article presents the performance evaluation of ratio consensus-based distributed power apportioning engine along with centralized net load management (NLM) engine that ensures viable and stable operation of an islanded microgrid. Managing net load variability in a microgrid with high penetrations of uncertain renewable generation and ever-changing load demands is a crucial need in order to ensure viable and stable operation of the microgrid. Centralized “dispatch-rule”-based and/or multi-agent-based distributed control of distributed energy resources (DERs) in microgrid are well accepted for microgrid by adapting ANSI/ISA-95-based hierarchical control architecture. In the application where microgrid network has large geographical span with multiple DERs dispersed in the network, high penetration of uncertain renewable energy resources, and ever-changing load demands, a judicious selection of techniques/solutions for managing net-load resources for maintaining viability and stability is required. With this motivation, this article proposes a novel solution to mitigate the challenges by incorporating a mixed centralized NLM engine and distributed power apportioning control of DERs and loads. A power-hardware-in-the-loop (PHIL) -based experiment is conducted with the centralized NLM engine and the distributed power apportioning engine along with two commercial inverters. The experimental results validates the efficacy of the proposed method in ensuring viability and stability of a microgrid.

hardware-in-the-loop simulation↗

Grid and Wind Transient Ride Through Assessment of Type-5 Synchronous Wind Turbine

The integration of the inverter-based renewable energy resources is increasing and replacing conventional synchronous generators in the evolving bulk power system (BPS), impacting the system inertia along the way. Also, the limited over-current capability of power electronic converters continues to deteriorate the grid strength of the evolving power systems. Type-5 wind turbines have the potential to mitigate these problems because this configuration interfaces with the grid through a synchronous generator; hence, its operation and consequent grid impacts might mimic the conventional synchronous generator. The drivetrain of this type of turbines, however, is different from the more common Type-3 and Type-4 turbines. A hydraulic torque converter and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine drivetrain, to isolate the wind speed variations at the wind turbine rotor from the grid connected generator side. This supports the synchronous operation of the generator. However, high fidelity models of Type-5 wind turbine drivetrain including these core components are not openly and widely available for grid integration and transient stability studies. Moreover, Type-5 turbines are not commonly deployed and hence its power generation and frequency stability characteristics are not widely publicized. This hinders appropriate assessment of Type-5 wind power plant's contribution to bulk grid resilience. This work provides transient stability assessment of a standalone Type-5 wind turbine. Normal operation and grid transient studies are performed to see the step load change and wind speed disturbance impacts on the Type-5 drivetrain and generation dispatch. Preliminary results show that Type-5 wind turbines can support load changes of between 0.6 p.u to 1.15 p.u. Beyond this point, the synchronization of the generator starts to deviate from its set point.

17 - WIND ENERGY↗

Application of linear multiple model predictive control (MMPC) framework towards dynamic maximazation of oxygen yield in an elevated-pressure air separation unit

In a typical air separation unit (ASU) utilizing either a simple gaseous oxygen (GOX) cycle or a pumped liquid oxygen (PLOX) cycle, the flowrate of liquid nitrogen (LN2) stream connecting high-pressure and low-pressure ASU columns plays an important role in the total oxygen yield. It has been observed that this yield reaches a maximum at a certain optimal flowrate of LN2 stream. At nominal full-load operation, the flowrate of LN2 stream is maintained near this optimum value, whereas at part-load conditions this flowrate is typically modified in proportion with the load-change (oxygen demand) through a ratio/feed-forward controller. Due to nonlinearity in the entire ASU process, the ratio-modified LN2 flowrate does not guarantee an optimal oxygen yield at part-load conditions. This is further exacerbated when process disturbances in form of “cold-box” heat-leaks enter the system. To address this problem of dynamically maximizing the oxygen yield while the ASU undergoes a load-change and/or a process disturbance, a multiple model predictive control (MMPC) algorithm is proposed. This approach has been used in previous studies to handle large ramp-rates of oxygen demand posed by the gasifier in an IGCC plant. In this study, the proposed algorithm uses linear step-response “blackbox” models surrounding the operating points corresponding to maximum oxygen yield points at different loads. It has been shown that at any operating point of the ASU, the MMPC algorithm, through model-weight calculation based on plant measurements, naturally and continuously selects the dominant model(s) corresponding to the current plant state, while making control-move decisions that approach the maximum oxygen yield point. This dynamically facilitates less energy consumption in form of compressed feed-air compared to a simple ratio control during load-swings. In addition, since a linear optimization problem is solved at each time step, the approach involves much less computational cost compared to a firstprinciple based nonlinear MPC. Introduction

97 MATHEMATICS AND COMPUTING↗

Direct model reference adaptive control of robotic arms

The results of controlling A PUMA 560 Robotic Manipulator and the NASA shuttle Remote Manipulator System (RMS) using a Command Generator Tracker (CGT) based Model Reference Adaptive Controller (DMRAC) are presented. Initially, the DMRAC algorithm was run in simulation using a detailed dynamic model of the PUMA 560. The algorithm was tuned on the simulation and then used to control the manipulator using minimum jerk trajectories as the desired reference inputs. The ability to track a trajectory in the presence of load changes was also investigated in the simulation. Satisfactory performance was achieved in both simulation and on the actual robot. The obtained responses showed that the algorithm was robust in the presence of sudden load changes. Because these results indicate that the DMRAC algorithm can indeed be successfully applied to the control of robotic manipulators, additional testing was performed to validate the applicability of DMRAC to simulated dynamics of the shuttle RMS.

Kaufman, Howard↗

Nominal and adversarial synthetic PMU data for standard IEEE test systems

GridSTAGE (Spatio-Temporal Adversarial scenario GEneration) is a framework for the simulation of adversarial scenarios and the generation of multivariate spatio-temporal data in cyber-physical systems. GridSTAGE is developed based on Matlab and leverages Power System Toolbox (PST) where the evolution of the power network is governed by nonlinear differential equations. Using GridSTAGE, one can create several event scenarios that correspond to several operating states of the power network by enabling or disabling any of the following: faults, AGC control, PSS control, exciter control, load changes, generation changes, and different types of cyber-attacks. Standard IEEE bus system data is used to define the power system environment. GridSTAGE emulates the data from PMU and SCADA sensors. The rate of frequency and location of the sensors can be adjusted as well. Detailed instructions on generating data scenarios with different system topologies, attack characteristics, load characteristics, sensor configuration, control parameters are available in the Github repository - https://github.com/pnnl/GridSTAGE. There is no existing adversarial data-generation framework that can incorporate several attack characteristics and yield adversarial PMU data. The GridSTAGE framework currently supports simulation of False Data Injection attacks (such as a ramp, step, random, trapezoidal, multiplicative, replay, freezing) and Denial of Service attacks (such as time-delay, packet-loss) on PMU data. Furthermore, it supports generating spatio-temporal time-series data corresponding to several random load changes across the network or corresponding to several generation changes. A Koopman mode decomposition (KMD) based algorithm to detect and identify the false data attacks in real-time is proposed in https://ieeexplore.ieee.org/document/9303022. Machine learning-based predictive models are developed to capture the dynamics of the underlying power system with a high level of accuracy under various operating conditions for IEEE 68 bus system. The corresponding machine learning models are available at https://github.com/pnnl/grid_prediction.

99 GENERAL AND MISCELLANEOUS↗

Active Suspension Parameters Identification: An Algebraic Approach and its Application to Suspension Travel Control

The parameters of an active suspension need to be identified online, such that the suspension control system can be adapted to mechanical wear and load change. Recursive least squares and observer-based methods are frequently utilized to fulfill this purpose. However, they can yield slow parameter identification due to their asymptotic nature. We propose an algebraic identifier to estimate the parameters of an active suspension online, which does not maintain an asymptotic convergence phase. Simulation results demonstrate the effectiveness of the proposed algebraic approach.

Wang, Zejiang↗

Cooling Performance Testing of Attaway's Negative Pressure CDU

Attaway is a recently installed High-Performance Computing (HPC) machine at Sandia National Labs that is 70% water-cooled and 30% air-cooled. This machine, supplied by Penguin Computing, uses a novel new cooling system from Chilldyne that operates in a vacuum, preventing water leaks. If water-cooling is to fail, fans inside of each node will ramp up to do 100% of the cooling on Attaway. Various tests were completed on Attaway to determine the robustness of its cooling system as well as its ability to respond to sudden changes in states. These changes include an immediate change from an idle compute load to full load (Linpack) as well as running Linpack without any water cooling from Attaway's CDUs. It was discovered that Attaway could respond to sudden compute load changes very well, never throttling any nodes. When Linpack was run without water cooling, the system was able to operate for a short time before throttling happened.

42 ENGINEERING↗

Short-Term Load Forecasting-Based Automatic Distribution Network Reconfiguration

In a traditional dynamic network reconfiguration study, the optimal topology is determined at every scheduled time point by using the real load data measured at that time. The development of the load forecasting technique can provide an accurate prediction of the load power that will happen in a future time and provide more information about load changes. With the inclusion of load forecasting, the optimal topology can be determined based on the predicted load conditions during a longer time period instead of using a snapshot of the load at the time when the reconfiguration happens; thus, the distribution system operator can use this information to better operate the system reconfiguration and achieve optimal solutions. This paper proposes a short-term load forecasting approach to automatically reconfigure distribution systems in a dynamic and pre-event manner. Specifically, a short-term and high-resolution distribution system load forecasting approach is proposed with a forecaster based on support vector regression and parallel parameters optimization. The network reconfiguration problem is solved by using the forecasted load continuously to determine the optimal network topology with the minimum amount of loss at the future time. The simulation results validate and evaluate the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution System Segmented Model Simplification with Independent Dynamically Changing End-Use Loads

With more emerging technologies in power distribution systems, to support quasi-static time-series (QSTS) simulation over short time frames, accurately modeling the dynamic behavior of end-use load under various conditions is im- portant. However, time and cost can be a burden for the QSTS simulation of thousands of houses representing dynamic load behaviors on large distribution feeders. There are two main contributions of this paper in order to reduce the QSTS simulation complexity. First, the paper presents a method to stochasti- cally model the dynamic behavior of end-use load for QSTS simulations. Second, using the stochastically modeled load behavior as an input to a distribution sys- tem, and building on our previous QSTS simulation simplification/acceleration method that relies on uniform load behavior, this paper presents a segment substitution approach for the simplification of distribution system models with independent dynamically changing end-use loads. Our numerical results show that compared to GridLAB-D, a software tool that simulates end-use load be- havior through physical models, the proposed stochastic modeling approach achieved an 89.3% simulation time reduction for end-use loads, while accurately capturing the temporally changing total load behavior. Moreover, the QSTS simulation of a large test distribution system through OpenDSS showed that the proposed simplification method decreased the feeder simulation time by a factor of three at less than 0.3% voltage error. Compared to our previous method with independent dynamic loads, the voltage error is reduced by a factor of four.

Power distribution system modeling, stochastic pro↗

Distribution Integration Solution Cost Options (DISCO) [Slides]

DISCO is a Python-based NREL software tool for conducting scalable, repeatable distribution analyses. Although DISCO was originally developed to support photovoltaic impact analyses, it can also be used to understand the impact of other distributed energy resources and load changes on distribution systems. This presentation took place on April 9, 2024, and included NREL power grid researchers Sherin Ann Abraham and Shibani Ghosh.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Creating an Advanced Sensor Network to calculate real-time, mass-weighted flue gas composition and air heater leakage of a coal-fired utility boiler under dynamic operating conditions

Utilization of renewable energy sources to minimize the environmental impact of energy production has changed the way utility boilers operate, requiring frequent load cycling between full load and partial loads as low as 30%. Dynamic operation of coal-fired utility boilers significantly reduces boiler efficiency when compared to steady state at full load. Data-driven plant optimization has shown success with coal-fired utility boilers under dynamic operating conditions. The purpose of this work was to create an Advanced Sensor Network (ASN) to provide more extensive real-time data to inform dynamic plant optimization of Net Unit Heat Rate (NUHR). The ASN consists of gas sampling grids in the convective pass of the boiler and downstream of the air heater. These sampling grids allow for quantification of spatial variation of flue gas within the boiler and calculation of mass-weighted composition of flue gas through the combination of composition, velocity, and temperature measurements. The comparison of O 2 between the inlet and outlet of the air heater is used to calculate air leakage in real time. Flue gas composition and air heater leakage are both important factors in boiler efficiency and NUHR. Further, the results of this work support the value of mass-weighted averages for determining flue gas composition accurately. The measurements from the ASN show increased composition stratification during dynamic operation, with an average standard deviation 38% higher than observed during steady-state operation. Air heater leakage was also observed to increase from 2.8% to 5.1% following a load change. Prior to the installation of the ASN, these data would not have been available for dynamic control. These real-time data will be leveraged to calculate and optimize for NUHR during dynamic operation in future work.

42 ENGINEERING↗

Simulator Tests Controller Performance

Compact servosystem applies simulated dynamic loads, enabling realistic appraisal of motor and its control system without inconvenience of attaching real load. System simulates moments of inertia, rotational vibrations, changing load torques, and other characteristics of large or complex loads, without loads themselves and without awkwardness (and inaccuracy) of gravity-compensating devices used with such loads.

Lembeck, M. F.↗

Monitoring Loads In Fiber-Reinforced Composite Materials

In new method of determining load on specimen, direction of stress wave propagation measured by array of acoustic sensors attached to specimen. Responses of sensors analyzed by strain-energy-density calculations to calculate load. Change in anisotropy of elasticity caused by applied load and corresponding induced strain. Is means to monitor applied load corresponding to measurable shift in direction of propagation of stress wave. Monitoring device based on this method made integral part of airframe in which unidirectional section of structure, such as spar cap or longeron, carries primary load.

Prosser, William H.↗