Search NASA⌕ Search

SEARCH · Search NASA

Results for “microplasmas”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Generating and Sustaining Microplasma with Microwaves (Final Report)

Plasma can be generated in spaces ranging in size from astronomical down to the microscopic. The physics that describes the gas breakdown is different at each size scale. The dominant physical phenomenon also depends on the type of electromagnetic field that drives the breakdown – static, AC, RF, microwave, visible. This project, staffed by undergraduate researchers and their mentor, focused on plasma generated in the size range of 10 to 500 micrometers using microwave energy. This project was motivated by the prior observation that plasma can only be generated in microgaps when the gas is above a certain gap-dependent pressure, here called the transition pressure. A microwave-driven microgap was designed and constructed in this project and then used to measure the electric field required to initiate plasma over a wide range of pressures from 0.1 Torr to 760 Torr (1 atmosphere).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring the THz Frontier of Experimental Microplasma (Final Report)

This is the final report for a three-year program to explore photonic crystals as a scalable medium for creating extremely high frequency plasma. The plasmas are then experimentally characterized and modeled. The conclusion of this work is that the photonic crystal is an attractive mode for creating plasma devices that extend into the THz band.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kinetic Modeling and Experimental Studies of Capacitively Coupled Macro- and Microplasmas at Microwave Frequencies

The effect of driving frequency in the range of 13.56 MHz to 73 MHz on electron energy distribution and electron heating modes in a 50 mTorr capacitively coupled argon plasma discharge is studied using 1D-3V particle-in-cell simulations. Calculated electron energy probability functions exhibit three distinct temperatures for low-, mid-, and high-energy electrons at all the studied driving frequencies. When compared to published experimental data, the calculated probability functions show a reasonable agreement for the energy range resolved in the measurements (about 2 eV to 10 eV). Discrepancies due to limitations in experimental energy resolution outside this range lead to differences between computational and experimental values of the electron number density determined from the distribution functions, and the predicted effective electron temperature is within 25 % of experimental values. The impedance of the discharge is interpreted in terms of a homogeneous equivalent circuit model and the driving frequency dependence of the inferred combined sheath thickness is found to obey a known, theoretically-derived, power law. The average power transferred from the field to the electrons (electron heating) is computed, and a region of negative heating near the sheath edge, particularly at higher driving frequencies, is identified. Analysis of the electron momentum equation shows that electron inertia, which on temporal averaging would be zero in a linear regime, is responsible for negative values of power deposition near the sheath edge at high driving frequencies due to the highly nonlinear behavior of the discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Commercialization of microcavity plasma devices and arrays: Systems for VUV photolithography and nanopatterning, disinfection of drinking water and air, and biofilm deactivation for medical therapeutics

Abstract A little more than two decades after the introduction of the first microcavity plasma devices, a growing body of commercial products based on the remarkable properties of these low‐temperature, atmospheric plasmas is now available. Following a brief review of early microplasma lamp development, this article describes microplasma‐based devices and systems currently being manufactured for applications in photolithography, photopatterning, and other nanofabrication processes, such as atomic layer deposition, spectroscopic identification and analysis of materials (including wide bandgap crystals), the disinfection of drinking water in off‐grid communities, deactivating COVID‐19 and other pathogens in air and on surfaces in public spaces, and vacuum ultraviolet lamps for driving atomic clocks. The microplasma‐based treatment of otitis media in the human ear will also be discussed.

42 ENGINEERING↗

SOMAFOAM: An OpenFOAM based solver for continuum simulations of low-temperature plasmas

Here, we report the development of SOMAFOAM, a finite volume framework for performing continuum simulations of low-temperature plasmas. The primary goal of this work is to discuss the features of SOMAFOAM along with representative results provided as examples for a range of operating conditions and geometries. This includes plasma and plasma–dielectric systems operating in direct current, radio frequency, and microwave regimes from pressures as low as 100 mTorr to atmospheric pressure. The code has several useful features including the ability to run massively parallel simulations using arbitrary geometries, structured/unstructured meshes, choice of models such as drift–diffusion/full-momentum at runtime, and species-dependent timesteps to name a few. The verification/validation studies presented include comparison with previously published continuum simulations (low-pressure direct current and radio frequency plasma), with experiments (Gaseous Electronics Conference Reference Cell and microwave microplasma ignited in a split ring resonator), and previously published kinetic simulations (low-pressure radio frequency plasma). Other examples provided include a direct current atmospheric pressure microplasma bounded by dielectric sidewalls and a helium–nitrogen plasma ignited using a needle electrode facing a dielectric. The performance of the code is also discussed with serial and distributed memory parallel runs demonstrated up to 512 cores. The design and implementation of the code in a modular object-oriented framework allows for easy extension and seamless coupling with other codes and can be expected to play an important role in both academia and industry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

Direct imaging of plasma waves using ultrafast electron microscopy

A femtosecond plasma imaging modality based on a new development of ultrafast electron microscope is introduced. We investigated the laser-induced formation of high-temperature electron microplasmas and their subsequent non-equilibrium evolution. Based on a straightforward field imaging principle, we directly retrieve detailed information about the plasma dynamics, including plasma wave structures, particle densities, and temperatures. We discover that directly subjected to a strong magnetic field, the photo-generated microplasmas manifest in novel transient cyclotron echoes and form new wave states across a broad range of field strengths and different laser fluences. Intriguingly, the transient cyclotron waves morph into a higher frequency upper-hybrid wave mode with the dephasing of local cyclotron dynamics. The quantitative real-space characterizations of the non-equilibrium plasma systems demonstrate the feasibilities of a new microscope system in studying the plasma dynamics or transient electric fields with high spatiotemporal resolutions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser Ablation Plasmas and Spectroscopy for Nuclear Applications

The development of measurement methodologies to detect and monitor nuclear-relevant materials remains a consistent and significant interest across the nuclear energy, nonproliferation, safeguards, and forensics communities. Optical spectroscopy of laser-produced plasmas is becoming an increasingly popular diagnostic technique to measure radiological and nuclear materials in the field without sample preparation, where current capabilities encompass the standoff, isotopically resolved and phase-identifiable (e.g., UO and UO[Formula: see text]) detection of elements across the periodic table. These methods rely on the process of laser ablation (LA), where a high-powered pulsed laser is used to excite a sample (solid, liquid, or gas) into a luminous microplasma that rapidly undergoes de-excitation through the emission of electromagnetic radiation, which serves as a spectroscopic fingerprint for that sample. This review focuses on LA plasmas and spectroscopy for nuclear applications, covering topics from the wide-area environmental sampling and atmospheric sensing of radionuclides to recent implementations of multivariate machine learning methods that work to enable the real-time analysis of spectrochemical measurements with an emphasis on fundamental research and development activities over the past two decades. Background on the physical breakdown mechanisms and interactions of matter with nanosecond and ultrafast laser pulses that lead to the generation of laser-produced microplasmas is provided, followed by a description of the transient spatiotemporal plasma conditions that control the behavior of spectroscopic signatures recorded by analytical methods in atomic and molecular spectroscopy. High-temperature chemical and thermodynamic processes governing reactive LA plasmas are also examined alongside investigations into the condensation pathways of the plasma, which are believed to serve as chemical surrogates for fallout particles formed in nuclear fireballs. Laser-supported absorption waves and laser-induced shockwaves that accompany LA plasmas are also discussed, which could provide insights into atmospheric ionization phenomena from strong shocks following nuclear detonations. Furthermore, the standoff detection of trace radioactive aerosols and fission gases is reviewed in the context of monitoring atmospheric radiation plumes and off-gas streams of molten salt reactors. Finally, concluding remarks will present future outlooks on the role of LA plasma spectroscopy in the nuclear community.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Collaborative Research: Unravelling the Physics Associated with the Production of Extremely Dense Plasma States of Microscale (Final Report) Nanosecond-pulsed Discharges

The aim of this project is to study and establish the physical mechanisms that contribute to the formation of anomalously dense plasmas in high-pressure nanosecond-pulsed discharges. These discharges have a broad range of applications such as plasma-assisted combustion, plasma flow actuators, biomedical sterilization and exotic materials synthesis. The structure and formation of these discharges, producing high plasma densities of ~10 14 -10 15 cm -3 , are well-studied and understood. Fast-pulsed microscale high-pressure discharges can be driven to even higher densities of > 10 19 cm -3 , approaching warm dense matter conditions. The mechanisms that generate these plasmas have not been understood. Analysis of the warm dense matter state under laboratory conditions is an expensive and non-trivial endeavor. For instance, dense plasmas can be generated by electrical explosions of metal foils and wires. Plasmas generated after the explosion have a short lifetime and often present difficult conditions for diagnostics. Generation of dense plasmas was also achieved during high-voltage nanosecond pulsed discharges when the so-called explosive electron emission is obtained. Unfortunately, this process is very difficult to control for the studies of warm dense matter. In our recent study, we have shown that additional heating of plasma by lasers can further increase the density of plasma and even lead to the fully ionized state. This method, potentially, allows better control of the plasma parameters. In this work, we studied a second stage laser-heated micro-discharge using a self-consistent one-dimensional particle-in-cell Monte Carlo-collision (1D PIC-MCC) model coupled with Maxwell’s equations. We predicted the generation of a fully ionized plasma on the picosecond time scale. However, this model considered the plasma as an ideal gas despite the high pressure and the nearly fully ionized state. The ideal plasma model assumes that the dilute gas approximation is valid, where the inter-particle interactions are negligible. For charged particles this assumption holds as long as the shielded Coulomb potential assumption is valid. For very high plasma densities, this concept breaks down since the Debye sphere surrounding each charged particle no longer contains enough electrons to statistically provide the shielding of the single particle Coulomb interaction potential. At such densities, the plasma can no longer be described as ideal and non-ideal coupling effects need to be considered. In this report, we elucidate our recent work of developing a PIC-MCC model with improvements for non-ideal plasma conditions due to Coulomb coupling at high densities. In particular, we study the interaction of green light radiation and a dense microplasma, and explore the non-ideal plasma effects in this interaction. In this computational model, we implement the two most important non-ideal effects: ionization potential depression (IPD) and enhanced collision cross sections. Our primary goal is to study the physics associated with electromagnetic (EM) wave heating, also called the second-stage wave-heating, and establish the role of plasma non-ideality in this phenomenon. Our secondary goal is to improve the chemistry mechanism of the 1D PIC-MCC model by including a more detailed excited species collision treatment. At high pressures, stepwise ionization from excited species might play an important role in the ionization process. Previously, this ionization mechanism was neglected due to the excitation collision cross section of xenon being smaller than that of ionization. However, a preliminary study showed that the excited species density in the initial microplasma was an order of magnitude higher than the electron density. Therefore, my aim is to determine the significance of this additional ionization pathway to the plasma generation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Round Robin Analysis of Uranium Isotopics on Cotton Swipes Measured Using Microextraction-Based Sampling Versus Conventional Bulk Analysis

A comparison of microextraction sampling methods to directly analyze uranium isotopics on cotton swipes was performed concurrently with traditional bulk-processing methods. For the microextraction sampling approach, two different detection platforms were evaluated, a quadrupole-based inductively coupled plasma mass spectrometer (ICP-MS) and the liquid sampling-atmospheric pressure glow discharge (LS-APGD) coupled to an Orbitrap mass spectrometer. Results presented from this innovative sampling approach (i.e., microextraction) are compared with a more traditional approach employed for analysis of cotton-based environmental swipes, namely bulk ashing/digestion, separation, and subsequent analysis by high-precision multi-collector ICP-MS. Overall, the microextraction approach proved to be a reliable and accurate means to determine isotopic ratios of uranium collected on cotton swipes. The ICP-MS-based detection had relative standard deviations of <0.65% for the major isotopic determinations, whereas the LS-APGD-Orbitrap method had relative standard deviations of <3%. The percent relative difference for the 235 U/ 238 U ratios, in comparison to the expected values, was <1% for ICP-MS and <4% for the microplasma-Orbitrap method. Additionally, the microextraction ICP-MS accurately (<2%) and precisely (<5%) determined the minor isotopic compositions (i.e., 234 U/ 238 U and 236 U/ 238 U).

ICP-MS↗

Initial Characterization and Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Orbitrap Mass Spectrometer for the Determination of Plutonium

Plutonium measurements are essential to the nuclear forensics and safeguards community. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled with an Orbitrap mass spectrometer is a proven platform for uranium isotope ratio determinations. Here, this work expands the LS-APGD-Orbitrap platform capabilities by reporting the first-ever analysis of plutonium with the LS-APGD and the first-ever measurement of elemental plutonium with an Orbitrap mass spectrometer. This coupling has the potential to dramatically reduce the complex sample manipulations required for traditional analysis techniques employed for actinide isotope ratio determinations. As a first step toward the goal of simultaneous uranium and plutonium isotope ratio determinations, the initial characterization and optimization of the platform for the detection of plutonium are reported. Collision-induced dissociation modality settings were optimized to reduce water-related and other molecular clusters containing plutonium, maximizing 242 Pu 16 O 2 + responses. A design of experiments study was conducted to optimize the discharge conditions of the dual-electrode LS-APGD toward the responsivity of 242 Pu 16 O 2 +. The measurement sensitivity was determined from a Pu response curve, yielding a limit of detection of 10 fg (absolute) of total analyte when data was collected and processed with a Spectroswiss FTMS Booster X2 data acquisition system. Additionally, plutonium and uranium were measured in a simultaneous acquisition, and each analyte remained unaffected by the other. It is believed that the LS-APGD-Orbitrap platform could be a valuable addition to the nuclear forensics’ toolbox and, indeed, other scientific disciplines and regulatory communities in which rapid, high-resolution plutonium determinations are paramount.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Transition characteristics and electron kinetics in microhollow cathode discharges

We demonstrate the transition characteristics and electron kinetics of microdischarges in a microgap with a cathode having microstructures using two-dimensional particle-in-cell/Monte Carlo collision (2d3v) simulations. It is found that the microdischarge is inside the hollow cavity at lower pressures, forming microhollow cathode discharges (MHCDs), while the dominant discharge moves outside the cavity at higher pressures, locating above the cathode rectangular protrusion tip. The spatial distributions of the microdischarge parameters (e.g., electric potential and electron density) are presented by capturing the transition characteristics. The electron kinetics of the microdischarges are examined based on the moment analysis of the electron Boltzmann equation. The collisional and non-collisional components of the electron power absorption are decomposed, which were seldomly investigated for microdischarges previously. The results provide fundamental insights into MHCD formation with a structured electrode at varying pressure conditions, which could be beneficial for the design and fabrication of microplasma devices in practical applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Combined microwave and laser Rayleigh scattering diagnostics for pin-to-pin nanosecond discharges

In this work, the temporal decay of electrons produced by an atmospheric pin-to-pin nanosecond discharge operating in the spark regime was measured via a combination of microwave Rayleigh scattering (MRS) and laser Rayleigh scattering (LRS). Due to the initial energy deposition of the nanosecond pulse, a variation in the local gas density occurs on the timescale of electron decay. Thus, the assumption of a constant collisional frequency is no longer applicable when electron number data are extracted from MRS measurements. Furthermore, to recalibrate MRS measurements throughout the electron decay period, temporally resolved LRS measurements of the local gas density were performed over the event duration. The local gas density was calculated to be 30% of the ambient level during the later stages of electron decay, and it recovers at about 1 ms after discharge. A shock front traveling approximately 500 m/s was additionally observed. Coupled with plasma volume calibration via temporally resolved intensified charge-coupled device imaging, the corrected decay curves of the electron number and electron number density are presented with a measured peak electron number density of 4.5 × 1015 cm -3 and a decay rate of ~(0.1–0.35) × 10 7 s -1 . A hybrid MRS and LRS diagnostic technique can be applied for a broad spectrum of atmospheric-pressure microplasmas where a variation in the gas number density is expected due to energy deposition in the discharge.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗