Search NASA⌕ Search

SEARCH · Search NASA

Results for “multichannel analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Preliminary study on detection sediment contamination in soil affected by the Indian Ocean giant tsunami 2004 in Aceh, Indonesia using laser-induced breakdown spectroscopy (LIBS)

This work is intended to asses the capability of LIBS for the detection of the tsunami sediment contamination in soil. LIBS apparatus used in this work consist of a laser system and an optical multichannel analyzer (OMA) system. The soil sample was collected from in Banda Aceh City, Aceh, Indonesia, the most affected region by the giant Indian Ocean tsunami 2004. The laser beam was focused onto surface of the soil pellet using a focusing lens to produce luminous plasma. The experiment was conducted under air as surrounding gas at 1 atmosphere. The emission spectral lines from the plasma were detected by the OMA system. It was found that metal including heavy metals can surely be detected, thus implying the potent of LIBS technique as a fast screening tools of tsunami sediment contamination.

54 ENVIRONMENTAL SCIENCES↗

SPARSE FARADAY ROTATION MEASURE SYNTHESIS

Faraday rotation measure synthesis is a method for analyzing multichannel polarized radio emissions, and it has emerged as an important tool in the study of Galactic and extragalactic magnetic fields. The method requires the recovery of the Faraday dispersion function from measurements restricted to limited wavelength ranges, which is an ill-conditioned deconvolution problem. Here, we discuss a recovery method that assumes a sparse approximation of the Faraday dispersion function in an overcomplete dictionary of functions. We discuss the general case when both thin and thick components are included in the model, and we present the implementation of a greedy deconvolution algorithm. We illustrate the method with several numerical simulations that emphasize the effect of the covered range and sampling resolution in the Faraday depth space, and the effect of noise on the observed data.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-534: Level of Residual Radioactivity of Activated Parts of a Decommissioned Cyclotron

Purpose: CTI cyclotron RDS-111 was used at the Hong Kong Sanatorium and Hospital (HKSH) to produce radiopharmaceuticals and radioactive tracers for diagnostic scans between 1999 and 2007. During the operation, some machine components became radioactive by activation. For the safety of staff, decommissioning took place in 2009, two years after the cyclotron had stopped operation. This study investigates the residual radioactivity and radionuclides found in different cyclotron components in 2014 in compliance with the local regulations in Hong Kong for transfer of radioactive waste. Methods: A representative sample of each part was counted using a high-purity germanium detector (manufacturer: ORTECT) for at least four hours. GammaVision, a multichannel analyzer software, was used to identify the radionuclides found in the cyclotron components, as well as the associated activities. A standard library and a Mariscotti peak search algorithm were used to identify the present radionuclides. Only radionuclides with half-life greater than 180 days were considered. Results: Among the components, the Havar target foil has the highest specific activity ((4.6±0.6)×10{sup 2} Bq/g), with Co-60 being the most prominent ((3.8±0.5)×10{sup 2} Bq/g). The total activity of the target foil, however, is still low due to its small mass of 0.04 g. Radioisotopes Mn-54 (46±6 Bq/g), Na-22 (6.8±0.8 Bq/g), Co-57 (7.3±0.9 Bq/g), and Fe-59 (6.0±0.9 Bq/g) have also been detected in the target foil. The target window holder and the vacuum window register a specific activity of 88.3±0.6 Bq/g and 48.6±0.1 Bq/g, respectively. Other components, such as the collimator, the target tube, the valve body and the beamline, are also found with trace amounts of radionuclides. Conclusion: Even seven years after the cyclotron had stopped operation, some components still exhibited residual radioactivity from activation exceeding the IAEA clearance levels. Special consideration for radiological protection may need to be taken in the disposal of the cyclotron parts.

07 ISOTOPE AND RADIATION SOURCES↗

Testing of Kaonetics Devices at BNL

The goal of these measurements was to evaluate whether there is evidence of emission of X-rays, gamma-rays, and neutrons by devices developed by Kaonetics Technologies, Inc. during their operation. The measurements were carried out with two Kaonetics’s modules, called EMR Gen 1 ("Device 1") and EMR Gen 2 ("Device 2"). Two types of detectors were set up in a remote building to avoid potential interference from other labs. For X- and gamma-rays we used a large-volume, high-sensitivity NaI(Tl) Bicron scintillation detector and a multichannel analyzer (MCA). For neutrons, we employed a ~ ½ liter 3He-filled proportional counter. The measurements were taken under normal background-dominated conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GADRAS isotope ID user s manual for analysis of gamma-ray measurements and API for Linux and Android .

Isotope identification algorithms that are contained in the Gamma Detector Response and Analysis Software (GADRAS) can be used for real-time stationary measurement and search applications on platforms operating under Linux or Android operating sys-tems. Since the background radiation can vary considerably due to variations in natu-rally-occurring radioactive materials (NORM), spectral algorithms can be substantial-ly more sensitive to threat materials than search algorithms based strictly on count rate. Specific isotopes or interest can be designated for the search algorithm, which permits suppression of alarms for non-threatening sources, such as such as medical radionuclides. The same isotope identification algorithms that are used for search ap-plications can also be used to process static measurements. The isotope identification algorithms follow the same protocols as those used by the Windows version of GADRAS, so files that are created under the Windows interface can be copied direct-ly to processors on fielded sensors. The analysis algorithms contain provisions for gain adjustment and energy lineariza-tion, which enables direct processing of spectra as they are recorded by multichannel analyzers. Gain compensation is performed by utilizing photopeaks in background spectra. Incorporation of this energy calibration tasks into the analysis algorithm also eliminates one of the more difficult challenges associated with development of radia-tion detection equipment.

97 MATHEMATICS AND COMPUTING↗

Measurement of Plutonium Isotopic Composition - MGA

In this module, we will use the Canberra InSpector-2000 Multichannel Analyzer with a high-purity germanium detector (HPGe) and the MGA isotopic anlysis software to assay a variety of plutonium samples. The module provides an understanding of the MGA method, its attributes and limitations. You will assess the system performance by measuring a range of materials similar to those you may assay in your work. During the final verification exercise, the results from MGA will be combined with the 240Pueff results from neutron coincidence or multiplicity counters so that measurements of the plutonium mass can be compared with the operator-declared (certified) values.

07 ISOTOPE AND RADIATION SOURCES↗

GADRAS Isotope ID User's Manual for Analysis of Gamma-Ray Measurements and API for Linux and Android

Isotope identification algorithms that are contained in the Gamma Detector Response and Analysis Software (GADRAS) can be used for real-time stationary measurement and search applications on platforms operating under Linux or Android operating systems. Since the background radiation can vary considerably due to variations in naturally-occurring radioactive materials (NORM), spectral algorithms can be substantially more sensitive to threat materials than search algorithms based strictly on count rate. Specific isotopes or interest can be designated for the search algorithm, which permits suppression of alarms for non-threatening sources, such as such as medical radionuclides. The same isotope identification algorithms that are used for search applications can also be used to process static measurements. The isotope identification algorithms follow the same protocols as those used by the Windows version of GADRAS, so files that are created under the Windows interface can be copied directly to processors on fielded sensors. The analysis algorithms contain provisions for gain adjustment and energy linearization, which enables direct processing of spectra as they are recorded by multichannel analyzers. Gain compensation is performed by utilizing photo-peaks in background spectra. Incorporation of this energy calibration tasks into the analysis algorithm also eliminates one of the more difficult challenges associated with development of radiation detection equipment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Benchmark Gamma Spectroscopy Measurements of Uranium Hexafluoride in Aluminmum Pipe with a Sodium Iodide Detector

The expected increased demand in fuel for nuclear power plants, combined with the fact that a significant portion of the current supply from the blend down of weapons-source material will soon be coming to an end, has led to the need for new sources of enriched uranium for nuclear fuel. As a result, a number of countries have announced plans, or are currently building, gaseous centrifuge enrichment plants (GCEPs) to supply this material. GCEPs have the potential to produce uranium at enrichments above the level necessary for nuclear fuel purposes-enrichments that make the uranium potentially usable for nuclear weapons. As a result, there is a critical need to monitor these facilities to ensure that nuclear material is not inappropriately enriched or diverted for unintended use. Significant advances have been made in instrument capability since the current International Atomic Energy Agency (IAEA) monitoring methods were developed. In numerous cases, advances have been made in other fields that have the potential, with modest development, to be applied in safeguards applications at enrichment facilities. A particular example of one of these advances is the flow and enrichment monitor (FEMO). (See Gunning, J. E. et al., 'FEMO: A Flow and Enrichment Monitor for Verifying Compliance with International Safeguards Requirements at a Gas Centrifuge Enrichment Facility,' Proceedings of the 8th International Conference on Facility Operations - Safeguards Interface. Portland, Oregon, March 30-April 4th, 2008.) The FEMO is a conceptual instrument capable of continuously measuring, unattended, the enrichment and mass flow of {sup 235}U in pipes at a GCEP, and consequently increase the probability that the potential production of HEU and/or diversion of fissile material will be detected. The FEMO requires no piping penetrations and can be installed on pipes containing the flow of uranium hexafluoride (UF{sub 6}) at a GCEP. This FEMO consists of separate parts, a flow monitor (FM) and an enrichment monitor (EM). Development of the FM is primarily the responsibility of Oak Ridge National Laboratory, and development of the EM is primarily the responsibility of Los Alamos National Laboratory. The FM will measure {sup 235}U mass flow rate by combining information from measuring the UF{sub 6} volumetric flow rate and the {sup 235}U density. The UF{sub 6} flow rate will be measured using characteristics of the process pumps used in product and tail UF{sub 6} header process lines of many GCEPs, and the {sup 235}U density will be measured using commercially available sodium iodide (NaI) gamma ray scintillation detectors. This report describes the calibration of the portion of the FM that measures the {sup 235}U density. Research has been performed to define a methodology and collect data necessary to perform this calibration without the need for plant declarations. The {sup 235}U density detector is a commercially available system (GammaRad made by Amptek, www.amptek.com) that contains the NaI crystal, photomultiplier tube, signal conditioning electronics, and a multichannel analyzer (MCA). Measurements were made with the detector system installed near four {sup 235}U sources. Two of the sources were made of solid uranium, and the other two were in the form of UF{sub 6} gas in aluminum piping. One of the UF{sub 6} gas sources was located at ORNL and the other at LANL. The ORNL source consisted of two pipe sections (schedule 40 aluminum pipe of 4-inch and 8-inch outside diameter) with 5.36% {sup 235}U enrichment, and the LANL source was a 4-inch schedule 40 aluminum pipe with 3.3% {sup 235}U enrichment. The configurations of the detector on these test sources, as well as on long straight pipe configurations expected to exist at GCEPs, were modeled using the computer code MCNP. The results of the MCNP calculations were used to define geometric correction factors between the test source and the GCEP application. Using these geometric correction factors, the experimental 186 keV counts in the test geometry were extrapolated to the expected GCEP geometry, and calibration curves were developed. A unique method to analyze the measurement was also developed that separated the detector spectrum into the five detectable decay gamma rays emitted by {sup 235}U in the 120 to 200 keV energy range. This analysis facilitated the assignment of a consistent value for the detector counts originating from {sup 235}U decays at 186 keV. This value is also more accurate because it includes the counts from gamma energies other than 186 keV, which results in increased counting statistics for the same measurement time. The 186 keV counts expected as a function of pressure and enrichment are presented in the body of this report. The main result of this research is a calibration factor for 4-inch and 8-inch schedule 40 aluminum pipes. For 4-inch pipes, the {sup 235}U density is 0.62 {sup 235}U g/m{sup 3} per each measured 186 keV count.

March-Leuba, Jose A↗

Characterization of a modified printed optical particle spectrometer for high-frequency and high-precision laboratory and field measurements

Abstract. The printed optical particle spectrometer (POPS) is a lightweight, low-cost instrument for measurements of aerosol number concentrations and size distributions. This work reports on modifications of the Handix Scientific commercial version of the POPS to facilitate its use in multi-instrument aerosol sampling systems. The flow system is modified by replacing the internal pump with a needle valve and a vacuum pump. The instrument is integrated into closed-flow systems by routing the sheath flow from filtered inlet air. A high-precision multichannel analyzer (MCA) card is added to sample the analog pulse signal. The MCA card is polled at 10 Hz frequency using an external data acquisition system and improves upon the count-rate limitation associated with the POPS internal data acquisition system. The times required to change the concentration between 90 % and 10 % and vice versa for a step change in concentration were measured to be 0.17 and 0.41 s at a flow rate of 5 cm3 s−1. This yields a sampling frequency of ∼ 1–2 Hz, below which the amplitude of measured fluctuations is captured with > 70 % efficiency. The modified POPS was integrated into the dual tandem differential mobility analyzer system to explore the coalescence of dimer particles. Results show that the pulse-height response increases upon dimer coalescence. The magnitude of the increase is broadly consistent with the change in light-scattering amplitude predicted by the T-matrix method. It is anticipated that this modified version of the POPS will extend the utilization of the technique for a range of field and laboratory applications.

54 ENVIRONMENTAL SCIENCES↗

High-speed digital plotter

Modified typewriter mechanism with standard logic components provides digital plot of output of multichannel analyzer. Unit plots irregular curves at approximately 14 channels per second, and smooth curves at over 25 channels per second, and is not subject to analog error or drift.

Gray, J., Jr.↗

Thermospheric temperature measurement technique.

A method for measurement of temperature in the earth's lower thermosphere from a high-velocity probes is described. An undisturbed atmospheric sample is admitted to the instrument by means of a free molecular flow inlet system of skimmers which avoids surface collisions of the molecules prior to detection. Measurement of the time-of-flight distribution of an initially well-localized group of nitrogen metastable molecular states produced in an open, crossed electron-molecular beam source, yields information on the atmospheric temperature. It is shown that for high vehicle velocities, the time-of-flight distribution of the metastable flux is a sensitive indicator of atmospheric temperature. The temperature measurement precision should be greater than 94% at the 99% confidence level over the range of altitudes from 120-170 km. These precision and altitude range estimates are based on the statistical consideration of the counting rates achieved with a multichannel analyzer using realistic values for system parameters.

Hueser, J. E.↗

Device for recording the 20 Hz - 200 KHz sound frequency spectrum using teletransmission

The device described consists of two distinct parts: (1) The sound pickup system consisting of the wide-frequency band condenser microphone which contains in the same assembly the frequency-modulated oscillator and the output stage. Being transistorized and small, this system can be easily moved, so that sounds can be picked up even in places that are difficult to reach with larger devices. (2) The receiving and recording part is separate and can be at a great distance from the sound pickup system. This part contains a 72 MHz input stage, a frequency changer that gives an intermediate frequency of 30 MHz and a multichannel analyzer coupled to an oscilloscope and a recorder.

Baciu, I.↗

Nondestructive activation analysis of sample of lunar surface material returned by Luna 16 automatic station

The composition of a sample of lunar surface material returned by the Luna 16 automatic station from the Sea of Fertility was studied, using nondestructive activation analysis. The structure of the returned surface material is inhomogeneous; the surficial material is thin, quite homogeneous, and the granularity increases with depth. Based on grain size, the sample was separated into five zones. The activation analysis was conducted on a sample taken from the friable surficial layer, zone A. The content of Al, Mn, Na, Cr, Co, Fe, and Sc was determined by nondestructive activation analysis of the sample. In determining Cr, Co, Fe, and Sc, the sample was irradiated for 24 hours and cooled for 10 days. Gamma spectra of the samples were recorded with a semiconductor Ge(Li)-detector and a multichannel analyzer, and measurement data were processed with an electronic computer.

Chayko, M.↗

Measurements of H-beta, He D3, and Ca/+/ 8542-A line emission in quiescent prominences

Measurements of H-beta, He D3, and Ca(+) 8542-A line emission in 18 quiescent prominences are presented which were performed with a 25-cm coronagraph/coude spectrograph system and an optical multichannel analyzer utilizing a Si-vidicon detector assembly mounted at the single-pass spectrograph port. The data obtained show that the line profiles deviate in the wings from those calculated on the basis of an isothermal atmosphere and a Gaussian absorption coefficient. Both a non-Gaussian microturbulence component and a temperature gradient from prominence-core to coronal values can successfully account for this phenomenon. The line widths from a given line of sight of prominence material are reduced on the basis of a common core emitting region with a temperature of 7500 to 11,600 K and a microturbulent velocity of 4.5 to 7.1 km/s for the isothermal model (these values are 5% to 10% less for the two-temperature model). It is noted that long-period low-amplitude oscillations in the D3 line width and intensity were observed when a specific line of sight in a quiescent prominence was followed. These oscillations are found to remain coherent for as many as 3 or 4 cycles and to be associated with prominence structural activation.

Landman, D. A.↗

OAST Space Theme Workshop. Volume 2: Theme summary. 3: Search for extraterrestrial intelligence (no. 9). A: Theme statement. B. 26 April 1976 presentation. C. Summary. D. Newer initiatives (form 4). E. Initiative actions (form 5)

Preliminary (1977-1983), intermediate (1982-1988), and long term (1989+) phases of the search for extraterrestrial intelligence (SETI) program are examined as well as the benefits to be derived in radioastronomy and the problems to be surmounted in radio frequency interference. The priorities, intrinsic value, criteria, and strategy for the search are discussed for both terrestrial and lunar-based CYCLOPS and for a space SETI system located at lunar liberation point L4. New initiatives related to antenna independent technology, multichannel analyzers, and radio frequency interference shielding are listed. Projected SETI program costs are included.

Source record↗

Daylight spectra of individual lightning flashes in the 370-690 nm region

An optical multichannel analyzer slit spectrometer coupled to a minicomputer was used to record lightning spectra. This is the first successful application of a slit spectrometer to the study of individual lightning flashes and it was accomplished in the daytime. Over 300 spectra were obtained in 1978 and 1979 and are correlated with other experiments in the Thunderstorm Research International Program (TRIP). The spectra duplicate previously published nighttime data but reveal for the first time the relative intensity of H-alpha (656.3 nm) and H-beta (486.1 nm) emissions above their daytime absorption features. These are the characteristic Fraunhofer C and F lines in the solar spectrum. This result suggests that the observation of lightning from space may be accomplished by monitoring the hydrogen emissions from lightning which occur on earth, or on other planets with hydrogen in their atmospheres, such as Jupiter and Venus where lightning recently has been reported.

Orville, R. E.↗

Single-pulse broad-band rotational CARS thermometry of cold N2 gas

Coherent anti Stokes Raman scattering (CARS) from the pure rotational Raman lines of N2 was employed to measure the instantaneous (10 nsec) rotational temperature of the gas at room temperature and below. An entire rotational CARS spectrum was generated by a single laser pulse using a broad bandwidth dye laser and was recorded on an optical multichannel analyzer. A best fit temperature obtained for individual experimental spectra by comparison with calculated spectra. Good agreement between CARS temperatures and thermocouple temperatures was observed.

Chang, R. K.↗

Quiescent prominence spectrophotometry - Sodium D1,2, helium D3, and calcium /plus/ lambda 8498

The reported observations were carried out by means of a 25 cm coronagraph/coude spectrograph with a Si vidicon Optical Multichannel Analyzer (OMA) detector. The results of the investigation are presented in a number of tables, and the main conclusions concerning the studies are discussed. The relative behavior of prominence Na D line emission shows that the employed observing techniques yield reliable measures of prominence line strengths, not degraded to any substantial extent, in particular, by possible slit-filling effects. This conclusion is limited principally by the assumption that systematic vertical velocity fields in the prominences are not greater than 1.5 km/s. The Na D line profiles are well fitted by a one-component (i.e., homogeneous) line-forming region, thus reinforcing previous conclusions regarding the source of the enhanced wing emission.

Landman, D. A.↗