Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

ToF-SIMS spectral analysis of pristine and neutron irradiated single crystal tungsten

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many promising features in studying materials including high spatial resolution and high mass accuracy of elements, molecules, and isotopes. Its ability to resolve isotopes is especially attractive in studying transmutation products of single crystal tungsten (SCW) post neutron irradiation. Tungsten (W) is a contender of plasma facing materials (PFMs) due to its high thermal and radiological stability. PFMs to be used in the construction of fusion vessels are subject to high temperature and neutron irradiation, resulting in changes to materials including transmutation, which ultimately impact material mechanical and thermal properties. We used IONTOF TOF.SIMS V instrument equipped with a 30 keV Bi 3 + primary ion beam to study pristine SCW and irradiated SCW speciemens. Scanning electron microscope coupled with focused ion beam (SEM-FIB) was used to reduce the dosage of neutron irradiated tungsten and prepare for specimens for SIMS analysis. Static ToF-SIMS spectra were obtained, and transmutation product peak identification was presented in this work. Identified molecules and molecular fragments were compared against isotope theoretical mass to charge ratios of tungsten, rhenium, osmium, and other relevant products. Our results show that ToF-SIMS provides a viable means to study transmutation products of W post neutron irradiation. Such applications are suitable to investigate transmutation effects on materials that are being considered and developed for fusion pilot plants.

36 MATERIALS SCIENCE↗

Studying microbially induced corrosion on glass using ToF-SIMS

Microbially induced corrosion (MIC) is an emerging topic that has huge environmental impacts, such as long-term evaluation of microbial interactions with radioactive waste glass, environmental cleanup and disposal of radioactive material, and weathering effects of microbes. Time-of-flight secondary ion mass spectrometry (ToF-SIMS), a powerful mass spectral imaging technique with high surface sensitivity, mass resolution, and mass accuracy, can be used to study biofilm effects on different substrates. Understanding how to prepare biofilms on MIC susceptible substrates is critical for proper analysis via ToF-SIMS. We present here a step-by-step protocol for preparing bacterial biofilms for ToF-SIMS analysis, comparing three biofilm preparation techniques: no desalination, centrifugal spinning (CS), and water submersion (WS). Comparisons of two desalinating methods, CS and WS, show a decrease in the media peaks up to 99% using CS and 55% using WS, respectively. Proper desalination methods also can increase biological signals by over four times for fatty acids using WS, for example. ToF-SIMS spectral results show chemical compositional changes of the glass exposed in a Paenibacillus polymyxa SCE2 biofilm, indicating its capability to probe microbiologically induced corrosion of solid surfaces. This represents the proper desalination technique to use without significantly altering biofilm structure and substrate for ToF-SIMS analysis. ToF-SIMS spectral results showed chemical compositional changes of the glass exposed by a Paenibacillus bacterial biofilm over 3-month inoculation. Finally, possible MIC products include various phosphate phase molecules not observed in any control samples with the highest percent increases when experimental samples were compared with biofilm control samples.

36 MATERIALS SCIENCE↗

Identification of Unique Fragmentation Patterns of Fentanyl Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry

The opioid crisis in the United States is being fueled by the rapid emergence of new fentanyl analogs and precursors that can elude traditional library-based screening methods, which require data from known reference compounds. Since reference compounds are unavailable for new fentanyl analogs, we examined if fentanyls (fentanyl + fentanyl analogs) could be identified in a reference-free manner using a combination of electrospray ionization (ESI), high-resolution ion mobility (IM) spectrometry, high-resolution mass spectrometry (MS), and higher-energy collision-induced dissociation (MS/MS). We analyzed a mixture containing nine fentanyls and W-15 (a structurally similar molecule) and found that the protonated forms of all fentanyls uniquely exhibited two baseline separated IM distributions that produced different MS/MS patterns. Upon fragmentation, both IM distributions of all fentanyls produced two high intensity fragments resulting from amine site cleavages. The higher mobility distributions of all fentanyls also produced several low intensity fragments, but surprisingly, these same fragments exhibited much greater intensities in the lower mobility distributions. This observation demonstrates that many fragments of fentanyls predominantly originate from one of two different gas-phase structures (suggestive of protomers). Furthermore, increasing the water concentration in the ESI solution increased the intensity of the lower mobility distribution relative to the higher mobility distribution, which further supports that fentanyls exist as two gas-phase protomers. In conclusion, our new observations on the IM and MS/MS properties of fentanyls can be exploited to positively identify them as fentanyls without requiring reference libraries and will hopefully assist first responders and law enforcement in combating new and emerging fentanyls.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating the Gas-Phase Behavior of Nitazene Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry

2-benzylbenzimidazoles, or “nitazenes”, are a class of novel synthetic opioids (NSOs) that are increasingly being detected alongside fentanyl analogs and other opioids in drug overdose cases. Nitazenes can be 20x more potent than fentanyl but are not routinely tested for during postmortem or clinical toxicology drug screens; thus, their prevalence in drug overdose cases may be under-reported. Traditional analytical workflows utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS) often require additional confirmation with authentic reference standards to identify a novel nitazene. However, additional analytical measurements with ion mobility spectrometry (IMS) may provide a path towards reference-free identification, which would greatly accelerate NSO identification rates in toxicology labs. Presented here are the first IMS and collision cross section (CCS) measurements on a set of fourteen nitazene analogs using a Structures for Lossless Ion Manipulations (SLIM)-Orbitrap MS. All nitazenes exhibited two high intensity baseline-separated IMS distributions, which fentanyls and other drug and drug-like compounds also exhibit. Incorporating water into the electrospray ionization (ESI) solution caused the intensities of the higher mobility IMS distributions to increase the intensities of the lower mobility IMS distributions to decrease. Nitazenes lacking a nitro group at the R1 position exhibited the greatest shifts in signal intensities due to water. Furthermore, IMS-MS/MS experiments showed that the higher mobility IMS distributions of all nitazenes produced fragment ions with m/z 72, 100, and other low intensity fragments while the lower mobility IMS distributions only produced fragment ions with m/z 72 and 100. The IMS, solvent, and fragmentation studies provide experimental evidence that nitazenes potentially exhibit three gas-phase protomers. In conclusion, the cyclic IMS capability of SLIM was also employed to partially resolve four sets of structurally similar nitazene isomers (e.g., protonitazene/isotonitazene, butonitazene/isobutonitazene/secbutonitazene), showcasing the potential of using high-resolution IMS separations in MS-based workflows for reference-free identification of emerging nitazenes and other NSOs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Untargeted Exometabolomics Provides a Powerful Approach to Investigate Biogeochemical Hotspots with Vegetation and Polygon Type in Arctic Tundra Soils

Rising temperatures in the Arctic have led to the thawing of tundra soils, which is rapidly changing terrain, hydrology, and plant and microbial communities, causing hotspots of biogeochemical activity across the landscape. Despite this, little is known about how nutrient-rich low molecular weight dissolved organic matter (LMW DOM) varies within and across tundra ecosystems. Using a high-resolution nano-liquid chromatography-mass spectrometry (LC/MS) approach, we characterized the composition and availability of LMW DOM from high-centered polygons (HCP) and low-centered polygons (LCP) with Eriophorum angustifolium or Carex aquatilis as the dominant vegetation. Over 3000 unique features (i.e., discrete mass/charge ions) were detected; 521 were identified as differentially abundant between polygonal types and 217 were putatively annotated using high mass accuracy MS data. While polygon type was a strong predictor of LMW DOM composition and availability, vegetation and soil depth were also important drivers. Extensive evidence was found for enhanced microbial processing at the LCP sites, which were dominated by Carex plant species. We detected significant differences between polygon types with varying aboveground landscape features or properties, and hotspots of biogeochemical activity, indicating LMW DOM, as quantified by untargeted exometabolomics, provides a window into the dynamic complex interactions between landscape topography, vegetation, and organic matter cycling in Arctic polygonal tundra soils.

58 GEOSCIENCES↗

Angles-Only Robust Trajectory Optimization for NRHO Rendezvous

This study demonstrates a robust trajectory optimization approach for rendezvous and proximity operations with angles-only navigation measurements. Often, sensors that directly measure relative range and velocity require communication or coordination between the chaser and target vehicle and can have limiting pointing accuracy, mass, or power requirements compared to angle measurement sensors. Thus, the capability to perform a rendezvous with only angle measurements can be advantageous for vehicle design and to improve robustness to failures. However, the well studied limitation of angles-only navigation in measuring range results in large uncertainties in the navigation system that must be reduced with chaser vehicle thrust maneuvers to induce observability in range for the navigation filter. This analysis presents a trajectory optimization problem for a lunar ascent rendezvous during a crewed lunar mission in a Near-Rectilinear Halo Orbit (NRHO) that is limited to only angle measurements. The objective of this study is to show that an angles-only rendezvous is feasible in an NRHO and to present the sensitivity to an assortment of constraints generated from a systematic optimization process using linear covariance analysis and particle swarm optimization. Linearized NRHO dynamics and linearized relative targeting are applied to use linear covariance analysis to determine the expected delta-v and trajectory dispersions due to initial state uncertainty, sensor errors, maneuver execution errors, and unmodeled dynamics. The delta-v and trajectory dispersions are passed into a particle swarm optimization algorithm to find the optimized maneuver profile that minimizes fuel use while satisfying constraints such as free drift and underburn to 3-sigma certainty. The trajectory constraints including time available, desired final uncertainty, and initial uncertainty are varied to ascertain sensitivity and desirable engineering trades.

Linear Covariance Analysis↗

High accuracy fuel flowmeter. Phase 2C and 3: The mass flowrate calibration of high accuracy fuel flowmeters

A facility for the precise calibration of mass fuel flowmeters and turbine flowmeters located at AMETEK Aerospace Products Inc., Wilmington, Massachusetts is described. This facility is referred to as the Test and Calibration System (TACS). It is believed to be the most accurate test facility available for the calibration of jet engine fuel density measurement. The product of the volumetric flow rate measurement and the density measurement, results in a true mass flow rate determination. A dual-turbine flowmeter was designed during this program. The dual-turbine flowmeter was calibrated on the TACS to show the characteristics of this type of flowmeter. An angular momentum flowmeter was also calibrated on the TACS to demonstrate the accuracy of a true mass flowmeter having a 'state-of-the-art' design accuracy.

Craft, D. William↗

Dependence of Dynamic Modeling Accuracy on Sensor Measurements, Mass Properties, and Aircraft Geometry

The NASA Generic Transport Model (GTM) nonlinear simulation was used to investigate the effects of errors in sensor measurements, mass properties, and aircraft geometry on the accuracy of identified parameters in mathematical models describing the flight dynamics and determined from flight data. Measurements from a typical flight condition and system identification maneuver were systematically and progressively deteriorated by introducing noise, resolution errors, and bias errors. The data were then used to estimate nondimensional stability and control derivatives within a Monte Carlo simulation. Based on these results, recommendations are provided for maximum allowable errors in sensor measurements, mass properties, and aircraft geometry to achieve desired levels of dynamic modeling accuracy. Results using additional flight conditions and parameter estimation methods, as well as a nonlinear flight simulation of the General Dynamics F-16 aircraft, were compared with these recommendations

Grauer, Jared A.↗

Accuracy of estimating the masses of Phobos and Deimos from multiple Viking orbiter encounters

The problem was investigated of estimating the masses of Phobos and Deimos from Doppler and onboard optical measurements during the Viking extended mission. A Kalman filter was used to analyze the effects of gravitational uncertainties and nongravitational accelerations. These accelerations destroy the dynamical integrity of the orbit, and multibatch or limited memory filtering is preferred to single batch processing. Optical tracking is essential to improve the relative orbit geometry. The masses can be determined to about 10% and 25% respectively for Phobos and Deimos, assuming satellite densities of about 3 gr/cu cm.

Tolson, R. H.↗

Accuracy of estimating the masses of Phobos and Deimos from multiple Viking orbiter encounters

This paper addresses the problem of estimating the masses of Phobos and Deimos from Doppler and onboard optical measurements during the Viking extended mission. A Kalman filter is used to analyze the effects of gravitational uncertainties and nongravitational accelerations. These accelerations destroy the dynamical integrity of the orbit and multi-batch or limited memory filtering is preferred to single batch processing. Optical tracking is essential to improve the relative orbit geometry. The masses can be determined to about 10% and 25% respectively for Phobos and Deimos, assuming satellite densities of about 3 g per cu cm.

Tolson, R. H.↗

Direct detection of dark matter substructure in strong lens images with convolutional neural networks

Strong gravitational lensing is a potential way of uncovering the nature of dark matter, by finding perturbations to images that cannot be accounted for well by modeling the lens galaxy without additional structure, be it subhalos (smaller halos within the smooth lens) or line-of-sight (LOS) halos. Here, we introduce results attempting to infer the presence of substructure from images without requiring an intermediate step in which a smooth model has to be subtracted, using a simple convolutional neural network (CNN). We find that the network is only able to infer the presence of subhalos with greater than 75% accuracy when they have masses of greater than or equal to 5 × 10 9 M ⊙ if they lie within the main lens galaxy. Since less massive foreground LOS halos can have the same effect as higher-mass subhalos, the CNN can probe lower masses in the halo mass function. The accuracy does not improve significantly if we add a population of less massive subhalos. With the expectation of experiments such as Hubble Space Telescope and Euclid yielding thousands of high-quality strong lensing images in the next years, having a way of analyzing images quickly to identify candidates that merit further analysis to determine individual subhalo properties while preventing extensive resources being used for images that would yield null detections could be very useful. By understanding the sensitivity as a function of substructure mass, nondetections could be combined with the information from images with substructure to constrain the cold dark matter scenario, in particular if the sensitivity can be pushed to lower masses.

79 ASTRONOMY AND ASTROPHYSICS↗

Experiment D003: Mass determination

The accuracy of a direct contact method with a spacecraft to determine the mass of an orbiting object was studied. The precedure involved acceleration of the Gemini Agena target vehicle by the use of the Gemini 9 spacecraft propulsion system. The target vehicle mass was calculated from the resultant acceleration, updated Gemini spacecraft mass, and calibrated thrust levels of the air-firing thrusters of the orbital attitude and maneuver system of the Gemini spacecraft.

Hamborsky, R. J.↗

Evaluation of Clouds and the Earth's Radiant Energy System (CERES) Scanner Pointing Accuracy using a Coastline Detection System

Clouds and the Earth's Radiant Energy System (CERES) is a National Aeronautics and Space Administration (NASA) investigation to examine the role of clouds in the radiative energy flow through the Earth-atmosphere system. The first CERES scanning radiometer was launched on November 27, 1997 into a 35 inclination, 350 km altitude orbit, on the Tropical Rainfall Measuring Mission (TRMM) spacecraft. The CERES instrument consists of a three channel scanning broadband radiometer. The spectral bands measure shortwave (0.3 - 5 microns), window (8 - 12 microns), and total (0.3 - 100 microns) radiation reflected or emitted from the Earth-atmosphere system. Each Earth viewing measurement is geolocated to the Earth fixed coordinate system using satellite ephemeris, Earth rotation and geoid, and instrument pointing data. The interactive CERES coastline detection system is used to assess the accuracy of the CERES geolocation process. By analyzing radiative flux gradients at the boundaries of ocean and land masses, the accuracy of the scanner measurement locations may be derived for the CERES/TRMM instrument/satellite system. The resulting CERES measurement location errors are within 10% of the nadir footprint size. Precise pointing knowledge of the Visible and Infrared Scanner (VIRS) is required for convolution of cloud properties onto the CERES footprint; initial VIRS coastline results are included.

Currey, Chris↗

A Dual-Gated Structures for Lossless Ion Manipulations-Ion Mobility Orbitrap Mass Spectrometry Platform for Combined Ultra-High-Resolution Molecular Analysis

High-resolution ion mobility spectrometry-mass spectrometry (HR-IMS-MS) instruments have enormously advanced the ability to characterize complex biological mixtures. Unfortunately, HR-IMS and HR-MS measurements are typically performed independently due to mismatches in analysis time scales. Here we overcome this limitation by using a dual-gated ion injection approach to couple an 11-meter path length structures for lossless ion manipulations (SLIM) module to a Q-Exactive Plus Orbitrap MS. The dual-gate setup was implemented by placing one ion gate before the SLIM module and a second ion gate after. The dual-gated ion injection approach allowed the new SLIM-Orbitrap platform to simultaneously perform an 11-meter SLIM separation, Orbitrap mass analysis using the highest selectable mass resolution setting (up to 140k), and high-energy collision induced dissociation (HCD) in ~25 minutes over an $m/z$ range of ~1500 amu. The SLIM-Orbitrap was initially characterized using a mixture of standard phosphazene cations and demonstrated an average SLIM CCS resolving power (Rp CCS ) of ~218 and SLIM peak capacity of ~156 while simultaneously obtaining high mass resolutions. SLIM-Orbitrap analysis with fragmentation was then performed on mixtures of standard peptides and two reverse peptides (SDGRG 1+ , GRGDS 1+ , Rp CCS = 305) to demonstrate the utility of combined HR-IMS-MS/MS measurements for peptide identification. Our new HR-IMS-MS/MS capability was further demonstrated by analyzing a complex lipid mixture and showcasing SLIM separations on isobaric lipids. In conclusion, this new SLIM-Orbitrap platform demonstrates a critical new capability for proteomics and lipidomics applications, and the high-resolution multimodal data obtainable with this system establishes the foundation for reference-free identification of unknown ion structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TESS Discoveries

TESS discoveries have already become fruitful targets for HST follow up, and this will undoubtedly continue through the JWST era. In addition to providing targets for atmospheric characterization, TESS' Level One Science Requirement is to measure masses for 50 transiting planets smaller than 4 Earth radii. A full suite of ground based facilities will be working together to optimize the TESS science yield. Somewhat surprisingly though, no study has quantified the accuracy of mass constraints required to yield robust atmospheric properties of small planets. Previous work showed that the mass of a transiting exoplanet could be inferred from its transmission spectrum alone. The method leverages the effect of the planet's surface gravity on the atmospheric scale height, which in turn influences the transmission spectrum. However, significant degeneracies exist between transmission spectra of planets with different masses and compositions, making difficult to unambiguously determine the planet's mass and composition in many cases. I will present the first quantitative answer to this pressing question. Our analysis places definitive limits on how accurate mass constraints need to be in order to unambiguously determine atmospheric composition for a diverse array of planets ranging from terrestrial-size (TRAPPIST-1-like) to mini-Neptunes and hot Jupiters. These results broadly impact the community of scientists working on exoplanets -- from the full breadth of ground based observers conducting TESS follow-up, to those studying planet populations, and finally to those planning atmospheric investigations. This is particularly timely as the STScI Director charged the HST-TESS Advisory committee to report to the Space Telescope Users Committee on how HST can best support follow-up observations of TESS exoplanet discoveries. The community needs to determine optimal strategies for maximizing the rapid scientific return from TESS targets.

Batalha, Natasha E.↗

Dynamic Modeling Accuracy Dependence on Errors in Sensor Measurements, Mass Properties, and Aircraft Geometry

A nonlinear simulation of the NASA Generic Transport Model was used to investigate the effects of errors in sensor measurements, mass properties, and aircraft geometry on the accuracy of dynamic models identified from flight data. Measurements from a typical system identification maneuver were systematically and progressively deteriorated and then used to estimate stability and control derivatives within a Monte Carlo analysis. Based on the results, recommendations were provided for maximum allowable errors in sensor measurements, mass properties, and aircraft geometry to achieve desired levels of dynamic modeling accuracy. Results using other flight conditions, parameter estimation methods, and a full-scale F-16 nonlinear aircraft simulation were compared with these recommendations.

Grauer, Jared A.↗

SIM Planetquest Science and Technology: A Status Report

Optical interferometry will open new vistas for astronomy over the next decade. The Space Interferometry Mission (SIM-PlanetQuest), operating unfettered by the Earth's atmosphere, will offer unprecedented astrometric precision that promises the discovery of Earth-analog extra-solar planets as well as a wealth of important astrophysics. Results from SIM will permit the determination of stellar masses to accuracies of 2% or better for objects ranging from brown dwarfs through main sequence stars to evolved white dwarfs, neutron stars, and black holes. Studies of star clusters will yield age determinations and internal dynamics. Microlensing measurements will present the mass spectrum of the Milky Way internal to the Sun while proper motion surveys will show the Sun's orbital radius and speed. Studies of the Galaxy's halo component and companion dwarf galaxies permit the determination of the Milky Way's mass distribution, including its Dark Matter component and the mass distribution and Dark Matter component of the Local Group. Cosmology benefits from precision (1-2%) determination of distances to Cepheid and RR Lyrae standard candles. The emission mechanism of supermassive black holes will be investigated. Finally, radio and optical celestial reference frames will be tied together by an improvement of two orders of magnitude. Optical interferometers present severe technological challenges. The Jet Propulsion Laboratory, with the support of Lockheed Martin Advanced Technology Center (LM ATC) and Northrop Grumman Space Technology (NGST), has addressed these challenges with a technology development program that is now complete. The requirements for SIM have been satisfied, based on outside peer review, using a series of laboratory tests and appropriate computer simulations: laser metrology systems perform with 10 picometer precision; mechanical vibrations have been controlled to nanometers, demonstrating orders of magnitude disturbance rejection; and knowledge of component positions throughout the whole test assembly has been demonstrated to the required picometer level. Technology transfer to the SIM flight team is now well along.

astrometry↗

Recent Advancements in Electrical Capacitance Mass Gauging for Cryogenic PropellantTanks

The current lack of unsettled mass gauging is a key roadblock for many space activities, such as orbital refueling, missions to the Moon and Mars, and nuclear thermal and nuclear electric propulsion technologies. Liquid can form any one of an infinite number of configurations in microgravity, such as floating in globs or accumulating on tank surfaces in discontiguous volumes, or both. Capacitive sensing requires no moving parts and dissipates close to zero heat, making it an ideal candidate for cryogenic fluid mass gauging in settled and unsettled configurations. Capacitive sensing has a history of proven use in space propellant tanks, including tanks on the space shuttle, Saturn V, and the Apollo Lunar Excursion Module. Modern capacitive sensor technology allows using the entire tank as the capacitor volume by placing electrodes on the tank walls and propellant management surfaces. Capacitance is directly related to density, and therefore to mass for fixed volumes. In this presentation, we discuss the concepts behind whole-tank capacitance mass gauging and associated engineering challenges. We describe recent efforts to develop a micro-g unsettled cryogenic mass gauge using whole-tank capacitance sensing, including the development of test beds, electronics, and algorithms. We describe several mathematical processing techniques, including empirical-based averaging, electrical capacitance volume tomography, and spatial regularization. A modeling study, performed using settled configurations in gravity and no gravity, and with a set of 100 random fluid configurations, has indicated that spatial regularization, in which capacitance measurements are weighted to account for non-uniform electric fields, yields a mass fraction accuracy of 8% for any fluid configuration. Such a sensor is expected to operate in real time with a sampling frequency of at least 1 kHz.

cryogenic↗