Design and Development of a Miniaturized Double Latching Solenoid Valve for the Sample Analysis at Mars Instrument Suite

The development of the in-house Miniaturized Double Latching Solenoid Valve, or Microvalve, for the Gas Processing System (GPS) of the Sample Analysis at Mars (SAM) instrument suite is described. The Microvalve is a double latching solenoid valve that actuates a pintle shaft axially to hermetically seal an orifice. The key requirements and the design innovations implemented to meet them are described.

Smith, James T.↗

NASA Tech Briefs, December 2003

Topics covered include: Organic/Inorganic Hybrid Polymer/Clay Nanocomposites; Less-Toxic Coatings for Inhibiting Corrosion of Aluminum; Liquid Coatings for Reducing Corrosion of Steel in Concrete; Processable Polyimides Containing APB and Reactive End Caps; Rod/Coil Block Copolyimides for Ion-Conducting Membranes; Techniques for Characterizing Microwave Printed Antennas; Cylindrical Antenna With Partly Adaptive Phased-Array Feed; Command Interface ASIC - Analog Interface ASIC Chip Set; Predicting Accumulations of Ice on Aerodynamic Surfaces; Analyzing Aeroelasticity in Turbomachines; Software for Allocating Resources in the Deep Space Network; Expert Seeker; High-Speed Recording of Test Data on Hard Disks; Functionally Graded Nanophase Beryllium/Carbon Composites; Thin Thermal-Insulation Blankets for Very High Temperatures; Aerostructures Test Wing; Flight-Test Evaluation of Flutter-Prediction Methods; Piezoelectrically Actuated Microvalve for Liquid Effluents; Larger-Stroke Piezoelectrically Actuated Microvalve; Innovative, High-Pressure, Cryogenic Control Valve: Short Face-to-Face, Reduced Cost; Safer Roadside Crash Walls Would Limit Deceleration; Improved Interactive Medical-Imaging System; Scanning Microscopes Using X Rays and Microchannels; Slotting Fins of Heat Exchangers to Provide Thermal Breaks; Methane Clathrate Hydrate Prospecting; Automated Monitoring with a BSP Fault-Detection Test; Automated Monitoring with a BCP Fault-Decision Test; Vector-Ordering Filter Procedure for Data Reduction; Remote Sensing and Information Technology for Large Farms; Developments at the Advanced Design Technologies Testbed; Spore-Forming Bacteria that Resist Sterilization; and Acoustical Applications of the HHT Method.

Source record↗

Novel volumetric method for highly repeatable injection in microchip electrophoresis

A novel injector for microchip electrophoresis (MCE) has been designed and evaluated that achieves very high repeatability of injection volume suitable for quantitative analysis. It eliminates the injection biases in electrokinetic injection and the dependence on pressure and sample properties in hydrodynamic injection. The microfluidic injector, made of poly(dimethylsiloxane) (PDMS), operates similarly to an HPLC injection valve. It contains a channel segment (chamber) with a well-defined volume that serves as an “injection loop”. Using on-chip microvalves, the chamber can be connected to the sample source during the “loading” step, and to the CE separation channel during the “injection” step. Once the valves are opened in the second state, electrophoretic potential is applied to separate the sample. For evaluation and demonstration purposes, the microinjector was connected to a 75 μm ID capillary and UV absorbance detector. For single compounds, a relative standard deviation (RSD) of peak area as low as 1.04% (n = 11) was obtained, and for compound mixtures, RSD as low as 0.40% (n = 4) was observed. Using the same microchip, the performance of this new injection technique was compared to hydrodynamic injection and found to have improved repeatability and less dependence on sample viscosity. Furthermore, a non-radioactive version of the positron-emission tomography (PET) imaging probe, FLT, was successfully separated from its known 3 structurally-similar byproducts with baseline resolution, demonstrating the potential for rapid, quantitative analysis of impurities to ensure the safety of batches of short-lived radiotracers. Both the separation efficiency and injection repeatability were found to be substantially higher when using the novel volumetric injection approach compared to electrokinetic injection (performed in the same chip). This novel microinjector provides a straightforward way to improve the performance of hydrodynamic injection and enables extremely repeatable sample volume injection in MCE. It could be used in any MCE application where volume repeatability is needed, including the quantitation of impurities in pharmaceutical or radiopharmaceutical samples.

60 APPLIED LIFE SCIENCES↗

Microscopic Gas-Flow Controller

Proposed flow-controlling and -measuring device made by batch solid-state microelectronic-fabrication techniques. Device contains ultrasensitive silicon capacitive pressure transducer, gas-flow channels etched in silicon wafer, and integrated microvalves. Used to control and monitor low gas flows at low pressures.

Wise, Kensall D.↗

Liquid metal micro heat pipes for space radiator applications

Micromachining is a chemical means of etching three-dimensional structures, typically in single-crystalline silicon. These techniques are leading toward what is coming to be referred to as MEMS (micro electro mechanical systems), where in addition to the ordinary two dimensional (planar) microelectronics, it is possible to build three-dimensional micromotors, electrically-actuated microvalves, hydraulic systems, and much more on the same microchip. These techniques become possible because of differential etching rates of various crystallographic planes and materials used for semiconductor microfabrication. The University of Cincinnati group in collaboration with NASA Lewis formed micro heat pipes in silicon by the above techniques. Work is ongoing at a modest level, but several essential bonding and packaging techniques have been recently developed. Currently, we have constructed and filled water/silicon micro heat pipes. Preliminary thermal tests of arrays of 125 micro heat pipes etched in a 1 inch x 1 inch x 250 micron silicon wafer have been completed. These pipes are instrumented with extremely small P-N junctions to measure their effective conductivity and their maximum operating power. A relatively simple one-dimensional model has been developed in order to predict micro heat pipes' operating characteristics. This information can be used to optimize micro heat pipe design with respect to length, hydraulic diameter, and number of pipes. Work is progressing on the fabrication of liquid-metal micro heat pipes. In order to be compatible with liquid metal (sodium or potassium), the inside of the micro heat pipes will be coated with a refractory metal (such as tungsten, molybdenum, or titanium).

Gerner, F. M.↗

Low-power piezoelectric micro-machined valve

A piezoelectric microvalve employs a valve element formed of hermetically sealed and opposed plates flexed together by a cross axis piezoelectric element. Large flow modulation with small piezoelectric actuator displacement is obtained by perimeter augmentation of the valve seat which dramatically increases the change in valve flow area for small deflections.

Gianchandani, Yogesh B.↗

NASA Tech Briefs, January 2001

The topics include: 1) A "Model" of Interactive Engineering; 2) Feature Section: Communications Technology; 3) lnReview; 4) Application Briefs; 5) Submillimeter-Wave Image Sensor; 6) Ultrasonic/Sonic Drill/Corers With Integrated Sensors; 7) Normally Closed, Piezoelectrically Actuated Microvalve; 8) Magnetostrictively Actuated Valves for Cryosurgical Probes; 9) Remote Sensing of Electric Fields in Clouds; 10) Wireless-Communication Headset Subsystem To Enhance Signaling; 11) Power Amplifier With 9 to 13 dB of Gain From 65 to 146 GHz; 12) Humidity Interlock for Protecting a Cooled Laser Crystal; 13) A Lightweight Ambulatory Physiological Monitoring System; 14) Improvements in a Lightning-Measuring Instrument; 15) Broad-Band, Noninvasive Radio-Frequency Current Probe; 16) Web-Based Technology Distributes Lean Models; 17) Software Guides Aeroelastic-Systems Design; and 18) Postprocessing Software for Micromechanics Analysis Code. A Photonics West 2001 Preview Tech Brief supplement to this January 2001 issue is also included.

Source record↗

NASA Tech Briefs, September 2004

Topics covered include: Brazing SiC/SiC Composites to Metals; Composite-Material Tanks with Chemically Resistant Liners; Thermally Conductive Metal-Tube/Carbon-Composite Joints; Improved BN Coatings on SiC Fibers in SiC Matrices; Iterative Demodulation and Decoding of Non-Square QAM; Measuring Radiation Patterns of Reconfigurable Patch Antennas on Wafers; Low-Cutoff, High-Pass Digital Filtering of Neural Signals; Further Improvement in 3DGRAPE; Ground Support Software for Spaceborne Instrumentation; MER SPICE Interface; Simulating Operation of a Planetary Rover; Analyzing Contents of a Computer Cache; Discrepancy Reporting Management System; Silicone-Rubber Microvalves Actuated by Paraffin; Hydraulic Apparatus for Mechanical Testing of Nuts; Heat Control via Torque Control in Friction Stir Welding; Manufacturing High-Quality Carbon Nanotubes at Lower Cost; Setup for Visual Observation of Carbon-Nanotube Arc Process; Solution Preserves Nucleic Acids in Body-Fluid Specimens; Oligodeoxynucleotide Probes for Detecting Intact Cells; Microwave-Spectral Signatures Would Reveal Concealed Objects; Digital Averaging Phasemeter for Heterodyne Interferometry; Optoelectronic Instrument Monitors pH in a Culture Medium; Imaging of gamma-Irradiated Regions of a Crystal; Photodiode-Based, Passive Ultraviolet Dosimeters; Discrete Wavelength-Locked External Cavity Laser; Flexible Shields for Protecting Spacecraft Against Debris; Part 2 of a Computational Study of a Drop-Laden Mixing Layer; Controllable Curved Mirrors Made from Single-Layer EAP Films; and Demonstration of a Pyrotechnic Bolt-Retractor System.

Source record↗

Blood monitoring systems and methods thereof

A blood monitoring system is capable of monitoring the blood of a subject in vivo. The blood monitoring system comprises: 1) an array of movable microneedle micromachined within associated wells; 2) array of motion actuators able to move each needle in and out of their associated wells; 3) array of microvalves associated with each microneedle able to control the flow of air around the microneedle; 4) an array of chemical sensors inserted into patient by movable microneedles; 5) an array of inductors able to measure chemical concentration in the vicinity of inserted chemical sensors; 6) conducting vias that provide timed actuating signal signals from a control system to each motion actuator; 7) conducting vias that transmit signal produced by array of chemical sensors to the control system for processing, although the blood monitoring system can comprise other numbers and types of elements in other configurations.

Mir, Jose↗

20-mN Variable Specific Impulse (Isp) Colloid Thruster

Busek Company, Inc., has designed and manufactured an electrospray emitter capable of generating 20 mN in a compact package (7x7x1.7 in). The thruster consists of nine porous-surface emitters operating in parallel from a common propellant supply. Each emitter is capable of supporting over 70,000 electrospray emission sites with the plume from each emitter being accelerated through a single aperture, eliminating the need for individual emission site alignment to an extraction grid. The total number of emission sites during operation is expected to approach 700,000. This Phase II project optimized and characterized the thruster fabricated during the Phase I effort. Additional porous emitters also were fabricated for full-scale testing. Propellant is supplied to the thruster via existing feed-system and microvalve technology previously developed by Busek, under the NASA Space Technology 7's Disturbance Reduction System (ST7-DRS) mission and via follow-on electric propulsion programs. This project investigated methods for extending thruster life beyond the previously demonstrated 450 hours. The life-extending capabilities will be demonstrated on a subscale version of the thruster.

Demmons, Nathaniel↗

Bidirectional shape memory device

A resistively heated shape memory polymer device is operated using resistive heating to heat the shape memory polymer device. The resistively heated shape memory polymer device is made by providing a wire that includes a resistive medium. The wire is coated with a first shape memory polymer. The wire is exposed and electrical leads are attached to the wire. In one embodiment the shape memory polymer device is in the form of a clot destruction device. In another embodiment the shape memory polymer device is in the form of a microvalve. In another embodiment the shape memory polymer device is in the form of a micropump. In yet another embodiment the shape memory polymer device is in the form of a thermostat or relay switch.

36 MATERIALS SCIENCE↗

Bidirectional shape memory device

A resistively heated shape memory polymer device is operated using resistive heating to heat the shape memory polymer device. The resistively heated shape memory polymer device is made by providing a wire that includes a resistive medium. The wire is coated with a first shape memory polymer. The wire is exposed and electrical leads are attached to the wire. In one embodiment the shape memory polymer device is in the form of a clot destruction device. In another embodiment the shape memory polymer device is in the form of a microvalve. In another embodiment the shape memory polymer device is in the form of a micropump. In yet another embodiment the shape memory polymer device is in the form of a thermostat or relay switch.

Marion, III, John E.↗

Development of a Micro-Isolation Valve

A feasibility investigation for a newly proposed microfabricated, normally-closed isolation valve was initiated.

Microvalves microspacecraft micropropulsion micro-↗