Search NASA⌕ Search

SEARCH · Search NASA

Results for “mobile visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Integration for navigation on the UMASS mobile perception lab

Integration of real-time visual procedures for use on the Mobile Perception Lab (MPL) was presented. The MPL is an autonomous vehicle designed for testing visually guided behavior. Two critical areas of focus in the system design were data storage/exchange and process control. The Intermediate Symbolic Representation (ISR3) supported data storage and exchange, and the MPL script monitor provided process control. Resource allocation, inter-process communication, and real-time control are difficult problems which must be solved in order to construct strong autonomous systems.

Draper, Bruce↗

Distributed Visual Sensing and Fusion for Advanced Air Mobility

Surveillance solutions for Advanced and Urban Air Mobility frameworks are a key factor to enable safe operations of highly automated aircraft in the civil airspace. To design solutions suitable for all types of aircraft, non-cooperative sensors can be used, though many challenges arise when the small dimensions of the vehicles and their proximity to the ground during low-altitude missions are considered. A distributed sensing concept can be efficiently applied to address these challenges by exploiting multiple sensors within a surveillance network. This paper proposes a strategy to fuse the information collected by three ground-fixed cameras within a network of multiple distributed sensors and is tested with during experimental flight tests. The solution exploits standalone tracking estimates of each camera within a fusion center that performs triangulation and three-dimensional tracking. This approach is tested in a scenario involving two small UAVs flying at low altitude. The paper deals with the challenges of associating the two objects from independent and unrelated tracks to achieve robust triangulation, which produces meter-level mean errors with respect to GNSS-based ground truth.

Federica Vitiello↗

Bringing chemical structures to life with augmented reality, machine learning, and quantum chemistry

Visualizing 3D molecular structures is crucial to understanding and predicting their chemical behavior. However, static 2D hand-drawn skeletal structures remain the preferred method of chemical communication. Here, we combine cutting-edge technologies in augmented reality (AR), machine learning, and computational chemistry to develop MolAR, an open-source mobile application for visualizing molecules in AR directly from their hand-drawn chemical structures. Users can also visualize any molecule or protein directly from its name or protein data bank ID and compute chemical properties in real time via quantum chemistry cloud computing. MolAR provides an easily accessible platform for the scientific community to visualize and interact with 3D molecular structures in an immersive and engaging way.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LC-IM-TOF Instrument Control & Data Visualization Software

Liquid Chromatography-Ion Mobility-time of Flight Instrument Control and Data Visualization software is designed to control instrument voltages for the Ion Mobility drift tube. It collects and stores information collected from the Agilent TOF instrument and analyses/displays the ion intensity information acquired. The software interface can be split into 3 categories -- Instrument Settings/Controls, Data Acquisition, and Viewer. The Instrument Settings/Controls prepares the instrument for Data Acquisition. The Viewer contains common objects that are used by Instrument Settings/Controls and Data Acquisition. Intensity information is collected in 1 nanosec bins and separated by TOF pulses called scans. A collection of scans are stored side by side making up an accumulation. In order for the computer to keep up with the stream of data, 30-50 accumulations are commonly summed into a single frame. A collection of frames makes up an experiment. The Viewer software then takes the experiment and presents the data in several possible ways, each frame can be viewed in TOF bins or m/z (mass to charge ratio). The experiment can be viewed frame by frame, merging several frames, or by viewing the peak chromatogram. The user can zoom into the data, export data, and/or animate frames. Additional features include calibration of the data and even post-processing multiplexed data.

Danielson III, WilliamF.↗

High-Performance 3D Articulated Robot Display

In the domain of telerobotic operations, the primary challenge facing the operator is to understand the state of the robotic platform. One key aspect of understanding the state is to visualize the physical location and configuration of the platform. As there is a wide variety of mobile robots, the requirements for visualizing their configurations vary diversely across different platforms. There can also be diversity in the mechanical mobility, such as wheeled, tracked, or legged mobility over surfaces. Adaptable 3D articulated robot visualization software can accommodate a wide variety of robotic platforms and environments. The visualization has been used for surface, aerial, space, and water robotic vehicle visualization during field testing. It has been used to enable operations of wheeled and legged surface vehicles, and can be readily adapted to facilitate other mechanical mobility solutions. The 3D visualization can render an articulated 3D model of a robotic platform for any environment. Given the model, the software receives real-time telemetry from the avionics system onboard the vehicle and animates the robot visualization to reflect the telemetered physical state. This is used to track the position and attitude in real time to monitor the progress of the vehicle as it traverses its environment. It is also used to monitor the state of any or all articulated elements of the vehicle, such as arms, legs, or control surfaces. The visualization can also render other sorts of telemetered states visually, such as stress or strains that are measured by the avionics. Such data can be used to color or annotate the virtual vehicle to indicate nominal or off-nominal states during operation. The visualization is also able to render the simulated environment where the vehicle is operating. For surface and aerial vehicles, it can render the terrain under the vehicle as the avionics sends it location information (GPS, odometry, or star tracking), and locate the vehicle over or on the terrain correctly. For long traverses over terrain, the visualization can stream in terrain piecewise in order to maintain the current area of interest for the operator without incurring unreasonable resource constraints on the computing platform. The visualization software is designed to run on laptops that can operate in field-testing environments without Internet access, which is a frequently encountered situation when testing in remote locations that simulate planetary environments such as Mars and other planetary bodies.

Powell, Mark W.↗

A Visual Analytic Platform for Interactive Validation of Human Mobility Simulations

Human mobility insights guide domain experts in an array of decisions, including critical infrastructure design, disaster response, epidemic modeling, national security, and policy making. Due to the inherent noise and privacy concerns in real-world individual-level mobility data, it is often preferred to leverage simulators that generate synthetic mobility data instead. However, it is critical to inspect and validate the output of such simulators to ensure the synthetic data is aligned with the characteristics of the population and the area of interest known to domain experts. While there exist many quantitative approaches for validating synthetic data, we argue it is also important to also validate such data qualitatively to capture aspects that are known to domain experts but difficult to quantify. In this work, we demonstrate a visual analytic platform that empowers domain experts to interact with their simulation outputs along spatial and temporal dimensions. By augmenting automated techniques and human skills, our visual analytic platform is a step towards interactive capabilities for model steering and quality control of mobility simulators.

Monadjemi, Shayan↗

SU-F-P-59: Detection of Missing Surgical Needles with Intraoperative Mobile X-Ray

Purpose: To determine the minimal detectable size of a surgical needle using intraoperative mobile x-ray imaging. Also, varying techniques such as low kVp and high tube current were tested to investigate whether this improved the detection of the various needle sizes. Methods: Seven surgical needle sizes, 6.5, 8, 11, 13, 16, 17 and 19 mm, were positioned on three regions (thoracic, abdominal and pelvic) of an adult size anthropomorphic RANDO phantom. The phantom represents an average size adult. The phantom, in front of detector, was imaged with 44” x-ray tube to detector distance. For the thoracic region, each needle size was imaged 4 times using the following technique (81 kVp at 32 mAs and 200 mAs; then 100 kVp at 32 mAs and 200 mAs. This was repeated for the abdominal and pelvic regions of the phantom. The images were reviewed by a board certified diagnostic radiologist. Results: The surgical needles sized 13 mm and above were visible at all three body regions using all four kVp and mAs combinations. For surgical needle sizes 8 and 11 mm, the visibility of needle was ambiguous in thoracic region and barely visible abdominal and pelvic regions. Surgical needles, with size smaller than 8 mm, could not be visualized on x-ray with unassisted eyesight. The detectability of the smaller sized needles was not improved with increasing mAs or decreasing kVp. Conclusion: Surgical needle sizes less that 13 mm were not visualized with intraoperative mobile x-ray imaging using various mAs and kVp combinations. Intraoperative mobile x-ray is not recommended to locate surgical needle sizes less than 13 mm for the following reasons: (1) it prevents unnecessary radiation exposure to patient, (2) it avoids the delay time with wound closure and completion of the operative procedure, and (3) it saves radiologist reading time.

60 APPLIED LIFE SCIENCES↗

Economic impact of stimulated technological activity. Part 3: Case study, knowledge additions and earth links from space crew systems

A case study of knowledge contributions from the crew life support aspect of the manned space program is reported. The new information needed to be learned, the solutions developed, and the relation of new knowledge gained to earthly problems were investigated. Illustrations are given in the following categories: supplying atmosphere for spacecraft; providing carbon dioxide removal and recycling; providing contaminant control and removal; maintaining the body's thermal balance; protecting against the space hazards of decompression, radiation, and meteorites; minimizing fire and blast hazards; providing adequate light and conditions for adequate visual performance; providing mobility and work physiology; and providing adequate habitability.

Source record↗

Biomedical technology transfer. Applications of NASA science and technology

Ongoing projects described address: (1) intracranial pressure monitoring; (2) versatile portable speech prosthesis; (3) cardiovascular magnetic measurements; (4) improved EMG biotelemetry for pediatrics; (5) ultrasonic kidney stone disintegration; (6) pediatric roentgen densitometry; (7) X-ray spatial frequency multiplexing; (8) mechanical impedance determination of bone strength; (9) visual-to-tactile mobility aid for the blind; (10) Purkinje image eyetracker and stabilized photocoalqulator; (11) neurological applications of NASA-SRI eyetracker; (12) ICU synthesized speech alarm; (13) NANOPHOR: microelectrophoresis instrument; (14) WRISTCOM: tactile communication system for the deaf-blind; (15) medical applications of NASA liquid-circulating garments; and (16) hip prosthesis with biotelemetry. Potential transfer projects include a person-portable versatile speech prosthesis, a critical care transport sytem, a clinical information system for cardiology, a programmable biofeedback orthosis for scoliosis a pediatric long-bone reconstruction, and spinal immobilization apparatus.

Harrison, D. C.↗

Human operator performance of remotely controlled tasks: Teleoperator research conducted at NASA's George C. Marshall Space Flight Center. Executive summary

The combination of human and machine capabilities into an integrated engineering system which is complex and interactive interdisciplinary undertaking is discussed. Human controlled remote systems referred to as teleoperators, are reviewed. The human factors requirements for remotely manned systems are identified. The data were developed in three principal teleoperator laboratories and the visual, manipulator and mobility laboratories are described. Three major sections are identified: (1) remote system components, (2) human operator considerations; and (3) teleoperator system simulation and concept verification.

Shields, N., Jr.↗

Enabling Real-Time Volume Rendering of Functional Magnetic Resonance Imaging on an iOS Device

Powerful non-invasive imaging technologies like computed tomography (CT), ultrasound, and magnetic resonance imaging (MRI) are used daily by medical professionals to diagnose and treat patients. While 2D slice viewers have long been the standard, many tools allowing 3D representations of digital medical data are now available. The newest imaging advancement, functional MRI (fMRI) technology, has changed medical imaging from viewing static to dynamic physiology (4D) over time, particularly to study brain activity. Add this to the rapid adoption of mobile devices for everyday work and the need to visualize fMRI data on tablets or smartphones arises. However, there are few mobile tools available to visualize 3D MRI data, let alone 4D fMRI data. Building volume rendering tools on mobile devices to visualize 3D and 4D medical data is challenging given the limited computational power of the devices. This paper describes research that explored the feasibility of performing real-time 3D and 4D volume raycasting on a tablet device. The prototype application was tested on a 9.7” iPad Pro using two different fMRI datasets of brain activity. The results show that mobile raycasting is able to achieve between 20 and 40 frames per second for traditional 3D datasets, depending on the sampling interval, and up to 9 frames per second for 4D data. While the prototype application did not always achieve true real-time interaction, these results clearly demonstrated that visualizing 3D and 4D digital medical data is feasible with a properly constructed software framework.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

What’s in Your Pocket? Trends in Mobile Apps for Biosurveillance and Decision-Making

Mobile applications offer tremendous potential for collecting data for biosurveillance through participatory surveillance and the integration of new and traditional data streams. This panel features epidemiologists, data scientists, and technology partners who will address the full application lifecycle -- from the assessment of the specific demand, resource, and technology specifications, to implementation and evaluation-- of several innovative apps. Audience engagement using a new web app will gather input on other uses of mobile apps for data collection, visualization, and analyses. The panel and audience discussion will be compiled into guidance for future development of mobile apps for biosurveillance purposes to advance population health.

60 APPLIED LIFE SCIENCES↗

Assessing Performance of Radar and Visual Sensing Techniques for Ground-To-Air Surveillance in Advanced Air Mobility

The safe integration of Unmanned Aircraft Vehicles (UAV) within the civil airspace is of great interest to NASA’s Advanced Air Mobility project, which envisions high density of operations in and around urban areas that include both UAV and AAM aircraft. To enable safe autonomous operations of both platforms, reliable airspace surveillance strategies must be designed and experimentally validated in relevant scenarios, where multiple small UAV operate flying in low altitude conditions. An example of such a scenario is described in this paper which provides performance assessment of various sensing strategies experimentally tested during flight campaigns with four UAV completing simultaneous missions from vertiports. Such campaigns are performed by the High Density Vertiplex subproject which assesses a prototype of Urban Air Mobility ecosystem. For the purposes of this work, the flights are observed from multiple sensing nodes each with radar and camera sensors. The visual detection and tracking algorithms achieved 96.1% to 99.9% average tracking coverage of the UAV above the horizon, reaching detection ranges larger than 1 kilometer for octocopter. Radar-based tracking shows a lower coverage mainly due to ground clutter removal challenges but provides comparable detection ranges and meter-level range accuracy.

Federica Vitiello↗

[18F]-Fluoromisonidazole Positron Emission Tomography/Computed Tomography Visualization of Tumor Hypoxia in Patients With Chordoma of the Mobile and Sacrococcygeal Spine

Purpose: To investigate [18F]-fluoromisonidazole positron emission tomography/computed tomography (FMISO-PET/CT) detection of targetable hypoxic subvolumes (HSVs) in chordoma of the mobile or sacrococcygeal spine. Methods and Materials: A prospective, pilot study of 20 patients with primary or locally recurrent chordoma of the mobile or sacrococcygeal spine treated with proton or combined proton/photon radiation therapy (RT) with or without surgery was completed. The FMISO-PET/CT was performed before RT and after 19.8-34.2 GyRBE (relative biologic effectiveness). Gross tumor volumes were delineated and HSVs defined including voxels with standardized uptake values ≥1.4 times the muscle mean. Clinical characteristics and treatments received were compared between patients with and without HSVs. Results: The FMISO-PET/CT detected HSVs in 12 of 20 patients (60%). Baseline and interval HSV spatial concordance varied (0%-94%). Eight HSVs were sufficiently large (≥5 cm{sup 3}) to potentially allow an intensity modulated proton therapy boost. Patients with HSVs had significantly larger gross tumor volumes (median 410.0 cm{sup 3} vs 63.4 cm{sup 3}; P=.02) and were significantly more likely to have stage T2 tumors (5 of 12 vs 0 of 8; P=.04). After a median follow-up of 1.8 years (range, 0.2-4.4 years), a local recurrence has yet to be observed. Three patients developed metastatic disease, 2 with HSVs. Conclusions: Detection of targetable HSVs by FMISO-PET/CT within patients undergoing RT with or without surgery for treatment of chordoma of the mobile and sacrococcygeal spine is feasible. The study's inability to attribute interval HSV changes to treatment, rapidly changing hypoxic physiology, or imaging inconsistencies is a limitation. Further study of double-baseline FMISO-PET/CT and hypoxia-directed RT dose escalation, particularly in patients at high risk for local recurrence, is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scalable Reasoning System (SRS)

SRS is a web-based and mobile toolkit for information visualization and collaboration. It includes server-side components in the form of web services that provide analytical functions such as data clustering and temporal analysis. The SRS client is accessed via a web browser and uses asynchronous javascript and XML (AJAX) to interact with and visualize the results of these web services. Users of SRS can query data sources that are connected to the SRS backend, and query results are presented in the form of coordinated visual displays in a web browser that depict temporal, topical, and spatial relationships in the results. SRS also includes an early stage graphical reasoning diagram interface that helps analysts express and test hypotheses. This software was developed with funding from the Science and Technology Directorate of the U.S. Department of Homeland Security.

Pike, William↗

Satcom systems and technologies into the 21st century

The role of communications satellites in the domestic U.S. telecommunications market for the next 25 years is examined, the focus being on the new satellite communications systems concepts and their enabling technologies. A simple procedure for the identification of critical satellite technologies in the years 2000-2015 is described. Study results indicate that by the year 2015, satellites will find commercial applications in the distribution of space-gathered data, supercomputer network, scientific visualization to remote areas, mobile services, VSAT, broadband ISDN, and data services.

Kwan, Robert K.↗

Vision based object pose estimation for mobile robots

Mobile robot navigation using visual sensors requires that a robot be able to detect landmarks and obtain pose information from a camera image. This paper presents a vision system for finding man-made markers of known size and calculating the pose of these markers. The algorithm detects and identifies the markers using a weighted pattern matching template. Geometric constraints are then used to calculate the position of the markers relative to the robot. The selection of geometric constraints comes from the typical pose of most man-made signs, such as the sign standing vertical and the dimensions of known size. This system has been tested successfully on a wide range of real images. Marker detection is reliable, even in cluttered environments, and under certain marker orientations, estimation of the orientation has proven accurate to within 2 degrees, and distance estimation to within 0.3 meters.

Wu, Annie↗