Non-Contact Eddy Current Method for Assessing Proton Conductivity in Nafion Membranes

Accurate measurement of proton conductivity in Proton Exchange Membranes (PEMs) is vital for fuel cell performance and durability. This study explores eddy current testing as a non-destructive, non-contact and high-rate quality control (QC) method for measuring Nafion membrane proton conductivity, with potential for high-volume manufacturing applications.

33 ADVANCED PROPULSION SYSTEMS↗

Toward predictive permeabilities: Experimental measurements and multiscale simulation of methanol transport in Nafion

A polymer membrane's permeability to solutes determines its suitability for various applications: a permeability value is essential for predicting performance in diverse contexts. Using aqueous methanol permeation through Nafion as an example, we describe a methodology for determining membrane permeability that accounts for boundary layer effects and the possibility of swelling. For the materials and apparatus used herein, analysis of a permeance measurement and computational fluid dynamics simulations show that the mass transfer boundary layer is on the order of ones to tens of microns. Additionally, the data are used to develop and validate a multiscale model describing solute permeation through a hydrated membrane as a series of physical mechanistic steps: reversible adsorption from solution at the membrane interface, diffusion driven by a concentration gradient within the membrane, and reversible desorption into solution at the opposite membrane interface. The validated model is used to predict methanol transport across a solar-driven CO 2 reduction device and to assess the impact of polymer changes on the measured value. The approach of combining experimental data, computational fluid dynamics, and the mechanistic multiscale model is expected to provide more accurate analysis of membrane permeation data in cases with polymer swelling or unusual device geometries, among others.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of Ce 3+ , Co 2+ , Mn 2+ and Fe 2+ diffusion coefficients in Nafion® membrane

Concentration gradient diffusion coefficients for Ce 3+ , Co 2+ , Mn 2+ and Fe 2+ cations are determined in Nafion®211 membranes over a wide range of environmental conditions. Measurements are made using finite-width cation-rich bands introduced to NR211 via a hot-pressing procedure. A robust method of accurate diffusion coefficient determination of the finite-width deposits is developed using a Fick's second law of diffusion solution for one-dimensional systems. The transition metal dications are found to have nearly identical NR211 diffusion coefficients under water saturated conditions over the 22–80 °C range. The powerful chemical mitigant, Ce 3+ , is about one-half as diffusive as the dications under identical conditions. Derived diffusion coefficients for Ce 3+ and Co 2+ are found to be independent of initial cation concentration over the range of 12.5–70 mol% exchange level. The diffusion behavior of Ce 3+ in 80 °C liquid water and saturated water vapor is identical. The diffusion coefficients of Ce 3+ are shown to have a strong dependence on membrane hydration level varying by a factor of more than 30 over the range of 95 to 40% RH. Finally, the implications of these new diffusion findings are applied to a discussion of potential guidelines for the development of highly durable fuel cell systems, which employ mobile metal cations as lifetime-extending redox stabilizers.

08 HYDROGEN↗

Electrodialysis through nafion membranes coated with polyelectrolyte multilayers yields >99% pure monovalent ions at high recoveries

Separation of monovalent and multivalent ions is important in processes ranging from water softening to recycling of Li. Previous studies show that cation-exchange membranes coated with multilayer polyelectrolyte films exhibit monovalent/divalent ion selectivities as high as 1000 in electrodialysis (ED) under ideal conditions with low ion recoveries. This work shows that even at 60-80% monovalent-ion recoveries, ED through Nafion membranes coated with protonated poly(allylamine)/poly(4-styrenesulfonate) multilayers can separate equimolar K + and Mg 2+ or Li + and Mg 2+ to give 99.5% pure monovalent ion. Moreover, the use of a low-volume receiving phase allows ED to concentrate the monovalent ion. Typical current efficiencies are around 70% for these separations. Selectivities appear to increase when the membrane-coating procedure uses a higher polyelectrolyte concentration in the deposition solution. Because the limiting current declines with ED time due to depletion of the monovalent ion in the source phase, use of a gradually decreasing applied current enhances current efficiency compared to ED at a constant high current. Further, the membranes also show Li + /Mg 2+ selectivities around 100 when Mg 2+ is in a 20-fold excess in the source phase at an ionic strength of 0.6 M, but selectivity decreases at even higher ionic strengths.

15 GEOTHERMAL ENERGY↗

Delineating Confinement Regimes for Nafion Thin Films via Simultaneous QCM-D and Spectroscopic Ellipsometry

Proton-conducting ionomers used in electrodes of electrochemical devices form nanometer-scale films covering metallic catalyst surfaces, wherein they experience confinement and interfacial effects absent in the bulk polymer. This confinement alters the physical properties of the ionomer film, which is postulated to increase the density and is attributed to the transport limitations observed in fuel-cell electrodes. Despite studies showing reduced swelling, no systematic measurement has validated this phenomenon by demonstrating both densification and stiffening as the film gets thinner. Here, this study aims to fill this gap by reporting the humidity-driven changes in swelling, mass uptake, and density of Nafion ionomer films cast at varying thicknesses (10–320 nm) onto a gold-plated sensor. The films were simultaneously probed during humidification using spectroscopic ellipsometry (SE) and a quartz crystal microbalance with dissipation (QCM-D), which allowed for determination of the density and shear stiffness. The effects of confinement were prominently observed below ∼30 nm, with films showing increased density along with decreased swelling and mass uptake during hydration. In addition, the confined films show a negative excess volume upon initial water sorption, implying a larger proportion of absorbed water might bound to ionic groups in accord with notion of localized densification.

Espinet, Kevin B. [University of California, Berke↗

Size and Charge Effects on Crossover of Flow Battery Reactants Evaluated by Quinone Permeabilities Through Nafion

Organic reactants are promising candidates for long-lifetime redox flow batteries, and synthetic chemistry unlocks a wide design space for new molecules. Minimizing crossover of these molecules through ion exchange membranes is one important design consideration, but the ways in which the crossover rate depends on the structure of the crossing species remain unclear. Here, we contribute a systematic evaluation of size- and charge-based effects on dilute-solution small molecule permeability through the Nafion NR212 cation exchange membrane. We found that increasing the magnitude of charge number z with the same sign as membrane fixed charges, achieved here by successive sulfonation of quinone redox cores, results in more than an order of magnitude permeability reduction per sulfonate. Size-based effects, understood by comparing the Stokes radii of the quinones studied, also reduces permeability with increasing effective molecule size, but doubling the effective size of the redox reactants resulted in a permeability decrease of less than a factor of three.

25 ENERGY STORAGE↗

Electrochemical performance and transport properties of a Nafion membrane in a hydrogen-bromine cell environment

The overall energy conversion efficiency of a hydrogen-bromine energy storage system is highly dependent upon the characteristics and performance of the ion-exchange membrane utilized as a half-cell separator. The electrochemical performance and transport properties of a duPont Nafion membrane in an aqueous HBr-Br2 environment were investigated. Membrane conductivity data are presented as a function of HBr concentration and temperature for the determination of ohmic voltage losses across the membrane in an operational cell. Diffusion-controlled bromine permeation rates and permeabilities are presented as functions of solution composition and temperature. Relationships between the degree of membrane hydration and the membrane transport characteristics are discussed. The solution chemistry of an operational hydrogen-bromine cell undergoing charge from 45% HBr to 5% HBr is discussed, and, based upon the experimentally observed bromine permeation behavior, predicted cell coulombic losses due to bromine diffusion through the membrane are presented as a function of the cell state-of-charge.

Baldwin, Richard S.↗

The platinum microelectrode/Nafion interface - An electrochemical impedance spectroscopic analysis of oxygen reduction kinetics and Nafion characteristics

The objectives of this study were to use electrochemical impedance spectroscopy (EIS) to study the oxygen-reduction reaction under lower humidification conditions than previously studied. The EIS technique permits the discrimination of electrode kinetics of oxygen reduction, mass transport of O2 in the membrane, and the electrical characteristics of the membrane. Electrode-kinetic parameters for the oxygen-reduction reaction, corrosion current densities for Pt, and double-layer capacitances were calculated. The production of water due to electrochemical reduction of oxygen greatly influenced the EIS response and the electrode kinetics at the Pt/Nafion interface. From the finite-length Warburg behavior, a measure of the diffusion coefficient of oxygen in Nafion and diffusion-layer thickness was obtained. An analysis of the EIS data in the high-frequency domain yielded membrane and interfacial characteristics such as ionic conductivity of the membrane, membrane grain-boundary capacitance and resistance, and uncompensated resistance.

Parthasarathy, Arvind↗

Nafion(TM) Coats For Electrodes In Liquid-Feed Fuel Cells

Coating or impregnation with commercially available material enables oxidation of organic liquid fuels. Nafion(TM) investigated for use in application because of known combination of desirable characteristics: It is perfluorinated, hydrophilic, proton-conducting ion-exchange polymer exhibiting relatively high thermal and electrochemical stability and not detrimental to kinetics of electrochemical processes. Available in solubilized form and used to apply stable coats to surfaces of electrodes.

Narayanan, Sekharipuram R.↗

Optimization of a Nafion Membrane-Based System for Removal of Chloride and Fluoride from Lunar Regolith-Derived Water

A long-term human presence in space will require self-sustaining systems capable of producing oxygen and potable water from extraterrestrial sources. Oxygen can be extracted from lunar regolith, and water contaminated with hydrochloric and hydrofluoric acids is produced as an intermediate in this process. We investigated the ability of Nafion proton exchange membranes to remove hydrochloric and hydrofluoric acids from water. The effect of membrane thickness, product stream flow rate, and acid solution temperature and concentration on water flux, acid rejection, and water and acid activity were studied. The conditions that maximized water transport and acid rejection while minimizing resource usage were determined by calculating a figure of merit. Water permeation is highest at high solution temperature and product stream flow rate across thin membranes, while chloride and fluoride permeation are lowest at low acid solution temperature and concentration across thin membranes. The figure of merit varies depending on the starting acid concentration; at low concentration, the figure of merit is highest across a thin membrane, while at high concentration, the figure of merit is highest at low solution temperature. In all cases, the figure of merit increases with increasing product stream flow rate.

Anthony, Stephen M.↗