INSTRUMENTATION FOR IN-CORE REAL-TIME MECHANICAL TESTING OF STRUCTURAL MATERIALS (INCREASE) PROJECT

Idaho National Laboratory (INL), in collaboration with the Electric Power Research Institute (EPRI), Nuclear Regulatory Commission, French Atomic and Alternative Energies Commission (CEA), Joint Research Centre, Nuclear Research and Consultancy Group, and Research Center Rez, is the operating agent of the In-Core Real-Time Mechanical Testing of Structural Materials (INCREASE) joint experimental program (JEEP) project that operates within the Nuclear Energy Agency (NEA)’s Framework for Irradiation Experiments (FIDES-II) program. The first objective of the INCREASE project is to design a shared capsule that can house a variety of in-core mechanical testing instrumentation for enabling smart irradiation experiments. The second objective is to collect in core stress relaxation data pertaining to high priority stainless steel (SS) materials under light water reactor conditions with target temperature of 340°C +/-20°C and a minimum neutron damage of 2 displacement per atom (dpa). The INCREASE project will be demonstrated in the Massachusetts Institute of Technology Nuclear Research Reactor (MITR).

36 MATERIALS SCIENCE↗

Evaluation report on the Thermo Scientific TruDose (neutron,gamma) EPD3

This report summarizes an evaluation study on the Thermo Scientific TruDose n/γ EPD3 by LANL’s RP-SVS group. Two EPD3s were received for assessment (SNs 7500100 and 7500108) along with an EPD3 desktop reader. The evaluation included intercomparisons with Thermo’s N2 EPD which is in wide circulation at LANL but is no longer commercially available. A favourable assessment of the TruDose EPD3 would help support it as a viable option to replace the N2 EPD. The data and observations included in this report could also serve as the basis of a Technical Basis Document for the use of the EPD3 at LANL.

61 RADIATION PROTECTION AND DOSIMETRY↗

USF/Russian dosimetry on STS-57

The major purpose of this experiment was to conduct an international comparison of passive dosimetry methods in space. Two APD's were flown in the charged particle directional spectrometer (CPDS)/tissue equivalent proportional counter (TEPC) locker on the space shuttle during the STS-57 mission. Due to placement, the shielding and radiation environment of the APD's were nearly the same and the dosimeters distributed in the two boxes can be considered equally exposed. The dosimeter types included plastic nuclear track detectors (PNTD's), thermoluminescent detectors (TLD), nuclear emulsions, and thermal/resonance neutron detectors (TRND's). The USF dosimeters included PNTD's, TLD's, and TRND's, while the Russian dosimeters included PNTD's, TLD's, and nuclear emulsions.

Source record↗

MEASUREMENT OF THE NEUTRON FLUENCE-RATES IN THE ADVANCED TEST REACTOR

The axial neutron fluence-rate distribution at the Advanced Test Reactor (ATR) is determined using a combination of pure nickel and cobalt-aluminium alloy dosimeter wires. Most irradiation programs at ATR need to know the fast neutron fluence-rate surrounding their experiment to correlate post-irradiation examination results with neutron dose. The activated dosimeter wires, which extend beyond the full fuelled region of the reactor core, are highly radioactive following the full cycle in ATR and must therefore be measured in the ATR canal. The system that is employed for these measurements is mechanical scanning mechanism is used to scan the activated wires across the face of a columnated shield and a NaI detector. This detector is not sufficiently calibrated to provide absolute activity measurements, therefore, the count-rate is recorded and normalized to the highest activity for that wire. Then, an approximately 3-mm long portion of the wire is removed from the highest activity region in the wire. The wires are then transferred, and an absolute activity measurement is made using a calibrated ionization chamber. These measurements are combined with corrections for decay, neutron energy spectrum, burnup, dosimeter composition, reactor power fluctuations, and reactor outages to determine the average axial neutron fluence-rate at various locations within ATR during the cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Fission-like Neutron Spectrum Shaping Assembly based on D-T Generator

For nearly five decades, 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. While there appear to be no other radionuclide neutron sources that would match the 252 Cf performance characteristics, all of them, including 252 Cf, present similar concerns in terms of hazards, safety, and security. As a possible solution to this issue, the Pacific Northwest National Laboratory (PNNL) developed a low-risk, cost-efficient alternative to produce fission-like spectra based on commercially available deuterium-tritium (D-T) neutron generators. The alternative of producing a fission-like neutron spectrum without any fissionable materials or beryllium would enable the nuclear facilities across the entire complex to eliminate their reliance on high intensity 252 Cf sources for nuclear safety and radiation protection applications, substantially reducing risks and associated costs. This report describes efforts of designing the spectrum shaping assembly, its construction and characterization of the neutron field produced. Performance of this newly developed D-T generator based neutron field is demonstrated via calibration of a criticality detector, neutron survey instruments, and personal dosimeters verified against current standardized fields produced by 252 Cf spontaneous fission sources.

42 ENGINEERING↗

IER-484 CED3b Report: AFRRI ER1 Dosimetry Characterization

This report presents the preliminary work for IER 484, the characterization of the leakage radia tion field from the TRIGA reactor at the Armed Forces Radiobiology Research Institute (AFRRI). The purpose of the dose characterization is to establish the reference dose needed to execute a NAD inter-comparison exercise. During the week of August 20th, a team from Lawrence Livermore National Laboratory (LLNL), Sandia National Laboratory (SNL), and Institut de Radioprotection et de Sûreté Nucléaire (IRSN) performed various measurements in AFRRI’s TRIGA ER1 (Exposure Room 1) with Passive Neutron Spectrometer (PNS) spheres and nuclear accident dosimeters (NADs) mounted on Bottle Manikin Absorption (BOMAB) phantoms (to simulate doses received by people) and additional NADs mounted on aluminum plates (to simulate doses in free air). Without Atomic Weapons Establishment (AWE), LLNL became responsible for measuring the neutron spectrum using PNS spheres. SNL is responsible for providing photon dose data. LLNL, SNL, and IRSN each deployed their own NADs, which will be compared to the reference dose measured. Final characterization of the dose field based on analyzed data will be presented in the CED4a report.

42 ENGINEERING↗

Universal Nuclear Accident Dosimeter

The Lawrence Livermore National Laboratory (LLNL) Universal Nuclear Accident Dosimetry (UNAD) project is a four-year initiative aimed at advancing nuclear accident dosimetry methods. This article presents an overview of the research, key findings, and the progress made throughout the project. The primary goals included a background into the history of nuclear accident dosimetry, consolidating current dosimetry techniques within the NNSA/DOE complex, fostering collaboration among subject matter experts, and exploring novel technologies for potential implementation. The technical focus centered on investigating new and novel technologies, instrumentation methods, and analysis methods to develop recommendations for a potential nuclear accident dosimeter (NAD) to be universally deployed through the DOE complex. A multilaboratory and multinational Usergroup was established, conducting periodic meetings to facilitate knowledge exchange. The UNAD team has participated in two international nuclear accident dosimetry intercomparison exercises and one characterization exercise, where the existing LLNL NAD and a prototype alanine electron paramagnetic dosimeter NAD were deployed. Ongoing improvements are being made to the prototype NAD based on results from the exercises, laboratory studies, and collaboration with other laboratories. A machine learning algorithm to optimize the geometry and conversion factors of the current LLNL NAD is being implemented, and the resulting design will be tested in the next exercise. In conclusion, key lessons learned and future directions for the project are discussed.

Electron paramagnetic resonance spectroscopy↗

A Review of the Lawrence Livermore Nuclear Accident Dosimeter 1980s-present

A Nuclear Accident Dosimetry program is a federal requirement for all facilities that have the potential to have a criticality accident. Personnel Nuclear Accident Dosimeter (PNAD) theory and analytical procedures are driven by various scientific needs and interacting regulations. A brief history of the status of USA Department of Energy (DOE) nuclear accident dosimetry regulations, recommendations, and performance testing criteria are given. Then, the history of the Lawrence Livermore National Laboratory (LLNL) PNAD is explored, including changes in the physical dosimeter and adjustments of the analysis method through the last four decades. Finally, the performance of LLNL’s PNAD at criticality accident intercomparison training exercises since 2009 is explored. In general, reported neutron doses have been within or close to DOE-STD-1098 performance criteria while reported gamma doses have been outside of DOE-STD-1098 performance criteria. Reported total absorbed doses have varied in meeting ANSI/HPS N13.3 and ANSI/HPS N13.3 (R2019) performance criteria. Dosimetry staff retirement and turnover have left historical knowledge gaps, yet provided opportunities within the NAD program at LLNL. This review paper serves as an overview of the history and status of the NAD program. Brief technical, procedural and programmatic recommendations to improve LLNL’s NAD program are given. Technical recommendations include investigating orientation factors through modeling or empirical experimentation, investigating gamma dosimetry methods for high-dose scenarios, and exploring other dosimetric methods for simpler, quicker NAD analysis. Procedural recommendations include better documentation of conversion factor (activity-to-fluence and fluence-to-dose) derivations and spectrum uses, and updated analysis spreadsheets or simple Graphic User Interfaces for dose calculations. In conclusion, programmatic recommendations include formalized training for NAD analysts, and having multiple SMEs trained on the NAD program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Conceptual Design of Neutron Sensor Qualification Device

The Advanced Sensors and Instrumentation Program at Idaho National Laboratory has been formulating strategies to qualify sensors for use in nuclear environments, particularly in irradiation experiments and advanced reactors. When qualifying neutron sensors for use in high-temperature environments, the wide range of neutron flux levels and representative energy spectra presents significant challenges. This paper discusses the development of the Neutron Sensor Qualification Device (NQD), which is designed to test neutron sensors in high temperature controlled environments with known neutron spectra, addressing the spatial and spectral complexities of neutron fluxes in reactor cores. The proposed NQD will be situated in the exposure room at the Armed Forces Radiobiology Research Institute, thus affording a unique capability to expose sensors to high neutron and gamma fluxes. To achieve thermal control, the device will utilize a radiation-hardened tube furnace, accommodating multiple sensors and neutron activation dosimetry wires. Titanium, iron, and cobalt dosimeter wires are chosen from the American Society for Testing and Materials and International Reactor Dosimetry and Fusion File libraries as references for providing energy-dependent fluence measurements. The design ensures precise sensor positioning to minimize mutual shielding and flux perturbation, which are evaluated via Monte Carlo N particle Transport Code (MCNP) simulations. These simulations have informed the development of guidelines on sensor placement within the NQD. The NQD is essential to the qualification of neutron sensors for advanced reactor technologies. It enables controlled testing of a statistically significant number of sensors, thereby supporting assessments of sensor performance across various neutron flux levels and temperatures. This paper highlights the detailed planning for the NQD prototype, along with its inaugural irradiation (scheduled for fiscal year [FY] 2025). The results from this initial testing will be fundamental in evaluating the device’s performance and establishing measurement uncertainty for in-pile neutron sensor measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron heating assessment in Minerve reactor by using alanine/ESR dosimetry

In the framework of the ICERR (International Center based on Research Reactors) project, the effect of neutron/gamma irradiation on material and dosimeters has been studied. In this work, we explore the alanine dose-response in the core of the MINERVE research reactor at the CEA Cadarache and we investigate the neutron heating effects in order to evaluate alanine neutron sensitivity. The measured dose of the alanine detector in the mixed gamma-neutron field was estimated by electron spin resonance spectrometry (ESR) with reference to an absorbed dose in water from a 60 Co gamma-ray beam. The experimental sources of uncertainties were reduced by using the optimum conditions of charged-particle equilibrium (CPE), obtained by introducing alanine dosimeters into the aluminum pillbox. Cavity correction factors and dose components were evaluated by the Monte Carlo code MCNP. The calculation showed an underestimated neutron dose with a (C/E) value of about 0.993 +/- 10.83%(k = 1). Results indicate that the fast neutron dose, mainly due to elastic neutron scattering on hydrogen nuclei, represents about 70% of the total dose, while the gamma dose was found to be around 45% of the neutron dose. Additionally, the neutron relative efficiency (REn) to 60 Co gamma-radiation was estimated to be 0.544 +/- 8%(k = 1).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Verification and Validation Tests of Gamma Library of MC2-3 for Coupled Neutron and Gamma Heating Calculation

For the accurate assessment of the heat generation rate in fast reactors, the gamma library of MC2 -3 and the MC2 -3 + GAMSOR procedure employing the coupled neutron and gamma heating calculation has been thoroughly verified against Monte Carlo results and validated using the ZPPR-15D gamma dose measurement data. NJOY outputs are post-processed in a consistent way with the NJOY procedure to avoid any missing data or double counting of data. Prompt heating for 379 out of 391 isotopes in the gamma library was verified against MCNP6.2 to within 1% relative error in total heating for most isotopes. For both a simple one-dimensional slab problem representing a sodium cooled fast reactor and the Experimental Breeder Reactor II (EBR-II) benchmark problem, the root-mean-square values of assembly power error were less than 0.5% for fuel assemblies, ~1% in blankets and ~1 to ~3% in reflectors compared to MCNP6.2 results. The most plausible cause for the 3% error in a reflector assembly is believed to be the error in the multigroup neutron cross sections for the reflector assembly. For validation, gamma doses measured with thermoluminiscent dosimeters (TLDs) in the ZPPR-15D experiment were calculated using GAMSOR. Due to the uncertainty in the TLD measurement with regards to the energy deposition of photons and neutrons, the validation data leads to a 12.7% uncertainty on the experimental measurement. With this uncertainty bound, the calculated doses all fell within one standard deviation of the measured value. Combined with the accurate calculation of reaction rate distributions and neutron spectrum measurements, these results indicate good agreement for the neutron and gamma heating calculations that were performed.

coupled neutron and gamma heating↗

AFRRI TRIGA Reactor Neutron and Gamma Dose Characterization Preliminary Results

Integral Experiment Request (IER) 484 is part of a series of dose characterization and nuclear accident dosimeter (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). The Armed Forces Radiobilogy Research Institute (AFRRI) 1.1 MW Training, Research, Isotopes, General Atomics (TRIGA) Mark-F reactor is the third facility to undergo a dose study to establish reference dose values. A preliminary measurement was performed earlier this year, where a variety of foils were irradiated and activation gamma rays were measured using a high-purity germanium (HPGe) detector. The data was taken and analyzed to calculate the neutron spectrum in the irradiation facility. This paper will present preliminary results of the neutron dose measured. The characterization of the AFRRI dose field is planned in August.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of South-East Flux Trap Dosimetry Measurements for the Advanced Test Reactor Critical Facility in support of Advanced Sensors and Instrumentation Development

Reactor dosimetry measurements are commonly used to validate simulation and modeling in nuclear reactor tests. Numerous standard dosimeter materials exist which are commonly utilized with sensitivities to different energy ranges of neutrons. At the Advanced Test Reactor (ATR), cobalt alloy and pure nickel wires are installed every cycle to monitor thermal- and fast-neutron fluence rates. However, there is growing interest in exploring less commonly used materials which are either more sensitive to different parts of the neutron energy spectrum or which can incorporate multiple activation paths in a single material. Epithermal and fast-neutron energies beyond the typical 1-MeV threshold are of particular interest. Two ATR-C Flux Runs took place during 2024; each flux run included supplemental dosimetry packages in the South-East Flux Trap (SEFT) Filler. The focus of the dosimetry package for flux run 23-4 was to test two novel dosimetry methods that can provide simultaneous thermal and threshold (fast) sensitivity in a single dosimeter wire. A selection of 3% Au in Cu alloyed wires were available that provided sensitivity to fast and thermal neutrons through 5 different reactions. Likewise, Fe offers multiple interaction pathways with sensitivity to both thermal and fast neutrons. The main question to be answered by these irradiations was if sufficient radioactivation would take place in the ATR-C SEFT during a nominal 20-minute irradiation at typical power levels (near 600Wth) to observe the threshold reactions that have smaller activation cross-sections than the thermal reactions without being saturated by interfering interactions and Compton continuum during the High-Purity Germanium (HPGe) measurements. The results from comparing the measurement results to anticipated activity levels provide confidence in our ability to activate both traditional and novel dosimetry materials in ATR-C, however not all the measured values matched with the predicted activities. This leaves further room for investigation both on the experimental and computational approaches for future irradiation experiments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

IER-484 CED4a Report: AFRRI ER1 Dosimetry Characterization

This report presents an analytical function as the reference neutron and photon dose (normalized to an ion chamber integral) for future nuclear accident dosimeter (NAD) exercise at the Armed Forces Radiobiology Research Institute (AFRRI). Various dosimeters and equipment were positioned within exposure room 1 (ER1) and irradiated using a 1.1 MW Training, Research, Isotope, General Atomics (TRIGA) Mark-F nuclear reactor. An ion chamber located in ER1 was used as a normalization factor in Equation 2. This allows for a quick calculation of neutron and photon dose based on the ion chamber data. Currently, AFRRI is in preparation to host a NAD exercise this summer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nuclear emulsion measurements of the astronauts' radiation exposure on the Apollo-Soyuz mission

On the Apollo-Soyuz mission each astronaut carried one passive dosimeter containing nuclear photographic emulsions, plastic foils, TLD chips, and neutron-activation foils for recording radiation exposure. This report is limited to the presentation of data retrieved from nuclear emulsions. Protons, most of them trapped particles encountered in numerous passes through the South Atlantic Anomaly, contributed by far the largest share to the mission dose. Their linear energy transfer (LET) spectrum was established from track and grain counts in a G.5 emulsion which is used for medium and high energies, and from ender counts in a K.2 emulsion which is used for low energies. The total mission fluence of protons was found to be equivalent to a unidirectional beam of 448,500 square centimeters. The broad spectrum was broken down into small LET intervals, which allowed for the computation of absorbed doses and dose equivalents. The totals are 51 millirad and 74 millirem. Counts of disintegration stars in K.2 emulsion are incomplete at present. While a total of 467 stars were identified, counting their prong numbers is still in progress. It was concluded that the Apollo-Soyuz astronauts' radiation exposure as such did not contain anything out of the ordinary that would seem to require special attention.

Schaefer, H. J.↗

Modeling and Design of Micro Flux Monitors for Neutron Fluence Measurements

Measuring neutron flux is critical to understanding the characteristics of nuclear reactors and can provide information on the energy spectrum, total neutron fluence, and operational history of a facility. Such measurements are typically performed by irradiating high-purity materials in an operating reactor for a known length of time. By measuring and identifying activation products in the irradiated materials and referencing the energy-dependent cross section of each isotope, the neutron energy spectrum and total fluence can be determined. Historical techniques use a variety of small, individually pressed foils or wires for dosimeter devices, which can result in excessively high levels of radioactivity and complications in handling after irradiation. The present work describes a new neutron dosimetry concept, named the micro flux monitor, that uses semiconductor device fabrication processes to deposit thin films of flux monitoring materials in precise geometries onto a SiC wafer. This approach allows multiple dosimetry materials to be located on a single device, simplifying irradiation and subsequent analysis. The geometry, and therefore mass, of each material can be custom-tailored for a specific application—considering the expected neutron flux, duration of irradiation, and device retrieval time of a facility. Additionally, hundreds of identical dosimetry monitors can be produced simultaneously, reducing fabrication costs. Finally, the extremely thin metal dimensions of these devices could improve the fidelity of neutron fluence measurements by reducing neutron self-shielding and gamma self-attenuation effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor [Poster]

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed. The wirescanner system in the ATR canal is utilized after every reactor cycle by the ATR Radiation Measurements Laboratory (RML) to assess the activation of cobalt and nickel dosimeter wires during the cycle. These wires become activated through exposure to thermal and fast neutrons respectively during the irradiation cycle and are highly radioactive upon shutdown. It is for this reason that the wirescanner is used in the ATR canal rather than transporting the dosimeters to another facility. A scoping study was performed to develop a base-line design to ensure that existing capabilities could be replaced with a new system. The new hardware will enable automated measuring of several flux monitor holders without necessitating the removal of the flux wires. In this way, flux wire measurements will be performed with minimal dose to the technicians and will not be limited by canal operations as is presently the case. The new control and acquisition software will be based on commercially available and supported systems that have a wide user-base to provide long-term stability. An electronically cooled HPGe detector will be used to provide high-resolution gamma-ray measurements, an improvement from the low-resolution sodium-iodide detector that is presently deployed. The electronic cooler eliminates the need for liquid nitrogen to cool the detector head. A new collimator has been designed to house the new detector and allow for sufficient counting rates.