Search NASA⌕ Search

SEARCH · Search NASA

Results for “mobility diameter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Particle emissions from mobile sources: Discussion of ultrafine particle emissions and definition

There is no universally agreed upon definition for ultrafine particles (UFP). Commonly used definitions for UFP are either particle number below 100 nm or total particle number, but without an agreed upon lower cut point. For example, a lower cut point of 3 nm compared to 10 nm could result in a substantially higher count. Another definition for UFP is total particle mass but without a commonly agreed upon aerodynamic diameter upper cut point, e.g., below 100 nm, 200 nm, 300 nm, etc. Yet another definition is lung deposited surface area weighted by lung deposition fraction, found mainly in the particle mobility diameter range from 20 to 400 nm. It is clear from these definitions that there are inconsistencies in the way UFP is used and defined in the literature. Sometimes these metrics are well correlated, sometimes not. In this paper we suggest three exposure metrics: UFP-N, UFP-M, and UFP-S, that we believe will add clarity. These metrics represent total number, mass, and surface area below 500 nm, respectively. For surface area and mass, the 500 nm cut point can be either aerodynamic or mobility diameter depending upon measurement methodology. For all metrics, this cut point captures nearly all of the primary particle emissions from mobile sources. Furthermore, UFP-N would include a lower cut point of 3–6 nm and would not require an upper size cut point because there is very little particle number above 500 nm or even above 100 nm. Thus, our definition of UFP-N is consistent with the current definition of ultrafine number except for, importantly, the specification of a lower cut point. These exposure metrics can help facilitate consistency in the characterization of both short- and long-term UFP ambient exposures and associated health effects in epidemiological studies.

42 ENGINEERING↗

Efficacy of a portable, moderate-resolution, fast-scanning differential mobility analyzer for ambient aerosol size distribution measurements

Abstract. Ambient aerosol size distributions obtained with a compact scanning mobility analyzer, the “Spider” differential mobility analyzer (DMA), are compared to those obtained with a conventional mobility analyzer, with specific attention to the effect of mobility resolution on the measured size distribution parameters. The Spider is a 12 cm diameter radial differential mobility analyzer that spans the 10–500 nm size range with 30 s mobility scans. It achieves its compact size by operating at a nominal mobility resolution R=3 (sheath flow = 0.9 L min−1; aerosol flow = 0.3 L min−1) in place of the higher ratio of sheath flow to aerosol flow commonly used. The question addressed here is whether the lower resolution is sufficient to capture key characteristics of ambient aerosol size distributions. The Spider, operated at R=3 with 30 s up- and downscans, was co-located with a TSI 3081 long-column mobility analyzer, operated at R=10 with a 360 s sampling duty cycle. Ambient aerosol data were collected over 26 consecutive days of continuous operation, in Pasadena, CA. Over the 17–500 nm size range, the two instruments exhibit excellent correlation in the total particle number concentrations and geometric mean diameters, with regression slopes of 1.13 and 1.00, respectively. Our results suggest that particle sizing at a lower resolution than typically employed may be sufficient to obtain key properties of ambient size distributions, at least for these two moments of the size distribution. Moreover, it enables better counting statistics, as the wider transfer function for a given aerosol flow rate results in a higher counting rate.

54 ENVIRONMENTAL SCIENCES↗

The Robotic All-Terrain Lunar Exploration Rover (RATLER): Increased mobility through simplicity

A new concept mobility chassis for a robotic rover is described which is inherently simple with few moving parts or complex linkages. The RATLER design utilizes a four-wheel drive, skid steered propulsion system in conjunction with passive articulation of the dual body vehicle. This uniquely simple method of chassis articulation allows all four wheels to remain in contact with the ground even while climbing obstacles as large as 1.3 wheel diameters. A prototype mobility platform was built which is approximately 1 m(sup 2) with 0.5 m diameter wheels and all-wheel electric drive. The theoretical mobility limitations are discussed and compared with the results of field trials of the prototype platform. The theoretical model contrasted with measured performance is then used to predict the expected mobility of the RATLER design on the Lunar surface.

Pletta, J. Bryan↗

Fate and transport of unruptured tri-structural isotropic (TRISO) fuel particles in the event of environmental release for advanced and micro reactor applications

Advanced nuclear reactor designs and advanced fuel types offer safety features that may reduce environmental consequences in an accident scenario when compared to conventional reactors and fuels. One advanced reactor fuel is tri-structural isotropic (TRISO) fuel particles which are approximately 0.9 mm in diameter. TRISO particle mobility, assuming the particle is unruptured and the encapsulated radionuclides are contained, was explored through a theoretical examination of mobility through atmospheric, soil and groundwater, surface water, and non-human biota transport pathways. TRISO particles are too large and dense to travel in the atmosphere except under extreme conditions. TRISO particles are too large to penetrate most soil profiles and so cannot be transported with groundwater. TRISO particles will settle out of the water column in surface waters but the transport will depend on the energy of the body of water and likelihood of extreme dispersion events. TRISO particles could be transported by non-human biota. The size of TRISO particles could allow them to be intentionally moved by non-human biota if they are ingested as a gastrolith or if they are mistaken for something in the organism’s diet. Generally, TRISO particles will have reduced environmental mobility compared to releases of radionuclides in the event of an accident in a conventional nuclear reactor. The extent of transport has implications in emergency planning zone designations and other considerations for licensing and deploying TRISO-fueled reactors. Finally, further research and experimental work exploring TRISO particle mobility is required to understand the full environmental mobility of TRISO particles.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hybrid nanocapsules for in situ TEM imaging of gas evolution reactions in confined liquids

Liquid cell transmission electron microscopy (TEM) enables the direct observation of dynamic physical and chemical processes in liquids at the nanoscale. Quantitative investigations into reactions with fast kinetics and/or multiple reagents will benefit from further advances in liquid cell design that facilitate rapid in situ mixing and precise control over reagent volumes and concentrations. This work reports the development of inorganic–organic nanocapsules for high-resolution TEM imaging of nanoscale reactions in liquids with well-defined zeptoliter volumes. These hybrid nanocapsules, with 48 nm average diameter, consist of a thin layer of gold coating a lipid vesicle. As a model reaction, the nucleation, growth, and diffusion of nanobubbles generated by the radiolysis of water is investigated inside the nanocapsules. When the nanobubbles are sufficiently small (10–25 nm diameter), they are mobile in the nanocapsules, but their movement deviates from Brownian motion, which may result from geometric confinement by the nanocapsules. Gases and fluids can be transported between two nanocapsules when they fuse, demonstrating in situ mixing without using complex microfluidic schemes. The ability to synthesize nanocapsules with controlled sizes and to monitor dynamics simultaneously inside multiple nanocapsules provides opportunities to investigate nanoscale processes such as single nanoparticle synthesis in confined volumes and biological processes such as biomineralization and membrane dynamics.

36 MATERIALS SCIENCE↗

Control of electroosmosis in coated quartz capillaries

The effectiveness of various coatings for controlling the electroosmotic fluid flow that hinders electrophoretic processes is studied using analytical particle microelectrophoresis. The mobilities of 2-micron diameter glass and polystyrene latex spheres (exhibiting both negative and zero effective surface charge) were measured in 2-mm diameter quartz capillaries filled with NaCl solutions within the 3.5-7.8 pH range. It is found that capillary inner surface coatings using 5000 molecular weight (or higher) poly(ethylene glycol): significantly reduced electroosmosis within the selected pH range, were stable for long time periods, and appeared to be more effective than dextran, methylcellulose, or silane coatings.

Herren, Blair J.↗

RF characteristics of the hoop column antenna for the land mobile satellite system mission

A communication system using a satellite with a 118 meter diameter quad aperture antenna to provide telephone service to mobile users remotely located from the large metropolitan areas where the telephone companies are presently implementing their cellular system is described. In this system, which is compatible with the cellular system, the mobile user communicates with the satellite at UHF frequencies. The satellite connects him at S-Band, to the existing telephone network via a base station. The results of the RF definition work for the quad aperture antenna are presented. The elements of the study requirements for the LMSS are summarized, followed by a beam topology plan which satisfies the mission requirements with a practical and realiable configuration. The geometry of the UHF antenna and its radiation characteristics are defined. The various feed alternatives, and the S-band aperture are described.

Foldes, P.↗

Elimination of the bias-stress effect in ligand-free quantum dot field-effect transistors

Field-effect transistors (FETs) made from colloidal quantum dot (QD) solids commonly suffer from current–voltage hysteresis caused by the bias-stress effect (BSE), which complicates fundamental studies of charge transport in QD solids and the use of QD FETs in electronics. Here, we show that the BSE can be eliminated in n-channel PbSe QD FETs by first removing the QD ligands with a dose of H 2 S gas and then infilling the QD films with alumina by atomic layer deposition (ALD). The H 2 S-treated, alumina-infilled FETs have stable, hysteresis-free device characteristics (total short-term stability), indefinite air stability (total long-term stability), and a high electron mobility of up to 14 cm 2 V −1 s −1 , making them attractive for QD circuitry and optoelectronic devices. The BSE-free devices are utilized to conclusively establish the dependence of the electron mobility on temperature and QD diameter. We demonstrate that the BSE in these devices is caused by both electron trapping at the QD surface and proton drift within the film. The H 2 S/alumina chemistry produces ligand-free PbSe/PbS/Al 2 O 3 interfaces that lack the traps that cause the electronic part of the BSE, while full alumina infilling stops the proton motion responsible for the ionic part of the BSE. In conclusion, our matrix engineering approach should aid efforts to eliminate the BSE, boost carrier mobilities, and improve charge transport in other types of nanocrystal solids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low cost satellite land mobile service for nationwide applications

A satellite land mobile system using mobile radios in the UHF band, and Ku-band Communications Routing Terminals (earth stations) for a nationwide connection from any mobile location to any fixed or mobile location, and from any fixed location to any mobile location is proposed. The proposed nationwide satellite land mobile service provides: telephone network quality (1 out of 100 blockage) service, complete privacy for all the users, operation similar to the telephone network, alternatives for data services up to 32 Kbps data rates, and a cost effective and practical mobile radio compatible with system sizes ranging from 10,000 to 1,000,000 users. Seven satellite alternatives (ranging from 30 ft diameter dual beam antenna to 210 ft diameter 77 beam antenna) along with mobile radios having a sensitivity figure of merit (G/T) of -15 dB/deg K are considered. Optimized mobile radio user costs are presented as a function of the number of users with the satellite and mobile radio alternatives as system parameters.

Weiss, J. A.↗

Utilization of Mobile VLBI for Geodetic Measurements

Three mobile very long base interferometry (VLBI) systems were fabricated for the NASA Crustal Dynamics Project. These systems include the 9-meter-diameter MV-3 telescope. Since 1980, mobile systems operated in conjunction with several fixed base stations in the western United States as part of a geodetic survey program to determine relative motions and regional strain fields near the tectonic plate boundaries in California and Alaska. A description is given of the three mobile systems and the environment in which they must function. The inherent accuracy of mobile VLBI measurements is assessed, based on a consideration of major sources of error. Some recent results are presented which serve to illustrate various aspects of the error model and are of geodetic interest as they span the broad region surrounding the surface trace of the San Andreas Fault. These results indicate that baseline measurements utilizing the current mobile VLBI systems attained an accuracy of 2 cm or better in the horizontal plane. It is likely that crustal motions will be detected within the next few years, provided they are presently occurring at the geological rates.

Davidson, J. M.↗

Utilization of mobile VLBI for geodetic measurements

Three mobile very long base interferometry (VLBI) systems were fabricated for the NASA Crustal Dynamics Project. These systems include the 9-meter-diameter MV-3 telescope. Since 1980, mobile systems operated in conjunction with several fixed base stations in the western United States as part of a geodetic survey program to determine relative motions and regional strain fields near the tectonic plate boundaries in California and Alaska. A description is given of the three mobile systems and the environment in which they must function. The inherent accuracy of mobile VLBI measurements is assessed, based on a consideration of major sources of error. Some recent results are presented which serve to illustrate various aspects of the error model and are of geodetic interest as they span the broad region surrounding the surface trace of the San Andreas Fault. These results indicate that baseline measurements utilizing the current mobile VLBI systems attained an accuracy of 2 cm or better in the horizontal plane. It is likely that crustal motions will be detected within the next few years, provided they are presently occurring at the geological rates.

Davidson, J. M.↗

CsPbBr3 perovskite detectors with 1.4% energy resolution for high-energy γ-rays

Halide perovskite semiconductors are poised to revitalize the field of ionizing radiation detection as they have done to solar photovoltaics. We show that all-inorganic perovskite CsPbBr 3 devices resolve 137 Cs 662-keV γ-rays with 1.4% energy resolution, as well as other X- and γ-rays with energies ranging from tens of keV to over 1 MeV in ambipolar sensing and unipolar hole-only sensing modes with crystal volumes of 6.65 mm 3 and 297 mm 3 , respectively. Furthermore, we report the scale-up of CsPbBr 3 ingots to up to 1.5 inches in diameter with an excellent hole mobility–lifetime product of 8 × 10 -3 cm 2 V -1 and a long hole lifetime of up to 296 μs. CsPbBr 3 detectors demonstrate a wide temperature region from ~2 °C to ~70 °C for stable operation. Detectors protected with suitable encapsulants show a uniform response for over 18 months. Consequently, we identify perovskite CsPbBr 3 semiconductor as an exceptional candidate for new-generation high-energy γ-ray detection.

47 OTHER INSTRUMENTATION↗

Microbial Diffraction Gratings as Optical Detectors for Heavy Metal Pollutants

As a significant industrial pollutant, cadmium is implicated as the cause of itai-itai disease. For biological detection of cadmium toxicity, an assay device has been developed using the motile response of the protozoa species, Tetrahymena pyriformis. This mobile protozoa measures 50 microns in diameter, swims at 10 body lengths per second, and aggregates into macroscopically visible patterns at high organism concentrations. The assay demonstrates a Cd(+2) sensitivity better than 1 micro-M and a toxicity threshold to 5 micro-M, thus encouraging the study of these microbial cultures as viable pollution detectors. Using two-dimensional diffraction patterns within a Tetrahymena culture, the scattered light intensity varies with different organism densities (population counts). The resulting density profile correlates strongly with the toxic effects at very low dosages for cadmium (less than 5 ppm) and then for poison protection directly (with nickel and copper antagonists competing with cadmium absorption). In particular, copper dosages as low as 0.1-0.5 mM Cu have shown protective antagonism against cadmium, have enhanced density variability for cultures containing 1 mM Cd(+2) and therefore have demonstrated the sensitivity of the optical detection system. In this way, such microbial diffraction patterns give a responsive optical measure of biological culture changes and toxicity determination in aqueous samples of heavy metals and industrial pollutants.

Noever, David↗

Extremely Slow Diffusion of Gold Nanoparticles under Confinement in Mesoporous Silica

Here, we report an X-ray photon correlation spectroscopy (XPCS) study of the mobility of colloidal gold nanoparticles with a diameter of approximately 4 nm in glycerol under confinement within the channels of SBA-15 mesoporous silica with pore diameters of approximately 6 and 12 nm. The XPCS correlation functions result from an effective heterodyne signal due to the mixing of the coherent scattering from the nanoparticles and the mesoporous silica. Over the range of wave vectors and hence length scales probed, the nanoparticle dynamics are well described by one-dimensional diffusion. The nanoparticle diffusivity varies with temperature in a manner expected based on the temperature-dependent viscosity of glycerol; however, the magnitudes of the diffusion coefficients are several orders of magnitude smaller than those of the nanoparticles in bulk glycerol. We consider mechanisms that might contribute to this reduction in diffusivity including enhancement in hydrodynamic drag under confinement, effects of nanoparticle adsorption to the pore walls, and slowing structural dynamics in glycerol due to the combination of the nanometer-scale confinement and the presence of the nanoparticles.

36 MATERIALS SCIENCE↗

Studies on aqueous two phase polymer systems useful for partitioning of biological materials

The two phase systems that result when aqueous solutions of dextran and poly(ethylene glycol) (PEG) are mixed above a critical concentration of a few percent provide a useful medium for the separation of biological cell subpopulations via partition between the top, PEG-rich phase and the liquid-liquid phase boundary. Interfacial tensions of such systems have been measured by the rotating drop technique and found to range between 0.1-100 micro-N/m. The tension was found to depend on the length of the tie line describing the system on a phase diagram, via a power law relationship which differed depending on the concentration of Na phosphate buffer present. The electrokinetic properties of drops of one phase suspended in the other were studied for a variety of systems. It was found that the droplet electrophoretic mobility increased monotonically with phosphate concentration and drop diameter but exhibited the opposite sign from that anticipated from phosphate partition measurements. It was possible to take advantage of these electrokinetic properties and dramatically enhance the speed of phase separation through application of relatively small electric fields.

Brooks, D. E.↗

Satellite Ka-band propagation measurements in Florida

Commercial growth of interactive, high data rate communication systems is expected to focus on the use of the Ka-band (20/30 GHz) radio spectrum. The ability to form narrow spot beams and the attendant small diameter antennas are attractive features to designers of mobile aeronautical and ground based satellite communication systems. However, Ka-band is strongly affected by weather, particularly rain, and hence systems designs may require a significant link margin for reliable operations. Perhaps the most stressing area in North America, weatherwise, is the Florida sub-tropical climatic region. As part of the NASA Advanced Communications Technology Satellite (ACTS) propagation measurements program, beacon and radiometer data have been recorded since December 1993 at the University of South Florida (USF), Tampa, Florida.

Helmken, Henry↗

In situ investigation of the mobility of small gold clusters on cleaved MgO surfaces

The mobility of small clusters of gold (about 10 A in diameter) on electron-beam-cleaved MgO surfaces was studied by in situ transmission electron microscopy under controlled vacuum and temperature conditions. During the first 10 min following a deposition at room temperature, over 10 per cent of the crystallites moved over short distances (about 20 A) discontinuously, with a velocity greater than 150 A/sec. Eighty per cent of the mobility events were characterized by the avoidance of proximity of other crystallites, and this was tentatively explained as the result of repulsive elastic forces between the interacting crystallites.

Metois, J. J.↗

Sizing a Common Habitat for Multiple Environments and Mission Durations

A human mission to Mars and other deep space destinations will require a consistent habitation strategy that applies to disparate environments preferably using multiples of identical hardware. The crew will endure high-g forces during launch, microgravity during transit, and various partial gravities on the destination planet, moon, or asteroid. Habitable volume will likely need to be broken up into smaller modules that do not exceed the capacity of launch vehicles and entry-descent-landing technologies. Though it may be possible to design a different unique, optimized habitat for each environment that the crew may encounter, it is more likely that space agencies and other mission sponsors will only have the resources to develop and produce single multi-use hardware that can be used equally well in all environments, with minimal adaptation by the crew. When sizing habitable volume, mission duration and number of crew become important factors to consider. For example, a pressurized rover cabin may only need to support two crew members for a few days at a time, requiring less volume than a habitat that must support the same number of persons for an entire year. In this study the authors consider constraining factors such as launch vehicle capacity, mission duration, crew size, and Mars lander capacity and study how to divide total pressurized volume, subsystems, equipment, consumables, and supplies into multiple manifests. Preference has been given to solutions that use multiples of identical modules over unique optimized volumes. For example at one extreme, can all the habitat pressure vessels, logistic modules, Mars ascent stage cabins, rover cabins, and airlocks be constructed from multiples of the same small-diameter cylindrical modules? On the other extreme, can logistics, habitation volume, mobility, all be enclosed in a single monolithic volume habitat design? Though there may be advantages and disadvantages to either extreme, the conclusion of this study is that most functions can be distilled into two sizes for hardware: multiples of large diameter modules that generally stay in one place, and multiples of smaller volume cabins that can be moved around or function as cockpits for ascent stages, support vehicles, rovers, airlocks, and logistics delivery.

Howe, A Scott↗