Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

A bi-level data-driven framework for fault-detection and diagnosis of HVAC systems

Long-term operation of heating, ventilation, and air conditioning (HVAC) systems will eventually lead to a range of HVAC system failures, resulting in excessive energy consumption and maintenance costs. Here, to avoid HVAC malfunctioning, fault detection diagnostic (FDD) is utilized as a common practice. Machine learning methods have lately received considerable interest for FDD analysis of HVAC systems due to their high detection accuracy. Meanwhile, HVAC malfunctions are regarded as rare occurrences, hence normal operating data samples are much more accessible than data samples in faulty and malfunctioning conditions. The dominating frequency of normal operation in HVAC datasets has also led to heavily biased classification algorithms within the literature. Moreover, the focus of previous literature has been on increasing the accuracy of the models which leads to a high number of false positives (misleading alarms) in the system. In order to enhance the performance of diagnostic procedures and fill the mentioned gaps, this study proposes a novel data-driven framework. A bi-level machine learning framework is developed for diagnosing faults in air handling units (AHUs) and rooftop units (RTUs) based on principal component analysis (PCA), time series anomaly detection, and random forest (RF). It is shown that PCA can reduce the dataset dimension with one principal component accounting for 95% of data variance. Also, the random forest could classify the faults with 89% precision for single-zone AHU, 85% precision for RTU, and 79% for multi-zone AHU. By proposing this framework, three persistent challenges are addressed: (I) minimizing false positives; (II) accounting for data imbalance; and (III) normal condition monitoring of equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data reduction considerations for the burning velocity of spherical constant volume flames of R32 (CH 2 F 2 ) with air

Here, the present work explores data reduction techniques for the measurement of the laminar burning velocities of R32(CH 2 F 2 )-air mixtures using a constant volume combustion device, in which the pressure-time history is the only measured parameter. To allow clear assessment of the accuracy of the data reduction methods, the pressure-time histories used for analysis are synthetically generated via a detailed numerical simulation employing full kinetics and with and without an optically-thin radiation model. Various data reduction models are employed, including a two-zone model and two multi-zone models, and these are compared with the results from the burning velocity obtained from the output of the numerical simulation. The data reduction schemes are shown to be accurate if the same radiation model is employed in the data reduction as was used in the flame simulation to generate the pressure trace used for post-processing. If the incorrect radiation model is employed, however, the errors can be quite large. The effects of stretch, radiation, and different data post-processing methodologies are explored and the errors quantified. Stretch is shown to be important for the early stages and the selected data range that is used for extrapolation has a significant effect on the extrapolated burning velocity. However, with an appropriate choice of data considered for extrapolation, the prediction of the unstretched burning velocity can be quite accurate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Smarter building start – A distributed solution

A significant focus of research and new technologies for reducing energy use in buildings is on operating the systems more efficiently during the times when the systems are active. However, there is a large potential for energy savings in determining the periods when the systems should or should not be active. This scheduling aspect of operation is often overlooked even though relatively simple solutions can unlock substantial energy savings. In this paper we describe a smart building start (SBS) algorithm that considers multiple zones in a building to determine individual schedules for room controllers as well as the central systems based on solving a simple optimization problem. Application of the SBS algorithm to multiple interconnected systems enables a staggered start-up that minimizes peak loads and also ensures comfort is within a target range with minimal system run time. The SBS algorithm extends the capability of traditional optimal start and is designed to be simple to deploy and robust. Simulation results as well as results from tests in a real building with a VAV system are presented. The presented algorithm is applicable to any type of building with a zonal or multi-zone HVAC system. To function, it needs to be able to change setpoints in rooms and monitor room temperatures, as well as, if desired, turn the central system on or off.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid combustion modeling approach for turbulent jet ignition in natural-gas pre-chamber spark-ignition engines at high EGR

Here, this study presented a hybrid modeling approach for simulating turbulent jet ignition and combustion processes in a natural-gas pre-chamber spark-ignition engine operating under exhaust gas recirculation (EGR) diluted conditions. In-depth analyses of experimental data and simulation results from previous work [Chinnathambi et al., ICEF2021-67836; Kim et al., Fuel 409: 137815, 2026] revealed two key findings: (i) the magnitude of pressure difference between the pre-chamber and main chamber ($∆P_{PC-MC}$) was positively correlated with the combustion duration from the moment of $∆P_{PC-MC}=0$ to the point of 5% mass fraction burned, with larger $∆P_{PC-MC}$ associated with longer duration; and (ii) the turbulent combustion regime in the main chamber transitioned from the broken reaction zone to the corrugated flamelet regime, with the Karlovitz number exceeding 100 immediately after turbulent hot jets were ejected from nozzles, coinciding with observed local extinction events. To accurately simulate the entire combustion process, a hybrid approach was developed under Reynolds-Averaged Navier Stokes framework, combining the G-equation model for pre-chamber combustion with the multi-zone well-stirred reactor approach and a turbulence-chemistry interaction (TCI) submodel for main chamber combustion. The TCI submodel accounted for the attenuation of reaction rates due to turbulent strain and modeled local extinction by suppressing reaction rates under certain flow and flame conditions. When applied to three EGR rate conditions toward the dilution limit, the hybrid modeling approach accurately reproduced experimental data in terms of cylinder pressure, apparent heat release rate, and the observed positive correlation, including the delayed onset of main chamber combustion—a feature not captured by existing combustion models.

computational fluid dynamics simulation↗

Deep Learning Explicit Differentiable Predictive Control Laws for Buildings

We present a differentiable predictive control (DPC) methodology for learning constrained control laws for unknown nonlinear systems. DPC poses an approximate solution to multiparametric programming problems emerging from explicit nonlinear model predictive control (MPC). Contrary to approximate MPC, DPC does not require supervision by an expert controller. Instead, a system dynamics model is learned from a small dataset of recorded observations of the perturbed system's dynamics and the control law is optimized offline by interaction with the learned system model. The DPC method is based on two sequential steps, i) system identification using a constrained neural state-space model, and ii) optimization of an explicit control law parametrized by another neural network in closed-loop simulation with the identified neural state-space model. The combination of a differentiable closed-loop system and penalty methods for constraint handling of system outputs and inputs allows us to optimize the control law's parameters directly by backpropagating economic MPC loss through the learned system model. By incorporating domain knowledge and leveraging established techniques from optimal control, our method leverages deep neural networks as nonlinear function approximators for system identification and control while avoiding concomitant costs of intractably large datasets, and computationally expensive over-parametrized models. The scalability, data efficiency, and constrained optimal control capability of the proposed DPC method are demonstrated in simulation using a multi-zone building emulator.

Drgona, Jan↗

Evaluation of thermostat location for multizone commercial building performance

In multi-zone buildings, it is often found that a single shared thermostat controls more than one conditioned zones. Although these shared zones are supposed to have similar thermal needs (e.g., cooling and heating load), in reality, they are not mainly due to different orientations, sizes of windows, occupancy, space types, etc. This can cause unnecessary energy waste or thermal discomfort for the occupants. How to quantify this impact in multizone buildings remains a research gap. Therefore, this study aims to evaluate the impact of different sensor (i.e., thermostat) locations for multizone commercial buildings through a comprehensive modeling study. Here, two different scenarios for the sensor locations were selected to evaluate the impact in terms of energy and thermal comfort. The scenario (1) is that one to five sensors distributed among the five zones, but the sensor readings from selected zones will be used for no-sensor zones, which is no-mean sensor scenario. The scenario (2) is that one to five sensors distributed among the five zones, but the average temperature from the shared zones will be used for each of the shared zones, which is a mean sensor scenario. The uncertainty analysis was performed for different sensor location scenarios.(a)The major findings from an energy perspective, for scenario (1), the differences of cooling energy go as high as 17% more or 12% less, compared with the baseline. For heating energy consumption, the discrepancies go as high as 51% more or 52% less, compared with baseline. For site energy consumption, the discrepancies go as high as 3.2% more or 3.2% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.2% more or as low as 1.0% less, compared with baseline. For scenario (2), the discrepancies of cooling energy go as high as 3% more, or 0.5% less, compared with the baseline. For heating energy consumption, the discrepancies, are go as high as 10.1% more or as low as 3.0% less, compared with baseline. For site energy consumption, the discrepancies go as high as 1.3% more or 0.3% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.1% more or as low as 1.0% less, compared with baseline.(b) In terms of the indoor thermal comfort, for the no-mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 1,200 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 740 h, compared with the baseline. For the mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 750 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 50 h, compared with the baseline.

42 ENGINEERING↗

EnergyPlus-MCP: A model-context-protocol server for ai-driven building energy modeling

Traditional building energy modeling with the EnergyPlus building performance simulation engine requires domain expertise, programming skills, and intensive manual efforts limiting its effective adoption. This paper introduces EnergyPlus-MCP, the first open-source Model Context Protocol (MCP) server specifically designed for EnergyPlus simulation workflows, establishing a new foundational infrastructure for AI-driven building energy modeling. The MCP server implements a layered architecture with 35 specialized tools spanning model management, editing and analysis, HVAC and other systems configuration inspection, and simulation execution, enabling Large Language Models to interact with EnergyPlus through conversational interfaces. The server addresses critical workflow barriers by automating model validation, streamlining energy efficiency measures modification, and providing intelligent output management with interactive visualization. Through practical demonstrations using a multi-zone building retrofit analysis, we show how the EnergyPlus-MCP server significantly reduces manual efforts while maintaining full simulation rigor. By providing accessible natural language interfaces to sophisticated building energy analysis, this approach enables scalable deployment of simulation expertise across public and private organizations, educational institutions, and research teams, fundamentally transforming traditional building energy modeling practices.

AI↗

Insights into the broadband emission of the TeV blazar Mrk 501 during the first X-ray polarization measurements

Aims.We present the first multiwavelength study of Mrk 501 that contains simultaneous very-high-energy (VHE)γ-ray observations and X-ray polarization measurements from the Imaging X-ray Polarimetry Explorer (IXPE). Methods.We used radio-to-VHE data from a multiwavelength campaign carried out between March 1, 2022, and July 19, 2022 (MJD 59639 to MJD 59779). The observations were performed by MAGIC,Fermi-LAT,NuSTAR,Swift(XRT and UVOT), and several other instruments that cover the optical and radio bands to complement the IXPE pointings. We characterized the dynamics of the broadband emission around the X-ray polarization measurements through its multiband fractional variability and correlations, and compared changes observed in the polarization degree to changes seen in the broadband emission using a multi-zone leptonic scenario. Results.During the IXPE pointings, the VHE state is close to the average behavior, with a 0.2–1 TeV flux of 20%–50% of the emission of the Crab Nebula. Additionally, it shows low variability and a hint of correlation between VHEγ-rays and X-rays. Despite the average VHE activity, an extreme X-ray behavior is measured for the first two IXPE pointings, taken in March 2022 (MJD 59646 to 59648 and MJD 59665 to 59667), with a synchrotron peak frequency > 1 keV. For the third IXPE pointing, in July 2022 (MJD 59769 to 59772), the synchrotron peak shifts toward lower energies and the optical/X-ray polarization degrees drop. All three IXPE epochs show an atypically low Compton dominance in theγ-rays. The X-ray polarization is systematically higher than at lower energies, suggesting an energy stratification of the jet. While during the IXPE epochs the polarization angles in the X-ray, optical, and radio bands align well, we find a clear discrepancy in the optical and radio polarization angles in the middle of the campaign. Such results further support the hypothesis of an energy-stratified jet. We modeled broadband spectra taken simultaneous to the IXPE pointings, assuming a compact zone that dominates in the X-rays and the VHE band, and an extended zone stretching farther downstream in the jet that dominates the emission at lower energies.NuSTARdata allow us to precisely constrain the synchrotron peak and therefore the underlying electron distribution. The change between the different states observed in the three IXPE pointings can be explained by a change in the magnetization and/or the emission region size, which directly connects the shift in the synchrotron peak to lower energies with the drop in the polarization degree.

Astronomy & Astrophysics↗

Controlling Air Conditioners for Frequency Regulation: A Real-World Example

Even though thermostatically controlled loads like air conditioners present a great potential for providing ancillary services to the electric power grid, the practical challenges associated with their real-time coordination have not received the necessary attention. In this work, we present a nondisruptive load control application, specifically, we demonstrate how real residential air conditioners can provide frequency regulation. Aggregate power adjustment is achieved by modifying the ON/OFF modes of the air conditioners. To account for both single and multi-zone houses, we extend the currently available techniques and develop an approach that can be used for controlling aggregations that include both types of houses. A discussion of the practical challenges encountered in our field experiments is provided, along with the hardware and software approaches we developed to circumvent them. Here, we argue that limitations of current thermostat APIs introduce significant challenges and are an impediment to widespread adoption of fast load control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Guideline 36 Savings Calculator v0.1

This software package contains a simple calculator that can be used to estimate savings from implementing a retrofit of HVAC controls to ASHRAE Guideline 36 in a multi-zone office building. Implemented in Excel, the calculator has a user-interface front-end to configure parameters of the case study, such as location, building size, and existing control strategies, and a back-end containing results from a large number of pre-run annual energy simulations. The software package also contains the simulation models and associated pre- and post-processing scripts to generate these results.

Blum, David↗

LBC (Learning Building Control)

LBC encompasses the source code and data to reproduce and extend results for a manuscript that compares demand responsive control schemes for multi-zone buildings. It includes examples of model predictive control (MPC), value function approximation via CVXPYLAYERS, and differentiable predictive control (DPC). The goal of the study is to evaluate state-of-the-art controllers and establish the efficacy (if any) of learning-based approaches that leverage deep neural networks in one way or another.

Zhang, Xiangyu↗

Numerical investigation of a fueled pre-chamber spark-ignition natural gas engine

Pre-chamber spark-ignition (PCSI) is a leading advanced ignition concept for internal combustion engines with the potential to enable diesel-like efficiency in medium-duty/heavy-duty (MD/HD) natural gas (NG) engines. By leveraging distributed ignition sources from multiple turbulent jets, the PCSI technology can deliver extremely short combustion duration in ultra-lean mixtures and significantly improve the engine thermal efficiency. However, in the automotive industry there is a lack of adequate science base and predictive simulation tools required for commercial development of PCSI engines. Here, in this study, Reynolds-Average Navier-Stokes simulations are carried out to describe the combustion process in lean-burn NG engines, focusing on the combustion modeling approach. Two combustion models, multi-zone well-stirred reactor (MZ-WSR) and G-equation, are used to simulate the combustion process in an MD NG engine equipped with a fueled-PCSI system for four operating conditions close to the lean operating limit. A skeletal chemical mechanism and a laminar flame speed tabulation are used to compute the combustion accurately. Simulation results are compared with experimental data regarding measured cylinder pressure, heat release rate, and combustion duration. By dividing the PCSI combustion process into four distinct phases, the difference between the two models’ results for each phase is analyzed in detail. The MZ-WSR model overestimates the combustion duration for early flame kernel growth in the pre-chamber due to the lack of a specific formulation to take turbulence-chemistry interaction into account. Despite the prolonged combustion duration and low pressure built-up inside the pre-chamber, the model matches the combustion rate in the main-chamber. In contrast, the G-equation model delivers good agreements for the pre-chamber combustion and turbulent jet-driven combustion processes. However, the model starts to underestimate the combustion rate in the main-chamber, especially under ultra-lean mixture conditions. Finally, improvements are needed for both models to simulate the later combustion stage that occurred in the near-wall regions.

33 ADVANCED PROPULSION SYSTEMS↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NuSTAR broad-band X-ray observation campaign of energetic pulsar wind nebulae in synergy with VERITAS, HAWC and Fermi gamma-ray telescopes

We report recent progress on the on-going NuSTAR observation campaign of 8 TeV-detected middle-aged pulsar wind nebulae (PWNe). This campaign constitutes a major part of our NuSTAR study of some of the most energetic TeV sources in our Galaxy detected by VERITAS and HAWC. NuSTAR is the first focusing X-ray telescope operating above 10 keV in space with sub-arcminute angular resolution. Broad-band X-ray imaging and spectroscopy data, obtained by NuSTAR, allow us to probe sub-PeV electron populations through detecting synchrotron X-ray radiation. Our targets include PeVatron candidates detected by HAWC, the Boomerang nebula, PWNe crushed by supernova remnant shocks (or relic PWNe) and G0.9‚0.1 in the Galactic Center. Combined with Fermi-LAT data and available TeV data, we aim to provide a complete, multi-wavelength view of a diverse class of middle-aged (~10–100 kyrs old) PWNe. Our NuSTAR analysis detected hard X-ray emission from the Eel and Boomerang PWNe and characterized their broad-band X-ray spectra most accurately. We plan to apply both time-evolution and multi-zone PWNe models to multi-wavelength spectral energy distribution (SED) data over the radio, X-ray, GeV and TeV bands. In this proceeding, we will review our observation campaign and discuss the preliminary results for some PWNe.

79 ASTRONOMY AND ASTROPHYSICS↗

Incipient Sensor Fault Impacts on Building Performance Through HVAC Controls: A Pilot Study

Sensors are crucial input components for HVAC controls. Studies show faults are common for buidings and HVAC systems. Sensors with faults will compromise the control perfrormance regardless how advanced of the control algorithms. Majority studies assume the sensor fault to be constant the whole year. In reality, the sensor faults might evolve or develop with time, which is essentially the incipient (i.e. evolving) fault. The incipient sensor faults impacts remain a research gap. This study aims to investigate the incipient sensor fault impacts to control sequences of multi-zone VAV boxes and AHU system following the ASHRAE Guideline 36-2018: High-Performance Sequences of Operation.

Li, Yanfei↗

First-principles-integrated Study of Blazar Synchrotron Radiation and Polarization Signatures from Magnetic Turbulence

Blazar emission is dominated by nonthermal radiation processes that are highly variable across the entire electromagnetic spectrum. Turbulence, which can be a major source of nonthermal particle acceleration, can widely exist in the blazar emission region. The Turbulent Extreme Multi-Zone (TEMZ) model has been used to describe turbulent radiation signatures. Recent particle-in-cell (PIC) simulations have also revealed the stochastic nature of the turbulent emission region and particle acceleration therein. However, radiation signatures have not been systematically studied via first-principles-integrated simulations. In this paper, we perform combined PIC and polarized radiative transfer simulations to study synchrotron emission from magnetic turbulence in the blazar emission region. We find that the multiwavelength flux and polarization are generally characterized by stochastic patterns. Specifically, the variability timescale and average polarization degree (PD) are governed by the correlation length of the turbulence. Interestingly, magnetic turbulence can result in polarization angle swings with arbitrary amplitudes and duration, in either direction, that are not associated with changes in flux or PD. Surprisingly, these swings, which are stochastic in nature, can appear either bumpy or smooth, although large-amplitude swings (>180°) are very rare, as expected. Our radiation and polarization signatures from first-principles-integrated simulations are consistent with the TEMZ model, except that in the latter, there is a weak correlation, with zero lag, between flux and degree of polarization.

79 ASTRONOMY AND ASTROPHYSICS↗

Bridging Scales in Black Hole Accretion and Feedback: Magnetized Bondi Accretion in 3D GRMHD

Fueling and feedback couple supermassive black holes (SMBHs) to their host galaxies across many orders of magnitude in spatial and temporal scales, making this problem notoriously challenging to simulate. We use a multi-zone computational method based on the general relativistic magnetohydrodynamic (GRMHD) code KHARMA that allows us to span 7 orders of magnitude in spatial scale, to simulate accretion onto a non-spinning SMBH from an external medium with a Bondi radius of R B ≈ 2 × 10 5 GM•/c 2 , where M• is the SMBH mass. For the classic idealized Bondi problem, spherical gas accretion without magnetic fields, our simulation results agree very well with the general relativistic analytic solution. Meanwhile, when the accreting gas is magnetized, the SMBH magnetosphere becomes saturated with a strong magnetic field. The density profile varies as ~r -1 rather than r -3/2 and the accretion rate $\dot{M}$ is consequently suppressed by over 2 orders of magnitude below the Bondi rate $\dot{M}$ B . Here, we find continuous energy feedback from the accretion flow to the external medium at a level of $\thicksim$ 10 -2 $\dot{M}$c 2 $\thicksim$ 5 X 10 -5 $\dot{M}$ B c 2 . Energy transport across these widely disparate scales occurs via turbulent convection triggered by magnetic field reconnection near the SMBH. Thus, strong magnetic fields that accumulate on horizon scales transform the flow dynamics far from the SMBH and naturally explain observed extremely low accretion rates compared to the Bondi rate, as well as at least part of the energy feedback.

79 ASTRONOMY AND ASTROPHYSICS↗