Search NASA⌕ Search

SEARCH · Search NASA

Results for “metal detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Electrical sensing, tracking, and actuation of droplets

Devices, techniques, and processes are disclosed that use electrical impedance to detect of the presence and contents of droplets including cells, nucleic acids, proteins, or solute concentrations in an array of retrievable, trackable, trapped droplets in a fluidic system. Electrodes may be positioned underneath individual droplet traps in a microchannel to assay droplet contents and/or actuating droplets for the release of the droplets from corresponding traps. The disclosed technology may be used for detection of the results of solvent extraction processes including time-dependent quantification of metal ion concentration in the aqueous and organic phases, for wastewater treatment, heavy metal detection, pharmaceutical industry, and/or biotechnology, or for environmental monitoring of wastewater for toxic metal, monitoring of biological cell viability and proliferation, monitoring of extraction processes used in heavy metal mining, monitoring of extraction processes used in nuclear fuel processing, monitoring kinetics of enzyme processes, and/or assessing pharmacodynamics and drug efficacy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Hubble Space Telescope quasar absorption line key project. I - First observational results, including Lyman-alpha and Lyman-limit systems

Spectra are presented for 37 quasars with small and moderate redshifts; the quasars were observed with the Faint Object Spectrograph of the HST. New higher resolution measurements of the absorption lines in the UV spectra of 11 quasars with emission-line redshifts that lie between 0.3 and 1.0 are reported. Calibrated spectra and continuum fits are shown for each object. A total of 104 extragalactic Ly-alpha systems are identified, nine of which are found at the same redshifts as metal-line systems. The local number density of Ly-alpha systems with rest equivalent widths larger than 0.32 A and without detected metal lines is about 15.1 +/- 4.3 Ly-alpha systems per unit redshift with gamma = 0.30 +/- 0.62 and W* = 0.22 +/- 0.02 A. A total of 10 Lyman-limit systems with an optical depth greater than 0.4 are identified. The paucity of damped Ly-alpha lines at small and moderate redshifts shows that the number density of damped absorption systems decreases with decreasing redshift.

Bahcall, John N.↗

Trace metal transfer to passerines inhabiting wastewater treatment wetlands

Wastewater treatment wetlands are cost-effective strategies for remediating trace metals in industrial effluent. However, biogeochemical exchange between wastewater treatment wetlands and adjacent environments provides opportunities for trace metals to cycle in surrounding ecosystems. The transfer of trace metals to wildlife inhabiting treatment wetlands must be considered when evaluating wetland success. Using passerine birds as bioindicators, we conducted a multi-tissue analysis to investigate the mobilization of zinc, copper, and lead derived from wastewater to terrestrial wildlife in treatment wetlands and surrounding habitat. In addition, we evaluate the strength of relationships between metal concentrations in non-lethal (blood and feathers) and lethal (muscle and liver) sample types for estimation of toxicity risk. From July 2020 to August 2021, 177 passerines of seven species were captured at two wetlands constructed to treat industrial wastewater and two reference wetlands in the coastal plain of South Carolina. Feather, blood, liver, and muscle samples from each bird were analyzed for fourteen metals using inductively coupled plasma mass spectrometry and direct mercury analysis. Passerines inhabiting wastewater treatment wetlands accumulated higher concentrations of zinc in liver, copper in blood, and lead in feathers than passerines in reference wetlands, but neither blood nor feather concentrations were correlated with internal tissue concentrations. Of all the detected metals, only mercury in the blood showed a strong predictive relationship with mercury in internal tissues. This study indicates that trace metals derived from wastewater are bioavailable and exported to terrestrial wildlife and that passerine biomonitoring is a valuable tool for assessing metal transfer from treatment wetlands. Furthermore, regular blood sampling can reveal proximate trace metal exposure but cannot predict internal body burdens for most metals.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell

In this study, we present multiplexed anodic stripping voltammetry (ASV) detection of heavy metal ions (HMIs)—As(III), Cd(II), and Pb(II)—using a homemade electrochemical cell consisting of dual working, reference and counter screen-printed electrodes (SPE) on polyimide substrate integrated with a 3D-printed flow cell. Working and counter electrodes were fabricated by the screen-printing of graphite paste while the Ag/AgCl paste was screen-printed as a reference electrode (Ag/AgCl quasi-reference electrode). The working electrodes were modified with (BiO) 2 CO 3 -reduced graphene oxide (rGO)-Nafion [(BiO) 2 CO 3 -rGO-Nafion] and Fe 3 O 4 magnetic nanoparticles (Fe 3 O 4 MNPs) decorated Au nanoparticles (AuNPs)-ionic liquid (IL) (Fe 3 O 4 -Au-IL) nanocomposites separately to enhance HMIs sensing. Electrochemical detection was achieved using square wave ASV technique. The desired structure of the flow electrochemical cell was optimized by the computational fluid dynamic (CFD). Different experimental parameters for stripping analysis of HMIs were optimized including deposition time, deposition potential and flow rate. The linear range of calibration curves with the sensing nanocomposites modified SPE for the three metal ions was from 0–50 μg/L. The limits of detection (S/N = 3) were estimated to be 2.4 μg/L for As(III), 1.2 μg/L for Pb(II) and 0.8 μg/L for Cd(II). Furthermore, the homemade flow anodic stripping sensor platform was used to detect HMIs in simulated river water with a 95–101% recovery, indicating high selectivity and accuracy and great potential for applicability even in complex matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RESULTS OF A VIRTUAL ROUND ROBIN STUDY TO ESTIMATE PROBABILITY OF DETECTION FOR DISSIMILAR METAL WELDS

This paper presents efforts to overcome challenges with empirical probability of detection (POD) estimations in the nuclear power industry through the utilization of a novel virtual flaw method. A virtual round robin (VRR) study was conducted under the Program for Investigation Of NDE by International Collaboration (PIONIC), organized by the United States Nuclear Regulatory Commission (NRC) utilizing data generated by the virtual flaw method. Analysis of results from the VRR was performed by teams from Pacific Northwest National Laboratory (PNNL), Electric Power Research Institute (EPRI), and Aalto University. Empirically derived POD estimations are presented, and challenges associated with obtaining these estimations are discussed. The virtual flaw method is introduced and some details of its implementation for the VRR activity are described. Results from POD analysis of the VRR data by PNNL, EPRI, and Aalto University are presented and a discussion regarding differences in analysis results is provided. Finally, potential future efforts to improve the application of the virtual flaw method and its estimation of POD are discussed.

Probability of detection, Dissimilar Metal Weld, P↗

The R -process Alliance: A Nearly Complete R -process Abundance Template Derived from Ultraviolet Spectroscopy of the R -process-enhanced Metal-poor Star HD 222925 *

We present a nearly complete rapid neutron-capture process (r-process) chemical inventory of the metal-poor ([Fe/H] = -1.46 ± 0.10) r-process-enhanced ([Eu/Fe] = +1.32 ± 0.08) halo star HD 222925. This abundance set is the most complete for any object beyond the solar system, with a total of 63 metals detected and seven with upper limits. It comprises 42 elements from 31 ≤ Z ≤ 90, including elements rarely detected in r-process-enhanced stars, such as Ga, Ge, As, Se, Cd, In, Sn, Sb, Te, W, Re, Os, Ir, Pt, and Au. We derive these abundances from an analysis of 404 absorption lines in ultraviolet spectra collected using the Space Telescope Imaging Spectrograph on the Hubble Space Telescope and previously analyzed optical spectra. A series of appendices discusses the atomic data and quality of fits for these lines. The r-process elements from Ba to Pb, including all elements at the third r-process peak, exhibit remarkable agreement with the solar r-process residuals, with a standard deviation of the differences of only 0.08 dex (17%). In contrast, deviations among the lighter elements from Ga to Te span nearly 1.4 dex, and they show distinct trends from Ga to Se, Nb through Cd, and In through Te. The r-process contribution to Ga, Ge, and As is small, and Se is the lightest element whose production is dominated by the r-process. The lanthanide fraction, log X La = -1.39 ± 0.09, is typical for r-process-enhanced stars and higher than that of the kilonova from the GW170817 neutron-star merger event. We advocate adopting this pattern as an alternative to the solar r-process-element residuals when confronting future theoretical models of heavy-element nucleosynthesis with observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Use a SEM on a production line

Scanning electron microscope for poor metallization detection in manufacturing cycle of semiconductor devices

Adolphsen, J. W.↗

Using the scanning electron microscope on the production line to assure quality semiconductors

The use of the scanning electron microscope to detect metallization defects introduced during batch processing of semiconductor devices is discussed. A method of determining metallization integrity was developed which culminates in a procurement specification using the scanning microscope on the production line as a quality control tool. Batch process control of the metallization operation is monitored early in the manufacturing cycle.

Adolphsen, J. W.↗

Rings of Earth detected by orbital debris radar

Small particles moving at an orbital velocity of 7.6 kilometers per second can present a considerable hazard to human activity in space. For astronauts outside of the protective shielding of their space vehicles, such particles can be lethal. The powerful radar at NASA's Goldstone Deep Communications Complex was used to monitor such orbital debris. This radar can detect metallic objects as small as 1.8 mm in diameter at 600 km altitude. The results of the preliminary survey show a flux (at 600 km altitude) of 6.4 objects per square kilometer per day of equivalent size of 1.8 mm or larger. Forty percent of the observed particles appear to be concentrated into two orbits. An orbital ring with the same inclination as the radar (35.1 degrees) is suggested. However, an orbital band with a much higher inclination (66 degrees) is also a possibility.

Goldstein, R.↗

Engine throat/nozzle optics for plume spectroscopy

The Task 2.0 Engine Throat/Nozzle Optics for Plume Spectroscopy, effort was performed under the NASA LeRC Development of Life Prediction Capabilities for Liquid Propellant Rocket Engines program. This Task produced the engineering design of an optical probe to enable spectroscopic measurements within the SSME main chamber. The probe mounts on the SSME nozzle aft manifold and collects light emitted from the throat plane and chamber. Light collected by the probe is transferred to a spectrometer through a fiber optic cable. The design analyses indicate that the probe will function throughout the engine operating cycle and is suitable for both test stand and flight operations. By detecting metallic emissions that are indicative of component degradation or incipient failure, engine shutdown can be initiated before catastrophic failure. This capability will protect valuable test stand hardware and provide enhanced mission safety.

Bickford, R. L.↗

Rings of earth

Small particles moving at an orbital velocity of 7.6 kilometers per second can present a considerable hazard to human activity in space. For astronauts outside of the protective shielding of their space vehicles, such particles can be lethal. The powerful radar at NASA's Goldstone Deep Communications Complex was used to monitor such orbital debris. This radar can detect metallic objects as small as 1.8 mm in diameter at 600 km altitude. The results of the preliminary survey show a flux (at 600 km altitude) of 6.4 objects per square kilometer per day of equivalent size of 1.8 mm or larger. Forty percent of the observed particles appear to be concentrated into two orbits. An orbital ring with the same inclination as the radar (35.1 degrees) is suggested. However, an orbital band with a much higher inclination (66 degrees) is also a possibility.

Goldstein, Richard M.↗

Results of the Aerosol Sampling Experiment on the International Space Station

The indoor air quality of the International Space Station (ISS), in terms of particulate matter, has been assessed through a sampling experiment that collected airborne debris for return to Earth. The Aerosol Sampling Experiment took place on ISS in December 2016 and January 2017, with sample return in February 2017. For redundancy, two different aerosol samplers collected particles in two size ranges spanning from 10 nm to hundreds of micrometers. Multiple analysis techniques have been used to characterize the particles, such as reflective light microscopy, manual scanning electron microscopy (SEM) analysis (secondary and backscattered imaging) with energy dispersive spectroscopy (EDS) x-ray analysis, computer controlled scanning electron microscopy (CCSEM) and Raman spectroscopy. Sampling took place in five locations on ISS, with the greatest deposition of particles in Node 3, followed by Node 1, the US Lab and Node 2. The PMM had very few airborne particles, as expected, owing to the lack of human presence. A large proportion of the sampled material consisted of fibers from clothing. Many particles had complex morphologies or contained multiple metals in a carbonaceous matrix. Metal particles were analyzed for each sampling location in terms of both weight and number percent, with 27 heavy metals detected. Fiberglass and TiO2 particles were present in every location. Quantitative analysis results are presented, and where possible, particle emission sources are identified with the intention to fuel discussions on mitigation.

Meyer, Marit E.↗

Detecting contamination on a metal surface

Thin layers of contaminant on metal surface are detected by measuring surface-potential difference between reference electrode and surface of interest. Procedure does not require mechanical contact with surface under examination.

Harris, J. M.↗

Critical Review of LPBF Metal Print Defects Detection: Roles of Selective Sensing Technology

The integrative potential of LPBF-printed parts for various innovative applications depends upon the robustness and infallibility of the part quality. Eliminating or sufficiently reducing factors contributing to the formation of defects is an integral step to achieving satisfiable part quality. Significant research efforts have been conducted to understand and quantify the triggers and origins of LPBF defects by investigating the material properties and process parameters for LPBF-printed geometries using various sensing technologies and techniques. Frequently, combinations of sensing techniques are applied to deepen the understanding of the investigated phenomena. The main objectives of this review are to cover the roles of selective sensing technologies by (1) providing a summary of LPBF metal print defects and their corresponding causes, (2) informing readers of the vast number and types of technologies and methodologies available to detect defects in LPBF-printed parts, and (3) equipping readers with publications geared towards defect detection using combinations of sensing technologies. Due to the large pool of developed sensing technology in the last few years for LPBF-printed parts that may be designed for targeting a specific defect in metal alloys, the article herein focuses on sensing technology that is common and applicable to most common defects and has been utilized in characterization for an extended period with proven efficiency and applicability to LPBF metal parts defect detection.

36 MATERIALS SCIENCE↗

Surface-Enhanced Raman Scattering Optophysiology Nanofibers for the Detection of Heavy Metals in Single Breast Cancer Cells

Mercury(II) ions (Hg2+) and silver ions (Ag+) are two of the most hazardous pollutants causing serious damage to human health. Here, we constructed surface enhanced Raman scattering (SERS)-active nanofibers covered with 4-mercaptopyridine (4-Mpy)-modified gold nanoparticles (AuNPs) to detect Hg2+ and Ag+. Experimental evidence suggests that the observed spectral changes originate from the combined effect of (i) the coordination between the nitrogen on 4-Mpy and the metal ions and (ii) the 4-Mpy molecular orientation (from flatter to more perpendicular with respect to the metal surface). The relative intensity of a pair of characteristic Raman peaks (at ~428 and ~708 cm-1) was used to quantify the metal ion concentration, greatly increasing the reproducibility of the measurement compared to signal-on or signal-off detection based on a single SERS peak. The detection limit of this method for Hg2+ is lower than that for the Ag+ (5 nM vs 100 nM), which can be explained by the stronger interaction energy between Hg2+ and N compared to Ag+ and N, as demonstrated by density functional theory (DFT) calculations. The Hg2+ and Ag+ ions can be masked by adding ethylenediaminetetraacetate (EDTA) and Cl-, respectively, to the Hg2+ and Ag+ samples. The good sensitivity, high reproducibility and excellent selectivity of these nanosensors were also demonstrated. Furthermore, detection of Hg2+ in living breast cancer cells at the subcellular level is possible thanks to the nanometric size of the herein described SERS nanosensors, allowing high spatial resolution and minimal cell damage.

Zhao, Xingjuan↗

In-Situ FTIR Detection of Transition Metal (TM)-Ion Dissolution From Cathodes in Li-Ion Batteries

Transition metal (TM) ions, commonly Ni and Mn, play a crucial role in Li-ion battery cathodes as the reaction centers for rapid redox reactions. A major challenge with TM-based cathodes is capacity degradation, particularly at higher operating voltages. This degradation is closely linked to the dissolution of TMs from the cathode materials and their subsequent deposition on the anode. This process not only modifies the surface structure of the cathode but, more significantly, alters the SEI composition on the anode [1-2]. The dissolution of TMs cations into a liquid electrolyte from cathode materials, such as Mn-ion dissolution from Mn-rich cathode (LMR), is detrimental to the cycling performance of Li-ion batteries [3-4]. Much attention has been paid to this issue but there remains a lack of characterization techniques which can detect the TM-ion dissolution from the cathode during electrochemical measurements. In our study, we use in-situ ATR-FTIR as an effective technique to probe the TM-ion dissolution from the cathode. We have first demonstrated the detrimental effects of TM ions on the electrochemical performance of Li-ion batteries by adding a small amount of TM salt (50 mM Mn(PF6)) to the electrolyte of a Li-ion coin cell with LFP and graphite electrode. We observed a rapid capacity fade after the first delithiation cycle. To investigate TM ion dissolution, we established a baseline IR spectrum for various TM solvation states (such as Mn and Ni) by measuring concentration-dependent IR spectra. This baseline spectrum helps us detect TM ion dissolution during battery cycling. In this work, we discuss in detail the effect of TM ions on the electrochemical performance of Li-ion batteries and the detection of TM ions during battery cycling using in-situ FTIR spectroscopy. We will compare TM dissolution between coated and uncoated cathodes to examine the effect of cathode coatings to mitigate degradation due to TM dissolution and cross-over from cathode to anode. References: (1) Zhan, C.; Wu, T.; Lu, J.; Amine, K. Dissolution, migration, anddeposition of transition metal ions in Li-ion batteries exemplified byMn-based cathodes - a critical review. Energy Environ. Sci. 2018, 11,243-257. (2) Jung, R.; Linsenmann, F.; Thomas, R.; Wandt, J.; Solchenbach,S.; Maglia, F.; Stinner, C.; Tromp, M.; Gasteiger, H. A. Nickel,Manganese, and Cobalt Dissolution from Ni-Rich NMC and TheirEffects on NMC622-Graphite Cells. J. Electrochem. Soc. 2019, 166,A378-A389. (3) Zhao, L.; Chenard, E.; Capraz, O. O.; Sottos, N. R.; White, S.R. Direct Detection of Manganese Ions in Organic Electrolyte by UV-Vis Spectroscopy. J. Electrochem. Soc. 2018, 165, A345-A348 (4) Zhang, Y.; Hu, A.; Xia, D.; Hwang, S.; Sainio, S.; Nordlund, D.;Michel, F. M.; Moore, R. B.; Li, L.; Lin, F. Operando characterization and regulation of metal dissolution and redeposition dynamics nearbattery electrode surface. Nat. Nanotechnol. 2023, 18, 790.

25 ENERGY STORAGE↗

On the detectability of a metallized lunar core

Calculations are made of the expected complex electromagnetic gain of the moon using current models of the internal bulk electrical conductivity with the addition of conducting cores of varying radii. The results show that the phase of the response (gain) function is sensitive to the radius and conductivity. The gain amplitude varies in a complicated way for frequencies above (0) 10 microHz. Below this 'corner' frequency, the square of the gain amplitude varies approximately quadratically with frequency and therefore inverse quadratically with hydromagnetic wavelength in the solar wind. The addition of conducting cores alters this dependence. A 'flat' frequency independent range for the gain amplitude evolves, which is a second way, in principle, to detect a conducting core. The departure from the lambda to the -4th Rayleigh scattering law is due to a combination of the conductivity of the moon and the relative unimportance of confinement of the induced fields at the very low frequencies of interest for core detection. For some core parameters, detection is not feasible with current data, and data recording times varying from several months to centuries would be required.

Wiskerchen, M. J.↗