Search NASA⌕ Search

SEARCH · Search NASA

Results for “micro resonators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Enabling Space Biological Knowledge Discovery Through Image and Video Data Sharing

Increased biomedical risks and challenges associated with deep space missions and experiments (cis-Lunar, Mars transit/surface) require new knowledge discovery and development of novel ecosystems. Supporting distant and long-duration missions and experiments requires biological data (from yeast, microbes, fruit flies, C. elegans, plants, crops, rodents, humans) be findable, accessible, interoperable, reusable (FAIR), and maximally open-access. As data-intensive, bioinformatic, meta-analytical, and computer-assisted approaches continue to be a centerpiece of modern research, the NASA Biological and Physical Sciences division is expanding its Open Science capabilities beyond NASA GeneLab. The NASA Ames Life Sciences Data Archive (ALSDA) is a repository which is responsible for collecting and access to space biological imagery and video, alongside tabular and environmental data. In this presentation, we will discuss strategies dealing with archiving, curating, and accessibility of images from very distinct imaging modalities (e.g., micro-computed tomography, magnetic resonance imaging, photographic images of plants, fluorescence microscopy, behavioral videos, etc.). There are two main challenges: 1. Open-source data storage and 2. Metadata related to the imagery-video. Both have been solved by leveraging two existing open-source systems. For data storage, ALSDA is utilizing components through the Open Microscopy Environment (OME), which can read most imaging proprietary formats and display on a web interface complex multidimensional images (Z stack, multi-channel, temporal, spectral). Most technical metadata from imaging modalities are captured seamlessly. For metadata capturing experimental details, ALSDA (like GeneLab) uses the ISA-Tab specification which relies on the ISA data model to order and classify metadata. The ISA data model uses a tree structure with three files to capture the metadata: The top layer is the Investigations file, the second layer is the Study file(s), and the last layer is the Assay file(s). We believe such an approach may be useful for other types of image research data from other investigators in the AGU community.

imaging↗

Assessment of Operation of EMK21 MEMS Silicon Oscillator Over Wide Temperature Range

Electronic control systems, data-acquisition instrumentation, and microprocessors require accurate timing signals for proper operation. Traditionally, ceramic resonators and crystal oscillators provided this clock function for the majority of these systems. Over the last few years, MEMS (Micro-Electro-Mechanical Systems) resonator-based oscillators began to surface as commercial-off-the-shelf (COTS) parts by a few companies. These quartz-free, miniature silicon devices could easily replace the traditional crystal oscillators in providing the timing/clock function for many digital and analog circuits. They are reported to provide stable output frequency, offer great tolerance to shock and vibration, and are immune to electro-static discharge [ 1-2]. In addition, they are encapsulated in compact lead-free packages and cover a wide frequency range (1 MHz to 125 MHz). The small size of the MEMS oscillators along with their thermal stability make them ideal candidates for use in space exploration missions. Limited data, however, exist on the performance and reliability of these devices under operation in applications where extreme temperatures or thermal cycling swings, which are typical of space missions, are encountered. This report presents the results of the work obtained on the evaluation of an Ecliptek Corporation MEMS silicon oscillator chip under extreme temperatures.

Patterson, Richard L.↗

Fabrication of an Absorber-Coupled MKID Detector

Absorber-coupled microwave kinetic inductance detector (MKID) arrays were developed for submillimeter and far-infrared astronomy. These sensors comprise arrays of lambda/2 stepped microwave impedance resonators patterned on a 1.5-mm-thick silicon membrane, which is optimized for optical coupling. The detector elements are supported on a 380-mm-thick micro-machined silicon wafer. The resonators consist of parallel plate aluminum transmission lines coupled to low-impedance Nb microstrip traces of variable length, which set the resonant frequency of each resonator. This allows for multiplexed microwave readout and, consequently, good spatial discrimination between pixels in the array. The transmission lines simultaneously act to absorb optical power and employ an appropriate surface impedance and effective filling fraction. The fabrication techniques demonstrate high-fabrication yield of MKID arrays on large, single-crystal membranes and sub-micron front-to-back alignment of the micro strip circuit. An MKID is a detector that operates upon the principle that a superconducting material s kinetic inductance and surface resistance will change in response to being exposed to radiation with a power density sufficient to break its Cooper pairs. When integrated as part of a resonant circuit, the change in surface impedance will result in a shift in its resonance frequency and a decrease of its quality factor. In this approach, incident power creates quasiparticles inside a superconducting resonator, which is configured to match the impedance of free space in order to absorb the radiation being detected. For this reason MKIDs are attractive for use in large-format focal plane arrays, because they are easily multiplexed in the frequency domain and their fabrication is straightforward. The fabrication process can be summarized in seven steps: (1) Alignment marks are lithographically patterned and etched all the way through a silicon on insulator (SOI) wafer, which consists of a thin silicon membrane bonded to a thick silicon handle wafer. (2) The metal microwave circuitry on the front of the membrane is patterned and etched. (3) The wafer is then temporarily bonded with wafer wax to a Pyrex wafer, with the SOI side abutting the Pyrex. (4) The silicon handle component of the SOI wafer is subsequently etched away so as to expose the membrane backside. (5) The wafer is flipped over, and metal microwave circuitry is patterned and etched on the membrane backside. Furthermore, cuts in the membrane are made so as to define the individual detector array chips. (6) Silicon frames are micromachined and glued to the silicon membrane. (7) The membranes, which are now attached to the frames, are released from the Pyrex wafer via dissolution of the wafer wax in acetone.

Brown, Ari↗

Performance of MEMS Silicon Oscillator, ASFLM1, under Wide Operating Temperature Range

Over the last few years, MEMS (Micro-Electro-Mechanical Systems) resonator-based oscillators began to be offered as commercial-off-the-shelf (COTS) parts by a few companies [1-2]. These quartz-free, miniature silicon devices could compete with the traditional crystal oscillators in providing the timing (clock function) for many digital and analog electronic circuits. They provide stable output frequency, offer great tolerance to shock and vibration, and are immune to electro-static discharge [1-2]. In addition, they are encapsulated in compact lead-free packages, cover a wide frequency range (1 MHz to 125 MHz), and are specified, depending on the grade, for extended temperature operation from -40 C to +85 C. The small size of the MEMS oscillators along with their reliability and thermal stability make them candidates for use in space exploration missions. Limited data, however, exist on the performance and reliability of these devices under operation in applications where extreme temperatures or thermal cycling swings, which are typical of space missions, are encountered. This report presents the results of the work obtained on the evaluation of an ABRACON Corporation MEMS silicon oscillator chip, type ASFLM1, under extreme temperatures.

Patterson, Richard L.↗

Reconfigurable Microwave Phase Delay Element for Frequency Reference and Phase-Shifter Applications

A technique was developed to provide a reconfigurable high-precision micro - wave electrical phase delay for resonators and phase shifters. The invention employs multiple branches of transmission lines with open-ended or ground-ended terminations as configurable bits or digits. This technique minimizes the errors due to limited precision of switching devices. In addition, the proposed linear analytical approach significantly produces a much simpler design than that of other prior inventions at the time of this reporting. Microwave components such as filters, phase delay elements, or resonators require a method that can accurately adjust their frequency responses. Most tuning techniques offer very wide frequency tuning range; however, it is often difficult and expensive to tune their response in a very narrow operating frequency, especially when the tuning element reaches its minimum discrete step due to fabrication tolerances. The problem becomes worse as the operating frequency is in mm-wave frequency range (>26 GHz). The electrical tuning sensitivity of a microwave line is dependent on the position of the tuning element with respect to the reference termination. By placing this tuning element away from this reference with the main transmission line connecting the two elements together the sensitivity of the tuning element can change significantly. This concept can be used in the system that requires multiple tuning sensitivities. In this case, multiple tuning branches are superimposed in the main transmission line. The proposed invention allows the transmission-line electrical length to be accurately programmed using switching elements that have limited accuracy. The invention consists of multiple branches of transmission lines connected to discrete switching devices with open-ended terminations. They are used as discrete tuning elements. These elements are connected to the main microwave transmission line and are separated by a well-defined electrical degree spacing. Each branch is programmed to have different electrical degree sensitivity, such as a combination of discrete steps in each branch, which results in a reflective line with a unique effective phase response. To reduce the number of switching devices, it is desirable to program the devices in binary configuration where each branch represents one bit in the base-2 number system. This invention allows the transmission line electrical length to be tuned precisely with customizable sensitivity based on the known sensitivity of the base tuning circuit. The tuning resolution is dependent on the distance among tuning branches.

Hsieh, Wen-Ting↗

Silicon carbon alloy thin film depositions using electron cyclotron resonance microwave plasmas

Amorphous and microcrystalline silicon carbon films (a-SiC:H, micro-c-SiC:H) have been deposited using SiH4, CH4 and H2 mixed gas ECR (electron cyclotron resonance) plasmas. The optical bandgap of a-SiC:H films is not dependent on the hydrogen dilution in the ECR plasma. The deposition rate of a-SiC:H films is found to be strongly dependent on the ECR magnetic field and the hydrogen dilution. The hydrogen dilution effect on the deposition rate indicates that the etching in ECR hydrogen plasmas plays an important role in the deposition of a-SiC:H films. The optical constants n and k of ECR-deposited a-SiC:H films in the wavelength region of 0.4 to 1.0 micron are determined to be 2.03-1.90 and 0.04-0.00, respectively. The microstructures of ECR-deposited micro-c-SiC:H films are shown by X-ray diffraction and SEM (scanning electron microscopy) to be composed of 1000-A alpha-SiC microcrystallites and amorphous network structures.

Shing, Y. H.↗

Split-resonator integrated-post MEMS gyroscope

A split-resonator integrated-post vibratory microgyroscope may be fabricated using micro electrical mechanical systems (MEMS) fabrication techniques. The microgyroscope may include two gyroscope sections bonded together, each gyroscope section including resonator petals, electrodes, and an integrated half post. The half posts are aligned and bonded to act as a single post.

Bae, Youngsam↗

Spatial and temporal behavior of ULF pulsations observed by the Goose Bay HF radar

Techniques which allow the instantaneous amplitude and phase to be determined as functions of geomagnetic lattitude, longitude, and time are employed to carry out a detailed analysis of HF radar data of a ULF pulsation event in the postmidnight sector on January 11, 1989. Field line resonances with several different frequencies occur simultaneously at different latitudes. These can be associated with cavity mode frequencies of 1.3 mHz, 1.9 mHz, 2.7 mGz, and 3.3 mHz. These frequencies are constant to better than 10 percent over a local time period of nearly 4 hr. The field-aligned currents driven by the resonances can be as large as 5 micro-A/sq m at ionospheric heights. The data support a picture of modes driven by solar wind impulses.

Walker, A. D. M.↗

Advanced imaging of the macrostructure and microstructure of bone

Noninvasive and/or nondestructive techniques are capable of providing more macro- or microstructural information about bone than standard bone densitometry. Although the latter provides important information about osteoporotic fracture risk, numerous studies indicate that bone strength is only partially explained by bone mineral density. Quantitative assessment of macro- and microstructural features may improve our ability to estimate bone strength. The methods available for quantitatively assessing macrostructure include (besides conventional radiographs) quantitative computed tomography (QCT) and volumetric quantitative computed tomography (vQCT). Methods for assessing microstructure of trabecular bone noninvasively and/or nondestructively include high-resolution computed tomography (hrCT), micro-computed tomography (muCT), high-resolution magnetic resonance (hrMR), and micromagnetic resonance (muMR). vQCT, hrCT and hrMR are generally applicable in vivo; muCT and muMR are principally applicable in vitro. Although considerable progress has been made in the noninvasive and/or nondestructive imaging of the macro- and microstructure of bone, considerable challenges and dilemmas remain. From a technical perspective, the balance between spatial resolution versus sampling size, or between signal-to-noise versus radiation dose or acquisition time, needs further consideration, as do the trade-offs between the complexity and expense of equipment and the availability and accessibility of the methods. The relative merits of in vitro imaging and its ultrahigh resolution but invasiveness versus those of in vivo imaging and its modest resolution but noninvasiveness also deserve careful attention. From a clinical perspective, the challenges for bone imaging include balancing the relative advantages of simple bone densitometry against the more complex architectural features of bone or, similarly, the deeper research requirements against the broader clinical needs. The considerable potential biological differences between the peripheral appendicular skeleton and the central axial skeleton have to be addressed further. Finally, the relative merits of these sophisticated imaging techniques have to be weighed with respect to their applications as diagnostic procedures requiring high accuracy or reliability on one hand and their monitoring applications requiring high precision or reproducibility on the other. Copyright 2000 S. Karger AG, Basel.

NASA Discipline Musculoskeletal↗

NASA Tech Briefs, September 2009

opics covered include: Filtering Water by Use of Ultrasonically Vibrated Nanotubes; Computer Code for Nanostructure Simulation; Functionalizing CNTs for Making Epoxy/CNT Composites; Improvements in Production of Single-Walled Carbon Nanotubes; Progress Toward Sequestering Carbon Nanotubes in PmPV; Two-Stage Variable Sample-Rate Conversion System; Estimating Transmitted-Signal Phase Variations for Uplink Array Antennas; Board Saver for Use with Developmental FPGAs; Circuit for Driving Piezoelectric Transducers; Digital Synchronizer without Metastability; Compact, Low-Overhead, MIL-STD-1553B Controller; Parallel-Processing CMOS Circuitry for M-QAM and 8PSK TCM; Differential InP HEMT MMIC Amplifiers Embedded in Waveguides; Improved Aerogel Vacuum Thermal Insulation; Fluoroester Co-Solvents for Low-Temperature Li+ Cells; Using Volcanic Ash to Remove Dissolved Uranium and Lead; High-Efficiency Artificial Photosynthesis Using a Novel Alkaline Membrane Cell; Silicon Wafer-Scale Substrate for Microshutters and Detector Arrays; Micro-Horn Arrays for Ultrasonic Impedance Matching; Improved Controller for a Three-Axis Piezoelectric Stage; Nano-Pervaporation Membrane with Heat Exchanger Generates Medical-Grade Water; Micro-Organ Devices; Nonlinear Thermal Compensators for WGM Resonators; Dynamic Self-Locking of an OEO Containing a VCSEL; Internal Water Vapor Photoacoustic Calibration; Mid-Infrared Reflectance Imaging of Thermal-Barrier Coatings; Improving the Visible and Infrared Contrast Ratio of Microshutter Arrays; Improved Scanners for Microscopic Hyperspectral Imaging; Rate-Compatible LDPC Codes with Linear Minimum Distance; PrimeSupplier Cross-Program Impact Analysis and Supplier Stability Indicator Simulation Model; Integrated Planning for Telepresence With Time Delays; Minimizing Input-to-Output Latency in Virtual Environment; Battery Cell Voltage Sensing and Balancing Using Addressable Transformers; Gaussian and Lognormal Models of Hurricane Gust Factors; Simulation of Attitude and Trajectory Dynamics and Control of Multiple Spacecraft; Integrated Modeling of Spacecraft Touch-and-Go Sampling; Spacecraft Station-Keeping Trajectory and Mission Design Tools; Efficient Model-Based Diagnosis Engine; and DSN Simulator.

Source record↗

Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

Van Amerom, Friso H.↗

NASA Tech Briefs, September 2012

Topics covered include: Beat-to-Beat Blood Pressure Monitor; Measurement Techniques for Clock Jitter; Lightweight, Miniature Inertial Measurement System; Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts; Fuel Cell/Electrochemical Cell Voltage Monitor; Anomaly Detection Techniques with Real Test Data from a Spinning Turbine Engine-Like Rotor; Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks; Antenna Calibration and Measurement Equipment; Glass Solder Approach for Robust, Low-Loss, Fiber-to-Waveguide Coupling; Lightweight Metal Matrix Composite Segmented for Manufacturing High-Precision Mirrors; Plasma Treatment to Remove Carbon from Indium UV Filters; Telerobotics Workstation (TRWS) for Deep Space Habitats; Single-Pole Double-Throw MMIC Switches for a Microwave Radiometer; On Shaft Data Acquisition System (OSDAS); ASIC Readout Circuit Architecture for Large Geiger Photodiode Arrays; Flexible Architecture for FPGAs in Embedded Systems; Polyurea-Based Aerogel Monoliths and Composites; Resin-Impregnated Carbon Ablator: A New Ablative Material for Hyperbolic Entry Speeds; Self-Cleaning Particulate Prefilter Media; Modular, Rapid Propellant Loading System/Cryogenic Testbed; Compact, Low-Force, Low-Noise Linear Actuator; Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link; Process for Measuring Over-Center Distances; Hands-Free Transcranial Color Doppler Probe; Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs; Developing Physiologic Models for Emergency Medical Procedures Under Microgravity; PMA-Linked Fluorescence for Rapid Detection of Viable Bacterial Endospores; Portable Intravenous Fluid Production Device for Ground Use; Adaptation of a Filter Assembly to Assess Microbial Bioburden of Pressurant Within a Propulsion System; Multiplexed Force and Deflection Sensing Shell Membranes for Robotic Manipulators; Whispering Gallery Mode Optomechanical Resonator; Vision-Aided Autonomous Landing and Ingress of Micro Aerial Vehicles; Self-Sealing Wet Chemistry Cell for Field Analysis; General MACOS Interface for Modeling and Analysis for Controlled Optical Systems; Mars Technology Rover with Arm-Mounted Percussive Coring Tool, Microimager, and Sample-Handling Encapsulation Containerization Subsystem; Fault-Tolerant, Real-Time, Multi-Core Computer System; Water Detection Based on Object Reflections; SATPLOT for Analysis of SECCHI Heliospheric Imager Data; Plug-in Plan Tool v3.0.3.1; Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum; Nonlinear Estimation Approach to Real-Time Georegistration from Aerial Images; Optimal Force Control of Vibro-Impact Systems for Autonomous Drilling Applications; Low-Cost Telemetry System for Small/Micro Satellites; Operator Interface and Control Software for the Reconfigurable Surface System Tri-ATHLETE; and Algorithms for Determining Physical Responses of Structures Under Load.

Source record↗

Picosecond Pulsed Laser Ablation for the Surface Preparation of Epoxy Composites

As part of a technical challenge under the Advanced Composites Program, methods for improving pre-bond process control for aerospace composite surface treatments and inspections, in conjunction with Federal Aviation Administration guidelines, are under investigation. The overall goal is to demonstrate high fidelity, rapid and reproducible surface treatment and surface characterization methods to reduce uncertainty associated with the bonding process. The desired outcomes are reliable bonded airframe structure, and reduced timeline to certification. In this work, laser ablation was conducted using a q-switched Nd:YVO4 laser capable of nominal pulse durations of 8 picoseconds (ps). Aerospace structural carbon fiber reinforced composites with an epoxy resin matrix were laser treated, characterized, processed into bonded assemblies and mechanically tested. The characterization of ablated surfaces were conducted using scanning electron microscopy (SEM), water contact angle (WCA) goniometry, micro laser induced breakdown spectroscopy (uLIBS), and electron spin resonance (ESR). The bond performance was assessed using a double cantilever beam (DCB) test with an epoxy adhesive. The surface characteristics and bond performance obtained from picosecond ablated carbon fiber reinforced plastics (CFRPs) are presented herein.

Palmieri, Frank↗

Expanding Repository Data Available For Sharing and Knowledge Discovery

Some of the hardest space biology and space health challenges require data-intensive, bioinformatic, meta-analytical, and computer-assisted research approaches. These challenges include examining interdisciplinary space life science research across experiments and across interacting spaceflight hazards (radiation, altered gravity, confinement, hostile-closed environments, distance-duration from Earth). The approaches to confront these challenges involve mining multiple datasets simultaneously from various hierarchical organizations of biological complexity, all while concurrently evaluating how experimental design factors affect endpoints of standard assays. To enable this field, it is essential that principal investigators (PIs) submit data in a structure so it can be maximally re-used. The purpose of the NASA Ames Life Sciences Data Archive (ALSDA) is to collect, curate, and make publicly available all non-human space-relevant biological data. ALSDA must also ensure data are open-access, and maximally findable, accessible, interoperable, and reusable (FAIR). The scope of ALSDA data collected and submitted by PIs include subject and study design metadata, assay metadata parameters, raw and processed assay data, assay imagery/video, and subject-experienced mission data telemetry (radiation, temperature, humidity, acoustics, vibrations, etc.). ALSDA recently integrated into a collaborative group of Open Science projects to facilitate a suite of new tools and workflows that will improve data submission, accessibility, and reusability by implementing digital data submission agreements, and adopting the data management system originally developed by NASA GeneLab. ALSDA intends to bring current biological repository data and all future collected data into this new scientific data reuse reality. This new suite of tools will enable ALSDA to deploy a science curation system using scientific assay configurations for the data submission portal. It will capture essential assay parameters according to established standards in each sub-field within biology. The submission portal expedites data collection by enhancing ease of PI data submission, providing a user interface and specificity for which data is to be submitted. Data submissions can be brought into cutting-edge informatic analysis portals to enable mining of physiological, behavioral, biochemical, and imaging datasets in conjunction with ‘omics-level datasets. As ALSDA datasets are submitted, curated, and published (e.g., micro-computed tomography, histology, pulse oximetry, serum metabolites, magnetic resonance imaging, intraocular pressure, novel object recognition, etc.), the merging together of spaceflight data along this multi-hierarchical complexity of biology will enable informatics and data-intensive approaches resulting in knowledge discoveries across missions, space hazards, and biological disciplines.

Biology↗

Expanding Repository Data Available For Sharing And Knowledge Discovery

Some of the hardest space biology and space health challenges require data-intensive, bioinformatic, meta-analytical, and computer-assisted research approaches. These challenges include examining interdisciplinary space life science research across experiments and across interacting spaceflight hazards (radiation, altered gravity, confinement, hostile-closed environments, distance-duration from Earth). The approaches to confront these challenges involve mining multiple datasets simultaneously from various hierarchical organizations of biological complexity, all while concurrently evaluating how experimental design factors affect endpoints of standard assays. To enable this field, it is essential that principal investigators (PIs) submit data in a structure so it can be maximally re-used. The purpose of the NASA Ames Life Sciences Data Archive (ALSDA) is to collect, curate, and make publicly available all non-human space-relevant biological data. ALSDA must also ensure data are open-access, and maximally findable, accessible, interoperable, and reusable (FAIR). The scope of ALSDA data collected and submitted by PIs include subject and study design metadata, assay metadata parameters, raw and processed assay data, assay imagery/video, and subject-experienced mission data telemetry (radiation, temperature, humidity, acoustics, vibrations, etc.). ALSDA recently integrated into a collaborative group of Open Science projects to facilitate a suite of new tools and workflows that will improve data submission, accessibility, and reusability by implementing digital data submission agreements, and adopting the data management system originally developed by NASA GeneLab. ALSDA intends to bring current biological repository data and all future collected data into this new scientific data reuse reality. This new suite of tools will enable ALSDA to deploy a science curation system using scientific assay configurations for the data submission portal. It will capture essential assay parameters according to established standards in each sub-field within biology. The submission portal expedites data collection by enhancing ease of PI data submission, providing a user interface and specificity for which data is to be submitted. Data submissions can be brought into cutting-edge informatic analysis portals to enable mining of physiological, behavioral, biochemical, and imaging datasets in conjunction with ‘omics-level datasets. As ALSDA datasets are submitted, curated, and published (e.g., micro-computed tomography, histology, pulse oximetry, serum metabolites, magnetic resonance imaging, intraocular pressure, novel object recognition, etc.), the merging together of spaceflight data along this multi-hierarchical complexity of biology will enable informatics and data-intensive approaches resulting in knowledge discoveries across missions, space hazards, and biological disciplines.

life science↗

Nonstationary coupling between the magnetosphere and ionosphere

Resonant coupling of large scale MHD waves to small scale kinetic Alfven waves is described. The small-scale waves drive field-aligned currents tens of micro A/sqm into the ionosphere with accelerated electrons of energies a few keV. Bounce resonant interaction with standing kinetic Alfven waves may precipitate higher energy electrons. East-west aligned arcs should be thinnest and move polewards relative to the plasma at the poleward edge. Downward travelling wave packets trap electrons between the wave front and the ionosphere whose energy is below the peak energy and whose phase-space density should be independent of the peak energy.

Goertz, C. K.↗

Tuning of MEMS Gyroscope using Evolutionary Algorithm and "Switched Drive-Angle" Method

We propose a tuning method for Micro-Electro-Mechanical Systems (MEMS) gyroscopes based on evolutionary computation that has the capacity to efficiently increase the sensitivity of MEMS gyroscopes through tuning and, furthermore, to find the optimally tuned configuration for this state of increased sensitivity. We present the results of an experiment to determine the speed and efficiency of an evolutionary algorithm applied to electrostatic tuning of MEMS micro gyros. The MEMS gyro used in this experiment is a pyrex post resonator gyro (PRG) in a closed-loop control system. A measure of the quality of tuning is given by the difference in resonant frequencies, or frequency split, for the two orthogonal rocking axes. The current implementation of the closed-loop platform is able to measure and attain a relative stability in the sub-millihertz range, leading to a reduction of the frequency split to less than 100 mHz.

Micro-Electro-Mechanical Systems (MEMS)↗