Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Implementation of Windowed Multipole into MCNP6.3

This work details the implementation of the Windowed MultiPole(WMP) method of generating cross sections into the monte carlo code MCNP6.3, the verification and validation performed, and potential future improvements to be implemented. Further, this work contextualizes WMP within the broader changes to how nuclear data is stored, iterated upon, and used that have been developing over the past decade.

97 MATHEMATICS AND COMPUTING↗

Mineral and organic matrix interaction in normally calcifying tendon visualized in three dimensions by high-voltage electron microscopic tomography and graphic image reconstruction

To define the ultrastructural accommodation of mineral crystals by collagen fibrils and other organic matrix components during vertebrate calcification, electron microscopic 3-D reconstructions were generated from the normally mineralizing leg tendons from the domestic turkey, Meleagris gallopavo. Embedded specimens containing initial collagen mineralizing sites were cut into 0.5-micron-thick sections and viewed and photographed at 1.0 MV in the Albany AEI-EM7 high-voltage electron microscope. Tomographic 3-D reconstructions were computed from a 2 degree tilt series of micrographs taken over a minimum angular range of +/- 60 degrees. Reconstructions of longitudinal tendon profiles confirm the presence of irregularly shaped mineral platelets, whose crystallographic c-axes are oriented generally parallel to one another and directed along the collagen long axes. The reconstructions also corroborate observations of a variable crystal length (up to 170 nm measured along crystallographic c-axes), the presence of crystals initially in either the hole or overlap zones of collagen, and crystal growth in the c-axis direction beyond these zones into adjacent overlap and other hole regions. Tomography shows for the first time that crystal width varies (30-45 nm) but crystal thickness is uniform (approximately 4-6 nm at the resolution limit of tomography); more crystals are located in the collagen hole zones than in the overlap regions at the earliest stages of tendon mineralization; the crystallographic c-axes of the platelets lie within +/- 15-20 degrees of one another rather than being perfectly parallel; adjacent platelets are spatially separated by a minimum of 4.2 +/- 1.0 nm; crystals apparently fuse in coplanar alignment to form larger platelets; development of crystals in width occurs to dimensions beyond single collagen hole zones; and a thin envelope of organic origin may be present along or just beneath the surfaces of individual mineral platelets. Implicit in the results is that the formation of crystals occurs at different sites and times by independent nucleation events in local regions of collagen. These data provide the first direct visual evidence from 3-D imaging describing the size, shape, orientation, and growth of mineral crystals in association with collagen of a normally mineralizing vertebrate tissue. They support concepts that c-axial crystal growth is unhindered by collage hole zone dimensions, that crystals are organized in the tendon in a series of generally parallel platelets, and that crystal growth in width across collagen fibrils may follow channels or grooves formed by adjacent hole zones in register.

Non-NASA Center↗

Design and Implementation of the PALM-3000 Real-Time Control System

This paper reflects, from a computational perspective, on the experience gathered in designing and implementing realtime control of the PALM-3000 adaptive optics system currently in operation at the Palomar Observatory. We review the algorithms that serve as functional requirements driving the architecture developed, and describe key design issues and solutions that contributed to the system's low compute-latency. Additionally, we describe an implementation of dense matrix-vector-multiplication for wavefront reconstruction that exceeds 95% of the maximum sustained achievable bandwidth on NVIDIA Geforce 8800GTX GPU.

PALM-3000↗

Gaussian processes for inferring parton distributions

The extraction of parton distribution functions (PDFs) from experimental or lattice QCD data is an ill-posed inverse problem, where regularization strongly impacts both systematic uncertainties and the reliability of the results. We study a framework based on Gaussian Process Regression (GPR) to reconstruct PDFs from lattice QCD matrix elements. Within a Bayesian framework, Gaussian processes serve as flexible priors that encode uncertainties, correlations, and constraints without imposing rigid functional forms. We investigate a wide range of kernel choices, mean functions, and hyperparameter treatments. We quantify information gained from the data using the Kullback-Leibler divergence. Synthetic data tests demonstrate the consistency and robustness of the method. Our study establishes GPR as a systematic and non-parametric approach to PDF reconstruction, offering controlled uncertainty estimates and reduced model bias in lattice QCD analyses.

hadronic spectroscopy↗

Logical shadow tomography: Efficient estimation of error-mitigated observables

We introduce a technique to estimate error-mitigated expectation values on noisy quantum computers. Our technique performs shadow tomography on a logical state to produce a memory-efficient classical reconstruction of the noisy density matrix. Using efficient classical post-processing, one can mitigate errors by projecting into the codespace as in subspace expansion and taking powers of the density matrix as in virtual distillation. Relative to subspace expansion which requires Ω (2^((n-1)k) samples to estimate a Pauli observable with an [[n; k]] stabilizer code, our technique requires only Ө(2^k) samples. Relative to virtual distillation, our technique can compute powers of the density matrix without implementing additional copies of quantum states the quantum computer. We present numerical results using logical states encoded with up to sixty physical qubits and show fast convergence to error-free expectation values with only 10^5 samples under 1% depolarizing noise.

quantum computing↗

Is the Matrix Completion of Reduced Density Matrices Unique?

Reduced density matrices are central to describing observables in many-body quantum systems. In electronic structure theory, the two-particle reduced density matrix (2-RDM) suffices to determine the energy and other key properties. Recent work has used matrix completion, leveraging the low-rank structure of RDMs and approximate theoretical models, to reconstruct the 2-RDM from partial data and thus reduce the computational cost. However, matrix completion is, in general, an under-determined problem. Revisiting Rosina’s theorem (Rosina, M. Queen’s Papers on Pure and Applied Mathematics , 1968, No. 11, 369), we here show that the matrix completion is unique under certain conditions, identifying the subset of 2-RDM elements that enables its exact reconstruction from incomplete information. Building on this, we introduce a hybrid quantum–stochastic algorithm that achieves exact matrix completion, demonstrated through applications to the Fermi–Hubbard model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

COxSwAIN: Compressive Sensing for Advanced Imaging and Navigation

The COxSwAIN project focuses on building an image and video compression scheme that can be implemented in a small or low-power satellite. To do this, we used Compressive Sensing, where the compression is performed by matrix multiplications on the satellite and reconstructed on the ground. Our paper explains our methodology and demonstrates the results of the scheme, being able to achieve high quality image compression that is robust to noise and corruption.

Kurwitz, Richard↗

Modulation of statolith mass and grouping in white clover (Trifolium repens) growth in 1-g, microgravity and on the clinostat

Current models of gravity perception in higher plants focus on the buoyant weight of starch-filled amyloplasts as the initial gravity signal susceptor (statolith). However, no tests have yet determined if statolith mass is regulated to increase or decrease gravity stimulus to the plant. To this end, the root caps of white clover (Trifolium repens) grown in three gravity environments with three different levels of gravity stimulation have been examined: (i) 1-g control with normal static gravistimulation, (ii) on a slow clinostat with constant gravistimulation, and (iii) in the stimulus-free microgravity aboard the Space Shuttle. Seedlings were germinated and grown in the BioServe Fluid Processing Apparatus and root cap structure was examined at both light and electron microscopic levels, including three-dimensional cell reconstruction from serial sections. Quantitative analysis of the electron micrographs demonstrated that the starch content of amyloplasts varied with seedling age but not gravity condition. It was also discovered that, unlike in starch storage amyloplasts, all of the starch granules of statolith amyloplasts were encompassed by a fine filamentous, ribosome-excluding matrix. From light micrographic 3-D cell reconstructions, the absolute volume, number, and positional relationships between amyloplasts showed (i) that individual amyloplast volume increased in microgravity but remained constant in seedlings grown for up to three days on the clinostat, (ii) the number of amyloplasts per cell remained unchanged in microgravity but decreased on the clinostat, and (iii) the three-dimensional positions of amyloplasts were not random. Instead amyloplasts in microgravity were grouped near the cell centers while those from the clinostat appeared more dispersed. Taken together, these observations suggest that changing gravity stimulation can elicit feedback control over statolith mass by changing the size, number, and grouping of amyloplasts. These results support the starch-statolith theory of graviperception in higher plants and add to current models with a new feedback control loop as a mechanism for modulation of statolith responsiveness to inertial acceleration.

Flight Experiment↗

Extraction of neutron-capture cross sections on 92 Zr using the charge-exchange Oslo method

The 93 Nb (𝑡, 3 He ) reaction at 115 MeV/nucleon was studied to demonstrate that nuclear level densities and 𝛾-ray strength functions can be extracted from charge-exchange reactions at intermediate energies using the Oslo technique. The matrix of excitation energy in 93 Zr, reconstructed from the (𝑡, 3 He ) reaction, versus the energy of 𝛾 rays emitted by the excited 93 Zr nuclei, was obtained in an experiment with the S800 Spectrograph operated in coincidence with the GRETINA 𝛾 -ray detector. The extracted level density and 𝛾 -ray strength function obtained by applying the Oslo method to this matrix were used to estimate the 92 Zr⁢(𝑛,𝛾) ⁢93 Zr cross section by combining the new results with other experimental data and theoretical calculations for 𝐸⁢1 and 𝑀⁢1 strength functions at higher energies. Good agreement with direct measurements of the 92 Zr⁢(𝑛,𝛾)⁢ 93 Zr cross section was found. The contribution from the upbend in the extracted 𝛾-ray strength function was important to achieve the consistency, as the neutron-capture cross section without this contribution is significantly below the direct measurements otherwise. Since charge-exchange reactions at intermediate energies have long been used for extracting Gamow-Teller strengths, the successful demonstration of the charge-exchange Oslo method enables experiments in which (𝑛,𝛾) cross sections and Gamow-Teller strengths can be measured simultaneously, which is of benefit for astrophysical studies.

90 ≤ A ≤ 149↗

Impact of dark matter on tidal signatures in neutron star mergers with the Einstein Telescope

If dark matter (DM) accumulates inside neutron stars (NS), it changes their internal structure and causes a shift of the tidal deformability from the value predicted by the dense-matter equation of state (EOS). In principle, this shift could be observable in the gravitational-wave (GW) signal of binary neutron star (BNS) mergers. We investigate the effect of fermionic, noninteracting DM when observing a large number of GW events from DM-admixed BNSs with the precision of the proposed Einstein telescope (ET). Specifically, we study the impact on the recovery of the baryonic EOS and whether DM properties can be constrained. For this purpose, we create event catalogs of BNS mock events with DM fraction up to 1%, from which we reconstruct the posterior uncertainties with the Fisher matrix approach. Using this data, we perform joint Bayesian inference on the baryonic EOS, DM particle mass, and DM particle fraction in each event. Here, our results reveal that when falsely ignoring DM effects, the EOS posterior is biased toward softer EOSs, though the offset is rather small. Further, we find that within our assumptions of our DM model and population, ET will likely not be able to test the presence of DM in BNSs, even when combining many events and adding Cosmic Explorer (CE) to the next-generation detector network. Likewise, the potential constraints on the DM particle mass will remain weak because of degeneracies with the fraction and EOS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantifiable Assessment of SWNT Dispersion in Polymer Composites

NASA LaRC has established a new protocol for visualizing the nanomaterials in structural polymer matrix resins. Using this new technique and reconstructing the 3D distribution of the nanomaterials allows us to compare this distribution against a theoretically perfect distribution. Additional tertiary structural information can now be obtained and quantified with the electron tomography studies. These tools will be necessary to establish the structural-functional relationships between the nano and the bulk. This will also help define the critical length scales needed for functional properties. Field ready tool development and calibration can begin by using these same samples and comparing the response. i.e. gold standards of good and bad dispersion.

Park, Cheol↗

Calibration of a synthetic aperture radiometer

Calibration algorithms for a synthetic aperture microwave radiometer are presented. The calibration is geared to Earth remote sensing applications, and is demonstrated on an airborne prototype of thinned array imager. Two approaches to the system calibration are presented; the first utilizes commonly available reference brightness temperature scenes, such as open water, and the second utilizes data collected on the antenna range. Both algorithms yield spatial response information which is cast in matrix form and inverted to obtain the image reconstruction formula. Experimental results are examined, and errors in some reconstructed images are linked to the present prototype antenna design. Algorithms for improving the synthesized antenna pattern side lobe performance are also presented. In one solution, the pattern efficiency is optimized by minimizing the pattern outside a defined beam. In another solution, the patterns are matched to a desired model pattern by the method of least squared errors. Both techniques offer an attractive alternative to aperture weighting.

Tanner, Alan B.↗

Determining the Ensemble N -Representability of Reduced Density Matrices

The N-representability problem for reduced density matrices remains a fundamental challenge in electronic structure theory. Following our previous work that employs a unitary-evolution algorithm based on an adaptive derivative-assembled pseudo-Trotter variational quantum algorithm to probe pure-state N-representability of reduced density matrices [J. Chem. Theory Comput. 2024, 20, 9968], in this work we propose a practical framework for determining the ensemble N-representability of a p-body matrix. This is accomplished using a purification strategy that embeds an ensemble state into a pure state defined on an extended Hilbert space, such that the reduced density matrices of the purified state reproduce those of the original ensemble. By iteratively applying variational unitaries to an initial purified state, the proposed algorithm minimizes the Hilbert-Schmidt distance between its p-body reduced density matrix and a specified target p-body matrix, which serves as a measure of the N-representability of the target. This methodology facilitates both error correction of defective ensemble reduced density matrices and quantum-state reconstruction on a quantum computer, offering a route for density-matrix refinement. We validate the algorithm with numerical simulations on systems of two, three, and four electrons in both simple models as well as molecular systems at finite temperature, demonstrating its robustness.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A proposed method for enhanced eigen-pair extraction using finite element methods: Theory and application

The paper covers two distinct parts: theory and application. The goal of this work was the reduction of model size with an increase in eigenvalue/vector accuracy. This method is ideal for the condensation of large truss- or beam-type structures. The theoretical approach involves the conversion of a continuum transfer matrix beam element into an 'Exact' dynamic stiffness element. This formulation is implemented in a finite element environment. This results in the need to solve a transcendental eigenvalue problem. Once the eigenvalue is determined the eigenvectors can be reconstructed with any desired spatial precision. No discretization limitations are imposed on the reconstruction. The results of such a combined finite element and transfer matrix formulation is a much smaller FEM eigenvalue problem. This formulation has the ability to extract higher eigenvalues as easily and as accurately as lower eigenvalues. Moreover, one can extract many more eigenvalues/vectors from the model than the number of degrees of freedom in the FEM formulation. Typically, the number of eigenvalues accurately extractable via the 'Exact' element method are at least 8 times the number of degrees of freedom. In contrast, the FEM usually extracts one accurate (within 5 percent) eigenvalue for each 3-4 degrees of freedom. The 'Exact' element results in a 20-30 improvement in the number of accurately extractable eigenvalues and eigenvectors.

Jara-Almonte, J.↗

Computing Challenges in Coded Mask Imaging

This slide presaentation reviews the complications and challenges in developing computer systems for Coded Mask Imaging telescopes. The coded mask technique is used when there is no other way to create the telescope, (i.e., when there are wide fields of view, high energies for focusing or low energies for the Compton/Tracker Techniques and very good angular resolution.) The coded mask telescope is described, and the mask is reviewed. The coded Masks for the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL) instruments are shown, and a chart showing the types of position sensitive detectors used for the coded mask telescopes is also reviewed. Slides describe the mechanism of recovering an image from the masked pattern. The correlation with the mask pattern is described. The Matrix approach is reviewed, and other approaches to image reconstruction are described. Included in the presentation is a review of the Energetic X-ray Imaging Survey Telescope (EXIST) / High Energy Telescope (HET), with information about the mission, the operation of the telescope, comparison of the EXIST/HET with the SWIFT/BAT and details of the design of the EXIST/HET.

Skinner, Gerald↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗