Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass spectrometry analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Applications of Alternate Actinide Calibration on Inductively Coupled Plasma Mass Spectrometry Analysis of H-Canyon Highly Enriched Uranium Legacy Material at the Savannah River Site

Alternate Actinide Calibration is beneficial for calibration using lower activity standards • ICP-MS and ICP-OES are valid complementary methods for U analysis • Recently procured Agilent 8900 ICP-QQQ-MS in radiological buffer area –installation in progress • Helium (kinetic energy discrimination) can be used for reducing polyatomic interferences • Installing hydrogen and oxygen (reaction gases) on 8900 ICP-MS systems to improve LODs of several challenging analytes

Jones, Mark A.↗

Analysis of the thermal reaction products of para polyphenylene by combined gas chromatography-mass spectrometry

Analysis of the volatiles and sublimate produced when para-polyphenylene is pyrolyzed to constant weight under vacuum in the temperature range from 380 to 1000 C indicates that the polymer undergoes thermal degradation in two stages. The first stage involved dehydrohalogenation, which is essentially a curing reaction that produces crosslinking between polyphenylene chains resulting from the loss of chlorine from the polymer in the form of hydrogen chloride. The second stage of the thermal degradation is dehydrogenation because hydrogen is the major volatile species. Increasing amounts of polycyclic aromatic hydrocarbons (phenanthrene and 9, 10 benzphenanthrene) in the sublimate, concomitant with increasing C/H ratios of the polymeric residue with pyrolysis temperature, is consistent with the buildup of polynuclear structures in the polymer matrix.

Fewell, L. L.↗

Tandem pyrolysis evolved gas–gas chromatography–mass spectrometry

Analysis of byproducts from thermal degradation of polymer materials provides a wealth of information about a materials’ composition, thermal stability, degradation mechanisms, and kinetics. However, regardless of the instrumentation used, only limited information is obtainable from a single experiment. Microfurnace technology, when interfaced to a gas chromatography-mass spectrometry (GC-MS), can be used to obtain both thermal and chemical information via evolved gas analysis-MS (EGA-MS) and GC-MS analysis modes. While both EGA-MS and Py-GC-MS are valuable when characterizing polymer materials, at least two experiments on distinct samples are required, which can be a liability for clear interpretation of results from inhomogeneous samples. Here, we seek to overcome this limitation by combining EGA-MS and Py-GC-MS modes in a single experimental setup. Further, this was done by developing new gas line modifications to allow for tandem Pyrolysis Evolved Gas-Gas Chromatography-Mass Spectrometry (Py/EG-GC-MS) analysis. Verification of Py/EG-GC-MS analysis was performed using a polystyrene standard. Results demonstrate successful Py/EG-GC-MS analysis for the first-time showing the potential of these modifications for application in areas where sample is limited or direct correlation of products to the thermal profile is desirable such as in forensics or product-specific kinetics.

36 MATERIALS SCIENCE↗

SPE-CZE-MS Quantifies Zeptomole Amounts of Phosphorylated Peptides

Capillary zone electrophoresis (CZE) is gaining attention in the field of single-cell proteomics for its ultralow-flow and high-resolution separation abilities. Even more sample-limited yet rich in biological information are phosphoproteomics experiments, as the phosphoproteome composes only a fraction of the whole cellular proteome. Rapid analysis, high sensitivity, and maximization of sample utilization are paramount for single-cell analysis. Some challenges of coupling CZE analysis with mass spectrometry analysis (MS) of complex mixtures include 1. sensitivity due to volume loading limitations of CZE and 2. incompatibility of MS duty cycles with electropherographic time scales. Here, we address these two challenges as applied to singlecell- equivalent phosphoproteomics experiments by interfacing a microchip-based CZE device integrated with a solid-phaseextraction (SPE) bed with the Orbitrap Astral mass spectrometer. Using 225 phosphorylated peptide standards and phosphorylated peptide-enriched mouse brain tissue, we investigate microchip-based SPE-CZE functionality, quantitative performance, and complementarity to nano-LC-MS (nLC-MS) analysis. We highlight unique SPE-CZE separation mechanisms that can empower fitfor- purpose applications in single-cell-equivalent phosphoproteomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface Oxygen Depletion of Layered Transition Metal Oxides in Li-Ion Batteries Studied by Operando Ambient Pressure X-ray Photoelectron Spectroscopy

A new operando spectro-electrochemical setup was developed to study oxygen depletion from the surface of layered transition metal oxide particles at high degrees of delithiation. An NCM111 working electrode was paired with a chemically delithiated LiFePO 4 counter electrode in a fuel cell-inspired membrane electrode assembly (MEA). A propylene carbonate-soaked Li-ion conducting ionomer served as an electrolyte, providing both good electrochemical performance and direct probing of the NCM111 particles during cycling by ambient pressure X-ray photoelectron spectroscopy. The irreversible emergence of an oxygen-depleted phase in the O 1s spectra of the layered oxide particles was observed upon the first delithiation to high state-of-charge, which is in excellent agreement with oxygen release analysis via mass spectrometry analysis of such MEAs. By comparing the metal oxide-based O 1s spectral features to the Ni 2p 3/2 intensity, we can calculate the transition metal-to-oxygen ratio of the metal oxide close to the particle surface, which shows good agreement with the formation of a spinel-like stoichiometry as an oxygen-depleted phase. This new setup enables a deeper understanding of interfacial changes of layered oxide-based cathode active materials for Li-ion batteries upon cycling.

25 ENERGY STORAGE↗

Biological particle analysis by mass spectrometry

An instrument that analyzes the chemical composition of biological particles in aerosol or hydrosol form was developed. Efforts were directed toward the acquisition of mass spectra from aerosols of biomolecules and bacteria. The filament ion source was installed on the particle analysis by mass spectrometry system. Modifications of the vacuum system improved the sensitivity of the mass spectrometer. After the modifications were incorporated, detailed mass spectra of simple compounds from the three major classes of biomolecules, proteins, nucleic acids, and carbohydrates were obtained. A method of generating bacterial aerosols was developed. The aerosols generated were collected and examined in the scanning electron microscope to insure that the bacteria delivered to the mass spectrometer were intact and free from debris.

Vilker, V. L.↗

“Did you eat a MOLEcule today?” An Interactive Demonstration of Molecular Weight with Real-Time Breath Analysis Using Mass Spectrometry for All Ages

Although mass spectrometry is a widely used analytical tool, age-appropriate, interactive outreach activities for laboratory visitors, especially children, are lacking. Furthermore, the presented interactive demonstration, “Did you eat a MOLEcule today?”, introduces all ages to molecular weight concepts and mass spectrometry in a research laboratory, while connecting the concepts to real-world applications. Through real-time breath analysis, participants explore the concepts of molecular weight, electrostatic field manipulation of charged molecules, and analyte identification by mass analysis. This module is rapid and highly adaptable for outreach activities but also includes age- or classroom-appropriate variations to decrease or increase difficulty levels. The presented interactive demonstration has repeatedly been implemented, with over 2300 participants during six annual “Take Our Daughters & Sons to Work Day” and two corporate “Family Day” outreach activities, successfully engaging, exciting, and educating both kids and parents.

36 MATERIALS SCIENCE↗

Design and Evaluation of a Tethered, Open Port Sampling Interface for Liquid Extraction-Mass Spectrometry Chemical Analysis

Presented in this work is a tethered, liquid-extraction-sampling interface designed for the mass spectrometric surface sampling/analysis of 3D objects. The tethered, open port sampling interface (TOPSI) incorporates a vacuum line between the sampling probe and ionization source, which enables the ability for an extended, tethered sample transfer line. Herein, several designs of the hand-held TOPSI are presented and evaluated on the basis of the analytical metrics of analyte transport time, peak width, and analyte sensitivity. The best analytical metrics were obtained with capillary flow resistances arranged in a particular order and the vacuum region set at 6.2 kPa. This TOPSI design incorporated a transfer capillary 1 m in length, while retaining a fast analyte transport time (12 s), short signal peak width (5 s baseline-to-baseline), and high analyte signal at 90% of that obtained with a regular open port sampling interface (OPSI). The hand-held TOPSI was demonstrated for the characterization of extracted small molecules and metabolites from the surface of mint and rosemary leaves.

47 OTHER INSTRUMENTATION↗

Nanomechanical sampling of material for nanoscale mass spectrometry chemical analysis

The ability to spatially resolve the chemical distribution of compounds on a surface is important in many applications ranging from biological to material science. To this extent, we have recently introduced a hybrid atomic force microscopy (AFM)-mass spectrometry (MS) system for direct thermal desorption and pyrolysis of material with nanoscale chemical resolution. However, spatially resolved direct surface heating using local thermal desorption becomes challenging on material surfaces with low melting points, because the material will undergo a melting phase transition due to heat dissipation prior to onset of thermal desorption. Therefore, here we developed an approach using mechanical sampling and collection of surface materials on an AFM cantilever probe tip for real-time analysis directly from the AFM tip. This approach allows for material to be concentrated directly onto the probe for subsequent MS analysis. We evaluate the performance metrics of the technique and demonstrate localized MS sampling from a candelilla wax matrix containing UV stabilizers avobenzone and oxinoxate from areas down to 250 nm × 250 nm. Overall, this approach removes heat dissipation into the bulk material allowing for a faster desorption and concentration of the gas phase analyte from a single heating pulse enabling higher signal levels from a given amount of material in a single sampling spot.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The pectin puzzle: Decoding the fine structure of rhamnogalacturonan-I (RG-I) in Arabidopsis thaliana uncovers new pectin features

Pectin is generally divided into four distinct structural categories, namely homogalacturonan, xylogalacturonan, rhamnogalacturonan I (RG-I) and rhamnogalacturonan II. While much of the structural diversity of homogalacturonan, xylogalacturonan and rhamnogalacturonan II has been elucidated, the structural features of RG-I are less well understood. In this work, we employed multiple complementary analytical techniques to present a detailed structural analysis of RG-I in the model species Arabidopsis thaliana . Starting with highly purified RG-I from different Arabidopsis tissues, we employed comparative linkage and nuclear magnetic resonance analysis along with mass spectrometry analysis of enzymatically digested RG-I oligosaccharides. Besides the presence of the canonical α-1,5-arabinan, β-1,4-galactan, β-1,6-galactan and arabinogalactan RG-I side chains of varying lengths, we show that a large portion of the β-1,6-galactan is terminated by either 4-O-methyl β-glucuronic acid (GlcA) residues or, to a smaller degree, β-GlcA that lacks the Me-ether group. Importantly, O-acetylation of RG-I GalA residues is a minor modification while 10 % of the backbone Rha residues are 3-O-acetylated, and most of the acetylated Rha is additionally branched with β-galactose substituents. Taken together, the combined results of these different analytical techniques present the most comprehensive structural overview of Arabidopsis thaliana RG-I to date.

25 ENERGY STORAGE↗

Mass spectrometry structural analysis of intrinsically disordered phosphoproteins

Phosphorylation is a ubiquitous protein modification that is known to play important roles in many biological phenomena including cell signaling, the opening and closing of membrane protein channels, and even triggering of amyloid protein aggregation. Despite the effects phosphorylation has on protein function, the impact phosphorylation has on the structure of proteins is not well understood. Here, to determine how phosphorylation affects the structure of proteins, top-down mass spectrometry (TD-MS) and ion mobility-mass spectrometry (IM-MS) were performed on various phosphorylated proteins and their dephosphorylated proteoforms. TD-MS with collision- and electron-based fragmentation techniques was utilized to locate phosphorylation sites on the intrinsically disordered amyloid proteins β-casein and α-synuclein. TD-MS also provided evidence that alkaline phosphatase dephosphorylates β-casein from the N-terminus to the C-terminus. Furthermore, IM-MS of common phosphorylated proteins such as β-casein, α-casein, ovalbumin, and phosvitin indicates that phosphorylation promotes compaction of protein structure in denaturing as well as native conditions. Increases in abundance of more compact conformers are also observed when the disease related amyloid protein α-synuclein is phosphorylated at serine 129. We interpret the increased abundance of more compact conformers when proteins are phosphorylated as evidence that salt bridges form between negatively charged phosphates and positively charged residues, which alters protein structure. Salt bridge formation due to phosphorylation could be a mechanism for regulating protein function and be responsible for many of the phenomena observed in nature.

Amyloid proteins↗

Rapid droplet introduction interface (RDII) for mass spectrometry

A system for the mass spectrometry analysis of an analyte includes a droplet ejection device, a spray head comprising a spray tip for ejecting the solvent as a spray, and a solvent delivery conduit for delivering solvent to the spray tip. The spray head includes a droplet inlet opening communicating with the surrounding atmosphere for receiving liquid droplets comprising the analyte. The droplet ejection device selectively ejects a liquid analyte droplet comprising the analyte through a surrounding atmosphere and the droplet inlet opening into a solvent flowing through the solvent delivery conduit. A method for the mass spectrometry analysis of an analyte is also disclosed.

Kertesz, Vilmos↗

Analysis of useful ion yield for Si in GaN by secondary ion mass spectrometry

The optimum detection levels that can be achieved by a secondary ion mass spectrometer are dependent on how efficiently a particular species of interest can be ionized and detected. One can determine in advance whether the analysis of a particular ion in the sample is possible, if the useful ion yield is known. The useful ion yield depends on the element, instrument transmission, the analytical conditions, the sample matrix, etc. The value of the useful ion yield for a species can diverge from one instrument type to another due to its different transmission and ionization probabilities. However, the same tendencies in the results may be expected for all types of instruments. In this paper, the authors present a quantitative secondary ion mass spectrometry analysis of the useful ion yield for the silicon dopant species in a gallium nitride matrix grown by metal organic chemical vapor deposition. Positively ionized cesium was used as the primary ion beam, and its energy was varied in the range from 0.5 to 5 kV. A quadrupole mass analyzer was utilized to collect secondary ion species of interest. The analysis results can be used to determine the primary beam energies for optimal Si sensitivity.

Senevirathna, M. K. Indika (ORCID:0000000243575029↗

Results from a multi-laboratory ocean metaproteomic intercomparison: effects of LC-MS acquisition and data analysis procedures

Metaproteomics is an increasingly popular methodology that provides information regarding the metabolic functions of specific microbial taxa and has potential for contributing to ocean ecology and biogeochemical studies. A blinded multi-laboratory intercomparison was conducted to assess comparability and reproducibility of taxonomic and functional results and their sensitivity to methodological variables. Euphotic zone samples from the Bermuda Atlantic Time-series Study (BATS) in the North Atlantic Ocean collected by in situ pumps and the autonomous underwater vehicle (AUV) Clio were distributed with a paired metagenome, and one-dimensional (1D) liquid chromatographic data-dependent acquisition mass spectrometry analysis was stipulated. Analysis of mass spectra from seven laboratories through a common bioinformatic pipeline identified a shared set of 1056 proteins from 1395 shared peptide constituents. Quantitative analyses showed good reproducibility: pairwise regressions of spectral counts between laboratories yielded R 2 values averaged 0.62±0.11, and a Sørensen similarity analysis of the top 1000 proteins revealed 70 %–80 % similarity between laboratory groups. Taxonomic and functional assignments showed good coherence between technical replicates and different laboratories. A bioinformatic intercomparison study, involving 10 laboratories using eight software packages, successfully identified thousands of peptides within the complex metaproteomic datasets, demonstrating the utility of these software tools for ocean metaproteomic research. Lessons learned and potential improvements in methods were described. Future efforts could examine reproducibility in deeper metaproteomes, examine accuracy in targeted absolute quantitation analyses, and develop standards for data output formats to improve data interoperability. Together, these results demonstrate the reproducibility of metaproteomic analyses and their suitability for microbial oceanography research, including integration into global-scale ocean surveys and ocean biogeochemical models.

59 BASIC BIOLOGICAL SCIENCES↗